MULTI-ROOM AUDIO VIDEO KIT
Model #MAV-3
STEP-BY-STEP INSTALLATION INSTRUCTIONS
Step 1: Connect the low-pass filter (model #3102-78) as far upstream as possible to the incoming cable or antenna line. This
will “clean up” the frequency range above channel 80 (antenna channel 29) to eliminate the potential for broadcast
interference with your new modulated channel. Optional filters (3102-60 and 3102-105) block channels 60 (antenna
channel 14) or 105 (antenna channel 49) and above. Please note: Channels 95-99 will not be affected by our filter.
Step 2: Using a coaxial cable connect the output from the low-pass filter into the RF Input of the RF amplifier (model
C-0310). This will create a balance in signal strengths between the cable/antenna feed and the modulator output
before combining the two together. Also an amplifier prevents backfeed into the cable system.
Step 3: Connect a coax cable (not included) from the C-0310 DC12V power input to the AC Adapter and plug the AC
Adapter into a 110V AC power outlet.
Step 4: Connect a coax cable (not included) from the output of the C-0310 into one of the inputs on the broadband combiner
(model #HS-2T).
Step 5: Connect each audio video source to the RF Modulator using RCA cables (not included).
Step 6: Connect a coax cable from the RF output port to the second input port of the broadband combiner (model #HS-2T).
Step 7: Plug the modulator 12VDC power transformer into a 110V AC power outlet.
Step 8: Connect a coax cable from the combiner output to the input of a broadband splitter (not included) for distribution to
multiple televisions. Channel Vision has a variety of splitters available (models HS-2, HS-3, HS-4, HS-6, HS-8 or
HS-16) for distribution to multiple televisions. Any combination of splitters may be used to match the total outputs
Modulator Setup:
Step M1: While the unit is unplugged, choose the band and channel range you want to modulate to by selecting the appropriate
Step M2: To change the modulator channel: push and hold the Select button for three seconds until the power LED on the front
Step M3: Select a channel no lower than #84 as the low-pass filter (model #3102-78) has cleaned up the frequencies above
Step M4: The modulated channels should now be available at every television connected to the system.
required.
DIP switch settings on the back panel of the modulator. The modulator is pre-set for cable TV channels. Once you
have the DIP switches in place plug the unit into a 110V AC Power Outlet.
of the unit begins to flash then press Up or Down to select a channel. Press the Select key again to lock the channel
into memory.
channel #80. Please Note: Channels 95-99 are not available.
For more information on fine tuning your modulator please consult the RF Modulator operation manual.
234 FISCHER AVENUE • COSTA MESA, CA 92626
(714) 424-6500 • (800) 840-0288 • F
www.channelvision.com • email: sales@channelvision.com
© 2001, CHANNEL VISION™
AX (714) 424-6510
REV. 1/05

MULTI-ROOM AUDIO VIDEO KIT
Model #MAV-3
SYSTEM DIAGRAM
Cable or
SAT REC.
Antenna
VCR
DVD PLAYER
5
B
AC
RF OUT
Optional Parts:
HS-2 Broadband splitter/combiner for up to 2 TVs
HS-3 Broadband splitter/combiner for up to 3 TVs
HS-4 Broadband splitter/combiner for up to 4 TVs
HS-6 Broadband splitter/combiner for up to 6 TVs
HS-8 Broadband splitter/combiner for up to 8 TVs
HS-16 Broadband splitter/combiner for up to 16 TVs
CVT-2/4PIA Amplified 4-way splitter
CVT-2/8PIA Amplified 8-way splitter
DP-3/8 Amplified RF Distribution Panel: 3 inputs 8
outputs for cable distances up to 200 feet
DP-3/12 Amplified RF Distribution Panel: 3 inputs 12
outputs for cable distances up to 300 feet
3000-3 Attenuator to decrease signal strength by 3dB
3000-6 Attenuator to decrease signal strength by 6dB
3000-10 Attenuator to decrease signal strength by 10dB
3000-20 Attenuator to decrease signal strenght by 20dB
12VDC IN
E 3200
1
3102 Filter
3
2
CVT-10PIA
C-0310
7
4
HS-2T
6
Please Note: Because distances vary by
installation, coax cable is not included.
For best performance we recommend
using at least RG6 Quad coax cable for
all RF distribution systems.
8
© 2001, CHANNEL VISION™

Channel Vision Limited Warranty
Channel Vision Technology will repair or replace any defect in material or workmanship which occur during
normal use of this product with new or rebuilt parts, free of charge in the USA, for two years from the date of
original purchase. This is a no hassle warranty with no mail in warranty card needed. This warranty does not
cover damages in shipment, failures caused by other products not supplied by Channel Vision Technology, or
failures due to accident, misuse, abuse, or alteration of the equipment. This warranty extends only to the
original purchaser. A purchase receipt, invoice, or other proof of original purchase date will be required
before warranty repairs are provided.
Mail in service can be obtained during the warranty period by calling toll free (800) 840-0288 toll free. A
Return Authorization number must be obtained in advance and be marked on the outside of the shipping
carton.
This warranty gives you specific legal rights, and you may have other rights (which vary from state to state).
If a problem with this product develops during or after the warranty period, please contact Channel Vision,
your dealer, or any factory-authorized service center.