Charder MS 4600, MS 4610 User Manual

35
Manufacturer’s Declaration of Conformity
This product has been manufactured in accordance with the harmonized European standards, following the provisions of the below stated directives:
2007/47/EC Medical Device Directive
2014/31/EU Non-
automatic Weighing Instruments
Directive
Please see separate document showing on sticker of device for above CE marking.
Authorized EU Representative:
Manufactured by:
Charder Electronic Co., Ltd.
No.103, Guozhong Rd., Dali Dist., Taichung City 412,Taiwan (R.O.C.)
FDA no.: D051882
IN-1012 [7025L] 04/2016
- 0 -
MS 4600/4610
USER MANUAL
Please keep the instruction manual at hand all the time for future reference.
- 1 -
TABLE OF CONTENTS
PREFACE................................................................................................. 2
GENERAL INFORMATION .................................................................... 2
SAFETY INSTRUCTION.........................................................................2
ENVIRONMENTAL................................................................................. 3
CLEANING.............................................................................................. 3
MAINTENANCE ..................................................................................... 3
WEIGHING OPERATION........................................................................ 4
WARRANTY-LIABILITY........................................................................ 4
DISPOSING OF THE SCALE.................................................................. 5
EXPLANATION OF THE GRAPHIC SYMBOLS.................................... 6
EMC guidance and manufacturer's declaration.......................................... 8
SPECIFICATION.................................................................................... 13
MEDICAL SCALE MODELS APPROVAL LIST................................... 14
PANEL.................................................................................................... 15
KEY FUNCTION................................................................................... 16
LCD DISPLAY SYMBOLS.................................................................... 18
USING SCALE....................................................................................... 19
USING HOLD FUNCTION.................................................................... 19
USING TARE FUNCTION..................................................................... 21
MS 4610- STORING AND RE-CALLING PRE-TARE WEIGHT.......... 22
USING BMI FEATURE.......................................................................... 25
MS4610 & 4600: SET-UP....................................................................... 27
PRINT FUNCTION................................................................................ 28
INSTRUCTION FOR CHARGING AND CONNECTING..................... 31
INSTRUCTION FOR REPLACING BATTERIES.................................. 32
ERROR MESSAGE................................................................................ 33
34
NOTE
33
ERROR MESSAGE
- 2 -
PREFACE
Thank you for choosing CHARDER MEDICAL product. All features of this product were designed to state of the art and are optimized for simple and straightforward use. If you have any queries or experience any problems not addressed in the operating instructions, please contact your CHARDER MEDICAL service partner, or visit us on the Internet at
www.chardermedical.com
GENERAL INFORMATION
We strongly recommend you use the scales on flat and hard surface. Any soft surface, like carpet will cause inaccuracy.
SAFETY INSTRUCTION
Before putting the device into use, please read with care the information given in the Operating Instructions. They contain important instructions for installation, proper use and maintenance of the device. The manufacturer shall not be liable for damages arising out of failure to heed the following instructions:
When using electrical components under increased safety
requirements, always comply with the appropriate regulations.
Improper installation will render the warranty null and void. Ensure the voltage marked on the power supply unit matches
your mains power supply.
This device is designed for use indoors. Observe the permissible ambient temperatures for use The device meets the requirements for electromagnetic
compatibility. Do not exceed the maximum values specified in the applicable standards.
If you have any problem, please contact your local CHARDER MEDICAL service partner.
- 3 -
ENVIRONMENTAL
All batteries contain toxic compounds; disposal of batteries
should be delegated to a competent organisation, complying with the deposit of Poisonous Waste Regulation 1972.
Please do not incinerate batteries. The optimum operating temperature for the scale is 5 to +35
; although it will operate at higher and lower temperatures the scales battery life will be adversely effected.
CLEANING
We would recommend using alcohol based wipes or similar
when cleaning the scales.
Please do not use large amounts of water when cleaning the
scales as this will cause damage to the scales electronics, you should also refrain from using corrosive liquids or high pressure washers.
Always disconnect the scales from the mains power supply
before cleaning.
