2x8 Amplifier for Standard & Wide-Band
CATV Systems
1
0
The CVT-2/8WB and C-0333 are 8-output amplified splitters with a built-in
combiner for modulated signals. They allow IR signals to pass through the
modulator input to the TV outputs, making it a perfect match for the
E2200IR, E3200IR or E4200IR. The CVT-2/8WB is designed to mount
directly on any flat surface, while the C-0333 can snap directly into a
structured wiring enclosure.
Features:
!
8 Amplified outputs: 4.5dB Gain
!
Amplified return path from 5-42MHz
!
Compatible with Advanced Wide Bandwidth Digital CATV systems
!
Supports 1 modulator input
!
Allows IR pass through on the modulator input port
Connect modulator here
CABLE IN...Connect the antenna
or cable service feed here
TV OUTPUTS
+4.5 dB+4.5 dB
Connect TVs here
POWER IN
Connect power supply here
CABLE IN...Connect the antenna
or cable service feed here
12VDC
POWER IN
Connect power supply here
MOD In
-15.5dB
TV OUTPUTS
Connect TVs here
MOD IN
Connect modulator here
75 ohm Terminators
12VDC, 500mA
2
Basic Amplified Splitter Application
Connect the CVT-2/8WB as shown and locate it at the main distribution point
in the house. The CVT-2/8WB will supply the amplified TV signal to 8 TV
locations.
The CVT-2/8WB can be cascaded for situations that require more than 8
outputs. Each of the 8 outputs of the CVT-2/8WB can feed the input of an
additional CVT-2/8WB creating a system with 64 TV outputs.
Use a total of 9 CVT-2/8WBs to achieve 64 TV outputs.
The IR engine built into the E2200IR, E3200IR, and E4200IR can support up
to 8 TV locations with IR receivers. Note: any TV location that does not have
IR receiver needs to be DC blocked using model 3109.
The CVT-2/8WB can be integrated with the P-0321 to send modulated signals
through a system that has some TVs with digital cable boxes and some TVs
without digital cable boxes. An RF filter can be used to remove the digital
content from the TVs which do not have digital boxes. This allows modulated
channels to be inserted without interference problems. The P-0321 preserves
the digital content for the locations that do have digital boxes. Additional details
regarding the operation of the Affinity model P-0321 can be found in its
installation manual.
Operation Time
Insertion Loss
Return Loss (I/O)
IR PASS
Frequency Range
Gain
Flatness
Return Loss (I/O)
Isolation
Noise Figure@70 degrees F
Group Delay (54 to 66MHz)
Group Delay (66 to 88MHz)
Group Delay (88 to 1000MHz)
Composite Second Order Distortions
Composite Triple Beat Distortions
Cross Modulation Distortions
Second Hum Modulation
Rated Output Level @160 channels, 6MHz each
Power Consumption
Frequency Range
Flatness
Return Loss (I/O)
Isolation
Noise Figure@70 degrees F
Group Delay (5 to 10MHz / 36MHz to 42MHz)
Group Delay (10 to 36MHz)
Composite Second Order Distortions
Composite Triple Beat Distortions
Cross Modulation Distortions
Second Hum Modulation
Rated Output Level @2 channels, 6MHz each
Power Consumption
RFI Shielding
Nominal Impedance “F” Female
Supply Voltage (DC)
MODULATOR PATH
CATV FORWARD PATH
54-800MHz
800-860MHz
975-1525MHz
CATV RETURN PATH
5-40MHz
40-42MHz
GENERAL SPEC
-1.0dB
-1.5dB
Specifications subject to change without notice.
Full Time Bypass
<20dB (15dB typ.)
>14dB
Yes
54-860 / 975-1525MHz
5.0dB
4.0dB
-14dB
6.0dB
5.0dB
-17dB
+1.0dB
>14dB
>18dB
7.5dB
60ns
22ns
12ns
64dBC
74dBC
60dBC
60dBC
+23.0 dBmV
180mA
5-42MHz
0dB
-1.0dB
+1.0dB
>14dB
>20dB
20dB
55ns
36ns
53dBC
56dBC
56dBC
58dBC
+43.0 dBmV
65mA
>110dB
75 ohm
12-15VDC
7.0dB
6.0dB
-20dB
1.0dB
0dB
7
1
Channel Vision Technology will repair or replace any defect in
material or workmanship which occurs during normal use of this
product with new or rebuilt parts, free of charge in the USA, for one
year from the date of original purchase. This is a no hassle warranty
with no mail in warranty card needed. This warranty does not cover
damages in shipment, failures caused by other products not supplied
by Channel Vision Technology, or failures due to accident, misuse,
abuse, or alteration of the equipment. This warranty is extended only
to the original purchaser, and a purchase receipt, invoice, or other
proof of original purchase date will be required before warranty
repairs are provided.
Mail in service can be obtained during the warranty period by calling
(800) 840-0288 toll free. A Return Authorization number must be
obtained in advance and can be marked on the outside of the shipping
carton.
This warranty gives you specific legal rights and you may have other
rights (which vary from state to state). If a problem with this product
develops during or after the warranty period, please contact Channel
Vision Technology, your dealer or any factory-authorized service
center.
Channel Vision products are not intended for use in medical,
lifesaving, life sustaining or critical environment applications.
Channel Vision customers using or selling Channel Vision products
for use in such applications do so at their own risk and agree to fully
indemnify Channel Vision for any damages resulting from such
improper use or sale.
w ww .c ha nn el vi si on .c om
234 Fischer Avenue, Costa Mesa, California 92626 USA
(714)424-6500 (800)840-0288 (714)424-6510 fax
email: techsupport@channelvision.com
500-254 rev A1
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.