6000 Starting Watts / 5000 Running Watts
Electric Start
PORTABLE GENERATOR
MODEL NUMBER
71330
10006 Santa Fe Springs Road
SAVE THESE INSTRUCTIONS
Important Safety Instructions
are included in this manual.
MADE IN CHINA
REV 71330-20130330
www.championpowerequipment.com
Santa Fe Springs CA 90670
USA / 1-877-338-0999
AN IMPORTANT MESSAGE ABOUT TEMPERATURE:
Your Champion Power Equipment product is designed and rated for continuous operation at ambient temperatures up to
40°C (104°F). When your product is needed your product may be operated at temperatures ranging from -15°C (5°F) to
50°C (122°F) for short periods. If the product is exposed to temperatures outside this range during storage, it should be
brought back within this range before operation. In any event, the product must always be operated outdoors, in a
well-ventilated area and away from doors, windows and other vents.
Have questions or need assistance?
Do not return this product to the store!
WE ARE HERE TO HELP!
Visit our website:
www.championpowerequipment.com
for more info:
• Product Info & Updates
• Frequently Asked Questions
– or –
Call our Customer Care Team Toll-Free at:
1-877-338-0999
• Tech Bulletins
• Product Registration
WARNING:
The Engine Exhaust from this product contains chemicals known to the State of California
to cause cancer, birth defects or other reproductive harm.
*We are always working to improve our products. Therefore, the enclosed product may differ slightly from the image on the cover.
Congratulations on your purchase of a Champion
Power Equipment generator. CPE designs and builds
generators to strict specifications. With proper use and
maintenance, this generator will bring years of satisfying
service.
Portable Power Generator
This unit is a liquid petroleum gas (LPG) engine driven,
alternating current (AC) generator. It is designed to
supply electrical power for lighting, appliances, tools and
similar equipment.
Record the model and serial numbers as well as date and place of purchase for future reference. Have this
information available when ordering parts and when making technical or warranty inquiries.
Accessories
Champion Power Equipment manufactures and sells
accessories designed to help you get the most from
your purchase. To find out more about our covers, power
cables, please visit our web site at:
www.championpowerequipment.com
This Booklet
Every effort has been made to ensure the accuracy and
completeness of the information in this manual. We reserve
the right to change, alter and/or improve the product and
this document at any time without prior notice.
Champion Power Equipment Support
1-877-338-0999
Model Number
71330
Serial Number
Date of Purchase
Purchase Location
For O il Typ e see ‘Add Engine Oil‘ section. For Fuel Typ e see ‘Fuel‘ section.
1REV 71330-20130330
71330 ENGLISH
MANUAL CONVENTIONS
This manual uses the following symbols to help differentiate between different kinds of information. The safety symbol
is used with a key word to alert you to potential hazards in operating and owning power equipment.
Follow all safety messages to avoid or reduce the risk of serious injury or death.
DANGER
DANGER indicates an imminently hazardous
situation which, if not avoided, will result in death
or serious injury.
WARNING
WARNING indicates a potentially hazardous
situation which, if not avoided, could result in
death or serious injury.
CAUTION
CAUTION indicates a potentially hazardous
situation which, if not avoided, may result in minor
or moderate injury.
CAUTION
CAUTION used without the safety alert symbol
indicates a potentially hazardous situation which, if
not avoided, may result in property damage.
NOTE
If you have questions regarding your generator, we can
help. Please call our help line at 1-877-338-0999.
REV 71330-20130330 2
SAFETY RULES
ENGLISH71330
WARNING
Read this manual thoroughly before operating your
generator. Failure to follow instructions could result
in serious injury or death.
WARNING
The engine exhaust from this product contains
chemicals known to the state of California to cause
cancer, birth defects, or other reproductive harm.
DANGER
Generator exhaust contains carbon monoxide, a
colorless, odorless, poison gas. Breathing carbon
monoxide will cause nausea, dizziness, fainting or
death. If you start to feel dizzy or weak, get to fresh
air immediately.
Operate generator outdoors only in a well ventilated
area.
DO NOT operate the generator inside any building,
including garages, basements, crawlspaces and
sheds, enclosure or compartment, including the
generator compartment of a recreational vehicle.
DO NOT allow exhaust fumes to enter a confined
area through windows, doors, vents or other
openings.
DANGER CARBON MONOXIDE: using a generator
indoors CAN KILL YOU IN MINUTES.
DANGER
Rotating parts can entangle hands, feet, hair,
clothing and/or accessories.
Traumatic amputation or severe laceration can result.
DANGER
Generator produces powerful voltage.
DO NOT touch bare wires or receptacles.
DO NOT use electrical cords that are worn, damaged
or frayed.
DO NOT operate generator in wet weather.
DO NOT allow children or unqualified persons to
operate or service the generator
Use a ground fault circuit interrupter (GFCI) in damp
areas and areas containing conductive material such
as metal decking.
Use approved transfer equipment to isolate generator
from your electric utility and Notify your utility
company before connecting your generator to your
power system.
WARNING
Sparks can result in fire or electrical shock.
When servicing the generator:
Disconnect the spark plug wire and place it where it
cannot contact the plug.
DO NOT check for spark with the plug removed.
Use only approved spark plug testers.
WARNING
Running engines produce heat. Severe burns can
occur on contact.
Combustible material can catch fire on contact.
DO NOT touch hot surfaces.
Avoid contact with hot exhaust gases.
Allow equipment to cool before touching.
Maintain at least three feet of clearance on all sides
to ensure adequate cooling.
Maintain at least five feet of clearance from
combustible materials.
WARNING
Keep hands and feet away from rotating parts.
Tie up long hair and remove jewelry.
Operate equipment with guards in place.
DO NOT wear loose-fitting clothing, dangling
drawstrings or items that could become caught.
3REV 71330-20130330
Medical and Life Support Uses.
In case of emergency, call 911 immediately.
NEVER use this product to power life support
devices or life support appliances.
NEVER use this product to power medical devices
or medical appliances.
Inform your electricity provider immediately if you
or anyone in your household depends on electrical
euipment to live.
Inform your electrical provider immediately if a
loss of power would cause you or anyone in your
household to experience a medical emergency.
71330 ENGLISH
SAFETY RULES
DANGER
LIQUID PETROLEUM GAS (LPG) IS HIGHLY
FLAMMABLE AND EXPLOSIVE.
Fire or explosion can cause severe burns or death.
Unintentional startup can result in entanglement,
traumatic amputation or laceration.
Liquefied Petroleum Gas (LPG):
– LPG IS HIGHLY FLAMMABLE AND EXPLOSIVE.
– Flammable gas under pressure can cause a fire
or explosion if ignited.
– LPG is heavier than air and can settle in low
places while dissipating.
– LPG has a distinctive odor added to help detect
potential leaks quickly.
– In any petroleum gas fire, flames should not be
extinguished unless by doing so the fuel supply
valve can be turned OFF. This is because if a
fire is extinguished and a supply of fuel is not
turned OFF, then an explosion hazard could be
created.
– When exchanging LPG cylinders, be sure the
cylinder valve is of the same type.
– Always keep the LPG cylinder in an upright
position.
When starting the generator:
DO NOT attempt to start a damaged generator.
Make certain that the gas supply, air filter, spark
plug, fuel lines and exhaust system are properly in
place.
Make certain that the generator is resting firmly on
level ground.
When operating the generator:
DO NOT move or tip the generator during operation.
DO NOT tip the generator or allow oil to spill.
When transporting or servicing the generator:
Make certain that the fuel shutoff valve is in the off
position and the LPG cylinder is not attached.
Disconnect the spark plug wire.
When storing the generator:
Store away from sparks, open flames, pilot lights,
heat and other sources of ignition.
WARNING
Rapid retraction of the starter cord will pull hand and
arm towards the engine faster than you can let go.
