Charlton Home CHRH1504 Installation & Assembly

Ceiling Fan Installation Manual
Limited Lifetime Warranty
Our fan motors are warranted to the original purchaser to be free of electrical and/or mechanical defects for so long as the original purchaser owns the fan. Pull chain switches, reverse switches, capacitors and metal finishes are warranted to be free from defects in materials or workmanship for a period of 1 year from the date of purchase. Warping of wooden or plastic blades is not covered by this warranty nor is corrosion and/or deterioration of any finishes for fans installed within ten miles of any sea coast. Extended warranties for ENERGY STAR
Our ceiling fans with built-in LED light sources, when properly installed and under normal conditions of use, are warranted to be free from defects in material and workmanship which cause the light sources to fail to operate in accordance with the specifications for (i) five (5) years from the date of purchase on the LED Light modules and electrical components for fans used in single family residences, and (ii) three (3) years from the date of purchase on the LED Light modules and electrical components for fans used in multi-family or commercial applications. LED bulbs supplied by us carry no warranty other than manufacturer’s warranty. Non-LED bulbs carry no warranty.
®
qualified products may apply.
Safety Rules.....................................................................................................................................................................................
Unpacking Your Fan .......................................................................................................................................................................
Installing Your Fan ..........................................................................................................................................................................
Operating Your Fan .........................................................................................................................................................................
Care of Your Fan ...........................................................................................................................................................................
Troubleshooting ............................................................................................................................................................................
Specifications ................................................................................................................................................................................
1.
2.
3.
9.
10.
11.
12.
Table of Contents
1. To reduce the risk of electric shock, insure electricity has been turned off at the circuit breaker or fuse box before beginning.
2. All wiring must be in accordance with the National Electrical Code and local electrical codes. Electrical installation should be performed by a qualified licensed electrician.
3. WARNING: To reduce the risk of electrical shock and fire, do not use this fan with any solid-state fan speed control device.
4. WARNING: To reduce the risk of fire, electric shock, or personal injury, mount to outlet box marked "Acceptable for Fan Support of 15.9 kg (35 lbs.) Or Less" and use mounting screws provided with the outlet box. Most outlet boxes commonly used for the support of light fixtures are not acceptable for fan support and may need to be replaced. Due to the complexity of the installation of this fan, a qualified licensed electrician is strongly recommended.
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR PERSONAL
INJURY, MOUNT FAN TO OUTLET BOX MARKED ACCEPTABLE FOR
FAN SUPPORT.
9. Do not use water or detergents when cleaning the fan or fan blades. A dry dust cloth or lightly dampened cloth will be suitable for most cleaning.
10. After making electrical connections, spliced conductors should be turned upward and pushed carefully up into the outlet box. The wires should be spread apart with the grounded conductor and the equipment-grounding conductor on one side of the outlet box.
11. Electrical diagrams are for reference only. Light kits that are not packed with the fan must be UL Listed and marked suitable for use with the model fan you are installing. Switches must be UL General Use Switches. Refer to the Instructions packaged with the light kits.
WARNING:
12.
Locations".
TO REDUCE THE RISK OF PERSONAL INJURY, DO NOT BEND THE
ASSEMBLY OR AFTER INSTALLATION. DO NOT INSERT OBJECTS IN
Use only with light kit marked "Suitable for Use in Wet
WARNING
BLADE ARMS (ALSO REFERRED TO AS BRACKETS) DURING
THE PATH OF THE BLADES.
5. The outlet box and support structure must be securely mounted and capable of reliably supporting a minimum of 35 lbs (15.9 kg) or less. Use only UL-listed outlet boxes marked FOR FAN SUPPORT.
6. The fan must be mounted with a minimum of 7 ft (2.1m) clearance from the trailing edge of the blades to the floor.
7. Avoid placing objects in the path of the blades.
8. To avoid personal injury or damage to the fan and other items, be cautious
when working around or cleaning the fan.
1. Safety Rules
THIS PRODUCT CONTAINS CHEMICALS KNOWN TO THE STATE OF
CALIFORNIA TO CAUSE CANCER, BIRTH DEFECTS AND /OR OTHER
REPRODUCTIVE HARM. THOROUGHLY WASH HANDS AFTER
INSTALLING, HANDLING, CLEANING, OR OTHERWISE TOUCHING
READ AND SAVE ALL INSTRUCTIONS!
WARNING
THIS PRODUCT.
NOTE
2
6
9
3
1
4
5
Unpack your fan and check the contents. You should have the following items:
1. Fan blades (5)
2. Canopy assembly
3. Down rubber cover
4. Ball/downrod assembly
5. Coupling cover
6. Set of blades bracket (5)
7. Fan motor assembly
8. Mounting plate
9. Switch housing
10. Balancing kit
7
8
10
a
c
10
10. Loose parts bag containing:
a. Blade attachment hardware
(16 screws, 16 rubber washers )
b. Mounting hardware
Wire nuts (3)
c. Electrical hardware
Pull chain
b
Unpacking Your Fan 2.