MAINTENANCE
The scale does not require any routine maintenance. However, we recommend checking the scale’s accuracy at regular intervals. The regularity of these checks is dependent on the level of use and the state of the scale. If any inaccuracies occur, please contact your local dealer or CHARDER MEDICAL service partner.
- 32 -
INSTRUCTION FOR REPLACING BATTERIES
1. Removing the battery cover. 2. Take the battery housing out.
3. Replacing new batteries. 4. Batteries are well installed.
5. Installing the battery housing. 6. Reinstalling the battery cover.
- 31 -
CAUTION:
Always connect the AC adaptor with the indicator before
connecting to the mains power supply.
Please disconnect the adaptor from main power supply before
taking out the AC adaptor pin from indicator.
INSTRUCTION FOR CHARGING AND CONNECTING
If
prompt displays on the LCD, please charge the
scale with MS 4610 & 4600 exclusive adaptor or replace the batteries.
Locate adaptor plug-in at the back side of indicator.
- 4 -
WEIGHING OPERATION
Before reading detailed instructions on how to use all the weighing functions that are built into your scale, please read the following important guidelines: Always be sure that the display shows `Zero` before use, if it does not then please press the ZERO key. The device is designed to detect when a stable weight is achieved, the indicator will `bleep` twice to indicate a stable weight value, your reading should be taken at this point.
WARRANTY-LIABILITY
If a fault or defect is present on receipt of the unit which is within CHARDER MEDICAL’s scope of responsibility, CHARDER shall have the right to either repair the fault or supply a replacement unit. Replaced parts shall be the property of CHARDER. Should the fault repairs or replacement delivery not be successful, the statutory provisions shall be valid. The period of warranty shall be two years, beginning on the date of purchase. Please retain your receipt as proof of purchase. Should your scale require servicing, please contact your dealer or CHARDER MEDICAL Customer Service. No responsibility shall be accepted for damage caused through any of the following reasons: Unsuitable or improper storage or use, incorrect installation or commissioning by the owner or third parties, natural wear, changes or modifications, incorrect or negligent handling , overuse, chemical, electrochemical or electrical interference or humidity, unless this is attributable to negligence on the part of CHARDER MEDICAL.
- 5 -
If operating, climatic or any other influences lead to a major change in conditions or material quality, the treaty for perfect unit functioning shall be rendered null and void. If CHARDER provides and individual warranty, this means that the unit supplied will be free of faults for the length of the warranty period.
DISPOSING OF THE SCALE
This product is not to be treated as regular household waste, but
should be handed in to an electrical/electronic equipment
recycling centre. You can obtain further details from your local council, your municipal waste disposal company or the firm which you purchased the product.
- 30 -
2. New Connection Description
Give new connection a name then click OK.
3. Select Your COM Port Click Connect to select your COM port. Usually there’s only one option for select. Then click OK.
4. Port Settings Click Bits per second to set up rate at 9600, Data bits at 8, Parity at None, Stop bits at 1 and Flow control at Hardware. Then click OK to complete your setting.
5. Output Data When the patient has been weighed and BMI calculated, simply press the PRINT key to output data from scale to PC or an Optional Printer.
Parameters of RS232 interface Set parameters of the scale interface on the connected device. It is not possible to change the scale parameters.
Baud rate: 9600 bps Parity check: None Data length: 8 bits Stop bit: 1 bit Handshake: RTS/CTS Data code: ASCII.
- 29 -
RS232 Pin out
Connecting with PC-
MS 4610 and MS 4600 both can be
connected to PC to transfer the weighing results.
1. Start Hyper Terminal Start Hyper Terminal program from clicking Start Menu Programs Accessories Communication Hyper Terminal.
PIN 2--TXD
PIN 3--RXD
PIN 5--GND
PIN 2--TXD
PIN 3--RXD
PIN 5--GND
- 6 -
EXPLANATION OF THE GRAPHIC SYMBOLS
SN-T13000001
Designation of the serial number of every device, applied at the device.
(Number as an example)
“Please note the accompanying documents“ or “Observe operating instructions”
Charder Electronic Co., Ltd.
No.103, Guozhong Rd., Dali Dist.,
Taichung City 412, Taiwan (R.O.C.)
