SAVE THESE INSTRUCTIONS. This manual contains important safety precautions which should be read and
understood before operating the product. Failure to do so could result in serious injury. This manual should
remain with the product.
Specifications, descriptions and illustrations in this manual are as accurate as known at the time of publication,
but are subject to change without notice.
Assembled in USA - REV 20190214Champion Power Equipment, Inc., Santa Fe Springs, CA USA
100603 - INVERTER GENERATOR COVERTABLE OF CONTENTS
Removing Strap Mounting Assembly From
The Inverter Generator
........................... 12
2
100603 - INVERTER GENERATOR COVERINTRODUCTION
INTRODUCTION
Congratulations on your purchase of a Champion Power
Equipment (CPE) product. CPE designs, builds, and
supports all of our products to strict specifications and
guidelines. With proper product knowledge, safe use,
and regular maintenance, this product should bring
years of satisfying service.
Every effort has been made to ensure the accuracy and
completeness of the information in this manual at the
time of publication, and we reserve the right to change,
alter and/or improve the product and this document at
any time without prior notice.
CPE highly values how our products are designed,
manufactured, operated, and serviced as well as
providing safety to the operator and those around
the generator. Therefore, it is IMPORTANT to review
this product manual and other product materials
thoroughly and be fully aware and knowledgeable of
the assembly, operation, dangers and maintenance of
the product before use. Fully familiarize yourself, and
make sure others who plan on operating the product
fully familiarize themselves too, with the proper safet y
and operation procedures before each use. Please
always exercise common sense and always err on the
side of caution when operating the product to ensure no
accident, property damage, or injury occurs. We want
you to continue to use and be satisfied with your CPE
product for years to come.
When contacting CPE about parts and/or service, you
will need to supply the complete model and serial
numbers of your product. Transcribe the information
found on your product’s nameplate label to the table.
DATE OF PURCHASE
PURCHASE LOCATION
SAFETY DEFINITIONS
The purpose of safety symbols is to attract your
attention to possible dangers. The safety symbols,
and their explanations, deserve your careful attention
and understanding. The safety warnings do not by
themselves eliminate any danger. The instructions
or warnings they give are not substitutes for proper
accident prevention measures.
DANGER
DANGER indicates a hazardous situation which,
if not avoided, will result in death or serious injury.
WARNING
WARNING indicates a hazardous situation which, if
not avoided, could result in death or serious injury.
CAUTION
CAUTION indicates a hazardous situation which,
if not avoided, could result in minor or moderate
injury.
CPE TECHNICAL SUPPORT TEAM
1-877-338-0999
MODEL NUMBER
100603
SERIAL NUMBER
NOTICE
NOTICE indicates information considered important,
but not hazard-related (e.g., messages relating to
property damage).
Always shut generator off before any fueling or
maintenance procedures.
WARNING
NEVER position the refueling door on the same side
of the generator as the exhaust muffler. Spilled
gasoline can result in fire.
WARNING
NEVER block or cover the generator exhaust muffler
in any way. Storm Shield canopy must be installed
above the generator’s exhaust muffler. Install Storm
Shield electrical aprons so that they CANNOT block
exhaust in any way. Keep the Storm Shield canopy
at least 6 inches away from direct contact with the
exhaust.
WARNING
Never install the Kevlar® strap over, or direct line
of, the generator exhaust muffler.
CAUTION
Always grasp fiberglass rods firmly during
installation to avoid the whipping motion that can
occur when a bent fiberglass rod is mistakenly
released.
CAUTION
Avoid using your portable generator in hurricane
force winds above 70mph (112.7 km/h).
NOTICE
Should generator handle cause significant
stretching of the elastic straps when extended;
it is advisable to release the elastics straps on
the handle side of the generator before extending
generator handles.
NOTICE
Should Storm Shield cover block pull star ter, it is
advisable to release the elastic straps on the pull
starter side and temporarily move the Storm Shield
canopy out of the way.
WARNING
Never use the Storm Shield on a generator in a
moving vehicle.
CAUTION
Over tightening ratchet buckle should be avoided.
The ratchet buckle and strap are capable of
tremendous forces that can snap the molded
sections and mar the generator case if over
tightened.
NOTICE
When using Storm Shield during snow storms, it
is recommended to periodically brush away any
accumulation that blocks the top vent.
4
100603 - INVERTER GENERATOR COVERPACKAGE CONTENTS
PACKAGE CONTENTS
Storm Shield is suitable for inverter case perimeters
up to 112"
Storm Shield 10k sized Canopy (Standard or Extreme
Edition) including electrical covering aprons .............. 1
The Storm Shield assembly can be removed for
maintenance - release the ratchet buckle and carefully
lift the entire assembly off the inverter and place aside.
Reverse the operation to reinstall.
Transport
For transport remove the Storm Shield Canopy, Shield
Frame and the E xtender Arms; leave the Angle Brace
strap mount in place.
Strap It: Install the Ratchet Strap
Mount
NOTICE
The following steps are done for initial installation.
Once installed the first time, the entire strapped
assembly can be taken off and reinstalled quickly
and easily.
Getting Familiar with the Angle Brace and Extender
Arms
INSTALLATION OVERVIEW
The Storm Shield 100603 installs in three easy steps:
Strap it: Install Ratchet Buckle, Angle Braces, and
Extension Arms.
Frame it: Install frame rod to the center connector, then
into the correct hole in the Extender Arm, and repeat on
all four corners.
Cover it: Slide the Storm Shield canopy over the frame,
then secure by sliding the elastic straps under the
Extender Arm.
Important Usage Tips:
Storage
The Storm Shield can be left installed for generator
storage, or easily removed and stored separately. We
recommend releasing the elastic straps when storing
away from wind.
Figure 1: Corner Mount Components
The Angle Brace and Extension arms work together
with the Kevlar ratchet buckle system to create a stable
and strong mounting point for the Storm Shield on your
inverter generator. Please familiarize yourself with these
components:
–Kevlar strap – this strap is black and 1" wide. It is
installed through the Angle Braces. It is attached to
a ratchet buckle for tightening the assembly to your
inverter case.
5
Loading...
+ 11 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.