Unintentional startup can result in entanglement,
traumatic amputation or laceration.
Broken bones, fractures, bruises or sprains could result.
When starting engine, pull the starter cord slowly
until resistance is felt and then pull rapidly to avoid
kickback.
DO NOT start or stop the engine with electrical
devices plugged in.
CAUTION
Exceeding the generator’s running capacity can
damage the generator and/or electrical devices
connected to it.
DO NOT overload the generator.
Start the generator and allow the engine to stabilize
before connecting electrical loads.
Connect electrical equipment in the off position,
and then turn them on for operation.
Turn electrical equipment off and disconnect before
stopping the generator.
DO NOT tamper with the governed speed.
DO NOT modify the generator in any way.
CAUTION
Improper treatment or use of the generator can
damage it, shorten its life and void your warranty.
Use the generator only for intended uses.
Operate only on level surfaces.
DO NOT expose generator to excessive moisture,
dust, or dirt.
DO NOT allow any material to block the cooling slots.
If connected devices overheat, turn them off and
disconnect them from the generator.
DO NOT use the generator if:
– Electrical output is lost
– Equipment sparks, smokes or emits flames
– Equipment vibrates excessively
WARNING
Operation of this equipment may create sparks that
can start fires around dry vegetation.
A spark arrestor may be required. The operator
should contact local fire agencies for laws or
regulations relating to fire prevention requirements.
REV 71330-20130330 4
ENGLISH 71330
CONTROLS AND FEATURES
Read this owner’s manual before operating your generator. Familiarize yourself with the location and function of the
controls and features. Save this manual for future reference.
Generator
9
1
10
8
2
3
4
(1) Fuel Valve – Used to turn fuel supply on and off to
engine.
(2) Choke – Used to start the engine.
(3) Air Filter – Protects the engine by filtering dust
and debris from the intake air.
7
6
5
(6) Battery – Used to start the engine. Provides 12V
DC to the electric starter and receiver control
module.
(7) Power Panel – See “Power Panel” section.
(8) Handle
(4) Recoil Starter – Used to manually start the engine.
(5) Oil Filler Cap – Check and fill engine oil level.
5REV 71330-20130330
(9) LPG Hose Connector
(10) Primer Button
71330 ENGLISH
Power Panel
CONTROLS AND FEATURES
123
(1) Ignition Switch – Used to start or stop the
generator.
(2) Circuit Breakers – Protects the generator against
electrical overloads. Push to reset breaker.
(3) Intelligauge™ – Three mode digital meter for
displaying running hours, voltage and hertz.
(4) 120 Volt AC, 30 Amp Twist-Lock Receptacle
(NEMA L5-30R) – May be used to supply electrical
power for the operation of 120 Volt AC, 30 Amp,
single phase 60 Hz electrical loads.
457
(5) 120/240 Volt AC, 30 Amp Twist-Lock Receptacle
(NEMA L14-30R) – May be used to supply
electrical power for the operation of 120
and/or 240 Volt AC, 30 Amp, single phase 60 Hz
electrical loads.
(6) 120 Volt AC, 20 Amp Duplex (2)
(NEMA 5-20R) – May be used to supply electrical
power for the operation of 120 Volt AC, 20 Amp,
single phase 60 Hz electrical loads.
(7) Ground Terminal – Consult an electrician for local
grounding regulations.
6
REV 71330-20130330 6
CONTROLS AND FEATURES
Parts Included
Your 71330 LPG Powered Generator ships with the
following parts:
Wheel Kit
– 10 in. Wheel ..........................2
– Flange Bolt (M10x115 for Wheel) ............2
– Bushing ..............................2
– Flat Washer 10.........................2
– Nut (M10 ) ............................2
– Support Leg w/Vibration Mounts .............1
– Flange Bolt (M8x16 for Support Leg) ..........2
– Nut (M8 for Support Leg)..................2
– Handle ..............................2
– Flange Bolt (M8x45 for Handle) .............2
– Nylon Washers (for Handle) ................4
– Nut (M8 for Handle) .....................2
ENGLISH71330
Other
– 5 ft. LPG Hose .........................1
– Oil .......................1.16 qt. (1.1 L)
– Oil Funnel ............................1
– Spark Plug Socket.......................1
– Cap Screw (M5x10 for Battery Terminals) .......2
– Nut (M5) .............................2
(Battery Bolts)
7REV 71330-20130330
71330 ENGLISH
ASSEMBLY
Your generator requires some assembly. This unit ships
from our factory without oil. It must be properly serviced
with fuel and oil before operation.
If you have any questions regarding the assembly of your
generator, call our help line at 1-877-338-0999. Please
have your serial number and model number available.
Remove the Generator from the Shipping Carton
1. Set the shipping carton on a solid, flat surface.
2. Remove everything from the carton except the
generator.
3. Carefully cut each corner of the box from top to
bottom. Fold each side flat on the ground to provide a
surface area to install the wheel kit and support leg.
Install the Wheel Kit
CAUTION
The wheel kit is not intended for over-the-road use.
You will need the following tools to install the wheels:
• 17 mm wrench OR adjustable wrench (not included)
• Socket wrench with a 16 mm socket (not included)
• Pliers (not included)
1. Before connecting fuel and adding oil, tip the generator
on it’s side.
2. Slide the M10x115 wheel bolt through the washer,
sleeve and wheel.
3. Slide the bolt through the mount point on the frame.
4. Fasten securely with the M10 nut.
5. Repeat steps 2-4 to attach the second wheel.
Install the Support Leg
1. Attach the support leg to the generator frame with
cap screws (M8x16) and nuts (M8).
2. Tip the generator slowly so that it rests on the
wheels and support leg.
Install the Handles
1. Line up the holes on the handle with the holes on
the frame.
2. Thread nylon washer through M8x45 flange bolt.
3. Insert bolt through handle and frame.
4. Thread nylon washer onto bolt after it is through the
handle and frame.
5. Secure with M8 nut. Tighten. DO NOT over tighten.
6. Repeat steps 1-5 for second handle.
Connect the Battery
1. Remove the protective cover from the red (+) lead on
the bat tery.
2. Attach the red (+) lead to the red (+) terminal on the
battery with the cap screw (M5x10) and secure with
the lock washer (M5).
3. Repeat steps 1-2 for the black (–) battery lead.
REV 71330-20130330 8
ASSEMBLY
ENGLISH71330
Add Engine Oil
CAUTION
DO NOT attempt to crank or start the engine before
it has been properly filled with the recommended
type and amount of oil. Damage to the generator as
a result of failure to follow these instructions will
void your warranty.
NOTE
The recommended oil type is 10W-30 automotive
oil.
1. Place the generator on a flat, level surface.
Add Engine Oil Cont’d.
CAUTION
The engine is equipped with a low oil shut-off and
will stop when the oil level in the crankcase falls
below the threshold level.
NOTE
Check oil often during the break-in period. Refer to the
Maintenance section for recommended service intervals.
NOTE
The generator rotor has a sealed, pre-lubricated ball
bearing that requires no additional lubrication for
the life of the bearing.
2. Remove oil fill cap/dipstick to add oil.
3. Add up to 1.16 qt. (1.1 L) of oil and replace oil fill
cap/dipstick. DO NOT OVERFILL.
4. Check engine oil level daily and add as needed.
9REV 71330-20130330
71330 ENGLISH
ASSEMBLY
Connecting Liquid Petroleum Gas (LPG) Cylinder
1. Make sure the fuel valve on the generator is in the
off position.
2. Attach the LPG hose (included) to the LPG hose
connector on the side of the generator and tighten
with a 19 mm or adjustable wrench. (A)
Important: DO NOT use tape or any other type of
sealant to seal LPG hose connection.
