SAVE THESE INSTRUCTIONS. This manual contains important safety precautions which should be read and understood before operating the product. Failure
to do so could result in serious injury. This manual should remain with the product.
Specifications, descriptions and illustrations in this manual are as accurate as known at the time of publication, but are subject to change without notice.
Covered by one or more of the following U.S. Patent Numbers: 10,598,101, 9,435,273, D710,802, and other U.S. and foreign patents pending.
This product is rated in accordance with PGMA (Portable Generator Manufacturers’ Association) standard ANSI/PGMA G300 (Safety and Performance of
Portable Generators).
RE V 20210127Champion Power Equipment, Inc., Santa Fe Springs, CA USA
Congratulations on your purchase of a Champion Power
Equipment (CPE) product. CPE designs, builds, and supports
all of our products to strict specifications and guidelines. With
proper product knowledge, safe use, and regular maintenance,
this product should bring years of satisfying service.
Every effort has been made to ensure the accuracy and
completeness of the information in this manual at the time
of publication, and we reserve the right to change, alter and/
or improve the product and this document at any time without
prior notice.
CPE highly values how our products are designed,
manufactured, operated, and serviced as well as providing
safety to the operator and those around the generator.
Therefore, it is IMPORTANT to review this product manual
and other product materials thoroughly and be fully aware
and knowledgeable of the assembly, operation, dangers
and maintenance of the product before use. Fully familiarize
yourself, and make sure others who plan on operating the
product fully familiarize themselves too, with the proper safety
and operation procedures before each use. Please always
exercise common sense and always err on the side of caution
when operating the product to ensure no accident, property
damage, or injury occurs. We want you to continue to use and
be satisfied with your CPE product for years to come.
When contacting CPE about parts and/or service, you will
need to supply the complete model and serial numbers of your
product. Transcribe the information found on your product’s
nameplate label to the table below
SAFETY DEFINITIONS
The purpose of safety symbols is to attract your attention to
possible dangers. The safety symbols, and their explanations,
deserve your careful attention and understanding. The safety
warnings do not by themselves eliminate any danger. The
instructions or warnings they give are not substitutes for proper
accident prevention measures.
DANGER
DANGER indicates a hazardous situation which,if not
avoided, will result in death or serious injury.
WARNING
WARNING indicates a hazardous situation which, if not
avoided, could result in death or serious injury.
CAUTION
CAUTION indicates a hazardous situation which, if not
avoided, could result in minor or moderate injury.
NOTICE
NOTICE indicates information considered important, but
not hazard-related (e.g., messages relating to property
damage).
CPE TECHNICAL SUPPORT TEAM
1-877-338-0999
MODEL NUMBER
100592
SERIAL NUMBER
DATE OF PURCHASE
PURCHASE LOCATION
3
100592 - 6250W DUAL FUEL GENERATOR
IMPORTANT SAFETY INSTRUCTIONS
IMPORTANT SAFETY INSTRUCTIONS
WARNING
Cancer and Reproductive Harm – www.P65Warnings.ca.gov
DANGER
Generator exhaust contains carbon monoxide, a colorless,
odorless, poisonous gas. Breathing carbon monoxide will
cause nausea, dizziness, fainting or death. If you start to
feel dizzy or weak, get to fresh air immediately.
OPERATE GENERATOR OUTDOORS ONLY IN A WELL
VENTILATED AREA AND POINT EXHAUST AWAY.
DO NOT operate the generator inside any building, including
garages, basements, crawlspaces and sheds, enclosure or
compartment, including the generator compartment of a
recreational vehicle.
DO NOT allow exhaust fumes to enter a confined area
through windows, doors, vents or other openings.
DANGER
Using a generator indoors CAN KILL YOU IN MINUTES.
Generator exhaust contains carbon monoxide. This is a
poison you cannot see or smell.
NEVER use inside a home or garage, EVEN IF doors and
windows are open.
ONLY use OUTSIDE and far away from windows, doors,
and vents.
DANGER
Operate equipment with guards in place.
Rotating parts can entangle hands, feet, hair, clothing and/
or accessories. Traumatic amputation or severe laceration
can result.
Keep hands and feet away from rotating parts.
Tie up long hair and remove jewelry.
DO NOT wear loose-fitting clothing, dangling drawstrings or
items that could become caught.
DANGER
Generator produces powerful voltage.
DO NOT touch bare wires or receptacles.
DO NOT use electrical cords that are worn, damaged or
frayed. Use only Champion electrical cords for proper
application.
DO NOT operate generator in wet weather.