Tools Required
Phillips screw driver, straight slot screw driver, adjustable wrench, step ladder, and wire cutters.
Angled ceiling maximum
18.5 angle
Provide strong support
Mounting Options
If there isn't an existing UL listed mounting box, then read the following instructions. Disconnect the power by removing fuses or turning off circuit breakers.
Secure the outlet box directly to the building structure. Useappropriate fasteners and building materials. The outlet box and its support must be
Figure 1
able to fully support the moving weight of the fan (at least 35 lbs). Do not use plastic outlet boxes.
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC
SHOCK, OR OTHER PERSONAL INJURY,
MOUNT FAN ONLY TO AN OUTLET BOX
MARKED ACCEPTABLE FOR FAN SUPPORT
AND USE THE MOUNTING SCREWS
PROVIDED WITH THE OUTLET BOX. OUTLET
BOXES COMMONLY USED FOR THE
SUPPORT OF LIGHTING FIXTURES MAY NOT
BE ACCEPTABLE FOR FAN SUPPORT AND
MAY NEED TO BE REPLACED. CONSULT A
QUALIFIED ELECTRICIAN IF IN DOUBT.
Figure 2
3. Installing Your Fan
Outlet box
Outlet box
Recessed outlet box
Figure 3
Ceiling hanger bracket
Note: You may need a longer downrod to maintain proper blade clearance when installing on a steep, sloped ceiling.
Figure 4
Outlet box
To hang your fan where there is an existing fixture but no ceiling joist, you may need an installation hanger bar as shown in Figure 4 (available at your Retailer).
Hanging the Fan
REMEMBER to turn off the power. Follow
the steps below to hang your fan properly:
Step 1. Remove the decorative canopy bottom cover from the canopy by turning the cover counter clockwise.(Fig. 5)
Step 2. Remove the mounting bracket from the canopy by removing the 1 of 2 screws from the bottom of the mounting bracket and loosening the other one a half turn from the screw head. Next, turn the canopy counter clockwise to removing the mounting bracket from the canopy. (Fig. 5)
Step 3. Pass the 120-volt supply wires through the center hole in the ceiling hanger bracket as shown in Fig. 6.
Step 4. Secure the hanger bracket to the ceiling outlet box with the screws and washers provided with your outlet box.
Step 5. Remove the hanger pin, lock pin and set screws from the top of the motor assembly.
Step 6. Route wires exiting from the top of the fan motor through the collar cover, canopy cover, canopy and then through the ball / downrod. (Fig. 7)
Step 7. Align the holes at the bottom of the downrod with the holes in the collar on top of the motor housing (Fig. 7). Carefully insert the hanger pin through the holes in the collar and downrod. Be careful not to jam the pin against the wiring inside the downrod. Insert the locking pin through the hole near the end of the hanger pin until it snaps into its locked position, as noted in the circle inset of Fig. 7. Place downrod rubber cover onto the hanger ball.
WARNING
FAILURE TO PROPERLY INSTALL
LOCKING PIN AS NOTED IN STEP 7
COULD RESULT IN FAN LOOSENING AND
POSSIBLY FALLING.
Step 8. Tighten two set screws on top of the fan motor firmly. (Figure 7)
Step 9. Place the downrod ball into the hanger bracket socket.
Ceiling hanger bracket
Ceiling canopy
Canopy
Figure 5
cover
CUL Listed electrical box
Ceiling hanger bracket
Figure 6
Ball/downrod assembly
Figure 7
Hook
Motor wires
Downrod rubber cover
Ceiling canopy
Locking pin
Tighten screws firmly
120V Wires
Mounting screws (supplied with electrical box)
Pin in locked position
Canopy cover
Collar cover
Hanger pin
Motor collar
Washers
4.
Make the Electric Connections
REMEMBER to disconnect the power.
If you feel that you do not have enough electrical wiring knowledge or experience, have your fan installed by a licensed electrician.
Follow the steps below to connect the fan to your household wiring. Use the wire connecting nuts supplied with your fan. Secure the connectors with electrical tape. Make sure there are no loose strands or connections.
Step 1. Connect the ground conductor of the 120V supply (this may be a bare wire or a wire with green colored insulation) to the green ground lead(s) of the fan. (Figure 8)
Step 2. Connect the fan motor white wire to the supply white (neutral) wire using a wire nut. (Figure 8)
Step 3. Connect the fan motor black wire to the supply black (hot) wire using a wire nut. (Figure 8)
Step 4. Connect the blue wire for light kit to the black household supply wire.
Step 5. Turn wire nut connections upward, spreading them apart so the green (ground) will be on one side of the outlet box and the white, black and blue wire will be on the other side, and push carefully up into the outlet box.
CHECK TO SEE THAT ALL CONNECTIONS
ARE TIGHT, INCLUDING GROUND, AND THAT
NO BARE WIRE IS VISIBLE AT THE WIRE NUTS. EXCEPT FOR THE GROUND WIRE.