3. Remove the safety plug or cap from the cylinder
valve.
4. Attach the other end of the hose to the LPG
connector on the cylinder and hand tighten.
A
NOTE
– Use only standard 20 or 30 pound capacity LP
tanks with Type 1, right hand Acme threads.
– Verify the requalification date on the tank has
not expired.
– All new cylinders must be purged of air and
moisture prior to filling. Used cylinders that have
not been plugged or kept closed must also be
purged.
– The purging process should be done by a LPG
supplier. (Cylinders from an exchange supplier
should have been purged and filled properly
already).
– Always position the cylinder so the connection
between the valve and the gas inlet won’t cause
sharp bends or kinks in the hose.
CAUTION
Connecting LPG Cylinder Cont’d.
CAUTION
Use approved LPG cylinders equipped with an
OPD (overfilling prevention device) valve. Always
keep the cylinder in a vertical position with the
valve on top and installed at ground level on a flat
surface Cylinders must not be installed near any
heat source and should not be exposed to sun, rain,
and dust. When transporting and storing, turn off
the cylinder valve and fuel valve, and disconnect
the cylinder. Plug the outlet, usually by a plastic
protective cap, if one is available. Keep cylinders
away from heat and ventilated when in a vehicle.
WARNING
If there is a strong smell of gas: Close off the gas
supply at the cylinder. Use soapy water, which will
produce a large bubble at the point of any leak, to
check the hose, and connections on the cylinder valve
and the generator. Do not smoke or light a cigarette,
or check for leaks using a match, open flame source
or lighter. Contact a qualified technician to inspect
and repair the LPG system if a leak is found, before
using the generator.
Grounding
Your generator must be properly connected to an
appropriate ground to help prevent electric shock.
WARNING
Failure to properly ground the generator can result
in electric shock.
A ground terminal connected to the frame of the generator
has been provided on the power panel. For remote
grounding, connect of a length of heavy gauge
(12 AWG minimum) copper wire between the generator
ground terminal and a copper rod driven into the ground.
We strongly recommend that you consult with a qualified
electrician to ensure compliance with local electrical codes.
Do not allow children to tamper or play with the
cylinder or hose connections.
REV 71330-20130330 10
OPERATION
ENGLISH71330
Generator Location
NEVER operate the generator inside any building,
including garages, basements, crawlspaces and sheds,
enclosure or compartment, including the generator
compartment of a recreational vehicle. Please consult
your local authority. In some areas, generators must
be registered with the local utility. Generators used at
construction sites may be subject to additional rules and
regulations. Generators should be on a flat, level surface
at all times. (Even while not in operation) Generators
must have at least five feet of clearance from all
combustible material. In addition to clearance from all
combustible material, generators must also have at least
three feet of clearance on all sides to allow for adequate
cooling, maintenance and servicing. Generators should
never be started or operated in the back of a SUV,
camper, trailer, in the bed of a truck (regular, flat or
otherwise), under staircases/stairwells, next to walls or
buildings, or in any other location that will not allow for
adequate cooling of the generator and/or the muffler.
DO NOT contain generators during operation. Allow
generators to properly cool before transport or storage.
Place the generator in a well-ventilated area. DO NOT
place the generator near vents or intakes where exhaust
fumes could be drawn into occupied or confined
spaces. Carefully consider wind and air currents when
positioning generator.
Failure to follow proper safety precautions may void
manufacturer’s warranty.
WARNING
Do not operate or store the generator in rain, snow,
or wet weather.
Using a generator or electrical appliance in wet
conditions, such as rain or snow, or near a pool or
sprinkler system, or when your hands are wet, could
result in electrocution.
WARNING
During operation the muffler and exhaust fumes
produced will become hot. If adequate cooling and
breathing space are not supplied, or if the generator
is blocked or contained, temperatures can become
extremely heated and may lead to fire.
Grounding
The generator system ground connects the frame to the
ground terminals on the power panel.
– The generator (stator winding) is isolated from the
frame and from the AC receptacle ground pin.
– Electrical devices that require a grounded receptacle
pin connection will not function if the receptacle
ground pin is not functional.
Surge Protection
CAUTION
Voltage fluctuation may impair the proper
functioning of sensitive electronic equipment.
Electronic devices, including computers and many
programmable appliances use components that are
designed to operate within a narrow voltage range and
may be affected by momentary voltage fluctuations.
While there is no way to prevent voltage fluctuations, you
can take steps to protect sensitive electronic equipment.
Surge suppressors come in single- or multi-outlet
styles. They’re designed to protect against virtually
all short-duration voltage fluctuations.
Starting the Engine
1. Make certain the generator is on a flat, level surface.
2. Disconnect all electrical loads from the generator.
Never start or stop the generator with electrical
devices plugged in or turned on.
3. Make certain the LPG cylinder is in the upright
position and on a flat, level surface.
4. Open the valve on the fuel source.
5. Open the FUEL VALVE on the generator.
6. Press and hold the PRIMER BUTTON for 1-2
seconds.
7. Move the CHOKE LEVER to CHOKE. *Only required if
temp. below 40˚F (4˚C).
8. Flip the ignition switch to the “ON” position.
9. ELECTRIC START: Press and hold the ignition switch
to the “START” position. Release as the engine
begins to roll over. If the engine fails to start within
five seconds, release the switch and wait at least ten
seconds before attempting to start the engine again.
11REV 71330-20130330
71330 ENGLISH
OPERATION
Starting the Engine Cont’d.
10. RECOIL START: Slowly pull the RECOIL HANDLE 2
times, then pull quickly to START the engine.
11. As engine starts, move CHOKE LEVER to RUN. *Only
required if temp. below 40˚F (4˚C).
12. If the engine fails to start the first time, repeat steps
6-11.
NOTE
If the engine starts but does not run make certain
that the generator is on a flat, level surface. The
engine is equipped with a low oil sensor that will
prevent the engine from running when the oil level
falls below a critical threshold.
NOTE
If the temperature is below 40˚F (4˚C) the choke
may be used during the engine warm-up cycle. The
CHOKE LEVER should always set to RUN when
generator has reached operating temperature and is
running smoothly.
NOTE
Keep choke lever in “Choke” position for only 2 pulls
of the recoil starter. After 2 pulls, move choke lever
to the “Run” position for up to the next 3 pulls of
the recoil starter. Too much choke leads to an overrich condition due to the lack of incoming air. This
will cause the engine not to start.
Connecting Electrical Loads
1. Let the engine stabilize and warm up for a few
minutes after starting
2. Plug in and turn on the desired 120/240 Volt AC
single phase, 60 Hz electrical loads.
– DO NOT connect 3-phase loads to the generator.
– DO NOT connect 50 Hz loads to the generator.
– DO NOT overload the generator.
NOTE
Connecting a generator to your electric utility
company’s power lines or to another power source
may be against the law. In addition this action,
if done incorrectly, could damage your generator
and appliances and could cause serious injury or
even death to you or a utility worker who may be
working on nearby power lines. If you plan to run a
portable electric generator during an outage, please
notify your electric utility company immediately
and remember to plug your appliances directly
into the generator. Do not plug the generator into
any electric outlet in your home. Doing so could
create a connection to the utility company power
lines. You are responsible for ensuring that your
generator’s electricity does not feed back into the
electric utility power lines.
If the generator will be connected to a building
electrical system, consult your local utility company
or a qualified electrician. Connections must isolate
generator power from utility power and must comply
with all applicable laws and codes.
NOTE
The supplied 12V 15AH battery does re-charge
while the engine is running, but it is also
recommended that the battery be fully charged at
least once per month.
REV 71330-20130330 12
OPERATION
ENGLISH71330
Stopping the Engine
1. Turn off and unplug all electrical loads. Never start
or stop the generator with electrical devices plugged
in or turned on.
