Charbroil 07101366 Service Manual

OIL-LESS TURKEY FRYER Product Manual Model 07101366
FOR OUTDOOR USE ONLY
CAUTION:
Read and follow all safety statements, assembly instructions, and use and care directions before attempting to assemble and cook.
INSTALLER/ASSEMBLER:
Leave this manual with consumer.
CONSUMER:
Keep this manual for future reference.
If you have questions or need assistance during assembly, please call .
To insure your satisfaction and for follow-up service, register your Oil-less Turkey Fryer online at
www.grillregistration.com
WARNING:
Failure to follow all manufacturer’s instructions could result in serious personal injury and/or property damage.
CAUTION:
Some parts may contain sharp edges – especially as noted in the manual! Wear protective gloves if necessary.
1-800-241-7548
07101366 • 42804236 • 11-20-07
DANGER
If you smell gas:
1. Shut off gas to the appliance.
2. Extinguish any open flame.
3. Open lid.
4. If odor continues, keep away from the appliance and immediately call your fire department.
Failure to follow these instructions could result in fire or explosion, which could cause property damage, personal injury or death.
DANGER
1. Never operate this appliance unattended.
2. Never operate this appliance within 10ft (3m) of
any structure, combustible material or other gas
cylinder.
3. Never operate this appliance within 25 ft (7.5 m) of any flammable liquid.
4. If a fire should occur, keep away from the
appliance and immediately call your fire
department.
Installation Safety Precautions
Use Oil-Less Turkey Fryer, as purchased, only with LP
(propane) gas and the regulator/valve assembly supplied.
Oil-Less Turkey Fryer installation must conform with local codes, or in their absence of local codes, with either the
National Fuel Gas Code, ANSI Z223.1/ 4, Natural Gas and Propane Installation Code, CSA B149.1, and Propane Storage and Handling, CSA B149.2, Canadian Electrical Code, CSA C22.1 or the Standard for Recreational Vehicles, ANSI
A 119.2/NFPA 1192, and CSA Z240 RV Series, Recreational Vehicle Code, as applicable.
Oil-Less Turkey Fryer is not for use in or on recreational
vehicles and/or boats.
• This Oil-Less Turkey Fryer is safety certified for use in the United States and/or Canada only. Do not modify for use in any other location. Modification will result in a safety hazard.
Safety Symbols
The symbols and boxes shown below explain what each heading means. Read and follow all of the messages found throughout the manual.
NFPA 5
DANGER
DANGER: Indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury.
WARNING
Failure to follow these instructions could result in fire, explosion or burn hazard, which could cause property damage, personal injury or death.
WARNING
2 • 07101366
WARNING: Indicates an potentially hazardous situation which, if not avoided, could result in death or serious injury.
CAUTION
CAUTION: Indicates a potentially hazardous situation or unsafe practice which, if not avoided, may result in minor or moderate injury.
CAUTION
For residential use only. Do not use for commercial cooking.
TABLE OF CONTENTS
For Your Safety ......................................2
Grill Service Center...................................2
Installation Safety Precautions ..........................2
Safety Symbols......................................2
Product Record Information ............................3
Use and Care ....................................4-10
Parts List/ Parts Diagram .............................11
Assembly .......................................12-14
Troubleshooting..................................15-16
Limited Warranty....................................17
Registration Card ...................................19
Call Grill Service Center for Help and Parts
• If you need assistance with your product or warranty parts call 1-800-241-7548. Hours of Service Center Operation are 8:00 A.M. To 6:00 P.M. EST Monday - Friday.
To insure your satisfaction
and for follow-up service,
register your
Oil-Less Turkey Fryer
online at:
www.grillregistration.com
WARNING
Do not attempt to repair or alter the hose/valve/regulator for any “assumed” defect. Any modification to this assembly will void your warranty and create the risk of a gas leak and fire. Use only authorized replacement parts supplied by manufacturer.
• To order non-warranty replacement parts or accessories please visit us on the web at www.charbroil.com or call
1-800-241-7548 and one of our friendly and knowledgeable agents will be glad to assist you.
IMPORTANT: Fill out the product record information below.
Model Number
Serial Number
See rating label on grill for serial number.
Date Purchased
07101366
• 3
USE AND CARE
DANGER
• NEVER store a spare LP cylinder under or near the appliance or in an enclosed area.
• Never fill a cylinder beyond 80% full.
• An over filled or improperly stored cylinder is a hazard due to possible gas release from the safety relief valve. This could cause an intense fire with risk of property damage, serious injury or death.
• If you see, smell or hear gas escaping, immediately get away from the LP cylinder/appliance and call your fire department.
• Keep LP tank at a minimum distance of 24” (inches) away from appliance at all times.
24”
• A disconnected LP cylinder in storage or being transported must have a safety cap installed (as shown). Do not store an LP cylinder in enclosed spaces such as a carport, garage, porch, covered patio or other building. Never leave an LP cylinder inside a vehicle which may become overheated by the sun.
• Do not store an LP cylinder in an area where children play.
LP Cylinder
• The LP cylinder used with your appliance must meet the following requirements:
Use LP cylinders only with these required measurements: 12"
(30.5cm) (diameter) x 18" (45.7 cm) (tall) with 20 lb. (9 kg.) capacity maximum.
• LP cylinders must be constructed and marked in accordance with specifications for LP cylinders of the U.S. Department of Transportation (DOT) or the National Standard of Canada, CAN/CSA-339, Cylinders, Spheres and Tubes for Transportation of Dangerous Goods; and commission, as applicable. See LP cylinder collar for marking.
LP cylinder valve must have:
• Type 1 outlet compatible with
regulator or Oil-Less Turkey Fryer.