DO NOT allow children or unqualified persons to operate or
service the generator.
Use a ground fault circuit interrupter (GFCI) in damp areas
and areas containing conductive material such as metal
decking.
Connection to your home’s electrical system requires a
listed 30A transfer switch installed by a licensed electrician
and approved by the local authority having jurisdiction. The
connection must isolate the generator from the utility power
and must comply with all applicable laws and electrical
codes.
Install battery-operated carbon monoxide alarms or plug-in
carbon monoxide alarms with battery back-up according to
the manufacturer’s instructions.
WARNING
Although the generator contains a spark arrester, maintain
a minimum distance of 5 ft. (1.5 m) from dry vegetation to
prevent fires.
WARNING
Do not use generator for medical and life support uses.
In case of emergency, call 911 immediately.
NEVER use this product to power life support devices or life
support appliances.
NEVER use this product to power medical devices or
medical appliances.
Inform your electricity provider immediately if you or anyone
in your household depends on electrical equipment to live.
Inform your electrical provider immediately if a loss of power
would cause you or anyone in your household to experience
a medical emergency.
4
100592 - 6250W DUAL FUEL GENERATOR
IMPORTANT SAFETY INSTRUCTIONS
WARNING
Spark from removed spark plug wire can result in fire or
electrical shock.
When servicing the generator:
Disconnect the spark plug wire and place it where it cannot
contact the plug or any other metal object.
DO NOT check for spark with the plug removed.
Use only approved spark plug testers.
WARNING
Running engines produce heat. Severe burns can occur on
contact. Combustible material can catch fire on contact.
DO NOT touch hot surfaces.
Avoid contact with hot exhaust gases.
Allow equipment to cool before touching.
Maintain at least 3 ft. (91.4 cm) of clearance on all sides to
ensure adequate cooling.
Maintain at least 5 ft. (1.5 m) of clearance from combustible
materials.
CAUTION
Start the generator and allow the engine to stabilize before
connecting electrical loads.
Connect electrical equipment in the off position, and then
turn them on for operation.
Turn electrical equipment off and disconnect before
stopping the generator.
CAUTION
Improper treatment or use of the generator can damage it,
shorten its life or void the warranty.
Use the generator only for intended uses.
Operate only on level surfaces.
DO NOT expose generator to excessive moisture, dust,
or dirt.
DO NOT allow any material to block the cooling slots.
If connected devices overheat, turn them off and disconnect
them from the generator.
DO NOT use the generator if:
– Electrical output is lost
WARNING
Rapid retraction of the starter cord will pull hand and arm
towards the engine faster than you can let go. Unintentional
startup can result in entanglement, traumatic amputation or
laceration. Broken bones, fractures, bruises or sprains could
result.
When starting engine, pull the starter cord slowly until
resistance is felt and then pull rapidly to avoid kickback.
DO NOT start or stop the engine with electrical devices
plugged in and turned on.
CAUTION
Exceeding the generator’s running capacity can damage the
generator and/or electrical devices connected to it.
DO NOT overload the generator.
DO NOT tamper with the governed speed.
DO NOT modify the generator in any way.
– Equipment sparks, smokes or emits flames
– Equipment vibrates excessively
WARNING
Tampering with CO Shield™ could result in a hazardous
condition. Removing the CO Shield module will not allow the
generator to start.
5
100592 - 6250W DUAL FUEL GENERATOR
IMPORTANT SAFETY INSTRUCTIONS
Fuel Safety
DANGER
GASOLINE, GASOLINE VAPORS AND PROPANE (LPG) ARE
HIGHLY FLAMMABLE AND EXPLOSIVE.
Fire or explosion can cause severe burns or death.
Gasoline and gasoline vapors:
– Gasoline is highly flammable and explosive.
– Gasoline can cause a fire or explosion if ignited.
– Gasoline is a liquid fuel but it’s vapors can ignite.
– Gasoline is a skin irritant and needs to be cleaned up
immediately if spilled on skin or clothes.
– Gasoline has a distinctive odor, this will help detect potential
leaks quickly.
– In any petroleum gas fire, flames should not be extinguished
unless by doing so the fuel supply valve can be turned OFF.
This is because if a fire is extinguished and a supply of
fuel is not turned OFF, then an explosion hazard could be
created.
– Gasoline expands or contracts with ambient temperatures.
Never fill the gasoline tank to full capacity, as gasoline
needs room to expand if temperatures rise.
LPG:
– LPG is highly flammable and explosive.
– LPG is under pressure and can cause a fire or explosion if
ignited.
– LPG is heavier than air and can settle in low places while
dissipating.