2. Let the generator run at no-load for several minutes
to stabilize internal temperatures of the engine and
generator.
3. Close the OPD valve on the LPG cylinder.
4. Let the engine run until fuel starvation has stopped
the engine. This usually takes a few seconds.
5. Turn the Fuel Valve on the generator to the “OFF”
position.
Important: Always ensure that the Fuel Valve and the
cylinder OPD valve are in the “OFF” position when the
engine is not in use.
NOTE
If the engine will not be used for a period of two (2) weeks
or longer, please see the Storage section for proper engine
and fuel storage.
Do Not Overload Generator
Capacity
Follow these simple steps to calculate the running and
starting watts necessary for your purposes.
1. Select the electrical devices you plan on running at
the same time.
2. Total the running watts of these items. This is
the amount of power you need to keep your items
running.
3. Identify the highest starting wattage of all devices
identified in step 1. Add this number to the number
calculated in step 2. Surge wattage is the extra
burst of power needed to start some electric driven
equipment. Following the steps listed under “Power
Management” will guarantee that only one device
will be starting at a time.
Power Management
Use the following formula to convert voltage and
amperage to watts:
Operation at High Altitude
The density of air at high altitude is lower than at sea
level. Engine power is reduced as the air mass and
air-fuel ratio decrease. Engine power and output will
be reduced approximately 3½% for every 1000 feet of
elevation above sea level. This is a natural trend and
cannot be changed by adjusting the engine.
Volts x Amps = Watts
To prolong the life of your generator and attached
devices, follow these steps to add electrical load:
1. Start the generator with no electrical load attached
2. Allow the engine to run for several minutes to
stabilize.
3. Plug in and turn on the first item. It is best to attach
the item with the largest load first.
4. Allow the engine to stabilize.
5. Plug in and turn on the next item.
6. Allow the engine to stabilize.
7. Repeat steps 5-6 for each additional item.
NOTE
Never exceed the specified capacity when adding
loads to the generator.
13REV 71330-20130330
71330 ENGLISH
MAINTENANCE AND STORAGE
The owner/operator is responsible for all periodic
maintenance.
WARNING
Never operate a damaged or defective generator.
WARNING
Tampering with the factory set governor will void
your warranty.
WARNING
Improper maintenance will void your warranty.
NOTE
Maintenance, replacement, or repair of emission
control devices and systems may be performed
by any non-road engine repair establishment or
individual.
Complete all scheduled maintenance in a timely manner.
Correct any issue before operating the generator.
Oil Cont’d.
NOTE
Once oil has been added, a visual check should show
oil about 1-2 threads from running out of the fill hole.
If using the dipstick to check oil level, DO NOT screw
in the dipstick while checking.
Spark Plugs
1. Remove the spark plug cable from the spark plug.
2. Use the spark plug tool that shipped with your
generator to remove the plug.
3. Inspect the electrode on the plug. It must be clean
and not worn to produce the spark required for
ignition.
4. Make certain the spark plug gap is 0.7 - 0.8 mm or
(0.028 - 0.031 in.).
NOTE
For service or parts assistance, contact our help
line at 1-877-338-0999
Engine Maintenance
To prevent accidental starting, remove and ground spark
plug wire before performing any service.
Oil
Change oil when the engine is warm. Refer to the oil
specification to select the proper grade of oil for your
operating environment.
1. Remove the oil drain plug with a 15 mm socket and
extension.
2. Allow the oil to drain completely.
3. Replace the drain plug.
4. Remove oil fill cap/dipstick to add oil.
5. Add 1.16 qt (1.1 L) of oil and replace oil fill
cap /dipstick. DO NOT OVERFILL.
6. Dispose of used oil at an approved waste
management facility.
0.7 - 0.8 mm
0.028 - 0.031 in.
5. Refer to the spark plug recommendation chart when
replacing the plug.
6. Carefully thread the plug into the engine.
7. Use the spark plug tool to firmly install the plug.
8. Attach the spark plug wire to the plug.
Air Filter
1. Remove the snap-on cover holding the air filter to
the assembly.
2. Remove the foam element.
3. Wash in liquid detergent and water. Squeeze
thoroughly dry in a clean cloth.
4. Saturate in clean engine oil.
5. Squeeze in a clean, absorbent cloth to remove all
excess oil.
6. Place the filter in the assembly.
7. Reattach the air filter cover and snap in place.
REV 71330-20130330 14
MAINTENANCE AND STORAGE
ENGLISH71330
Spark Arrester
1. Allow the engine to cool completely before servicing
the spark arrester.
2. Remove the three screws holding the cover plate
which retains the end of the spark arrester to the
muffler.
3. Remove the spark arrester screen.
4. Carefully remove the carbon deposits from the spark
arrester screen with a wire brush.
5. Replace the spark arrester if it is damaged.
6. Position the spark arrester in the muffler and attach
with the three screws.
CAUTION
Failure to clean the spark arrester will result in degraded
engine performance.
Maintenance Schedule
Follow the service intervals indicated in the following
maintenance schedule.
Service your generator more frequently when operating
in adverse conditions.
Contact our helpline at 1-877-338-0999 to locate the
nearest Champion Power Equipment certified service
dealer for your generator or engine maintenance needs.
Every 8 hours or daily
Check oil level
Clean around air intake and muffler
Check hoses for leaks
First 5 Hours
Change oil
Every 50 hours or every season
Clean air filter
Change oil if operating under heavy load or in hot environments
Every 100 hours or every season
Change oil
Clean/Adjust spark plug
Check/Adjust valve clearance*
Clean spark arrester
NOTE
Federal and local laws and administrative requirements
indicate when and where spark arresters are required.
When ordered, spark arresters are required for operation
of this generator in National Forest lands. In California,
this generator must not be used on any forest- covered
land, brush-covered land, or grass- covered land unless
the engine is equipped with a spark arrester.
Cleaning
CAUTION
DO NOT spray engine with water.
Water can contaminate the fuel system.
Use a damp cloth to clean exterior surfaces of the engine.
Use a soft bristle brush to remove dirt and oil.
Use an air compressor (25 PSI) to clear dirt and debris
from the engine.
Adjustments
The air-fuel mixture is not adjustable. Tampering with
the governor can damage your generator and your
electrical devices and will void your warranty. CPE
recommends that you contact our service line at
1-877-338-0999 for all other service and/or adjustment
needs.
*To be performed by knowledgeable, experienced owners or
Champion Power Equipment certified dealers.
Generator Maintenance
Make certain that the generator is kept clean and stored
properly. Only operate the unit on a flat, level surface in
a clean, dry operating environment. DO NOT expose the
unit to extreme conditions, excessive dust, dirt, moisture
or corrosive vapors.
CAUTION
DO NOT use a garden hose to clean the generator.
Water can enter the generator through the cooling
slots and damage the generator windings.
Use a damp cloth to clean exterior surfaces of the generator.
Use a soft bristle brush to remove dirt and oil.
Use an air compressor (25 PSI) to clear dirt and debris
from the generator.
Inspect all air vents and cooling slots to ensure that they
are clean and unobstructed.
15REV 71330-20130330
71330 ENGLISH
MAINTENANCE AND STORAGE
Storage
Generator Storage
1. Be sure all appliances are disconnected from the
generator.
2. Start up and run the generator for a short time.
3. Turn the OPD valve on the cylinder to the “Closed”
position.
4. Let the generator run until fuel starvation has
stopped the engine. This usually takes a few
seconds.
5. Turn the fuel valve on the generator to the “Off”
position.
6. The generator needs to cool completely before
cleaning and storage.
7. Disconnect the fuel hose from the LPG cylinder.
8. Clean the generator according to the maintenance
section.
9. Change the oil.
10. Remove the spark plug and pour about 1 ⁄2 ounce
of oil into the cylinder. Crank the engine slowly to
distribute the oil and lubricate the cylinder.