Identification of manufacturer of medical product including address
“Electro-medical appliance“ with attachment for type B
- 7 -
Dispose of old appliances separately from your household waste!l! Instead, take them to communal collection points.
Carefully read t
his operation manual
before setup and commissioning, even if you are already familiar with Charder scales.
Transport and storage temperature limit indicating the upper and the lower limit (Transport and storage temperature on packaging)
+60°C
-20°C
- 28 -
Note: To confirm the settings, please press HOLD when
displays on the display.
PRINT FUNCTION
The Weighing, BMI and Height results can be printed-out for records using RS232 interface cable (included in accessory kit), which is connected with the round plug at the back terminal. (MS 4600 cant print out the results directly through printer.) After weighing and calculating BMI simply press PRINT key to print out the results. The format presented below is the standard format of results print-out and cannot be changed.
- 27 -
Body Mass Index Categories Classification of weight for adults over 18 years on the basis of Body Mass Index according to WHO, 2000 EK IV and WHO 2004 (WHO ­World Health Organization).
MS4610 & 4600: SET-UP
MS 4610: Switch ON the scale and long press [ZERO] key for 3 seconds. MS 4600: Switch ON the scale and long press [UNIT] key for 3 seconds.
First “SETUP” and then “A.OFF” will display successively.
AUTO-OFF TIME SETUP This enables operator to select the auto turn OFF time of the device.
BUZZER ON/OFF SETUP This enables operator to select beep sound ON/OFF.
Auto off time: 120 sec/180 sec/240 sec/300 sec/off Buzzer: On/Off
- 8 -
EMC guidance and manufacturer's declaration
Guidance and manufacturer’s declaration-electromagnetic emissions
The MEDICAL SCALE MS4610 is intended for use in the electromagnetic environment specified below. The customer or the user of the MEDICAL SCALE MS4610 should assure that it is used in such an environment.
Emission test Compliance
Electromagnetic environment-guidance
RF emissions CISPR 11
Group 1
The MEDICAL SCALE MS4610 uses RF energy only for its internal function. Therefore, its RF emissions are very low and are not likely to cause any interference in nearby electronic equipment.
RF emissions CISPR 11
Class B
Harmonic emissions IEC 61000-3-2
Class A
Voltage fluctuations /flicker emissions IEC 61000-3-3
Compliance
The MEDICAL SCALE MS4610 is suitable for use in all establishments, including domestic establishments and those directly connected to the public low-voltage power supply network that supplies buildings used for domestic purposes.
- 9 -
Guidance and manufacturer’s declaration-electromagnetic immunity
The MEDICAL SCALE MS4610 is intended for use in the electromagnetic environment specified below. The customer or the user of the MEDICAL SCALE MS4610 should assure that it is used in such an environment.
Immunity test
IEC 60601 test
level
Compliance
level
Electromagnetic
environment-guidance
Electrostatic discharge(ESD) IEC 61000-4-2
± 6 kV contact ± 8 kV air
± 6 kV contact ± 8 kV air
Floors should be wood, concrete or ceramic tile. If floors are covered with synthetic material, the relative humidity should be at least 30%
Electrical fast transient/burst IEC 61000-4-4
± 2kV for power supply lines + 1kV for input/output lines
± 2kV for power supply lines Not applicable
Mains power quality should be that of a typical commercial or hospital environment.
Surge IEC 61000-4-5
± 1kV line(s) to line(s) ± 2kV line(s) to earth
± 1kV differential mode Not applicable
Mains power quality should be that of a typical commercial or hospital environment.
Voltage Dips, short interruptions and voltage variations on power supply input lines IEC 61000-4-11
<5% UT(>95% dip in UT) for 0,5 cycle 40% UT(60% dip in UT) for 5 cycles 70% UT(30% dip in UT) for 25 cycles <5% UT(>95% dip in UT) for 5 s
<5% UT(>95% dip in UT) for 0,5 cycle 40% UT(60% dip in UT) for 5 cycles 70% UT(30% dip in UT) for 25 cycles <5% UT(>95% dip in UT) for 5 s
Mains power quality should be that of a typical commercial or hospital environment. If the user of the MEDICAL SCALE MS4610 requires continued operation during power mains interruptions, it is recommended that the MEDICAL SCALE MS4610 be powered from an uninterruptible power supply or a battery.
