4.1.3 Outdoor today’s high / low Temperature Display
4.1.4 Today’s high / low temperature display icon
4.1.5 Outdoor Temperature Trend Line Display
4.1.6 C/F Slide Switch
4.1.7 ID A, B, C Slide Switch
4.1.8 The Display Icon of Reception Signal Strength -115 dB
4.2 Transmitter
4.2.1 Outdoor Temperature / Humidity
4.2.2 C/F button - Inside Search Button (This function is used for manufactory)
4.2.3 ID A, B, C Slide Switch
Model No. 00611 / 00615
Model Name
Version 4.0
Effective Date 12/6/2006
Wireless Weather Station
5. Communication Protocol
5.1 Data Format
5.1.1 Format
There are two data types – Data 1, Data 2. The duration time for each data is 610us
Data 1: The duration time of High Level is 400us,
The duration time of Low Level is 210us.
Data 2: The duration time of High Level is 210us,
The duration time of Low Level is 400us.
5.1.2 Preamble Format
The preamble is 1 byte. There are 8 bits in the preamble. It is made up of 4 high levels (610us) and 4
low levels (610us) as below figure. It is transmitted from high level.
7.1.2 When Power on or reset the LCD will full display for 3 seconds, the unit start to work.
7.1.3 The unit will detect the temperature and humidity every 30s.
7.1.4 Indoor Humidity Calculation and Display
7.1.5 Indoor Temperature Display
7.1.6 The outdoor temperature and humidity will be displayed when the signal is picked up, and the High/Low
temperature is displayed at the same time.
7.1.7 Display of high and low outdoor temperatures is to be a rolling 24-48 hour value as follows:
7.1.8 Trend lines (increasing decreasing steady)
7.1.9 RF433 Reception
When power on the receiver, the unit will turn on the RF module to looking for the RF signal, the
RF433 reception bars cycles (i.e. one bar, two bars, three bars…….one bar, two bars … etc.) This
continues until the unit receives a valid signal or for maximum 6 minutes if no signal is captured.
7.2 Transmitter (FCC ID: RNERF100XTX)
7.2.1 Key Function
7.2.1.1 A C/F button (search button) is added inside the transmitter.
7.2.1.2 A slide switch with A, B, C position is to select A, B, C channel. The factory default setting is A.
7.2.4 The unit will detect the temperature and humidity every 16s.
7.2.5 Outdoor Humidity Calculation and display in the receiver
This device complies with part 15of the FCC Rules and RSS-210 of IC rules.
Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and
(2) This device must accept any interference received, including interference that may cause undesired
operation
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.