ELECTRICAL DIAGRAMS ARE FOR REFERENCE
ONLY. OPTIONAL USE OF ANY LIGHT KIT
SHALL BE UL LISTED AND MARKED SUITABLE
TO REDUCE THE RISK OF FIRE OR ELECTRIC
SHOCK. DO NOT USE THIS FAN WITH ANY
SOLID-STATE SPEED CONTROL DEVICE.
WARNING
WARNING
FOR USE WITH THIS FAN.
WARNING
SUPPLY CIRCUIT
Ground Conductor
WHITEWHITE
BLACK
Outlet Box
Green Ground
GREEN
WHITE
Lead Ground to
Downrod
BLUE
BLACK
BLUE
BLACK WHITE
Figure 8
Diagram indicates optional light kit wiring.
5.
Finishing the Installation
Step 1. Tuck connections neatly into ceiling outlet
box.
Step 2. Slide the canopy up to mounting bracket and place the key hole on the canopy over the screw on the mounting bracket, turn canopy until it locks in place at the narrow section of the key holes. (Fig. 9)
Step 3. Align the circular hole on canopy with the remaining hole on the mounting bracket, secure by tightening the two set screws. Note: Adjust the canopy screws as necessary until the canopy and canopy cover are snug.
Outlet box
Figure 9
Hanger bracket
Canopy cover
Screws
Canopy
Step 3. Fasten the blade assembly to the motor using the motor screws provided. (Figure 11)
Screws
Rubber washer
Blade arm
Blade
Figure 10
MAKE SURE THE NOTCH ON THE HANGING
WARNING
BRACKET PROPERLY SITS IN THE GROOVE IN THE HANGER BALL BEFORE ATTACHING THE
CANOPY TO THE BRACKET BY TURNING THE
HOUSING UNTIL IT DROPS INTO PLACE.
Attaching the Fan Blades
CAUTION: Remove 5 rubber packing mounts
and discard before installation.
Step 1. Attach the blades to the blade arms using three screws and rubber washers as shown in Figure 10. Start a screw into the arm, do not tighten. Repeat for the 2 remaining screws and washers.
Step 2. Tighten each screw securely starting with the center screw. Make sure the blade is straight.
Figure 11
Motor
Blade assembly
Screws
6.
Blade Balancing
1. Check that all blade and blade arm screws are
secure.
2. Most fan wobbling problems are caused
when blade levels are unequal. Check this level by selecting a point on the ceiling above the tip of one of the blades. Measure this distance as shown in Figure 12. Rotate the fan until the next blade is positioned for measurement. Repeat for each blade. The distance deviation should be equal within 1/8".
3. Use the enclosed Blade Balancing Kit if the
blade wobble is still noticeable.
4. If the blade wobble is still noticeable,
interchanging two adjacent (side by side) blades can redistribute the weight and possibly result in smoother operation.
TO REDUCE THE RISK OF PERSONAL
INJURY, DO NOT BEND THE BLADE
HOLDERS WHILE INSTALLING,
BALANCING THE BLADES, OR CLEANING
THE FAN. DO NOT INSERT FOREIGN OBJECTS BETWEEN ROTATING FAN
Figure 12
WARNING
BLADES.
Touching ceiling
Installing the Mounting Plate
Step 1.
Remove 1 of the 3 screws from the mounting ring and loosen the other 2 screws. (Do not remove)
Step 2.
Place the key holes on the mounting plate over the 2 screws previously loosened from the mounting ring, turn mounting plate until it locks in place at the narrow section of the key holes. Secure by tightening the 2 screws previously loosened and the one previously removed. (Fig. 13)
Mounting ring
Mounting plate
7.
Figure 13
Screws
Installing the Switch Housing
Step 1.
Remove the 1 of 3 screws from the mounting plate and keep it for future use. Loosen the other 2 screws. (Do not remove)
Step 2.
together.
Step 3.
housing over the 2 screws previously loosened from the mounting plate, turn switch housing until it locks in place at the narrow section of the key holes. Secure by tightening the 2 screws previously loosened and the one previously removed. (Figure 14)
Snap the wire connection plugs
Place the key holes on the switch
Switch housing
Figure 14
Connection plugs
Mounting plate
Screws
8.
Turn on the power and check the operation of the fan. The pull chain controls the fan speed as follows: 1 pull - High 2 pulls - Medium 3 pulls - Low 4 pulls - Off.
Speed settings for warm or cool weather depend on factors such as the room size, ceiling height, number of fans, and so on.
The slide switch controls directions: forward (switch left) or reverse (switch right).
WAIT FOR THE FAN TO STOP BEFORE
NOTE
REVERSING THE DIRECTION
OF THE BLADE ROTATION.
Warm weather - (Forward) A downward air flow creates a cooling effect as shown in Figure 15. This allows you to set your air conditioner on a higher setting without affecting your comfort.