- 26 -
2. MS 4600
Turn on the scale using key. Proceed to weigh as normal.
After the weight is stable and stable sign displays on the
screen long press key for 3 seconds.
Display will change to display.
Enter the height of the person using and
key- (For example: To enter 186cm, use
key to change the number and Use key to move to next digit).
Press key to confirm the height.
The B.M.I. will display
Press again to return to normal mode.
- 25 -
USING BMI FEATURE
For BMI calculation, height is needed, therefore it is recommended to measure the height of subject before starting weighing procedure and the height must be in centimeters.
1. MS 4610
Turn ON the scale using key. Proceed to weigh as normal.
After the weight is stable and stable sign displays on the
screen press key.
Display will change to display. Key-in the height of the person using numeric keys (0~9)
(Example: 186cm, the height should be in
centimeters).
Press , the Display will show the B.M.I. of the
person.
Press again to return to normal mode.
- 10 -
Power frequency(50/60 Hz) magnetic field IEC 61000-4-8
3 A/m 3 A/m
The MEDICAL SCALE MS4610 power frequency magnetic fields should be at levels characteristic of a typical location in a typical commercial or hospital environment.
NOTE UT is the a.c. mains voltage prior to application of the test level.
Guidance and manufacturer’s declaration-electromagnetic immunity
The MEDICAL SCALE MS4610 is intended for use in the electromagnetic environment specified below. The customer or the user of the MEDICAL SCALE MS4610 should assure that is used in such and environment.
Immunity test
IEC 60601 test level
Compliance level
Electromagnetic environment-guidance
Conducted RF IEC 61000-4-6
3 Vrms 150 KHz to 80 MHz
3 Vrms
Portable and mobile RF communications equipment should be used no closer to any part of the
MEDICAL SCALE
MS4610 including cables, than the recommended separation distance calculated from the equation applicable to the frequency of the transmitter.
Recommended separation distance:
d = 1,2 P d = 1,2 P 80MHz to 800 MHz d = 2,3 P 800MHz to 2,5 GHz
Where P is the maximum output power rating of the transmitter in watts (W) according to the transmitter manufacturer and d is the recommended separation distance in metres (m).
- 11 -
Radiated RF IEC 61000-4-3
3 V/m 80MHz to 2,5 GHz
3 V/m
Field strengths from fixed RF transmitters, as determined by an electromagnetic site surveya, should be less than the compliance level in each frequency range
b
.
Interference may occur in the vicinity of equipment marked with the following symbol:
NOTE1 At 80 MHz and 800 MHz, the higher frequency range applies. NOTE2 These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and reflection from structures, objects and people. a Field strengths from fixed transmitters, such as base stations for radio
(cellular/cordless) telephones and land mobile radios, amateur radio, AM and FM radio broadcast and TV broadcast cannot be predicted theoretically with accuracy. To assess the electromagnetic environment due to fixed RF transmitters, an electromagnetic site survey should be considered. If the measured field strength in the location in which the MEDICAL SCALE MS4610 is used exceeds the applicable RF compliance level above, the MEDICAL SCALE MS4610 should be observed to verify normal operation. If abnormal performance is observed, additional measures my be necessary, such as re-orienting or relocating the MEDICAL SCALE MS4610.
b Over the frequency range 150 kHz to 80 MHz, field strengths should be les than
3 V/m.
- 24 -
The instrument will make flash and beep sound and will display the saved Pre-Tare Weight.
C. RECALL PRE-TARE VALUE
DESCRIPTION EXAMPLE
Long press PRE-TARE key for 3 seconds; the display will show the blinking m sign.
Press numeral key 1 ~ 5 to choose pre-tare value
Press ENTER key to confirm the pre-tare weight; the instrument will automatically perform tare function.
Press PRE-TARE key to return to Normal Mode.
- 23 -
B. Enter Weight Using 0~9 Keys:
DESCRIPTION EXAMPLE
Press PRE-TARE key, and the extreme left digit will blink.
Enter PRE-TARE weight using 0~9 keys. For example: 10kg
Press ENTER key to confirm the pre-tare weight; the display will show the minus sign on left of the pre-tare weight value.