11. Reattach the spark plug.
12. Store the unit in a clean, dry place out of direct
sunlight.
DANGER
Generator exhaust contains odorless and colorless carbon
monoxide gas.
To avoid accidental or unintended ignition of your
generator during periods of storage, the following
precautions should be followed:
– When storing the generator for short or extended
periods of time make sure that the LPG cylinder
is disconnected from the generator and the Fuel
Valve is set in the OFF position.
WARNING
After a period (short or extended) of non-use
we recommend that you perform the following
maintenance procedures for utmost user safety:
– Check all hoses and fuel lines before each use
for any holes, cracking, abrasions, nicks, cuts, or
any other form of damage. If any hose or fuel line
is found to be damaged in any way, DO NOT use
the unit until the damaged part has been properly
replaced.
– DO NOT try and repair any worn or damaged hose
or fuel line, replace it with a new part ONLY.
– Always check for gas leaks every time a hose
or fuel line is replaced, or disconnected and
reconnected to any fuel fitting. This will ensure
that fuel is properly flowing to the unit and
eliminate possible hazards.
Generator Storage Cont’d.
NOTE
– Store LPG tank disconnected from fuel hose and
gener ator.
– Store LPG tank with the OPD valve in the “Closed”
position.
– Do not store LPG tank in or around extreme heat.
LPG gas is extremely flammable.
– Do not store LPG tank in or around extreme cold.
LPG gas will freeze.
WARNING
Contact with LPG from either the cylinder, excess from the
hose, or from any leaks may cause freeze burns on skin. Do
not touch or spill LPG on bare skin.
Battery
This product is equipped with an automatic battery
charging circuit. The battery will receive charging voltage
when the engine is running. The battery will maintain a
proper charge if the unit is used on a regular basis (about
once every two weeks). If it is used less frequently, the
battery should be connected to a trickle charger or battery
maintainer to keep the battery properly charged. If the
battery is not able to start the engine, it can be started
by manually pulling the engine recoil cord. If the battery
voltage is extremely low, the charging circuit may not be
able to re-charge the battery. In this case, the battery
must be connected to a standard automotive style battery
charger for re-charging before it can be used.
Charge the Battery
For pressure washers equipped with batteries for electric
starting, proper battery maintenance and storage
should be followed. An automatic battery charger with
automatic trickle charging capability should be used to
charge the battery. Maximum charging rate should not
exceed 1.5 amps. Follow the instructions included with
the battery charger. The battery should be fully charged
at least once per month.
NOTE
A Float Charger will maintain the battery condition over
long storage periods.
Disconnect the Battery
1. Remove the protective cover from the black/negative
battery lead.
2. Disconnect the black/negative lead from the black/
negative terminal on the battery and store the cap
screw (M5x10) and lock washer (M5).
3. Repeat steps 1-2 for the red/positive battery lead.
Use only an approved LPG cylinder equipped with an
OPD valve.
Oil
Use 10W-30 automotive oil.
Oil capacity is up to 1.16 qt. (1.1 L).
DO NOT OVERFILL.
Please reference the following chart for recommended
oil types for use in the generator.
Make certain the spark plug gap is 0.7 - 0.8 mm or
(0.028 - 0.031 in.).
Maintenance Valve Clearance
– Intake: 0.13 – 0.17 mm (0.005 – 0.007 in.)
– Exhaust: 0.18 – 0.22 mm (0.007 – 0.009 in.)
Note: Tech bulletin regarding the valve adjustment
procedure is on www.championpowerequipment.com.
An Important Message About Temperature
Your Champion Power Equipment product is designed
and rated for continuous operation at ambient
temperatures up to 40°C (104°F). When your product is
needed your product may be operated at temperatures
ranging from -15°C (5°F) to 50°C (122°F) for short
periods. If the product is exposed to temperatures
outside this range during storage, it should be brought
back within this range before operation. In any event,
the product must always be operated outdoors, in a
well-ventilated area and away from doors, windows and
other vents.
17REV 71330-20130330
71330 ENGLISH
Wiring Diagram
SPECIFICATIONS
ST
G/Y
R
20A
CIRCUIT BREAKER
CIRCUIT BREAKER
G/Y
TERMINAL
EARTH
G/Y
B
G/Y
R
25A
Transition
G/Y
W
R
B
Y
DIODE
2
1
COMBINATION SW
B
B/W
FUSE
W
Y
SW
OIL LEVEL
CONTROL BOX BLOCK
B
10A
Br
B/W
W
R
Br
M
STARTER
B
BATTERY
B
DUPLEX B
5-20R
DUPLEX A
20A
L14-30R
B
B
CIRCUIT BREAKERCIRCUIT BREAKER
25A
L5-30R
R
W
W
R
W
W
G/Y
W
G/Y
W
CHARGE COIL
multi-purpose meter
W
B
B
R
R
B
IGNITION COIL
AVR
L
L
Y
Y
L
MW1
B
L
MW2
R
Y
FW
+
L
R
L
W
EXW
W
ENGINE BLOCK
6
GENERATOR BLOCK
5
4
3
2
COMBINATION SWITCH
1
ON
OFF
BROWN
BLACK WHITE
Br
B/W
BLACK
YELLOW
B
ST
Y
SPARKING PLUG
WHITE BLUE
INDIGO
GREEN YELLOW
WHITE GREEN
In
W/L
W/G
G/Y
RED
WHITE
BLUE
GREEN
L
R
G
W
REV 71330-20130330 18
SPECIfICATIONS
4
4
Parts Diagram
ENGLISH71330
0
2
1
2
22
9
1
3
2
4
2
31
35
36
37
38
0
3
29
32
4
3
3
3
5
1
25
6
2
27
19
182
8
11
10
9
8
7
6
19
8
1
5 1617
1
4
1
8
13
2
1
99
0
10
9
7
9
6
9
5
5
4
3
2
1
1
8
50
35
51
39
0
4
2
4
3
4
45
47
46
1
4
9
4
48
5
60
58
59
61
62
7
3
52
556
5
7
5
64
80
7
3
53
3
4
4
5
1
56
7
72
65
6
6
7
6
68
01
1
2
0
1
79
3
0
1
4
10
78
7
7
3
4
7
7
69
82
6
7
3
8
43
5
7
5
70
1539293949
09
8
87
8
99
5
8
86
8
84
19REV 71330-20130407
71330 ENGLISH
Parts List
#Part NumberDescriptionQty
146.690Engine1
2152.190005.01Rubber,Fore-Cover1
3152.190005.00Rubber,Fore-Cover1
152.192300.00Air Guide
4
1.5789.06 08Flange Bolt M6×8
5
152.191100.02Rotor Assembly
6
1.96.10Washer Ø10
7
1.724 4.10Spring Washer Ø10
8
152.1912 00 .23Stator Assembly
9
2.08.034Flange Bolt M10×265
10
152.1910 02.00Stator Cover
11
2.08.032Flange Bolt M6×179
12
152.190002.00End Housing
13
152.190200.04AVR
14
1.16674.0516Flange Bolt M5×16
15
122.190400.00Terminal Block
16
1.5783.0516B olt M5 ×16
17
1.97.1.05Washer Ø5
18
1.93.05Spring Washer Ø5
19
1.166 74. 0512 .2Flange Bolt M5×12
20
152.190003.00.76Generator End Cover
21
1.5783.0520Bolt M5×20
22
122.190004.01Pinch
23
152.190300.00Carbon Bursh Assembly
24
1.93.06Spring Washer Ø6
25
1.97.1.06Washer Ø6
26
2.08.035Flange Bolt M5×214
27
1.6175.05Nut M5
