Channel Vision P-0920 User Manual

CO Input
# or
CO Input
*
No CO
Strike T
3/5 rng
3
1
2
ime
P-0920
Unlock
Door
Strike Active
Chime
TELEPHONE ENTR
Intercom
Ring
Intercom
Active
N
N
A
C H
N
O
SI
I
V
CONTROLLER
Y
elephones
T
EL
TM
Power
12V
Phones
AC
P-0920
Telephone Entry Controller
• Intelligent Entertainment • Infrastructure • Security Solutions
The P-0920 is a telephone entry controller that works with Channel Vision’s IU and DP series door stations to create an elegant door intercom system. When the door station button is pressed, the phones will ring. Simply answer the phone and you will be able to speak to the person at the door.
Features:
!
Distinctive telephone ring
!
LED status indicators
!
RJ-45 connections for input and output
Phone line in from the service provider CO (Central Office).
Dry contact that closes when the doorbell button is pressed.
Connect a standard push-button. When the button is pressed the door strike relay will be activated. Note: TE110DS is sold separately.
Connect a compatible door intercom station.
Orange Terminal - Connect 12VAC power supply
Output to telephones.
WARNING!
Power should only be applied to the orange power terminal. If power is applied to other inputs, the resulting damage is not covered under warranty.
CO Input
Chime
1
2
3
#
Strike
or
*
Time
3/5 rng
No CO
Door
Strike Active
Model
P-0920
PRO
PowerIntercomUnlock
Ring
Intercom
Active
C H AN NE L
V I SI ON
TM
Phones
12VAC
Ring LED Flashes when phones ring.
Intercom Active LED Lights when door intercom station is in use.
TELEPHONE ENTRY CONTROLLER
Strike Active LED Lights when the door strike relay has been
CO Input
Telephones
activated.
Configuration switches (see basic setup).
RJ-45 input for CO lines and output to Telephones. These allow pass-through of 4 telephone lines. Note: only line 1 is affected by the telephone entry controller. Important: The RJ-45 input and output cannot be used if
2
there is a CO line connected to the wire terminal input.
Compatibility
The P-0920 must be used together with a compatible door intercom station. Channel Vision offers a variety of compatible units such as the popular IU-series and DP-series intercom stations. Example: model DP­0212 is compatible.
Important Exceptions:
Channel Vision offers some IU-series and DP-series intercom stations that are only compatible with Panasonic KSU phone systems. These model numbers, which end with the letter “P”, will NOT WORK. Example: model DP-0212P is NOT COMPATIBLE.
How it Works
The P-0920 is installed in-line between your telephone service provider and your telephone distribution system. A compatible door intercom station is installed and connected to the P-0920. When the door intercom’s button is pressed, the phones in the house will ring. If the phone is answered within 20 seconds you will be automatically connected to door intercom station. If you wish to contact the door intercom station after 20 seconds has passed, pick up the phone and dial ** (or ## depending your configuration).
If you are using the optional TE110DS door strike relay module, it can be activated by dialing the appropriate touch-tone code (see the user’s guide section) or by pressing a button that is connected to the “Unlock Door” terminals. You can use the “Unlock Door” terminals If you would like to open an access gate from outside of the house without using a telephone. Simply wire a standard push button to these terminals that will provide a momentary short when the button is pressed.
Use the “Chime” terminals if you would like to use a traditional doorbell chime in addition to ringing the telephones when the door intercom button is pressed.
Wiring Options
For convenience, there are two different ways to connect the active phone line input and telephone output. Option 1: connect the active phone using a single pair of wires to the wire terminals labeled “CO Input”. Then connect a single pair of wires to the wire terminals labeled “Telephone” and connect the other end of those wires to your telephone distribution wiring system. Option 2: use the RJ-45 jacks to connect the “CO Input” and “Telephone” output. This option simplifies wiring because CAT5 jumper cables can be used to interconnect the P-0920 with other Channel Vision telephone modules.
3
Basic Application
For proper operation, the system must be connected as shown. If telephones are connected directly to the telephone service provider, those telephones will not be able to utilize the entry system.
This system uses a 12 Volt AC power supply. Make sure you use the power supply provided with the unit (or an equivalent replacement). If a DC power supply is used, the system may appear to work normally, but it will not be able to ring the phones.
The configuration switches affect many of the P-0920’s features. Use the guide below to configure the P-0920 for your application.
From Telephone Service Provider
CO Input
1
2
#
Strike
or
*
Time
3/5 rng
No CO
CO Input
On
Off
#
Strike
or
*
Time
3/5 rng
No CO
4
terminals marked
3
Chime
P-0920
Model
Door
Strike Active
PowerIntercomUnlock
Ring
Intercom
Active
CH AN NEL
TM
VI SI ON
PRO
12VAC
Phones
12VAC 500mA
(IU-xxxx or DP-xxxx)
TELEPHONE ENTRY CONTROLLER
Telephones
House Telephones
Key * - #: Sets the activation key for the P-0920. On = #, Off = *
No CO-on: Enables “No CO” mode, allowing the unit to work if there is no
active telephone line.
Rings 3-5: Sets the ring pattern. On = 5 rings, Off = 3 rings.
1
2
3
Strike Time: Sets the length of time the TE110DS will be activated. See the
chart below.
3
Off
On
Off
On
Off Off On On
3
21
Off
3 Seconds
Off
5 Seconds
Off
8 Seconds
Off
15 Seconds
Off On Off On
21
Off Off On On
On On On On
20 Seconds
40 Seconds 120 Seconds 240 Seconds
Connect to the
“TO SYS”
Door Plate
Loading...