Press M1-5 key; the blinking m sign will appear on the display.
Press numeral key 1 ~ 5 to assign the position to pre-tare weight.
- 12 -
Recommended separation distance between portable and mobile RF
communications equipment and the MEDICAL SCALE
The MEDICAL SCALE MS4610 is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled. The customer or the user of the MEDICAL SCALE MS4610 can help prevent electromagnetic interference by maintaining a minimum distance between portable and mobile RF communications equipment (transmitters) and the MEDICAL SCALE MS4610 as recommended below, according to the maximum output power of the communications equipment.
Separation distance according to frequency of transmitter m
Rated maximum output
power of transmitter
W
150 kHz to 80 MHz
d =1,2P
80 MHz to 800 MHz
d =1,2P
800 MHz to 2,5 GHz
d =2,3P
0,01 0,12 0,12 0,23
0,1 0,38 0,38 0,73
1 1,2 1,2 2,3
10 3,8 3,8 7,3
100 12 12 23
For transmitters rated at a maximum output power not listed above, the recommended separation distance d in metres (m) can be estimated using the equation applicable to the frequency of the transmitter, where p is the maximum output power rating of the transmitter in watts (W) according to the transmitter manufacturer.
NOTE1 At 80 MHz and 800 MHz, the separation distance for the higher frequency range applies. NOTE2 These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and reflection from structures, objects and people.
- 13 -
SPECIFICATION
Model
MS4610
(APPROVAL)
MS 4600
(Non-Approval)
Capacity
300kg x
0.1kg
200kg x
0.05kg<150kg>0.1kg
660lb x 0.2lb
300kg x
0.1kg
Weight Unit
kg lb / kg
LCD Display
1.0 inch LCD display with 5 and 1/2 digits
Dimension
Platform size: 340 x 450 mm
20 keys version
ON/OFF, PRINT, BMI,
HOLD,PRE-TARE,TARE,
CLEAR, ENTER, 0~9,
M1-5, (zero)
Key
Functions
4 keys version
ON/OFF , (zero)
HOLD/BMI , TARE
4 keys version
ON/OFF, UNIT,
HOLD/BMI, TARE
Power
Supply
6-AAA size
batteries
AC-Adaptor 12~
15V
6-AAA size
batteries
AC-Adaptor
12~15V
Operation
Temperature
5/ 35
- 22 -
MS 4610- STORING AND RE-CALLING PRE-TARE WEIGHT
MS 4610 can store 5 sets of pre-tare values, and there are two methods to store pre-tare value – Using Dead Weight or Enter
weight using 0~9 keys:
A. Using Dead Weight:
DESCRIPTION EXAMPLE
Press M1-5 key after loading the weight; the display will show blinking m sign.
Press numeral key 1 ~ 5 to assign the position to pre-tare weight. For Example- Press 1 to
assign position-1 to preset tare weight.
The display will blink and make beep sound.
NOTE: You can
NOTE: You can NOTE: You can
NOTE: You can assign any other position (f
assign any other position (fassign any other position (f
assign any other position (from 1~5)
rom 1~5)rom 1~5)
rom 1~5) to pre
to pre to pre
to pre----tare
tare tare
tare weight
weightweight
weight....
- 21 -
USING TARE FUNCTION
Tare allows the user to zero the instrument to deduct the excess weight of contained objects/person from the reading of the instrument, thus giving the true weight of the object/ person being tested.
Place the container object for tare onto the tread platform. Press [TARE] key after the weight stabilizes and stable sign
displays.
Place the object/person to be weighed (without removing the
tare object) onto the platform for correct weighing results to be displayed.
To delete the saved tare value, remove the tare object from the tread platform and press [TARE] key.