Cool weather - (Reverse) An upward airflow moves warm air off the ceiling area as shown in Figure 16. This allows you to set your heating unit on a lower setting without affecting your comfort.
Figure 15
Figure 16
9. Operating Your Fan
Here are some suggestions to help you maintain your fan
1. connections may become loose.
connections, brackets, and blade attachments twice a year. necessary to remove fan from ceiling.)
2. Clean your fan periodically to help maintain its new appearance over the years. Use only a soft brush or lint-free plating is sealed with a lacquer to minimize discoloration or tarnishing. Do not use water when cleaning. This could damage the motor, or the wood, or possibly cause an electrical shock.
of the fan's natural movement, some
Because
Check the support
Make sure they are secure.
cloth to avoid scratching the finish. The
(It is not
3. You can apply a light coat of furniture polish to the wood blades for additional protection and enhanced beauty. Cover small scratches with a light application of shoe polish.
4.
There is no need to oil your fan.
permanently lubricated bearings.
IMPORTANT
MAKE SURE THE POWER IS OFF AT THE
ELECTRICAL PANEL BOX BEFORE YOU
ATTEMPT ANY REPAIRS. REFER TO THE
SECTION "MAKING ELECTRICAL
CONNECTIONS"
The motor has
Care of Your Fan
10.
Problem
Solution
Fan will not start.
Fan sounds noisy.
1. Check circuit fuses or breakers.
2. Check line wire connections to the fan and switch wire connections in the switch housing. CAUTION: Make sure main power is off.
1. Make sure all motor housing screws are snug.
2. Make sure the screws that attach the fan blade bracket to the motor hub is tight.
3. Make sure wire nut connections are not rubbing against each other or the interior wall of the switch housing. CAUTION: Make sure main power is off.
4. Allow a 24-hour "breaking-in" period. Most noise associated with a new fan disappear during this time.
5. If using an optional light kit, make sure the screws securing the glassware are tight. Check that light bulb is also secure.
6. Some fan motors are sensitive to signals from solid-state variable speed controls. If you have installed this type of control, choose and install another type of control.
7. Make sure the upper canopy is a short distance from the ceiling. It should not touch the ceiling.
11.
Troubleshooting
Fan Size Speed
Volts
Amps
Watts
RPM
CFM
N.W. G.W. C.F.
Low
120
60"
High
These are approximate measures. They do not include Amps and Wattage used by the light kit.
120
0.263
0.59
13.9
70.4
55
133
2533.31
6472.21
26.40 lbs
30.14 lbs
2.60'
Specifications
12.
Manual de Instalación del Ventilador de Techo
Normas de seguridad .......................................................................................................................................................................
Cómo desembalar el ventilador ......................................................................................................................................................
Cómo instalar el ventilador .............................................................................................................................................................
Cómo operar el ventilador ..............................................................................................................................................................
Cómo cuidar del ventilador ...........................................................................................................................................................
Resolución de problemas ..............................................................................................................................................................
Especificaciones ............................................................................................................................................................................
1.
2.
3.
9.
10.
11.
12.
Tabla de Contenido
1. Para reducir el riesgo de eléctrocución, asegurarse de que la eléctricidad se ha desactivado en el cortacircuitos o caja de fusibles antes de comenzar.
2. Todo cableado debe relizarse conforme al Código Electrico Nacional y los códigos electricos locales. La instalación eléctrica debe ser relazada por un eléctricista registrado calificado.
3. ADVERTENCIA: Para reducir el riesgo de una electrocuion e incendio, no usar este ventilador con ningun dispositivo de esto s lido para control de la velocidad del ventilador.
4. ADVERTENCIA: para reducir el riesgo de incendio, descarga eléctrica o lesión personal, monte a una caja distribución marcada como "Aceptable para soporte de un ventilador de 15.9kg (35 lbs.) de peso o menos" y monte con los tornillos proporcionados con la caja de distribución. La mayoría de las cajas de conexión utilizadas para soportar artefactos de iluminación, no son aptas para colgar un ventilador y podría ser necesario cambiarlas. Debido a la complejidad de la instalación de este ventilador, se recomienda encarecidamente que la realice un electricista licenciado cualificado.
ADVERTENCIA
PARA REDUCIR EL RIESGO DE INCENDIO ELECTROCUCIÓN O
LESIONES PERSONALES. MONTAR EL VENTILADOR EN UNA CAJA DE
DISTRIBUCIÓN MARCADA CÓMO ACEPTABLE PARA SOPORTE DE
VENTILADORES.
5. La caja de distribución y la estructura de soporte deben estar montados de manera segura y deben ser capaces de soportar, de manera confiable, unminimo de 35 libras (15,9 kilogramos). Usar solamente cajas de distribución listadas por UL. marcadas "PARA SOPORTEDE
VENTILADORES".
6. EL ventilador debe estar montado con un m nimo de 7 pies (2.1m) de
espacio libre desde el borde posterior de las aspas hasta el piso.
