Chaney Instrument VN1TXCA2 Users Manual

Instruction Manual
Professional Weather Center
model 02064C / 999143
CONTENTS
Unpacking Instructions ........... 2
Package Contents .................. 2
Product Registration ............... 2
Features & Benets: 5-in-1 ....... 3
Features & Benets: Display .... 4
Setup .................................... 7
5-in-1 Sensor Setup ................ 7
Display Unit Setup ................. 8
AcuRite Connect .................... 9
Backlight Settings .................. 10
Placement Guidelines ............ 11
5-in-1 Sensor Installation
Using the Weather Center .....13
Rainfall Tracking ...................14
Weather Ticker .....................15
Troubleshooting ....................16
Care & Maintenance .............19
Calibration .......................... 20
Specications ........................21
FCC Information ...................21
Customer Support ................ 22
Warranty............................. 22
........12
Questions? Contact Customer Support at
(877) 221-1252 or visit www.AcuRite.com.
SAVE THIS MANUAL FOR FUTURE REFERENCE.
Features & Benets
Congratulations on your new AcuRite product. To ensure the best possible product performance, please read this manual in its entirety
and retain it for future reference.
Unpacking Instructions
Remove the protective lm that is applied to the LCD screen prior to using this product. Locate the tab and peel off to remove.
Package Contents
1. Display unit with tabletop stand
2. 5-in-1 sensor
3. Sensor mounting bracket
4. Mounting hardware
5. Power adapter
6. USB cable
7. 4 alkaline batteries
8. Instruction Manual
IMPORTANT
PRODUCT MUST BE REGISTERED TO RECEIVE WARRANTY SERVICE
11
7
1
2
9
5
43
8
6
10
PRODUCT REGISTRATION
Register online
to receive 1 year
warranty protection
www.AcuRite.com
5-in-1 SENSOR
1. Rainfall Collector Funnel
2. Solar Cell Panel
Converts sunlight into power to run
Register a Product
2 3
internal aspirating fan. Internal Aspirating Fan
(not shown) Draws ambient air into
sensor to reduce solar radiation heating, resulting in more accurate
temperature measurement.
3. A-B-C Switch
ID code that must match display’s
A-B-C switch to ensure units
synchronize.
4. Battery Compartment
5. Temperature & Humidity Sensors
(internal)
6. Mounting Point
7. Wind Speed Anemometer
8. Wind Direction Vane
9. Mounting Bracket
10. Mounting Hardware
Includes anchors & screws.
Qty Diameter Length
5 #4 3/4” 1 #4 1/2” 1 #6 1/2”
11. Debris Filter
Pre-installed to prevent debris from entering the rain gauge.
Features & Benets
Display Unit
32
31 30 29
28
27 26
25
24
1 432 75 6
1. Previous 2 Wind Directions
2. Backlight Button
For momentary backlight and dimmer settings.
3. Current Wind Speed
4. Current Wind Direction
5. Peak Wind Speed
Highest speed from the last 60 minutes.
6. High Wind Speed Icon
Indicates peak wind speed is greater than 50 MPH (81 KPH).
7. Current Indoor Temperature
Arrow icon indicates direction temperature is trending.
8. High Indoor Humidity Icon
8
9 10
11 12
13 14
15 16
17
18
Indicates indoor humidity level is
greater than 75% RH.
9. Current Indoor Humidity
Arrow icon indicates direction
humidity is trending.
10. Humidity Level Indicator
Indicates a high, low, or ideal indoor humidity comfort level.
11. Low Indoor Humidy Icon
Indicates indoor humidity level is below 16% RH.
12. Display Low Battery Icon
13. Clock
14. Rainfall
Displays rainfall total for TODAY, this WEEK, or this MONTH.
15. Today’s Rain Indicator
Illustrates rainfall collection up to 1
inch (25 mm).
16. 12 to 24 Hour Weather Forecast
Self-Calibrating Forecasting pulls data
1920212223
from your 5-in-1 sensor to generate your personal forecast.
18. Barometric Pressure
Arrow icon indicates direction pressure is trending.
19. “ “ Button
Changes the rainfall data being displayed (#17).
20. “ ” Button For setup preferences and manually
cycling through Weather Ticker
messages.
21. “ ” Button
for setup preferences.
22. “ ” Button
For setup preferences and manually cycling through Weather Ticker
messages.
23. “ ” Button
Changes the WEATHER SELECT category (#25) being displayed.
24. Weather Ticker
Streams real-time data (see page 15).
TM
25. WEATHER SELECT
Displays high/low records and seasonal data (see page 13).
26. AUTO DIM Icon
Indicates display is in auto-dimming
brightness mode. (see page 10)
27. Date
28. Current Outdoor Humidity
Arrow icon indicates direction
humidity is trending.
29. Average Wind Speed
Taken from all wind speed readings
over the past 2 minutes.
30. 5-in-1 Sensor Signal Strength
31. Sensor Low Battery Icon
32. Current Outdoor Temperature Arrow icon indicates direction
temperature is trending.
17. Rainfall History
Displays historical rainfall totals (see
page 14).
4 5
SETUP
############
Back of Display Unit
5-in-1 Sensor Setup
1
2
3
5
4
Set the A-B-C Switch
1
Locate the A-B-C switch inside the battery compartment. Set the A-B-C switch to A, B or C. You must select
6
the same letter choices for both the sensor and the display unit in order for the units to synchronize.
7
Install or Replace Batteries
2
Batteries MUST be installed for
this product to operate. AcuRite
recommends high quality alkaline
cause alkaline batteries to function improperly. Use lithium batteries in
the 5-in-1 sensor for temperatures
below -4ºF / -20ºC.
1. Slide off the battery
compartment cover.
2. Insert 4 x AA batteries into the
battery compartment, as shown. Follow the polarity (+/-) diagram in the battery
compartment.
3. Replace the battery cover. or lithium batteries for the best product performance. Heavy duty or rechargeable batteries are not
recommended.
The 5-in-1 sensor requires lithium batteries in low temperature conditions. Cold temperatures can
3
Remove Rain Gauge Stabilizer
Locate and remove the rain gauge stabilizer (plastic tab) taped into
the bottom of the sensor. The rain
gauge will not function until this is
removed.
BACK OF DISPLAY UNIT
1. Plug-in for Power Adapter
2. Plug-in for USB Cable
3. Integrated Keyhole
for easy wall mounting.
4. MAC ADDRESS 12 digit unique ID required for
online connectivity functions.
5. Backup Battery Compartment
6. A-B-C Switch ID code that must match 5-in-1
sensor’s A-B-C switch to ensure units synchronize.
8
9
A B C
7. CLEAR RECORD / RESET Button
Press to clear data recorded since 12:00 am. Press and HOLD
A-B-C Switch
for full reset to factory defaults.
8. Power Adapter
1
Set to match
display unit
9. USB Cable for PC Connection
10. Battery Compartment Cover
(not shown)
Install Batteries
2
4 AA Batteries
6 7
Rain Gauge Stabilizer
3
Remove and discard
Loading...
+ 9 hidden pages