28
1.166 74. 0 820Flange Bolt M8×20
29
46.101300.00Spark Arrester Assembly
30
1.9074.4.0510Combination Screw M5×10
31
46.101000.00.2Muffler Assembly
32
46.100001.07Muffler Gasket
33
1.6175.08Nut M8
34
1.93.08Spring Washer Ø8
35
1.848.08Washer Ø8
36
1.6177.1.06Nut M6
37
45.090006.20Holder,Air Cleaner
38
2.06.023Clip
39
26.130 021.03Tracheal (250mm)
40
122.074000.01Cut-off Valve
41
152.07020 0.0 6.76Plate
42
1.5789.0612Flange Bolt M6×12
43
1.823.0408Screw M4×8
44
1.93.04Spring Washer Ø4
45
1.923.06Nut M6
46
1.97.1.04Washer Ø4
47
46.136000.03
48
2.05.050Clamp,Wire
49
1.5789.08 35Flange Bolt M8×35
50
2.03.040Big Washer Ø8
51
152.201200.00Straight Bottom Rubber
52
Pressure Reducing Valve
Assembly
#Part NumberDescriptionQty
1.862.06Lock Washer Ø6
53
5.19 00.0 26Grounding Line
54
152.201200.04Motor Mount Ⅱ
55
1
5
1
3
1
1
1
1
4
1
1
3
1
2
4
5
2
1
1
1
1
4
4
2
2
2
1
3
1
1
2
4
2
2
1
2
1
1
1
9
2
2
4
2
1
1
2
2
2
1.6177.1.08Nut M8
56
152.201200.03Motor Mount I
57
1.6182.10Nut M10
58
1.6177.1.10N ut M10
59
6.5.220.402.2Frame
60
152.201701.04.7610 in Wheel
61
253.200016.00Bush Ø10.5×69.5
62
1.5782.10115Bol t M10×115
63
1.90 74. 3.0 510Combination Screw M5×10
64
1.6177.1.05Nut M5
65
9.1000.150Battery 12V15AH
66
152.200904.00Pinch,Rubber
67
5.19 00.014Black Wire,Battery
68
5.19 00.0 21Red Wire,Battery
69
152.200013.01Jacket
70
1.5789.0816Flange Bolt M8×16
71
152.200002.01.2Support Leg
72
152.201400.00Vibration Mount
73
1.5789.0825Flange Bolt M8×25
74
26.130 021.0 4Tra ch eal
75
1.5789.08 45Flange Bolt M8×45
76
2.03.011Nylon Washers
77
122.200701.04.2Handle
78
152.200702.00Cover,Handle
79
152.201001.01Choke Plug
80
1.6187.1.08Nut M8
81
152.02.77.2Control Panel
82
5.1000.005.3Switch
83
5.1210.925Ac.25A Breaker
84
5.1210.920Ac.20A Breaker
85
5.14 30.0 02Intelligauge
86
5.1120 .0 0 8Receptacle L5-30R
87
1.9074.4.0414.1Combination Screw M4×14
88
1.6177.1.04 .1Nut M4
89
5.1120 .0 0 9Receptacle L14-30R
90
5.1120 .010Receptacle 5-20R Duplex
91
1.93.06.3Spring Washer Ø8
92
1.97.1.06.3Washer Ø8
93
1.5783.0622.3Bolt M6×22
94
1.6175.06 .3Nut M6
95
122.210003.01Plug
96
5.13 30 .118Sheath,Wire
97
152.210003.02Plug
98
1.9074.1.0538.2Combination Screw M5×38
99
152.210002.08Control Box
100
152.210003.04Plug
101
1.8 23 .0514Screw M5×14
102
5.1810.0 01Over Voltage Protector
103
5.1800.002Rectifier
104
2
1
1
8
1
2
2
1
2
2
2
2
2
1
1
1
1
3
2
1
2
2
1
2
4
2
2
2
2
1
1
2
2
1
1
8
8
1
2
2
2
1
2
1
1
1
3
1
1
1
1
1
REV 71330-20130407 20
SPECIFICATIONS
45
64
40
102
103
104
105
91
106
107
110
109
108
85
10
1
2
3
4
5
6
7
8
9
11
12
14
15
16
17
18
19
20
16
24
25
26
27
28
29
30
31
33
34
35
12
36
30
37
38
23
39
41
42
43
44
46
47
48
49
50
51
52
53
12
54
55
57
58
59
60
61
62
65
66
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
86
87
88
67
83
84
56
94
95
96
111
89
97
98
99
100
101
2
21
22
23
93
63
32
92
113
114
90
91
115
112
13
116
Engine Parts Diagram
ENGLISH71330
21REV 71330-20130330
71330 ENGLISH
#Part NumberDescriptionQty
121.061300.00Recoil Handle1
21.5789.0608Flange bolt M6× 84
46.061100.00.2Recoil Starter Cover1
3
45.060005.00Recoil Starter Spring1
4
45.061102.00Recoil Star ter Reel1
5
2.10. 00 3Rope (ø5×1550)1
6
45.060003.00 Spring,Ratchet2
7
45.060002.00Starter Ratchet (Iron)2
8
45.060009.00Spring,Ratchet Guide1
9
45.060007.00Ratchet Guide1
10
45.060008.00Screw, Ratchet Guide1
11
1.5789.0612Flange bolt M6×1212
12
2.06.006Clip ( ø7× ø1)2
13
46.08 0100.01.76Fan Cover1
14
2.02.007Nut (M16×1.5)1
15
1.5789.0629Flange bolt 6×294
16
45.060001.00Pulley, Starter1
17
46.123000.03Ignition Coil1
18
45.080001.00Cooling Fan1
19
46 .120100.02Flywheel (Electric Start EPA)1
20
45.030006.00Plate, Coil1
21
45.121000.00Coil, Charging1
22
2.11.0 07Oil Seal (ø35×ø52×8)2
23
2.05.050Wire clip1
24
45.030032.00Sheath, Wire1
25
2.03.023Washer (ø12.5×ø20 ×2)2
26
46.03 0100.01Crankcase 1
27
45.127000.01Oil Level Sensor1
28
1.5789.0 615Flange bolt 6×152
29
1.276.620 2Bearing 62022
30
45.050006.00Weight Balancer1
31
45.05 010 0.14Crankshaft1
32
46.030008.00Gasket, Crankcase Cover1
33
2.04.001Dowel Pin (ø9×14)2
34
46.080600.00Air Guide, Right Side1
35
1.276.6207Bearing 62071
36
46.031000.01Oil Dipstick Assembly1
37
45.030007.00Cover, Crankcase 1
38
1.5789.0840.0.8Flange bolt 8×407
39
2.03.021.1Washer (ø6.4×ø13×1)1
40
45.110013.00Shaft,Governor Gear1
41
45.11010 0.00Gear, Governor1
42
21.110 011.0 0Clip, Governor Gear1
43
45.110012.00Bushing, Governor Gear1
44
45.050200.00Connecting Rod1
45
46.050005.00Piston 1
46
2.09.004Circlip(ø21×ø1)2
47
45.050003.00Wrist Pin1
48
45.050303.00Ring, Oil 1
49
46.050302.00Ring, Second Piston 1
50
46.050301.00Ring,First Piston1
51
2.04.004Dowel Pin(ø12×20)2
52
46.030009.01
53
46.080 400.00Air Guide, Lower1
54
46.010100.0 0 Cylinder Head1
55
2.01.005Stud.Bolt (M8×49)2
56
2.15. 00 8Spark Plug (F7RTC)1
57
2.08.014Flange bolt 10×804
58
46.020002.00Gasket, Cylinder Head Cover1
59
Gasket, Cylinder Head (no
asbestos)
#Part NumberDescriptionQty
46.021000.00 Cylinder Head Cover (CPE)1
60
45.020001.02Breather Tube1
61
45.020100.00Bolt, Cylinder Head Cover1
62
2.08.039Bolt, D rain (M12×1.5×15)2
63
46.041000.00Camshaft (EPA)1
64
45.040013.00Lifter, Valve 2
65
45.040002.00Valve, Intake1
66
45.040006.00Valve, Exhaust1
67
46.040005.00Push Rod2
68
45.040015.00Retainer, Valve Spring (Down)2
69
45.040017.00Oil Seal, Valve2
70
45.040003.00Spring, Valve2
71
23.040010.00Bolt, Rocker Arm2
72
45.040001.00
73
45.040007.00
74
45.040008.00Rotator, Exhaust Valve1
75
46.040004.00Guide Plate Push Rod 1
76
46.040016.00Shaft, Rocker Arm1
77
46.040201.00Retainer, Rocker Arm1
78
46.040009.00Rocker Arm, Intake Valve 1
79
46.040018.00Rocker Arm, Exhaust Valve1
80
1.97.1.06 Washer 62
81
22.040012.00Screw, Valve Adjustment2
82
1.6177.1.06Flange Nut M62
83
21.040021.00Nut, Lock2
84
2.01.008Stud.Bolt (M6× M8×105)2
85
46.130002.20Gasket, Insulator (No Asbestos)1
86
45.130001.00Insulator, Carburetor1
87
46.130003.20Gasket, Carburetor (No Asbestos)1
88
46.133000.03Mixer1
89
46.130004.20
90
1. 6 17 7. 0 6Flange Nut M63
91
46.091100.04Base, Air Cleaner1
92
45. 0910 02.20Seal, Air Cleaner1
93
45. 0910 01.20Separator, Air Cleaner1
94
45.091003.20Element, Air Cleaner1
95
46.091200.04Cover, Air Cleaner1
96
1.5789.08 35Flange bolt M8×352
97
45.125100.00Star ter Motor Assembly1
98
45.125200.03Relay, Starter (three gear)1
99
1.93.05Spring Washer 52
100
1.16674.0516Flange bolt M5 ×162
101
45.110001.00Shaft, Governor Arm1
