Congratulations on your purchase of a Champion Power
Equipment (CPE) product. CPE designs, builds, and supports
all of our products to strict specifications and guidelines. With
proper product knowledge, safe use, and regular maintenance,
this product should bring years of satisfying service.
Every effort has been made to ensure the accuracy and
completeness of the information in this manual at the time
of publication, and we reserve the right to change, alter and/
or improve the product and this document at any time without
prior notice.
CPE highly values how our products are designed,
manufactured, operated, and serviced as well as providing
safety to the operator and those around the generator.
Therefore, it is IMPORTANT to review this product manual
and other product materials thoroughly and be fully aware
and knowledgeable of the assembly, operation, dangers
and maintenance of the product before use. Fully familiarize
yourself, and make sure others who plan on operating the
product fully familiarize themselves too, with the proper safety
and operation procedures before each use. Please always
exercise common sense and always err on the side of caution
when operating the product to ensure no accident, property
damage, or injury occurs. We want you to continue to use and
be satisfied with your CPE product for years to come.
When contacting CPE about parts and/or service, you will
need to supply the complete model and serial numbers of your
product. Transcribe the information found on your product’s
nameplate label to the table below.
SAFETY DEFINITIONS
The purpose of safety symbols is to attract your attention to
possible dangers. The safety symbols, and their explanations,
deserve your careful attention and understanding. The safety
warnings do not by themselves eliminate any danger. The
instructions or warnings they give are not substitutes for proper
accident prevention measures.
! DANGER
DANGER indicates a hazardous situation which,if not
avoided, will result in death or serious injury.
! WARNING
WARNING indicates a hazardous situation which, if not
avoided, could result in death or serious injury.
! CAUTION
CAUTION indicates a hazardous situation which, if not
avoided, could result in minor or moderate injury.
"
NOTICE
NOTICE indicates information considered important, but
not hazard-related (e.g., messages relating to property
damage).
CPE TECHNICAL SUPPORT TEAM
1-8 77-3 3 8-0999
MODEL NUMBER
100 565
SERIAL NUMBER
DATE OF PURCHASE
PURCHASE LOCATION
3
100565 - 2000W PORTABLE INVERTER GENERATOR
IMPORTANT SAFETY INSTRUCTIONS
IMPORTANT SAFETY INSTRUCTIONS
! WARNING
Cancer and Reproductive Harm – www.P65Warnings.ca.gov
! DANGER
Generator exhaust contains carbon monoxide, a colorless,
odorless, poisonous gas. Breathing carbon monoxide will
cause nausea, dizziness, fainting or death. If you start to
feel dizzy or weak, get to fresh air immediately.
OPERATE GENERATOR OUTDOORS ONLY IN A WELL
VENTILATED AREA AND POINT EXHAUST AWAY.
DO NOT operate the generator inside any building, including
garages, basements, crawlspaces and sheds, enclosure or
compartment, including the generator compartment of a
recreational vehicle.
DO NOT allow exhaust fumes to enter a confined area
through windows, doors, vents or other openings.
! DANGER
Operate equipment with guards in place.
Rotating parts can entangle hands, feet, hair, clothing and/
or accessories. Traumatic amputation or severe laceration
can result.
Keep hands and feet away from rotating parts.
Tie up long hair and remove jewelry.
DO NOT wear loose-fitting clothing, dangling drawstrings or
items that could become caught.
! DANGER
Generator produces powerful voltage.
DO NOT touch bare wires or receptacles.
DO NOT use electrical cords that are worn, damaged or
frayed. Use only Champion electrical cords for proper
application.
DO NOT operate generator in wet weather.
! DANGER
Using a generator indoors CAN KILL YOU IN MINUTES.
Generator exhaust contains carbon monoxide. This is a
poison you cannot see or smell.
NEVER use inside a home or garage, EVEN IF doors and
windows are open.
ONLY use OUTSIDE and far away from windows, doors,
and vents.
Install battery-operated carbon monoxide alarms or plug-in
carbon monoxide alarms with battery back-up according to
the manufacturer’s instructions.
! WARNING
DO NOT allow children or unqualified persons to operate or
service the generator.
Use a ground fault circuit interrupter (GFCI) in damp areas
and areas containing conductive material such as metal
decking.
Connection to your home’s electrical system requires a
listed 30A transfer switch installed by a licensed electrician
and approved by the local authority having jurisdiction. The
connection must isolate the generator from the utility power
and must comply with all applicable laws and electrical
codes.
! WARNING
Do not use generator for medical and life support uses.
In case of emergency, call 911 immediately.
NEVER use this product to power life support devices or life
support appliances.
NEVER use this product to power medical devices or
medical appliances.
Although the generator contains a spark arrester, maintain
a minimum distance of 5 ft. (1.5m) from dry vegetation to
prevent fires.
Inform your electricity provider immediately if you or anyone
in your household depends on electrical equipment to live.