7. Evitar colocar objetos qen interfiera el giro de las aspas.
8. Para evitar lesiones personales o da os al ventilador y otros articulos, tener
cuidado al trabajar cerca del ventilador o al limpiarlo.
9. No usar agua o detergentes al limpiar el ventilador o las aspas del ventilador. Para la mayoria de los propsitos de limpieza, un paño seco o ligeramente humedecido será apropiado.
10. Despues de realizar las conexiones eléctricas, los conductores empalmados se deben voltear hacia arriba y se deben empujar con cuidado hacia dentro de la caja de distribución. Los cables deben estar separados, con el conductor a tierra y el conductor a tierra del equipo en un lado de la caja de distribución.
11. Los diagramas eléctricos son para referencia únicamente. Los juegos de iluminación que no estén embalados con el ventilador deben estar Listados por U.L. y marcados como apropiados para ser usados con el modelo de ventilador que se está instalando. Los interruptores deberán ser Interruptores para uso general U.L. Réfierase a las instrucciónes embaladas con los juegos de iluminación e interruptores para obtener información sobre el montaje adecuado.
ADVERTENCIA:
12.
“Apropiados para su uso en lugares húmedos”.
PARA REDUCIR EL RIESGO DE LESIONES PERSONALES, NO DOBLAR LOS
SOPORTES DE LAS ASPAS (TAMBIEN LLAMADOS"REBORDES" DURANTE EL
MONTAJE O DESPUES DE LA INSTALACIÓN NO INSERTAR OBJETOS EN LA
ESTE PRODUCTO CONTIENE SUBSTANCIAS QUÍMICAS QUE SEGÚN EL
ESTADO DE CALIFORNIA CAUSA CÁNCER, DEFECTOS DE NACIMIENTO Y (O)
DAÑO AL SISTEMA REPRODUCTOR. LAVARSE BIEN LAS MANOS DESPUÉS DE
INSTALAR, MANIPULAR, LIMPIAR O TOCAR DE MANERA ALGUNA ESTE
!LEER Y GUARDAR TODAS LAS INSTRUCCIONES!
Utilice sólo kits de luz marcados como
ADVERTENCIA
TRAYECTORIA DE LAS ASPAS.
ADVERTENCIA
PRODUCTO.
NOTA
1. Normas de seguridad
2
6
9
3
7
1
4
5
Desembalar el ventilador y revisar el contenido. Debe tener los siguientes elementos:
1. Juego de aspas (5)
2. Escudete superior
3. Cubierta del hule de tubo
4. Conjunto de bola/tubo de suspensión
5. Cubridor del motor
6. Juego de soporte de fijación a aspas (5)
7. Conjunto de motor del ventilador
8. Plato de montaje
9. Caja del interruptor
10. Juego de balanceo
8
10
a
b
c
10
10. Dos bolsas de piezas pequeñas:
a. Piezas de fijación de las aspas
(16 Tornillos, 16 Arandelas de goma )
b. Piezas demontaje
(3 conectores plásticos para cables eléctricos).
c. Empacadura de goma
(Tirador para ventilador)
Cómo desembalar el ventilador 2.
Herramienta necesarias
Destornillador Phillips, destornillador normal, llave de tuercas ajustable, escalera de tijera, y cortadoras de alambre.
Angulo máximo en el techo: 18.5°
Brindar soporte fuerte
Opciones de instalación
Si no hay una caja con UL registración de montaje existente, sirvase leer las siguientes instrucciones. Desconectar el suministro de electricidad removiendo los fusibles o
Caja de distribución
desactivando los cortacircuitos.
Asegurar la caja de distribución directamente a
Figura 1
la estructura del edificio. Usar los sujetadores y meteriales de construcción apropiados. La caja de distribución y su soporte deben ser capaces de soportar completamente el peso en movimiento del ventilador (al menos 35 libras o 15.9 kgs.) No usar cajas de distribución plásticas.
ADVERTENCIA
PARA REDUCIR EL RIESGO DE INCENDIO,
ELECTROCUCIÓN O DAÑO PERSONAL,
INSTALAR EL VENTILADOR A UNA CAJA DE
DISTRIBUCION MARCADA "ACEPTADA
PARA SOPORTAR VENTILADOR" Y USAR
LOS TORNILLOS DE MONTAJE
SUMINISTRADOS CON LA CAJA DE
DISTRIBUCION
Figura 2
Caja de distribución
3. Cómo instalar el ventilador
Soporte de montaje
Figura 3
Caja de distribución embutida
Nota: Ud. Puede necesitar una barra de extension para mantener la distancia apropiada de las aspas cuando la instalación se efectúe en un techo inclinado.
Figura 4
Caja de distribución
Para colgar su ventilador donde ya existe una instalación pero no una viga de techo, es possible que se necesite una instalación de barra de suspención como se muestra la Figura 4 (disponible en su distribuidor ).
Colocación del ventilador
RECUERDE desconectar la alimentación.
