CHARDER MEDICAL HM80M Instruction Manual

0
HM80M Baby Length
Height measurement
Please keep the instruction manual at hand all the time for future reference.
1
TABLE OF CONTENTS
PREFACE.....................................................................................................2
CLEANING..................................................................................................2
MAINTENANCE.........................................................................................2
SAFETY INSTRUCTIONS.........................................................................2
WARRANTY ...............................................................................................3
EXPLANATION OF THE GRAPHIC SYMBOLS.....................................5
2
PREFACE
Thank you for choosing CHARDER MEDICAL product. All features of this product were designed to state of the art and are optimized for simple and straightforward use. If you have any queries or experience any problems not addressed in the operating instructions, please contact your CHARDER MEDICAL service partner, or visit us on the Internet at www.chardermedical.com
CLEANING
To clean the measuring rod as required using cleaning agent or disinfectant agent.
MAINTENANCE
The device does not require any routine maintenance. Daily wipe with water or cleaning agent to keep cleaning and disinfected is recommended.
SAFETY INSTRUCTIONS
Proper use
This height measuring rod is used to determine the height of persons while standing upright, or of lying babies, according to its model, in medical treatment localities. This height measuring rod is suitable to detect, prevent and survey diseases. Ensure that the height measuring rod may only come into contact only with uninjured skin.
Improper Use
The structure of the height measuring rod may not be modified. This may result in incorrect measuring results, safety-related defects as well as destruction. The height measuring rod may only be used according to the described conditions.
Safety Instructions
3
Observe operating instructions. Please use no other than the supplied fixtures for mounting. During assembling, ensure that screws are tightened properly and that the height measuring rod has been assembled correctly. To prevent risk of injury, ensure that the head stop is returned to folded-in position after each use. The body height measuring emits only reliable values, when the back and the head are straightly aligned, nevertheless the body height of a person may change about some cm during a day. Never leave a baby on the surface unsupervised When sliding the rod, ensure that baby is safely on the measuring area.
WARRANTY
A two-year warranty from date of delivery applies to defects attributable to poor materials or workmanship. Defects, which come under warranty, will be made good for the customer at no charge on production of the receipt. No further claims can be entertained. The costs of transport in both directions will be borne by the customer should the equipment be located anywhere other than the customer’s premises. In the event of transport damage, claims under warranty can be honored only if the complete original packaging was used for any transport and the device secured and attached in that packaging just as it was when originally packed. All the packaging should therefore be retained. A claim under warranty will not be honored it the equipment is opened by persons not expressly authorized by Charder to do so. We would ask our customers abroad to contact their local sales agent in the event of a warranty matter.
PLEASE VISIT WWW.CHARDERMEDICAL.COM FOR MORE INFORMATION.
4
Measuring range: 35 ~ 80cm / 13
4
3
~ 31
2
1
inch
Graduations: 1mm /
16
1
inch
Dimensions (WxHxL): 29 x 7 x 62 cm Weight: 700g Accuracy: ±10mm Temperature range: 5 up to 35 Medical product in accordance with Directive 2007/47/EC: Class I
No.
Items Spec. Qty.
1
HM80M mechanical baby
length
1
2
User manual IN-1576 1
4
Bracket set for baby
tray(option)
SS-5611 1
5 Bracket set for MS2400 (option)
SS-5621 1
6 Bracket set for MS5900 (option)
SS-6111 1
SPECIFICATION
5
EXPLANATION OF THE GRAPHIC SYMBOLS
SN-T13000001
Designation of the serial number of every device, applied at the device.
(Number as an example)
“Please note the accompanying documents“ or “Observe operating instructions”
Charder Electronic Co., Ltd.
No.103, Guozhong Rd., Dali Dist., Taichung City 412, Taiwan (R.O.C.)
Identification of manufacturer of medical product including address
Dispose of old appliances separately from your household waste !l! Instead, take them to communal collection points.
6
Carefully read this operation manual
before setup and commissioning, even if you are already familiar with Charder scales.
Transport and storage temperature limit indicating the upper and the lower limit (Transport and storage temperature on packaging)
+60°C
-20°C
7
If head stop is loose please re-assemble it as below.
1. Lay the baby at flat platform. The baby’s head must be at the head stop of HM80M. Gently keep the baby’s knees down onto the platform. Keep the baby still on the platform with left hand.
TROUBLE SHOOTING
1.
2. 3.
HOW TO MEASURE
8
2. Using right hand to push the foot stop in the direction of the baby’s feet until foot stop touches the soles of
baby’s feet.
3. Read off the length of the baby from the marking on measuring rod.
Bracket for assembly with scale is an optional accessory.
1. Fix bracket on the tray with bracket screws x 2.
ASSEMBLY WITH REMOVABLE BABY TRAY
SS-5611 bracket
9
2. Press the buckle to secure HM80M is welled installed.
3. Assembly completed
10
1. Remove bracket holder cover.
2. Take off bracket holder cover.
ASSEMBLY WITH MS5900 BABY SCALE
11
3. Fixing bracket with two screws.
4. Assemble baby height rod with the bracket carefully until click.
Photo shown above is indicative only.
FOR HM 80M & HM80D
Slide
SS-6111 bracket
12
5. Install the bracket holder cover.
1. Place the bracket and tighten the screw with screw driver.
HM 80D
HM 80M
Fix the bracket here for the scale with rubber head pad
rubber head pad
rubber head pad
ASSEMBLY WITH MS2400 BABY SCALE
SS-5621 bracket
13
2. Assemble baby height rod with the bracket carefully until click.
Fix the bracket here for the scale without rubber head pad
14
NOTE
15
Manufacturer’s Declaration of Conformity
This product has been manufactured in accordance with the harmonized European standards, following the provisions of the below stated directives:
93/42/EEC as amended by
2007/47/EC Medical Device Directive
Please see separate document showing on sticker of device for above CE marking.
Authorized EU Representative:
Manufactured by:
Charder Electronic Co., Ltd.
No.103, Guozhong Rd., Dali Dist., Taichung City 412 ,Taiwan (R.O.C.)
FDA no.: D072478
IN-1576 [9065G] 06/2016