The A0301 is a universal input module for Channel Vision’s CAT5 A
udio
Systems that can accept audio from any standard L/R line-level audio
source. The attractive decorator style faceplate allows the unit to blend in
with modern light switches and outlets. It can be used to provide local
source input in any room and/or as the main system input device. The
A0301 is a great way to enable simple connection of local sources such
as TV’s, MP3 players, and computer sources into the zone.
Features:
!
Compatible with Channel Vision’s CAT5 Audio Systems
!
Senses audio to automatically override the main audio source
!
Provides 2 IR emitter outputs
!
Uses CAT5 cabling
IR Emitter Outputs... Connect IR emitters here
LED Indicator... Flashes when IR is present
Input Connectors... 110 and RJ-45 inputs for
CAT5 - use one or the other (not both)
Output Connectors... 110 and RJ-45 inputs
for CAT5 - use one or the other (not both)
IR emitters
Line level inputs
IN
IN
OUT
OUT
L/R Audio Inputs...
2
Connect standard audio sources
Required System Components
The A0301 is not a standalone device. It must be installed as part of an
audio system which requires the following components:
CAT5 Audio Hub or CAT5 Audio Matrix:
EL
CHAN N
TM
ON
I
S
I
V
IR
Emitters
PRO
Zone 3
Expansion
Output
Zone 4
Power
Status
(Required)
(Optional)
TM
SION
VI
NEL
AN
CH
Model P-2014
Zone 2
Zone 1
System
Input
Audio Distribution Module
x
1 4 CAT5
System
Signal
Priority
Local
R
Local
L
Input
P-2014
(power supply included)
Volume Control Keypad:
A0125
CHA NNE L VI SIO N
Pwr
Source
OR
Link
In
AN
CH
Model P-2044
Source 1Source 2
Zone 1
Active
Zone 2
Active
TM
NEL VISION
Source 2 IRSource 1 IR
Source 3 IR
Source 3
CHAN NEL
VISI ON
PRO
Source 4 IR
Source 4
Zone 3
Active
Zone 4
Active
Link
Out
TM
Common IR
IR Data
Power
P-2044
(power supply included)
In-Room Amplifier:Wiring Interface:
A0240A0302
Channel Vision
R
L/S
Line Out
Amp-Link
Speakers:
In-ceiling, In-wall and free-standing 8 ohm speakers are acceptable.
3
System Wiring Diagram
Using the A0301 as a local source input module
P-2014
EL
HA NN
C
TM
N
IO
S
I
Tape Monitor or
Room 2 output
Sat radio
DVD player
CD player
Receiver
I
V
L
E
CHANN
Model P-2014
System
Input
System
Signal
Priority
Local
R
Local
L
Input
(Optional) IR emitters
Channel Vision
Line Out
R
L/S
S
IO
Zone 1
TM
N
x
1 4 CA
Zone 2
T5
A0125
CH ANN EL V ISI ON
V
PRO
Zone 4
Zone 3
Audio Distribution Module
IR
Emitters
Status
(Optional)
Expansion
Output
Power
(Required)
A0301
(Rear)
IN
OUT
IN
OUT
Amp-Link
Pwr
Source
A0301
(Front)
IR emitters
Line level inputs
Connect the line level audio outputs
of a local audio source, such as a TV,
MP3 player, or computer.
4
Advanced System
Using the A0301 as the main source input module
Room 1Room 3
Channel Vision
L/S
CHAN NEL V ISI ON
R
Line Out
Amp-Link
Pwr
Source
IR emitters
Line level inputs
P-2014
A0301
IR emitters
Line level inputs
CD Player
Primary audio source
TM
N
O
I
L VIS
E
ANN
H
C
Model P-2014
System
Input
Signal
Priority
Local
L
Input
Zone 2
Zone 1
x
1 4 CAT5 Audio Distribution Module
System
Local
R
Sat radio
Secondary audio source
Emitters
Zone 3
IR
EL
N
AN
CH
M
T
N
O
I
VI S
PRO
Zone 4
In this configuration, either the satellite
radio tuner or the A0301 connected to the
System Input of the P-2014 can act as the
main system input. If audio is present from
both sources, then the Priority switch will
determine which source is heard. In this
example the switch is set to give the A0301
priority.