102
2.03.019Washer (ø8.2×ø17×0.8)1
103
2.11.0 06Oil Seal (ø7×ø14×5)1
104
45.110008.00Pin, Shaft1
105
45.110003.00Arm, Governor1
106
2.08.040Bolt, Governor Arm (M6 ×21)1
107
45.110006.00Rod Governor1
108
45.110005.00Spring, Throttle Return1
109
45.110007.00Spring, Governor1
1
110
46.080300.20Air Guide, Upper1
111
46 .133 025.0 0Negative Pressure Rubber Hose1
112
46.091000.04Air Cleaner Assembly1
113
46.061000.00Recoil Assembly1
114
46.130021.02Gas Tube (Mixer to switch)1
115
2.06.023Hose Clamp2
116
Retainer, Intake Valve Spring
(Up)
Retainer, Exhaust Valve Spring
(Up)
Gasket, Air Cleaner (No
Asbestos)
1
1
1
REV 71330-20130330 22
TROUBLESHOOTING
ProblemCauseSolution
Generator will not startNo fuelAdd fuel
Faulty spark plugReplace spark plug
Unit loaded during start upRemove load from unit
Low oil levelFill crankcase to the proper level
Place generator on a flat, level surface
Generator starts but runs roughlyChoke in the wrong positionAdjust choke
Spark plug wire looseAttach wire to spark plug
Generator shuts down during operationOut of fuelFill LP G cylinder
Low oil levelFill crankcase to the proper level. Place
generator on a flat, level surface
Generator cannot supply enough power or
overheating
No AC outputCable not properly connectedCheck all connections
Generator gallopsEngine governor defectiveContact the help line
Repeated circuit breaker trippingOverloadReview load and adjust. See “Power
Generator is overloadedReview load and adjust. See “Power
Management”
Insufficient ventilationCheck for air restriction. Move to a well
ventilated area
Connected device is defectiveReplace defective device
Champion Power Equipment (CPE) will register this
warranty upon receipt of your Warranty Registration Card
and a copy of your sales receipt from one of CPE’s retail
locations as proof of purchase.
Please submit your warranty registration and your proof
of purchase within ten (10) days of the date of purchase.
Repair/Replacement Warranty
CPE warrants to the original purchaser that the
mechanical and electrical components will be free of
defects in material and workmanship for a period of
one year (parts and labor) and two years (parts) from
the original date of purchase (90 days (parts and
labor) and 180 days (parts) for commercial & industrial
use). Transportation charges on product submitted
for repair or replacement under this warranty are the
sole responsibility of the purchaser. This warranty only
applies to the original purchaser and is not transferable.
Do Not Return The Unit To The Place Of Purchase
Contact CPE’s Technical Service and CPE will
troubleshoot any issue via phone or e-mail. If the
problem is not corrected by this method, CPE will, at its
option, authorize evaluation, repair or replacement of the
defective part or component at a CPE Service Center.
CPE will provide you with a case number for warranty
service. Please keep it for future reference. Repairs
or replacements without prior authorization, or at an
unauthorized repair facility, will not be covered by this
warranty.
Installation, Use and Maintenance Cont’d.
Normal maintenance such as spark plugs, air filters,
adjustments, fuel system cleaning and obstruction due
to buildup is not covered by this warranty.
Other Exclusions
This warranty excludes:
– Cosmetic defects such as paint, decals, etc.
– Wear items such as filter elements, o-rings, etc.
– Accessory parts such as starting batteries, and
storage covers.
– Failures due to acts of God and other force majeure
events beyond the manufacturer’s control.
– Problems caused by parts that are not original
Champion Power Equipment parts.
This warranty does not apply to generators used for
prime power in place of a utility.
Limits of Implied Warranty and Consequential Damage
Champion Power Equipment disclaims any obligation to
cover any loss of time, use of this product, freight, or
any incidental or consequential claim by anyone from
using this generator. THIS WARRANTY IS IN LIEU OF
ALL OTHER WARRANTIES, EXPRESS OR IMPLIED,
INCLUDING WARRANTIES OF MERCHANTABILITY OR
FITNESS FOR A PARTICULAR PURPOSE.
A unit provided as an exchange will be subject to the
warranty of the original unit. The length of the warranty
governing the exchanged unit will remain calculated by
reference to the purchase date of the original unit.
This warranty gives you certain legal rights which may
change from state to state. Your state may also have
other rights you may be entitled to that are not listed
within this warranty.
Contact Information
Warranty Exclusions
This warranty does not cover the following repairs and
equipment:
Normal Wear
Generators need periodic parts and service to perform well.
This warranty does not cover repair when normal use has
exhausted the life of a part or the equipment as a whole.
Installation, Use and Maintenance
This warranty will not apply to parts and/or labor if this
generator is deemed to have been misused, neglected,
involved in an accident, abused, loaded beyond the
generator’s limits, modified, installed improperly or
connected incorrectly to any electrical component.
Address
Champion Power Equipment, Inc.
Customer Service
10006 Santa Fe Springs Rd.
Santa Fe Springs, CA 90670
www.championpowerequipment.com
The United States Environment Protection Agency (U.S. EPA.) and the California Air Resources Board (CARB)
Emission Control System Warranty
Your Champion Power Equipment (CPE) engine complies with both the U.S. EPA and state of California Air
Resources Board (CARB) emission regulations.
YOUR WARRANTY RIGHTS AND OBLIGATIONS:
The US EPA, California Air Resources Board, and CPE are pleased to explain the Federal and California Emission
Control Systems Warranty on your 2013 small off-road engine and engine powered equipment. In California, new,
small off-road engines and new equipment that use small off-engines must be designed, built and equipped to meet
the State’s stringent anti smog standards. In the other states, new engines and equipment must be designed, built
and equipped, at the time of sale, to meet U.S. EPA regulations for small non-road engines. CPE warrants the
emission control system on your small off-road engine and equipment for the period of time listed below, provided
there has been no abuse, neglect, unapproved modification, or improper maintenance of your equipment.