– LPG has a distinctive odor added to help detect potential
leaks quickly.
– In any petroleum gas fire, flames should not be extinguished
unless the fuel supply valve is turned OFF. This is because if
a fire is extinguished and a supply of fuel is not turned OFF,
then an explosion hazard could be created.
– When exchanging LPG cylinders, be sure the cylinder valve
is of the same type.
– Always keep the LPG cylinder in an upright position.
– LPG will burn skin if it comes in contact with it. Keep any
and all LPG away from skin at all times.
When adding or removing gasoline:
DO NOT light or smoke cigarettes.
Turn the generator off and let it cool for at least two minutes
before removing the gasoline cap. Loosen the cap slowly to
relieve pressure in the tank.
Only fill or drain gasoline outdoors in a well-ventilated area.
DO NOT pump gasoline directly into the generator at the gas
station. Use an approved container to transfer the fuel to the
generator.
DO NOT overfill the gasoline tank.
Always keep gasoline away from sparks, open flames, pilot
lights, heat and other sources of ignition.
When starting the generator:
DO NOT attempt to start a damaged generator.
Make certain that the gasoline cap, air filter, spark plug, fuel
lines and exhaust system are properly in place.
Allow spilled gasoline to evaporate fully before attempting to
start the engine.
Make certain that the generator is resting firmly on level
ground.
When operating the generator:
DO NOT move or tip the generator during operation.
DO NOT tip the generator or allow fuel or oil to spill.
When transporting or servicing the generator:
Make certain that the fuel valve is in the OFF position and the
gasoline tank is empty.
For LPG compatible models, be sure that the LPG cylinder is
disconnected and stored securely away from the generator.
Disconnect the spark plug wire.
When storing the generator:
Store away from sparks, open flames, pilot lights, heat and
other sources of ignition.
Do not store generator, gasoline or LPG cylinders near furnaces,
water heaters, or any other appliances that produce heat or
have automatic ignitions.
WARNING
Never use a gasoline container, gasoline tank, LPG
connector hose, LPG cylinder or any other fuel item that is
broken, cut, torn or damaged.
6
100592 - 6250W DUAL FUEL GENERATOR
PELIGRO
El uso de un generador en
interiores PUEDE MATARLO EN MINUTOS. El escape del
generador contiene monóxido de
carbono. Éste es un veneno que no
se puede ver ni oler.
•
NUNCA lo use dentro del hogar ni
el garaje, INCLUSO SI las puertas
y ventanas están abiertas.
•
Úselo SÓLO a la INTEMPERIE
lejos de ventanas, puertas, y
orificios de ventilación.
DANGER
Utiliser un générateur à l’intérieur
PEUT VOUS TUER EN QUELQUES
MINUTES. L’échappement du
générateur contient du monoxyde de
carbone. Il s’agit d’un poison que vous
ne pouvez ni voir ni sentir.
•
Ne l’utilisez JAMAIS dans la
maison ou le garage MÊME SI les
portes et les fenêtres sont ouvertes.
•
Utilisez-le UNIQUEMENT À
L’E XTÉ RI EUR , loin des fenêtres,
portes et trappes de ventilation.
NEVER use inside a
home or garage,
EVEN IF doors and
windows are open.
ONLY use OUT SIDE
and far away from
windows, doors,
and vents.
DANGER
Using a generator indoors CAN KILL
YOU IN MINUTES. Generator exhaust
contains carbon monoxide. This is a
poison you cannot see or smell.
Move generator to an open, outdoor area. Point exhaust away. Don’t run gener ators
in enclosed areas (e.g. not in house or garage).
Mover el generador a un área abierta a la intemperie. Apunt e el escape alejado. No corra los
generadores en áreas cerradas (ej. no en una casa o garaje).
Déplacer le générateur vers un espace extérieur
en plein air. Garder l’échappement loin. Ne pas
faire fonctionner les générateurs dans un espace
clos (ex., pas dans une maison ou un garage).
ACTION LABEL
ETIQUETA DE ACCIÓN
ÉTIQUETTE D'ACTION
EXHAUST
EL ESCAPE
L’ECHAPPEMENT
POI NT AWAY
DIRIJA ALEJADO
DIRIGER LOIN
Move to fresh air and get medical
help if sick, dizzy or weak.
Mueva al aire fresco y obtenga
asistencia medica si está
enfermo, mareado, o débil.
Aller à l'air frais et obtenir de
l'aide médicale si malade,
étourdi ou faible.
UNLEADED FUEL ONLY. Minimum octane rating
of 87. Maximum 10% e thanol.