A0313A0301
Line Out
Amp-Link
R
(Rear)
IN
OUT
IN
CHAN NEL V ISI ON
Pwr
Source
A0125
(Rear)
OUT
Status
(Optional)
A0313 or A0301
Expansion
Output
Power
(Required)
Channel Vision
L/S
A0302
Channel Vision
R
L/S
Line Out
Amp-Link
(See A0125 manual for connection details)
A0301 and A0313 can be used as primary system inputs feeding the main
hub or as local input modules in each room to override the primary audio
source. The A0301 is a generic input module which provides a standard
L/R RCA input and the A0313 is an iPod docking station.
®
These local input modules should be installed in the CAT5 line between
the P-2014 and the A0125. Multiple input modules can be installed in one
CAT5 run. If audio is present at more than one input module the unit
closest to A0125 will take priority and be played through the speakers.
5
5
Using IR Repeating
Sat radio
DVD player
CD player
Receiver
IR emitters
Line level inputs
Main
A0301
Inputs ... IR-3002 emitters placed
over IR receiver on all sources.
Connect audio L/R on the A0301 to
the tape monitor output of the
receiver.
L
NE
N
A
CH
M
T
N
VI SIO
TM
ON
I
EL VIS
ANN
H
C
Model P-2014
Zone 1
System
Input
x
1 4 CAT5 Audio Distribution Module
System
Signal
Priority
Local
R
Local
L
Input
PRO
Zone 3
Zone 2
IR
Emitters
Expansion
Output
Zone 4
Power
Status
(Required)
(Optional)
Local
A0301
Channel Vision
L/S
Line Out
Amp-Link
CHA NN EL VI SI ON
R
Pwr
Source
1
2
4
3
5
7
Power
6
8
9
0
IR emitters
Line level inputs
Sat radio
Local audio source
IR signals detected by the A0125 will be repeated at the local
A0301 as well as the main A0301, making it easy to control either
main source components or local source devices.
6
Stripping and Connecting CAT5 Wire
CAT5 cable should be stripped with a proper stripping tool, such as Channel
Vision’s J-110 tool.
1. Place the CAT5 between the blade and the first notch of the J-110 tool.
CAT5
Blade
2. Rotate the tool only once. Multiple
turns could damage the inner wires.
3. Inspect the inner wires for damage.
If any wires are cut start over at step 1.
Check for damage
TIA-568A RJ-45 Modular Plug
Side view:
Top view:
Rotate
1 turn only
Slight
pressure
Green/White - Left channel ground
Green - Left channel
Orange/White - Right channel ground
Blue - Signal
Blue/White - Status
Orange - Right channel
Brown/White - Ground
Brown - 24vDC
Specifications: (typical @25º C)
Operating Voltage : 18VDC
Cable requirements:CAT5 or better
Operating Temperature:-10ºC to +50ºC
Specifications subject to change without notice.
Apple and iPod is are trademarks of Apple, Inc., registered in the U.S.
and other countries.
iBus is a registered trademark of Channel Vision Technology.
7
1
Channel Vision Technology will repair or replace any defect in
material or workmanship which occurs during normal use of this
product with new or rebuilt parts, free of charge in the USA, for one
year from the date of original purchase. This is a no hassle warranty
with no mail in warranty card needed. This warranty does not cover
damages in shipment, failures caused by other products not supplied
by Channel Vision Technology, or failures due to accident, misuse,
abuse, or alteration of the equipment. This warranty is extended only
to the original purchaser, and a purchase receipt, invoice, or other
proof of original purchase date will be required before warranty
repairs are provided.
Mail in service can be obtained during the warranty period by calling
(714) 424-6500. A Return Authorization number must be obtained
in advance and can be marked on the outside of the shipping carton.
This warranty gives you specific legal rights and you may have other
rights (which vary from state to state). If a problem with this product
develops during or after the warranty period, please contact Channel
Vision Technology, your dealer or any factory-authorized service
center.
Channel Vision products are not intended for use in medical,
lifesaving, life sustaining or critical environment applications.
Channel Vision customers using or selling Channel Vision products
for use in such applications do so at their own risk and agree to fully
indemnify Channel Vision for any damages resulting from such
improper use or sale.
w ww .c ha nn el vi si on .c om
234 Fischer Avenue, Costa Mesa, California 92626 USA
(714)424-6500 (800)840-0288 (714)424-6510 fax
email: techsupport@channelvision.com
500-209 revA
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.