• Safety relief valve.
• UL listed Overfill Protection
Device (OPD). This OPD safety feature is identified by a unique triangular hand wheel. Use
only LP cylinders equipped with this type of valve.
• LP cylinder must be arranged for vapor withdrawal and include collar to protect LP cylinder valve. Always keep LP cylinders in upright position during use, transit or storage.
LP Cylinder Valve
Safety Cap
Retainer Strap
OPD Hand Wheel
LP Cylinder Removal, Transport and Storage
• Turn OFF control knob and LP cylinder valve. Turn coupling nut counterclockwise by hand only - do not use tools to disconnect. Install safety cap onto LP cylinder valve. Always use cap and strap supplied with valve. Failure to use safety
cap as directed may result in serious personal injury and/or property damage.
LP (Liquefied Petroleum Gas)
LP gas is nontoxic, odorless and colorless when produced. For
Your Safety, LP gas has been given an odor (similar to rotten
cabbage) so that it can be smelled.
LP gas is highly flammable and may ignite unexpectedly when
mixed with air.
4 • 07101366
LP Cylinder Filling
Use only licensed and experienced dealers.
LP dealer must purge new cylinder before filling.
Dealer should NEVER fill LP cylinder more than 80% of LP
cylinder volume. Volume of propane in cylinder will vary by temperature.
A frosty regulator indicates gas overfill. Immediately close LP cylinder valve and call local LP gas dealer for assistance.
• Do not release liquid propane (LP) gas into the atmosphere. This is a hazardous practice.
• To remove gas from LP cylinder, contact an LP dealer or call a local fire department for assistance. Check the telephone directory under “Gas Companies” for nearest certified LP dealers.
LP Cylinder Exchange
Connecting Regulator to the LP Cylinder
• Many retailers that sell offer you the
Oil-Less Turkey Fryer's option of replacing your empty LP cylinder through an exchange service. Use only those reputable exchange companies that inspect, precision fill, test and certify their cylinders. Exchange your cylinder only for an OPD safety
feature-equipped cylinder as described in the "LP Cylinder" section of this manual.
Always keep new and exchanged LP cylinders in upright
position during use, transit or storage.
Leak test new and exchanged LP cylinders BEFORE
connecting to grill.
LP Cylinder Leak Test
For your safety
Leak test must be repeated each time LP cylinder is exchanged
or refilled.
Do not smoke during leak test.
Do not use an open flame to check for gas leaks.
Appliance must be leak tested outdoors in a well-ventilated
area, away from ignition sources such as gas fired or electrical appliances. During leak test, keep appliance away from open flames or sparks.
1. LP cylinder must be properly secured onto . (Refer to
appliance
assembly section.)
2. Turn all control knobs to the OFF position.
3. Turn LP cylinder OFF by turning hand-wheel clockwise to a full stop.
4. Remove the protective cap from LP cylinder valve. Always use
cap and strap supplied with valve.
c
k
w
o
i
l
s
Safety Relief Valve
C
f
f
O
e
OPD Hand Wheel
Type 1 outlet with thread on outside
Strap and Cap
• Use a clean paintbrush and a 50/50 mild soap and water solution.
Brush soapy solution onto areas indicated by arrows
in figure below.
• Do not use household cleaning agents. Damage to gas train components can result.
WARNING
Do not use a POL transport plug (plastic part with external threads)! It will defeat the safety feature of the valve.
5. Hold regulator and insert nipple into LP
cylinder valve. Hand-tighten the coupling nut, holding regulator in a straight line with LP cylinder valve so as not to cross-thread the connection.
Nipple has to be centered into the LP cylinder valve.
If “growing” bubbles appear do not use or move the LP cylinder. Contact an LP gas supplier or your fire department!
07101366 • 5
tS raight
Leak Testing Valves, Hose and Regulator
1. Turn control knob to OFF.
2. Be sure regulator is tightly connected to LP cylinder.
3. Completely open LP cylinder valve by turning hand wheel
counterclockwise. If you hear a rushing sound, turn gas off immediately. There is a major leak at the connection. Correct
before proceeding.
Hold coupling nut and regulator as shown for proper connection to LP cylinder valve.
6. Turn the coupling nut clockwise and tighten to a full stop. The
regulator will seal on the back-check feature in the LP cylinder valve, resulting in some resistance. An additional one-half to
three-quarters turn is required to complete the connection. Tighten by hand only – do not use tools.
NOTE:
If you cannot complete the connection, disconnect regulator and repeat steps 5 and 6. If you are still unable to complete the connection, do not use this regulator!
DANGER
• Do not insert any tool or foreign object into the valve outlet or safety relief valve. You may damage the valve and cause a leak. Leaking propane may result in explosion, fire, severe personal injury, or death.
4. Brush soapy solution onto areas circled below.
WARNING
• This appliance is not intended to be installed in or on a boat.
This appliance
is not intended to be installed in or on an RV.
• Never attempt to attach this to the self­contained LP gas system of a camper trailer or motor home.
• Do not use until leak-tested.
appliance
• If a leak is detected at any time, STOP and call the fire department.
• If you cannot stop a gas leak, immediately close LP cylinder valve and call LP gas supplier or your fire department!
6 • 07101366
appliance
5. If “growing” bubbles appear, there is a leak. Close LP cylinder valve immediately and retighten connections. If leaks cannot be stopped do not try to repair. Call for replacement parts. Order new parts by giving the serial, model number and name and part number of items needed (see parts list) to the Grill Service Center at 1-800-241-7548.
6. Always close LP cylinder valve after performing leak test by turning hand wheel clockwise.
Loading...
+ 14 hidden pages