SUBMITTAL FOR CHARLOTTE PIPE®
PVC SCHEDULE 40 SOLID WALL PIPE AND PVC DWV FITTING SYSTEM
Date: ________________
Job Name: ______________________________ Location: _______________________________
Engineer: _______________________________ Contractor: ______________________________
Scope:
This specication covers PVC Schedule 40 solid wall pipe and PVC DWV ttings used in sanitary drain, waste and
vent (DWV), sewer and storm drainage applications. This system is intended for use in non-pressure applications
where the operating temperature will not exceed 140° F.
Specication:
Pipe shall be manufactured from virgin rigid PVC (polyvinyl chloride) vinyl compounds with a cell class of 12454 as
identied in ASTM D 1784. PVC Schedule 40 pipe shall be Iron Pipe Size (IPS) conforming to ASTM D 1785 and
ASTM D 2665. Injection molded PVC DWV ttings shall conform to ASTM D 2665. Fabricated PVC DWV ttings shall
conform to ASTM F 1866. All pipe and ttings shall be manufactured in the United States. All systems shall utilize a
separate waste and vent system. Pipe and ttings shall conform to NSF International Standard 14.
Installation:
Installation shall comply with the latest installation instructions published by Charlotte Pipe and Foundry and shall
conform to all applicable plumbing, re, and building code requirements. Buried pipe shall be installed in accordance
with ASTM D 2321 and ASTM F 1668. Solvent cement joints shall be made in a two-step process with primer
conforming to ASTM F 656 and solvent cement conforming to ASTM D 2564. The system shall be protected from
chemical agents, re-stopping materials, thread sealant, plasticized-vinyl products or other aggressive chemical
agents not compatible with PVC compounds. The system shall be hydrostatically tested after installation.
WARNING! Never test with or transport/store compressed air or gas in PVC pipe or ttings. Doing so can result in
explosive failures and cause severe injury or death.
Referenced Standards:
ASTM D 1784: Rigid Vinyl Compounds
ASTM D 1785: PVC Plastic Pipe, Schedule 40
ASTM D 2665: PVC Drain, Waste and Vent Pipe and Fittings
ASTM D 2564: Solvent Cements for PVC Pipe and Fittings
ASTM D 2321: Underground Installation of Thermoplastic
Pipe (non-pressure applications)
ASTM F 656: Primers for PVC Pipe and Fittings
ASTM F 1668: Procedures for Buried Plastic Pipe
ASTM F 1866: Fabricated PVC DWV Fittings
NSF Standard 14: Plastic Piping Components and
Related Materials
Coupling
Cleanout Tee
w/Plug
Not all tting patterns shown
Quarter Bend
Combination Wye
& Eighth Bend
Eighth Bend
Closet FlangeP-Trap
Double
Sanitary Tee
PVC Schedule 40 DWV Pipe
PVC Schedule 40 DWV Pipe
PVC SCHEDULE 40 (WHITE) PLAIN END PVC 1120 ASTM D 2665
PVC SCHEDULE 40 (WHITE) PLAIN END PVC 1120 ASTM D 2665
PART NO. NOM. SIZE UPC # QTY. PER AVG. OD MIN. WALL WT. PER 100 FT.
611942- SKID (IN.) (IN.) (LBS.)
PVC 7100* 11⁄4”x10’ 03945 2120’ 1.660 .140 42.4
PVC 7100* 1
PVC 7112* 1
PVC 7112* 1
PVC 7200* 2”x10’ 03949 1110’ 2.375 .154 69.5
PVC 7200* 2”x20’ 03950 2220’ 2.375 .154 69.5
PVC 7300* 3”x10’ 03951 1130’ 3.500 .216 144.2
PVC 7300* 3”x20’ 03952 1000’ 3.500 .216 144.2
PVC 7400
PVC 7400
PVC 7500
PVC 7600
PVC 7600
PVC 7800
PVC 7800
PVC 7910
PVC 7912
PVC 7914
PVC 7916
* Dual Marked ASTM D 1785 & ASTM D 2665.
†
Triple Marked ASTM D 1785 & ASTM D 2665 & ASTM F 480.
1
⁄4”x20’ 03946 4240’ 1.660 .140 42.4
1
⁄2”x10’ 03947 1650’ 1.900 .145 51.8
1
⁄2”x20’ 03948 3300’ 1.900 .145 51.8
†
4”x10’ 03953 670’ 4.500 .237 205.5
†
4”x20’ 03954 1340’ 4.500 .237 205.5
†
5”x20’ 04837 760’ 5.563 .258 272.5
†
6”x10’ 03955 330’ 6.625 .280 361.2
†
6”x20’ 03956 660’ 6.625 .280 361.2
†
8”x10’ 13087 180’ 8.625 .322 543.6
†
8”x20’ 03958 360’ 8.625 .322 543.6
†
10”x20’ 03959 220’ 10.750 .365 770.7
†
12”x20’ 03961 120’ 12.750 .406 1019.0
†
14”x20’ 04862 60’ 14.000 .437 1205.0
†
16”x20’ 04918 60’ 16.000 .500 1575.7
Charlotte Pipe and Foundry Company • P.O. Box 35430 Charlotte, NC 28235 • (800) 438-6091 • www.charlottepipe.com
Charlotte Pipe and Charlotte Pipe and Foundry Company are registered trademarks of Charlotte Pipe and Foundry Company.
FO-SUB-PVC-DWV (10-17-19)
PVC and ABS DWV Fittings
PART NO. 107
Flush Bushing
2
(PVC)
(ABS)
2
(PVC)
2
(ABS)
11⁄
13⁄
13⁄
121⁄
27⁄
15⁄
(PVC)
(PVC)
(PVC)
11⁄
(PVC)
(PVC)
(PVC)
21⁄
(PVC)
SPIGOT X HUB
3
5
5
1
25
23
47⁄
35⁄
55⁄
45⁄
11⁄
SIZE C
11⁄
2
x 11⁄4
2 x 11⁄4
2 x 11⁄
2 x 11⁄2
3 x 11⁄
3 x 11⁄
3 x 2
(PVC)
3 x 2 (ABS)
4 x 2
(PVC)
4 x 2 (ABS)
4 x 3
(PVC)
4 x 3 (ABS)
6 x 4
(PVC)
6 x 4 (ABS)
8 x 4
(PVC)
8 x 6
(PVC)
10 x 4**
10 x 6**
10 x 8
12 x 4**
12 x 6**
12 x 8
12 x 10
⁄
16
⁄
16
⁄
16
1
⁄
8
⁄
32
7
⁄
8
⁄
32
8
16
1
⁄
2
1
⁄
4
4
32
8
8
16
32
2
32
32
2
2
** Assembled from two molded components
Note: If PVC or ABS is not listed for a specic size, that size tting is available in PVC and
ABS materials, and the dimensions listed are the same for both materials.
20