Siga estos pasos para colocar correctamente el ventilador:
Paso 1. Retire la tapa embellecedora del fondo del cobertor girando la tapa en sentido de las agujas del reloj. (Fig. 5)
Paso 2. Quite el soprte de montaje de la cubierta quitando 1 de los 2 tornillos de la parte inferior del soprte de montaje y aflojando el otro media vuelta desde la cabeza del tornillo. A continuación, gire la soprte de montaje en sentido contrahorario para quitar la cubierta. (Fig. 5)
Paso 3. Pase los hilos de 120 voltios a través del agujero central del soporte de suspensión del techo tal y cómo se muestra en la. (Fig. 6)
Paso 4. Fije el soporte de montaje a la caja del techo con los tornillos y arandelas suministradas en la caja.
Paso 5. Retire el pasador de suspensión, el pasador de bloqueo y el conjunto de tornillos y de la parte superior del ensamblaje del motor.
Paso 7. Alinee los agujeros de la parte inferior de la barra con los agujeros del cuello en la parte superior de la caja del motor (Fig. 7) Introduzca con cuidado el pasador de suspensión a través de los agujeros del cuello y de la barra. Tenga cuidado de que el pasador no se atasque con los hilos de dentro de la barra. Introduzca el pasador de bloqueo a través del agujero cercano al extremo del pasador de suspensión hasta que quede en la posición de bloqueo, tal y cómo se especifica en el circulo de la Fig. 7. Coloque la cubierta de hule sobre la esfera de colgaje.
ADVERTENCIA
SI NO INSTALA EL PASADOR
CORRECTAMENTE TAL Y CÓMO SE
ESPECIFICA EN EL PASO 7, EL
VENTILADOR PODRIA AFLOJARSE E
INCLUSO CAER.
Paso 8. Apriete bien los dos tornillos de la parte superior del motor. (Fig. 7)
Paso 9. Coloque la bola de la barra en la ranura del soporte de suspensión.
Soporte de montaje
Caja de eléctrica aprobada por CUL
Soporte de montaje
Gancho
Figura 6
Cables del motor
Cubierta de hule para el tubo de montaje
Ensamblaje de bola/barra
Caja de techo
Pasador de bloqueo
Apriete bien los tornillos
Hilos de 120V
Arandelas
Tornillos de montaje (suplidos en la caja eléctrica)
Pasador en posición de bloqueo
Tapa de la caja
Voluta decorativa
Pasador del soporte colgante
Collar del motor
Paso 6. Guíe los cables que salen de la parte superior del motor del ventilador a través de la voluta decorativa, tapa de la cubierta, cubierta y luego a traves de la bola/varilla. (Fig. 7)
Figura 5
Escudete de techo
Circulo de escudete
Figura 7
4.
Realizar las Conexiones Eléctricas
RECORDAR desconectar la corriente.
Si no tiene los conocimientos necesarios sobre instalaciones eléctricas o experiencia, deje que sea un electricista profesional quien realice la instalación.
Siga los pasos siguientes para conectar el ventilador al cableado de la casa. Utilice las tuercas de conexión de cable incluidas con su ventilador. Fije los conectores con cinta aislante. Asegúrese de no dejar conexiones o hilos sueltos.
Paso 1. Conecte el conductor de tierra de la fuente de 120V (puede que sea un cable pelado o un cable con aislante de color verde) al cable o cables verdes del ventilador (Figura 8).
Paso 2. Conecte el cable blanco del motor del ventilador al cable de corriente blanco (neutro) con una tuerca de cable (Figura 8).
Paso 5. Gire las conexiones de tuerca de cable hacia arriba, repartiéndolas de manera que el cable verde (tierra) quede en un lado de la toma de corriente y los cables blanco, negro y azul en el otro lado, y presione con cuidado hacia arriba en la toma de corriente.
COMPRUEBE SI TODAS LAS CONEXIONES
ESTÁN SEGURAS, INCLUYENDO LA DE
TIERRA, Y QUE NO HAYA CABLES PELADOS
EXPUESTOS A LAS TUERCAS DE LOS
CABLES. EXCEPTO EL CABLE DE TIERRA.
LOS DIAGRAMAS ELÉCTRICOS SIRVEN SÓLO
REFERENCIA.86223&,21$/'(&8$/48,(5
&21-8172'(/8='(%((67$55(*,675$'2325
8/<0$5&$'2$'(&8$'$0(17(3$5$(/862
PARA REDUCIR EL RIESGO DE INCENDIO O DESCARGA ELÉCTRICA, NO UTILICES ESTE
VENTILADOR CON NINGÚN DISPOSITIVO DE
CONTROL DE VELOCIDAD DE ESTADO SÓLIDO.
