Charles Bentley & Son CI User Manual

FERRORESONANT BATTERY CHARGERS
C-CHARGER®CI SERIES
SINGLE-RATE FLOAT BATTERY CHARGERS
Safe to say, there’s no other float charger built like a C-Charger from Charles Industries. Rugged #304 grade stainless steel forms the sturdy housing that withstands virtually all environmental challenges; including heat, humidity, vibration, and other stress factors. The steel cover is hinged to ease installation.
Electrically, the C-Charger is a paragon of efficiency and simplicity. It uses a ferroresonant transformer with integral self-regulation. It has been intelligently designed to be completely devoid of any complicated switching circuits that could possibly burn out. There are no tubes nor delicate electronics to fail or to cause radio frequency interference (RFI). By simplifying our design, Charles has
increased reliability without sacrificing performance or usability.
Voltage output to the batteries remains at a safe and constant DC level from full load to no load, even if AC power runs as high as 132 VAC or as low as 108 VAC. This automatic voltage regulation relieves strain on internal electrical components and lengthens the lifespan of the unit. All components are designed to operate safely and continuously in an ambient temperature as high as 122º F.
CI Series Battery Chargers are available in 12, 24 and 32 Volt models and may be used with both lead acid and nickel cadmium batery banks.
Features
UL Listed
• DC ammeter
• Terminal board
• Sealed silicon diodes
• Cannot discharge battery during AC failure
• Stainless steel for corrosion resistance
• Ferroresonant transformer for reliability
• Isolated output: no direct AC to DC connection
• Isolated positive and negative: can be used as a negative voltage charger
• Two year limited warranty
Ordering Information
Specifications
AC Input 108-132 volts/60 Hz (220 volts/50 Hz optional)
Operating Temperature 0º to 50º C (32º to 122º F)
Storage Temperature -20º to 60º C (-4º to 140º F)
Cooling Convection
DC Output
- Float 2.16 VPC for lead acid, 1.45 VPC for nickel cadmium
- Equalize 2.33 VPC for lead acid, 1.55 VPC for nickel cadmium
Current Limit Approximately 135%
Enclosure 304 stainless steel hinged cover to facilitate installation
0 102030405060708090100
% OF RATED CHARGING CURRENT (AMPS)
VPC
2.5
2.4
2.3
2.2
2.1
2.0
1.9
1.8
Typical Output Curve
Contact your Charles sales representative for specific product information.
When ordering, please specify:
1. Model number
2. AC input: voltage & frequency
3. Battery type and number of cells
4. Ampere-hour capacity of battery
5. Recharge time desired
6. Description of load
Charles Industries, Ltd. Industrial Group 5600 Apollo Drive Rolling Meadows, IL 60008 USA
Voice: (847) 806-6300 Fax: (847) 806-6352 Web: www.charlesindustries.com E-mail: mktserv@charlesindustries.com
D-IND001-B01 Rev. 3
IS0 9000
REGISTERED
QUALITY SYSTEM
12 Volt
Model
Number
Height Inches
Width
Inches
Depth
Inches
Approx.
Weight
D.C. Output
Amps
System Voltage
24 Volt
32 Volt
CI1205C* 5 12 9.5 7.5 5 9 CI1210C 10 12 9.5 7.5 6.25 13 CI1215A 15 12 9.5 7.5 6.25 15 CI1220C 20 12 9.5 7.5 6.25 17 CI1230C 30 12 11.5 9 8.75 20 CI1240C 40 12 11.5 9 8.75 30 CI1260C** 60 12 13 11.5 10.25 38
CI2405C* 5 24 9.5 7.5 5 12 CI2410C 10 24 9.5 7.5 6.25 17 CI2420C 20 24 11.5 9 8.75 30 CI2430C** 30 24 13 11.5 10.25 38 CI2440C** 40 24 13 11.5 10.25 46
CI3205C* 5 32 9.5 7.5 5 15 CI3220C** 20 32 13 11.5 10.25 38 CI3230C** 30 32 13 11.5 10.25 46 CI3240C** 40 32 13 11.5 10.25 60
Consult Charles Industries for additional models
*DC Ammeter Only **Switch Optional
Loading...