GASOLINA REGULAR SOLAMENTE. 87 octanos
como mínimo . Máximo de etanol d e 10%.
ESSENCE SANS PLOMB SEULEMENT. Indice
d’octane mi nimal de 87. Maximum 10 % d'étha nol.
1032-L-OP-B
WARNING
DO NOT TOUCH!
Exhaust gases, mu ffler
and engine components
are extremely HOT and
cause burns.
Operation of this equip ment may create sparks tha t can start
fires around dry veget ation. A spark arrest or may be
required. The operator should contact local fire agencies for
laws and regulations rela ting to fire prevention req uirements.
If installed, clean ever y 100 hours or every seas on.
ADVERTENCIA
¡NO TOCAR! Los gases de
escape, el silenciador y lo s
compnonentes del motor están
extremadamente CA LIENTES y
causan quemaduras.
La operación de este eq uipo puede producir chisp as que pueden provocar
incendios alrededor de la vegetación seca. Un supresor de chispas puede que
sea necesario. El operador debe comunicarse con las agencias locales de
bomberos para las leyes y reglamentos relativos a los requisitos de prevención
de incendios. Si está ins talado, limpie cada 100 hor as o cada temporada.
AVERTISSEMENT
NE PAS TOUCHER! Les gaz
d’échappement, le silencieux
et les pièces du moteur sont
extrêmement CHAU DS et
peuvent causer des brûlures.
Cet équipement peut cré er des étincelles et provo quer un incendie dans la
végétation sèche. Un pa re-étincelles peut ê tre requis. L’utilisateur doit
communiquer avec le servi ce d’incendie local pour con naître les lois et
les règlements en matièr e de prévention des incendi es. Si elle est
installée, nettoyez l a génératrice toutes les 100 heures ou chaque saison.
1035-L-SF-C
IMPORTANT SAFETY INSTRUCTIONS
Safety Labels
These labels warn you of potential hazards that can cause serious injury. Read them carefully.
If a label comes off or becomes hard to read, contact Technical Support Team for possible replacement.
A
D
B
C
Top
Back
LABELDESCRIPTION
A
Safety Symbols/
CO Danger
CO Shield™
Action – automatic
B
shutoff
*See CO Shield
section
C
D
Fuel
Hot Surface
7
100592 - 6250W DUAL FUEL GENERATOR
IMPORTANT SAFETY INSTRUCTIONS
Safety Symbols
Some of the following symbols may be used on this product. Please study them and learn their meaning. Proper interpretation of
these symbols will allow you to more safely operate the product.
SYMBOLMEANING
Read Operator’s Manual. To reduce the risk of injury, user must read and understand operator’s
manual before using this product.
Clearance. Keep all objects at least 5 feet (1.5m) from generator. Heat from the muffler and exhaust
gas can ignite combustible objects.
Ground. Consult with local electrician to determine grounding requirements before operation.
Electric Shock. Failure to use in dry conditions and to observe safe practices can result in electric
shock. Improper connections to a building can allow current to backfeed into utility lines, creating an
electrocution hazard. A transfer switch must be used when connecting to a building.
Fire/Explosion. Fuel and its vapors are extremely flammable and explosive. Fire or explosion
can cause severe burns or death. Keep generator at least 5 feet (1.5m) from all objects to prevent
combustion.
Hot Surface. To reduce the risk of injury or damage, avoid contact with any hot surface.
Open Flame Alert. Fuel and its vapors are extremely flammable and explosive. Keep fuel away from
smoking, open flames, sparks, pilot lights, heat, and other ignition sources.
Wet Conditions Alert. Do not expose to rain or use in damp locations.
8
100592 - 6250W DUAL FUEL GENERATOR
IMPORTANT SAFETY INSTRUCTIONS
Operation Symbols
Some of the following symbols may be used on this product. Please study them and learn their meaning. Proper interpretation of
these symbols will allow you to more safely operate the product.
SYMBOLMEANING
ON
STOP or OFF
High CO Warning. Move generator to
an open, outdoor area. Move to fresh
air and get medical help if sick, dizzy
or weak.
System Fault. Electrical issue,
tampering, end of life.
Locking Receptacle
Neutral Bonded to Frame. Neutral
circuit IS electrically connected to the
frame/ground of the generator.
Choke
SYMBOLMEANING
Ground Terminal
Propane Valve ON/OFF
Fuel/Gasoline Valve ON/OFF
Propane Operation
Gasoline Operation
Propane Inlet
Propane Fuel Source. Turn off fuel
source when generator is not in use.