Inform your electrical provider immediately if a loss of power
would cause you or anyone in your household to experience
a medical emergency.
4
100565 - 2000W PORTABLE INVERTER GENERATOR
IMPORTANT SAFETY INSTRUCTIONS
! WARNING
Spark from removed spark plug wire can result in fire or
electrical shock.
When servicing the generator:
Disconnect the spark plug wire and place it where it cannot
contact the plug or any other metal object.
DO NOT check for spark with the plug removed.
Use only approved spark plug testers.
! WARNING
Running engines produce heat. Severe burns can occur on
contact. Combustible material can catch fire on contact.
DO NOT touch hot surfaces.
Avoid contact with hot exhaust gases.
Allow equipment to cool before touching.
Maintain at least 3 ft. (91.4 cm) of clearance on all sides to
ensure adequate cooling.
Maintain at least 5 ft. (1.5 m) of clearance from combustible
materials.
! CAUTION
Start the generator and allow the engine to stabilize before
connecting electrical loads.
Connect electrical equipment in the off position, and then
turn them on for operation.
Turn electrical equipment off and disconnect before
stopping the generator.
! CAUTION
Improper treatment or use of the generator can damage it,
shorten its life or void the warranty.
Use the generator only for intended uses.
Operate only on level surfaces.
DO NOT expose generator to excessive moisture, dust,
or dirt.
DO NOT allow any material to block the cooling slots.
If connected devices overheat, turn them off and disconnect
them from the generator.
DO NOT use the generator if:
– Electrical output is lost
! WARNING
Rapid retraction of the starter cord will pull hand and arm
towards the engine faster than you can let go. Unintentional
startup can result in entanglement, traumatic amputation or
laceration. Broken bones, fractures, bruises or sprains could
result.
When starting engine, pull the starter cord slowly until
resistance is felt and then pull rapidly to avoid kickback.
DO NOT start or stop the engine with electrical devices
plugged in and turned on.
! CAUTION
Exceeding the generator’s running capacity can damage the
generator and/or electrical devices connected to it.
DO NOT overload the generator.
DO NOT tamper with the governed speed.
DO NOT modify the generator in any way.
– Equipment sparks, smokes or emits flames
– Equipment vibrates excessively
5
100565 - 2000W PORTABLE INVERTER GENERATOR
IMPORTANT SAFETY INSTRUCTIONS
Fuel Safety
! DANGER
GASOLINE AND GASOLINE VAPORS ARE HIGHLY
FLAMMABLE AND EXPLOSIVE.
Fire or explosion can cause severe burns or death.
Gasoline and gasoline vapors:
– Gasoline is highly flammable and explosive.
– Gasoline can cause a fire or explosion if ignited.
– Gasoline is a liquid fuel but it’s vapors can ignite.
– Gasoline is a skin irritant and needs to be cleaned up
immediately if spilled on skin or clothes.
– Gasoline has a distinctive odor, this will help detect potential
leaks quickly.
– Gasoline expands or contracts with ambient temperatures.
Never fill the gasoline tank to full capacity, as gasoline
needs room to expand when temperatures rise.
– In the case of any petroleum gasoline fire, flames should
never be extinguished unless the fuel supply valve can be
turned OFF. By not doing so, if a fire is extinguished and the
supply of fuel is not turned OFF, an explosion hazard could
be created.
Make certain that the generator is resting firmly on level
ground.
When operating the generator:
DO NOT move or tip the generator during operation.
DO NOT tip the generator or allow fuel or oil to spill.
When transporting or servicing the generator:
Make certain that the fuel valve is in the OFF position and the
gasoline tank is empty.
Disconnect the spark plug wire.
When storing the generator:
Store away from sparks, open flames, pilot lights, heat and
other sources of ignition.
Do not store generator or gasoline near furnaces, water heaters,
or any other appliances that produce heat or have automatic
ignitions.
! WARNING
Never use a gasoline container, gasoline tank, or any other
fuel item that is broken, cut, torn or damaged.
When adding or removing gasoline:
DO NOT light or smoke cigarettes.
Always turn the generator off and let cool for a minimum of two
minutes before removing the gasoline cap. Afterwards, loosen
gasoline cap to relieve pressure from the gasoline tank.
Only fill or drain gasoline outdoors in a well-ventilated area.
DO NOT pump gasoline directly into the generator at the gas
station. Always use an approved fuel container to transfer the gasoline to the generator.
DO NOT overfill the gasoline tank.
Always keep gasoline away from sparks, open flames, pilot
lights, heat and other sources of ignition.
When starting the generator:
DO NOT attempt to start a damaged generator.
Always make certain that the gasoline cap, air filter, spark
plug, fuel lines and exhaust system are properly secured, connectedand in place.
Always allow spilled gasoline to evaporate fully before
attempting to start the engine.