- 14 -
MEDICAL SCALE MODELS APPROVAL LIST
The Medical Scales MS4610 listed below are the certified models under the Council Directive
2007/47/EC
for standard of safety, health protection and accurate metrology characteristics of medical scales:
PRODUCT
DESCRIPTION
PRODUCT MODEL NO. CLASS
Medical Scale MBF4610, MBF6010, MS21Neo, MS2320,
MS2501, MS3800, MS4610, MS4940, MS5410, MS5710, MS3700-1, MS4900, MS5810, MS5811, MS2350, MS2504, MS3830, MS3910, MS4640, MS4910, MS5440, MS5730, MS6001, MS5900, MS4200, MS4202L, MS2400, MS3500, MS4400, MHS2500, MHS2600, MHS2510, MHS2610, MS21neoV, MS4610, MS6111, MS6110, MS4201
Im
Height Measurement
HM-80P , HM-80M , HM-200P , HM-200PW , HM101M, HM110M, HM201M, HM230M, HM202P
Im
- 15 -
PANEL
MS 4610
20 key version
4 key version
MS 4600 (non-approval version)
- 20 -
Switch on the scale using [ON/OFF] key. The diagnostic
self-checks will be performed and ready for weighing function to begin with “0.0 kg” weighing value displays on the screen.
Place object/ person onto the center of the scale platform. Press the [HOLD] key, the triangle signal will prompt on the LCD
screen, indicating the scale is calculating the average weight value and the weight result will be displayed on the LCD screen .
Remove the object/ person from the scale platform. The weight
value will remain on the display.
Press the [HOLD] key again to disable HOLD function and back
to normal weighing mode.
HOLD key function can be enabled before or after putting the
weight onto the scale platform. But in case of highly unstable and weight is moving away from on the platform before the HOLD function stabilized, it is recommended to press HOLD key before the person moves on the tread platform.
(1)
- 19 -
USING SCALE
WEIGHING
Switch on the scale by press the key. The diagnostic scale
will start self-check and the software version will be displayed.
The weighing value “0,00 kg” is displayed on the screen, now the
scale is ready to perform weighing functions.
Note: If “0,00 kg” is not displayed on the screen, press key to zero the scale, can be used at any time to zero the scale.
Place the person onto the middle of the scale platform. Wait until
the scale is stabilized and stable sign (ο) will show on the screen
Note:
If a person is heavier than the maximum scale capacity, the display will prompt the “Err” message (= overload warning message).
USING HOLD FUNCTION
MS 4610 & 4600 are provided with the integrated ‘hold’ function (Weighing calculation based on average value). It enables people to be weighed accurately even when they are not able to stand still on the scale platform. When under normal weighing mode, press HOLD key, the weighing value will remain on the LCD screen after the weight is removed from the scale so the weight reading can easily be preserved for other recording purposes.
Note:
Weighing calculations of average value will be incorrect when the weight is constantly moving away and highly unstable on the platform before the stable signal prompt for the stabilized status.
- 16 -
KEY FUNCTION
MS 4610
Key Description
ON/OFF Turn ON/OFF the scale 4keys / 20keys
PRINT Data transmission via PC (Weight , BMI , Height)
BMI Determine Body Mass Index
HOLD
To hold weighing result on the display / determine stable weighing value
To reset the display to 0.0kg display / Zero the scale (±2% of full capacity) 4keys / 20keys
M1-5
To store 5 pre-tare values. refer to page 14
PRE-TARE Deducting weight before measuring.
TARE
Tare weight during weighing process
.
4keys / 20keys
CLEAR To clear the wrong entry while entering digits. ENTER
To confirm the performing functions.
0-9
Entering digits
HOLD/BMI
To hold weighing result on the display / determine stable weighing value , to determine Body Mass Index only on 4 keys version
- 17 -
MS 4600
Key
Description
4 keys version
ON/OFF
Turn ON/OFF the scale
UNIT
To select the weighing unit. (kg/lb) To hold weighing result on the display / determine stable weighing value
HOLD/BMI
Long press for 3 seconds, to determine ‘Body Mass Index’
TARE
Tare weight during weighing process.
- 18 -
LCD DISPLAY SYMBOLS
Definitions
Stable symbol: To indicate that the weight is stable.. Minor weight: Weight under zero. Zero symbol: Weight is at zero point. Low battery: Battery need to charge or replaced
PRE-TARE Indication
kg
BMI Indication
NET WEIGHT I
ndication
WEIGHT Indication
Hold Indication
Stable symbol
Minor weight
Zero symbol
Low Battery