ADVERTENCIA
ADVERTENCIA
'((67(9(17,/$'25
ADVERTENCIA
COMO
CIRCUITO DE A LIMENTACIÓN
Conductor a tierra
BLANCOBLANCO
NEGRO
Caja de distribución
Hilo de tierra verde
AZUL
NEGRO
VERDE
Conexión a tierra para la barra descendente
AZUL
NEGRO BLANCO
BLANCO
Paso 3. Conecte el cable negro del motor del ventilador al cable de corriente negro (activo) con una tuerca de cable ).
Paso 4. Conecte el cable azul para el kit de luz al cable de corriente negro de la carcasa.
5.
Figura 8
El diagrama indica el cableado para el juego opcional de iluminación.
Terminando la Instalación
Paso 1. Meta las conexiónes en forma ordenada
adentro de la toma de corriente.
Paso 2. Deslice la cubierta hacia arriba hacia el soporte de montaje y coloque el agujero de posición de la cubierta sobre el tornillo del soporte de montaje, gire la cubierta hasta que quede encajada en su lugar en la sección estrecha de los agujeros de posición. (Fig. 9)
Paso 3. Alinee el agujero circular de la cubierta con el agujero restante en el soporte de montaje, fíjelo apretando los dos juegos de tornillos. Nota: Ajuste los tornillos de la cubierta hasta que la cubierta y la tapa de la cubierta queden ajustadas.
ASEGURARSE DE QUE LA LENGUETA
LOCALIZADA EN LA PARTE INFERIOR DEL
SOPORTE DE SUSPENSIÓN ESTÉ ASENTADA
CORRECTAMENTE EN LA RANURA DE BOLA
DE SUSPENSIÓN ANTES DE FIJAR EL
ESCUDETE AL SOPORTE. EL NO AJUSTAR
CORRECTAMENTE LA LENGUETA EN LA
RANURA PODRÍA CAUSAR DAÑO AL
ADVERTENCIA
CABLEADO ELÉCTRICO.
Caja de salida
Abrazadera de soporte
Tornillos
Cubierta
Anillo para la cubierta
Figura 9
Instalacion de las Aspas
PRECAUCIÓN: Quite los 5 montajes de goma
del paquete y retírelos antes de la instalación.
Paso 1. Se pegan las palas a los soportes usando los tornillos y las arandelas de goma provistos como indicado en Fig 10. Inserta un tornillo en el soporte sin apretarlo. Repite el paso por los otros 2 tornillos y arandelas.
Paso 2. Apreta todos los tornillos fimemente empezando con el tornillo cortador. Asgúrate de que la pala esté recta.
Paso 3. Alinie los agujeros de la abrazadera con los del motor y asegurela con los tornillos suministrados. Apriete bien los tornillos. (Figura
11).
Tornillos
Arandelas de goma
Soporte de pala
Pala
Figura 10
Motor
Palas asamblea
Figura 11
Tornillos
6.
Balanceo de las Aspas
1. Verificar que todos los tornillos de aspas y de soportes de aspas estén seguros.
2. La mayoría de los problemas de oscilación se originan cuando los niveles de las aspas son desiguales. Revisar esté nivel por medio de seleccionar un punto del techo por encima de la punta de una de las aspas. Medir esta distancia como se muestra en la Figura 12. Rotar el ventilador hasta que la siguiente aspa esté ubicada para medición. procedimiento para cada aspa. Las medi repetir el das hacer fucional deben mantenerse dentro de 1/8 pulgadas (3mm).
3. Usar el juego de balanceo de aspas incluido
si aún se puede notar la oscilación.
4. Si la oscilación de las aspas todavía se puede notar, el intercambio de dos aspas adyacentes (lado a lado) puede redistribuir el peso y es posible que resulte en un funcionamiento más uniforme.
PARA REDUIR RIESGO DE LESIONES
PERSONALES. NO DOBLAR LOS SUJET
ADORES DE ASPAS MIENTRAS SE
BALANCEO DE LAS ASPAS O SU
LIMPIEZA. NO INSERTAR OBJETOS
EXTRANOS ENTRE LAS ASPAS DEL
Figura 12
ADVERTENCIA
REALIZA LA INSTALACIÓN. EL
VENTILADOR EN ROTACIÓN.
En contacto con el techo
Instalación de la Placa de Montaje
Paso 1.
Quite 1 de los 3 tornillos del anillo de montaje y afloje los otros 2 tornillos. (No los quite)
Paso 2.
Coloque los agujeros del plato de montaje en los 2 tornillos previamente aflojados del anillo de montaje, gire el plato de montaje hasta que quede fijo en su lugar en la parte estrecha de los agujeros. Asegúrela apretando los 2 tornillos aflojados y también el que quitó anteriormente. (Fig. 13)
Anillo de montaje
Placa de montaje
Figura 13
Tornillos
7.
Instalación del Cubierta de Interruptores
Paso 1.
Quite 1 de los 3 tornillos del plato de montaje y afloje los otros 2 tornillos. (No los quite)
Paso 2.
alambres.
