SUBMITTAL FOR CHARLOTTE PIPE®
PVC CELLULAR (FOAM CORE) PIPE AND PVC DWV FITTING SYSTEM
Date: ________________
Job Name: ______________________________ Location: _______________________________
Engineer: _______________________________ Contractor: ______________________________
Scope:
This specication covers PVC cellular (foam core) pipe and PVC DWV ttings used in sanitary drain, waste and vent
(DWV), sewer, and storm drainage applications. This system is intended for use in non-pressure applications where
the operating temperature will not exceed 140° F.
Specication:
Pipe shall be manufactured from virgin rigid PVC (polyvinyl chloride) vinyl compounds with a cell class of 11432 as
identied in ASTM D 4396. Fittings shall be manufactured from virgin rigid PVC (polyvinyl chloride) vinyl compounds
with a cell class of 12454 as identied in ASTM D 1784.
PVC cellular core pipe shall be Iron Pipe Size (IPS) conforming to ASTM F 891. Injection molded PVC DWV ttings
shall conform to ASTM D 2665. Farbricated PVC DWV ttings shall conform to ASTM F 1866. All systems shall utilize
a separate waste and vent system. All pipe and ttings shall be manufactured in the United States. Pipe and ttings
shall conform to NSF International Standard 14.
Installation:
Installation shall comply with the latest installation instructions published by Charlotte Pipe and Foundry and shall
conform to all applicable plumbing, re, and building code requirements. Buried pipe shall be installed in accordance
with ASTM D 2321 and ASTM F 1668. Solvent cement joints shall be made in a two-step process with primer
conforming to ASTM F 656 and solvent cement conforming to ASTM D 2564. The system shall be protected from
chemical agents, re-stopping materials, thread sealant, plasticized-vinyl products or other aggressive chemical
agents not compatible with PVC compounds. The system shall be hydrostatically tested after installation.
WARNING! Never test with or transport/store compressed air or gas in PVC pipe or ttings. Doing so can result in
explosive failures and cause severe injury or death.
Referenced Standards:
ASTM D 4396: Compounds for Cellular Core
ASTM F 891: Co-extruded PVC Pipe with Cellular Core
ASTM D 2665: PVC Drain, Waste and Vent Fittings
ASTM D 2564: Solvent Cements for PVC Pipe and Fittings
ASTM D 2321: Underground Installation of Thermoplastic
Pipe (non-pressure applications)
ASTM F 1668: Procedures for Buried Plastic Pipe
ASTM F 1866: Fabricated PVC DWV Fittings
NSF Standard 14: Plastic Piping Components and
Related Materials
Coupling
Cleanout Tee
w/Plug
Not all tting patterns shown
Quarter Bend
Combination Wye
& Eighth Bend
Eighth Bend
Double
Sanitary Tee
Closet FlangeP-Trap
PVC Foam Core Pipe
PVC Schedule 40 DWV Pipe
(For Non-Pressure Applications)
PVC SCHEDULE 40 FOAM CORE (WHITE) PLAIN END ASTM F 891
MIN. WT. PER
PART NO. NOM. SIZE UPC # QTY. PER AVG. OD WALL 100 FT.
611942- SKID (IN.) (IN.) (LBS.)
PVC 4112 11⁄2” x 10’ 04178 1650’ 1.900 0.145 32.3
1
PVC 4112 1
PVC 4200 2” x 10’ 04174 1110’ 2.375 0.154 43.9
PVC 4200 2” x 20’ 04173 2220’ 2.375 0.154 43.9
PVC 4300 3” x 10’ 03934 1130’ 3.500 0.216 89.7
PVC 4300 3” x 20’ 03935 1000’ 3.500 0.216 89.7
PVC 4400 4” x 10’ 03936 670’ 4.500 0.237 123.8
PVC 4400 4” x 20’ 03937 1340’ 4.500 0.237 123.8
PVC 4600 6” x 10’ 03938 330’ 6.625 0.280 235.0
PVC 4600 6” x 20’ 03939 660’ 6.625 0.280 235.0
PVC 4800 8” x 20’ 03941 360’ 8.625 0.322 371.0
PVC 4910 10” x 20’ 03942 220’ 10.750 0.365 566.3
PVC 4912 12” x 20’ 03943 120’ 12.750 0.406 700.0
⁄2” x 20’ 04177 3300’ 1.900 0.145 32.3