Your emission control system may include parts such as the carburetor, fuel-injection system, the ignition system,
catalytic converter and fuel lines. Also included may be hoses, belts, connectors and other emission related
assemblies. Where a warrantable condition exits, CPE will repair your small off-road engine at no cost to you
including diagnosis, parts and labor. For engines less than or equal to 80cc, only the fuel tank and fuel line is
subject to the evaporative emission control warranty requirements of this section.
MANUFACTURER’S EMISSION CONTROL SYSTEM WARRANTY COVERAGE:
This emission control system is warranted for two years, subject to provisions set forth below. If, during the
warranty period, emission related part on your engine is defective in materials or workmanship, the part will be
repaired or replaced by CPE.
OWNER WARRANTY RESPONSIBILITIES:
As the small off-road engine owner, you are responsible for the performance of the required maintenance listed in
your Owner’s Manual. CPE recommends that you retain all your receipts covering maintenance on your small offroad engine, but CPE cannot deny warranty solely for the lack of receipts or for your failure to ensure the
performance of all scheduled maintenance.
As the small off-road engine owner, you should however be aware that CPE may deny you warranty coverage if
your small, off-road engine or a part has failed due to abuse, neglect, improper maintenance or unapproved
modifications.
You are responsible for presenting your small off-road engine to an Authorized CPE service outlet or alternate
service outlet as described in (3)(f.) below, CPE dealer or CPE, Santa Fe Springs, Ca. as soon as a problem exists.
The warranty repairs should be completed in a reasonable amount of time, not to exceed 30 days.
If you have any questions regarding your warranty rights and responsibilities, you should contact:
Champion Power Equipment, Inc.
Customer Service
10006 Santa Fe Springs Road
Santa Fe Springs, CA 90670
1-877-338-0999
tech@championpowerequipment.com
EMISSION CONTROL SYSTEM WARRANTY
The following are specific provisions relative to your Emission Control System (ECS) Warranty Coverage.
1. APPLICABILITY: This warranty shall apply to 1995 and later model year California small off-road engines (for
other states, 1997 and later model year engines). The ECS Warranty Period shall begin on the date the new engine
or equipment is delivered to its original, end-use purchaser, and shall continue for 24 consecutive months
thereafter.
2. GENERAL EMISSIONS WARRANTY COVERAGE
CPE warrants to the original, end-use purchaser of the new engine or equipment and to each subsequent
purchaser that each of its small off-road engines is:
a. Designed, built and equipped so as to conform to U.S. EPA emissions standards for spark-ignited
engines at or below 19 kilowatts and all applicable regulations adopted by the California Air Resources Board
and
b. Free from defects in materials and workmanship that cause the failure of a warranted part to be identical
in all material respects to the part as described in the engine manufacturer’s application for certification for a period
of two years.
3. THE WARRANTY ON EMISSION-RELATED PARTS WILL BE INTERPRETED AS FOLLOWS:
a. Any warranted part that is not scheduled for replacement as required maintenance in the Owners
Manual shall be warranted for the ECS Warranty Period. If any such part fails during the ECS Warranty Period, it
shall be repaired or replaced by CPE according to Subsection “d” below. Any such part repaired or replaced under
the ECS Warranty shall be warranted for any remainder of the ECS Warranty Period.
b. Any warranted, emissions-related part which is scheduled only for regular inspection as specified in the
Owners Manual shall be warranted for the ECS Warranty Period. A statement in such written instructions to the
effect of “repair or replace as necessary”, shall not reduce the ECS Warranty Period. Any such part repaired or
replaced under the ECS Warranty shall be warranted for the remainder of the ECS Warranty Period.
c. Any warranted, emissions-related part which is scheduled for replacement as required maintenance in
the Owner’s Manual shall be warranted for the period of time prior to the first scheduled replacement point for that
part. If the part fails prior to the first scheduled replacement, the part shall be repaired or replaced by CPE
according to Subsection “d” below. Any such emissions-related part repaired or replaced under the ECS Warranty,
shall be warranted for the remainder of the ECS Warranty Period prior to the first scheduled replacement point for
such emissions-related part.
d. Repair or replacement of any warranted, emissions-related part under this ECS Warranty shall be
performed at no charge to the owner at a CPE Authorized Service Outlet.
e. The owner shall not be charged for diagnostic labor which leads to the determination that a part covered
by the ECS Warranty is in fact defective, provided that such diagnostic work is performed at a CPE Authorized
Service Outlet.
f. CPE shall pay for covered emissions warranty repairs at non-authorized service outlets under the
following circumstances:
i. The service is required in a population center with a population over 100,000 according to U.S.
Census 2000 without a CPE Authorized Service Outlet AND
ii. The service is required more than 100 miles from a CPE Authorized Service Outlet. The 100 mile
limitation does not apply in the following states: Alaska, Arizona, Colorado, Hawaii, Idaho, Montana, Nebraska,
Nevada, New Mexico, Oregon, Texas, Utah and Wyoming.
g. CPE shall be liable for damages to other original engine components or approved modifications
proximately caused by a failure under warranty of an emission-related part covered by the ECS Warranty.
h. Throughout the ECS Warranty Period, CPE shall maintain a supply of warranted emission-related parts
sufficient to meet the expected demand for such emission-related parts.
i. Any CPE Authorized and approved emission-related replacement part may be used in the performance of
any ECS Warranty maintenance or repair and will be provided without charge to the owner. Such use shall not
reduce CPE’s warranty obligation.
j. Unapproved add-on or modified parts may not be used to modify or repair a CPE engine. Such use voids
this ECS Warranty and shall be sufficient grounds for disallowing an ECS Warranty claim. CPE shall not be liable
hereunder for failures of any warranted parts of a CPE engine caused by the use of such an unapproved add-on or
modified part.
EMISSION-RELATED PARTS INCLUDE THE FOLLOWING: (using those portions of the list applicable to the
engine)
Systems covered by this
warranty
Parts Description
Fuel Metering System
Fuel regulator, Carburetor and internal parts
Air Induction System
Air cleaner, Intake manifold
Ignition System
Spark plug and parts, Magneto ignition system
Exhaust System
Exhaust manifold, catalytic converter
Miscellaneous Parts
Tubing, Fittings, Seals, Gaskets, and Clamps associated with these listed
systems.
Evaporative Emissions
Fuel Tank, Fuel Cap, Fuel Line, Fuel Line Fittings, Clamps, Pressure
Relief Valves, Control Valves, Control Solenoids, Electronic Controls,
Vacuum Control Diaphragms, Control Cables, Control Linkages, Purge
Valves, Vapor Hoses, Liquid/Vapor Separator, Carbon Canister, Canister
Mounting Brackets, Carburetor Purge Port Connector
TO OBTAIN WARRANTY SERVICE:
You must take your CPE engine or the product on which it is installed, along with your warranty registration card or
other proof of original purchase date, at your expense, to any Champion Power Equipment dealer who is
authorized by Champion Power Equipment, Inc. to sell and service that CPE product during his normal business
hours. Alternate service locations defined in Section (3)(f.) above must be approved by CPE prior to service. Claims
for repair or adjustment found to be caused solely by defects in material or workmanship will not be denied because
the engine was not properly maintained and used.
If you have any questions regarding your warranty rights and responsibilities, or to obtain warranty
service, please write or call Customer Service at Champion Power Equipment, Inc.
Champion Power Equipment, Inc.
10006 Santa Fe Springs Road
Santa Fe Springs, CA 90670
1-877-338-0999
Attn.: Customer Service
tech@championpowerequipment.com