Paso 3.
interruptor en los 2 tornillos previamente aflojados del plato de montaje, gire el caja del interruptor hasta que quede fijo en su lugar en la parte estrecha de los agujeros. Asegúrela apretando los 2 tornillos aflojados y también el que quitó anteriormente. (Figure 13)
Monte el enchufe de conexión de los
Coloque los agujeros del caja del
Connector de alambres
Caja del interruptor
Figura 14
Plato de montaje
Tornillos
8.
Conecte la alimentación y compruebe el funcionamiento del ventilador. Hay 2 cordones en el ventilador: Cordán para 3 velocidades- controla la velocidad del ventilador como sigue: 1 tiron-Alta, 2 tirones-Media, 3 tirones-Baja y 4 tirones-Apagado.
La configuración de la velocidad para temperatura fría o templada depende de factores como el tama o de la habitación, altura del techo, número de ventiladores, etc.
El interruptor deslizante controla las direcciones: adelante (interruptor isquierda) o atrós (interruptor derecha).
ESPERE A QUE EL VENTILADOR PARE ANTES
NOTA
DE CAMBIAR LA POSICIÓN DEL
INTERRUPTOR DESLIZANTE.
Clima templado - (sentido contrahorario) el flujo del aire hacia abajo crea un efecto enfriador. (Fig.
15) Esto le permite colocar su aire acondicionado en un lugar más alto sin que afecte a su confort.
Clima frío - (sentido horario) el flujo del aire hacia arriba quita el aire caliente del techo (Fig.
16). Esto le permite colocar el radiador en un lugar más bajo sin que afecte a su confort.
Figura 15
Figura 16
9. Cómo Operar el Ventilador
He aqui algunas sugerencias para ayudarle el mantenimiento del ventilodor.
1. Debido al movimiento natural del ventilador, algunas conexiones se podrian aflojar. Examinar las conexiones del soporte, soportes, y accessorios de las aspas dos veces al año. Asgurarse de que estén seguros. (No es necesario retirar el venitlador del techo).
3. Se puede aplicar una capa ligera de pulidor para muebles a las aspas de madera para brindar protección adicional y realzar su belleza. Cubrir los rayones pequeños con una ligera aplicación de betún para calzado.
4. No hay necesidad de aceitar el ventilador. El motor tiene cojinetes permanentemente lubricados.
2. Limpiar el ventilador periódicamente para ayudar a mantener su apariencia de nuevo con el transcurso del tiempo. Usar solamente un cepillo suave o paño sin hilas para evitar rayar el acadado. El recubrimiento metálico se sella con una laca para minimizar la decoloración o manchado. No usar agua al limpiarlo. madera, o posiblemente causar choque eléctrico.
ASEGURARSE DE QUE LA ELECTRICIDAD
ADVERTENCIA
ESTÉ DESACTIVADA EN EL TABLERO DE
DISTRIBUCIÓN ELÉCTRICA ANTES DE INTENTAR CUALQUIER REPARACIÓN
REFERIRSE A LA SECCIÓ "CÓMO
EFECTUAR CONEXIONES ELÉCTRICAS"
Cómo cuidar del ventilador
10.
Problema
Solución
El ventilador no arranca.
El ventilador hace mucho ruido.
1. Revisar los fusibles o interruptores de circuitos.
2. Verificar las conexiones de cables de linea al ventilador y conexiones de cable del interruptor. PRECAUCIÓN: Asegurarse de que la fuente pricipal de electricidad esté desactivada.
1. Asegurarse de que todos los tornillos de la cubierta del motor estén ajustados.
2. Asegurarse de que los tornillos que sujetan el soporte de aspas del ventilador al eje del motor estén apretados.
3. Asegurarse de que las conexiones de tuercas para cable no esten rozando unas contra otras o contra la pared interior de la cubierta protectora del interruptor. PRECAUCIÓN: Asegurarse de que la fuente principal de electricidad esté desactivada.
4. Permitir un período de "desgaste" de 24 horas. La moyaría de los ruidos asociados con un ventilador nuevo desaparecen durante este tirmpo.
5. Si se está usando un juego opcional de iluminación para el venitlador de techo, aseguarse de que los tornillos que aseguran el vidrio estén apretados. Asimsmo, verificar que la bombilla esté seg ura.
6. Algunos motores son señsibles a las señales provenientes de controles de velocidad variable de estado sólido. Si tiene instalado este tipo de control, elegir e instalar otro tipo.
7. Asegurarse de que el escudete superior esté a una corta distancia del techo. No debe hacer contacto con el techo.
11.
Resolución de problemas
Tamaño del Ventilador
Velocidad Voltios
Amperios
Vatios
RPM CFM N.W. G.W. C.F.
60"
(152 cm)
Estas son mediciones aproximadas. No incluyen los Amperios y vatios usado por el juego de iliminación.
Baja
Alta
120
120
0.263
0.59
13.9
70.48
55
133
2533.31
6472.21
26.40 lbs
30.14 lbs
2.60'
Especificaciones
12.
Loading...