Run
9
100592 - 6250W DUAL FUEL GENERATOR
1604-L-OP-A
10W-30
14
567813
2A
2B
3A
2A
2B
3B
b
c
+
+
+
+
IMPORTANT SAFETY INSTRUCTIONS
Quickstart Label Symbols
Some of the following symbols may be used on this product. Please study them and learn their meaning. Proper interpretation of
these symbols will allow you to more safely operate the product.
Starting the Engine
DANGER
Move generator outside and far away from windows,
doors and intake ventilation covers.
1. Check oil level.
Recommended oil is 10W-30.
2. Add fuel.
2a. If operating on gasoline, check gasoline level.
When adding gasoline, use a minimum octane rating of
87 and an ethanol content of 10% or less by volume.
2b. If operating on propane, connect propane tank.
Open valve on propane tank.
3. Fuel Selector
3a. Slide Fuel Selector to the left for gasoline operation.
Then turn the fuel valve to the “ON” position.
3b. Slide Fuel Selector to the right for LPG operation. Then
turn the fuel valve to the “ON” position.
4. Press engine switch to the “ON” position.
Stopping the Engine
1. Turn off and unplug all connected electrical loads.
2. Fuel Valve
2a. If operating on gasoline, turn the fuel valve to the
“OFF” position.
2b. If operating on LPG, turn the fuel valve to the “OFF”
position on the generator and on the tank.
3. Press the engine switch to the “OFF” position.
5. Move choke lever to “CHOKE” position.
6. Pull the recoil starter.
7. Move the choke lever to “RUN” position.
8. Plug in desired device.
10
100592 - 6250W DUAL FUEL GENERATOR
CONTROLS AND FEATURES
CONTROLS AND FEATURES
Read this operator’s manual before operating your generator. Familiarize yourself with the location and function of the controls and
features. Save this manual for future reference.
Generator
1
2
3
4
5
1. Gasoline Tank – 6 gal. (22.9 L)
2. Choke – Used to start the engine.
3. Air Filter – Protects the engine by filtering dust and debris
from the intake air.
4. Never Flat Wheels – 8 in. (20.3 cm)
8
7
6
9
7. Folding Handle – Used to move unit by lifting and rolling
on wheels. Do not use to lift or carry the unit.
8. Control Panel – See “Control Panel” section.
9. Ground Terminal – Consult an electrician for local
grounding regulations.
5. Recoil Starter – Used to manually start the engine.
6. Oil Fill Cap/Dipstick – Used to check and fill oil level.
11
100592 - 6250W DUAL FUEL GENERATOR
Control Panel
CONTROLS AND FEATURES
1
2
1. Fuel Selector – Used to select and turn on gasoline or
propane (LPG) fuel source.
2. LPG Inlet – Used to connect LPG fuel source to generator.
3. Engine Switch – Used to put in START mode or STOP the
generator. When operating by propane, this switch will NOT
stop the engine.
4. Intelligauge – Three mode digital meter for displaying
total run time, voltage and hertz.
5. CO Shield red shutoff LED
3
5
A
A
Y
B
C
B
RECEPTACLES
120/240V AC, 30A Locking (NEMA L14-30R)
May be used to supply electrical power for
operation of 120/240 Volt AC, 30 Amp, single
phase, 60 Hz electrical loads.
(4×) 120V AC, 20A GFCI (NEMA 5-20R)
May be used to supply electrical power for
operation of 120 Volt AC, 20 Amp, single
phase, 60 Hz electrical loads.
4
6
7
8
6. CO Shield yellow service LED
The CO Shield technology monitors for accumulation of
poisonous carbon monoxide (CO) gas produced by engine
exhaust when the generator is running. If CO Shield detects
elevated levels of CO gas, it automatically shuts off the engine.
* *See CO Shield section for more information
7. Circuit Breakers (Push Reset) – Protects the generator
against electrical overloads.
8. Circuit Breakers (Flip Reset) – Protects the generator
against electrical overloads.
12
100592 - 6250W DUAL FUEL GENERATOR
Intelligauge
Three mode digital meter for displaying voltage, hertz, and total
run time.
Push SELECT button on right side of gauge to display different
modes.
MODEDESCRIPTION
CONTROLS AND FEATURES
V
Hz
H
Output voltage of the generator.
Voltage (V)
Frequency (Hz)
Total Run Time(H)
Example: 120 volts
Example: 60.0 hertz
Example: 80 hours
V
Hz
120
H
Output frequency in hertz.
V
Hz
60.0
H
Total run time of the generator since first operation.
V
Hz
80.0
H
13
Loading...