ElusodeungeneradoreninterioresPUEDEMATARLOENMINUTOS.Elescapedelgeneradorcontienemonóxidodecarbono.Ésteesunvenenoquenosepuedevernioler.NUNCAlousedentrodelhogarnielgaraje,INCLUSOSI las puertas y ventanas
estánabiertas.ÚseloSÓLOa la INTEMPERIElejosdeventanas,puertas,yorificiosdeventilación.
! PELIGRO
ONLYuseOUTSIDEand far away from windows, doors, and vents.
NEVERuseinsidea home or garage, EVENIF doors and windowsareopen.
Some of the following symbols may be used on this product. Please study them and learn their meaning. Proper interpretation of
these symbols will allow you to more safely operate the product.
SYMBOLMEANING
Read Operator’s Manual. To reduce the risk of injury, user must read and understand operator’s
manual before using this product.
Clearance. Keep all objects at least 5 feet from this machine. Heat from the muffler and exhaust
gas can ignite combustible objects.
Ground. Consult with local electrician to determine grounding requirements before operation.
Electric Shock. Failure to use in dry conditions and to observe safe practices can result in electric
shock. Improper connections to a building can allow current to backfeed into utility lines, creating an
electrocution hazard. A transfer switch must be used when connecting to a building.
Fire/Explosion. Fuel and its vapors are extremely flammable and explosive. Fire or explosion
can cause severe burns or death. Keep generator at least 5 ft (1.5m) from all objects to prevent
combustion.
Hot Surface. To reduce the risk of injury or damage, avoid contact with any hot surface.
Open Flame Alert. Fuel and its vapors are extremely flammable and explosive. Keep fuel away from
smoking, open flames, sparks, pilot lights, heat, and other ignition sources.
Wet Conditions Alert. Do not expose to rain or use in damp locations.
8
100565 - 2000W PORTABLE INVERTER GENERATOR
IMPORTANT SAFETY INSTRUCTIONS
Operation Symbols
Some of the following symbols may be used on this product. Please study them and learn their meaning. Proper interpretation of
these symbols will allow you to more safely operate the product.
SYMBOLMEANING
Engine START
Engine RUN
Engine STOP
Run out of fuel. Stopping the
generator.
Choke
Run
Overload Reset Switch
SYMBOLMEANING
Low Oil Level Indicator
Receptacle Status
Economy Mode Switch
ECO
Circuit Breaker Reset: Push
Ground Terminal
Neutral Floating. Neutral circuit IS
NOT electrically connected to the
frame/ground of the generator.
Parallel Connection(s)
Overload
12V Direct Curr ent
9
100565 - 2000W PORTABLE INVERTER GENERATOR
1311-L-OP-B
7123456
12
!
10W-30
!
IMPORTANT SAFETY INSTRUCTIONS
Quick Start Label Symbols
Some of the following symbols may be used on this product. Please study them and learn their meaning. Proper interpretation of
these symbols will allow you to more safely operate the product.
Starting the Engine
1. Check oil level.
Recommended oil is 10W-30.
2. Check gasoline level.
When adding gasoline, use a minimum octane rating of 85
and an ethanol content of 10% or less by volume.
3. Turn th e fuel c ap vent l ever to th e “ON” position.
4. Tur n E Z Star t dial clock wise to the full “CHOKE” position.
5. Pull the starter cord
6. Move the EZ Start dial to the “RUN” position.
7. Plug in desired device.
Stopping the Engine
1. Tur n of f a nd unp lug all electr ica l loads .
2. Tur n t he E Z Star t dial c ount erclock wise to the “STOP”
position.
10
100565 - 2000W PORTABLE INVERTER GENERATOR
CONTROLS AND FEATURES
CONTROLS AND FEATURES
Read this operator’s manual before operating your generator. Familiarize yourself with the location and function of the controls and
features. Save this manual for future reference.
Generator
8
1
2
7
6
9
5
3
1. Carrying Handle – Used to lift or carry the unit.
2. Recoil Starter – Used to manually start the engine.
3. EZ Start Dial – Used to start and stop the generator.
4. Outlet Panel – See “Outlet Panel” section.
5. Power Panel – See “Power Panel” section.
6. Fuel Cap – Remove to add fuel.
10
4
7. Fuel Lever Vent – Turn this valve to the “ON” position to
supply air to the tank.
8. Fuel Fill Assist LED – Push-button LED used to illuminate
the gasoline fill area
9. Maintenance Cover
10. Muffler
11
100565 - 2000W PORTABLE INVERTER GENERATOR
Power Panel
CONTROLS AND FEATURES
1
234
1. AC Reset Button – Used to re-energize receptacles after
overload fault.
1a. OFF – Systems normal.
1b. Blinking Red – Overload fault.
2. Overload Indicator Light – When ON generator is
overloaded and power to receptacles is cut.
3. Low Oil Level Indicator
3a. Off – Oil level OK.
3b. Yellow – Oil level low. Unit will shut down or not start
until oil is at required level.
5
4. Receptacle Status
4a. Green – All systems OK.
4b. Off – Faults occurred and receptacle has no power.