Champion Power Equipment 100307 OPERATOR'S MANUAL

REGISTER YOUR PRODUCT ONLINE
at championpowerequipment.com
OPERATOR'S MANUAL
MODEL #100307
3500W DUAL FUEL GENERATOR
or visit championpowerequipment.com
SAVE THESE INSTRUCTIONS. This manual contains important safety precautions which should be read and understood before operating the product. Failure to do
Specifications, descriptions and illustrations in this manual are as accurate as known at the time of publication, but are subject to change without notice.
Covered by one or more of the following U.S. Patent Numbers: 10,598,101, 9,435,273, D710,802, and other U.S. and foreign patents pending.
REV 20210203 Champion Power Equipment, Inc., Santa Fe Springs, CA USA
100307 - 3500W DUAL FUEL GENERATOR
TABLE OF CONTENTS
TABLE OF CONTENTS
Introduction ................................................ 3
Safety Definitions Important Safety Instructions
Fuel Safety ...................................................... 6
Safety and Dataplate Labels .................................... 7
Safety Symbols .................................................. 8
Operation Symbols .............................................. 9
Controls and Features ...............................10
Generator ....................................................... 10
Control Panel ................................................... 11
Intelligauge .....................................................12
Parts Included .................................................. 13
Assembly ...................................................13
Unpacking ......................................................13
Remove Shipping Support Brackets ........................... 13
Add Engine Oil .................................................. 13
Add Fuel: Gasoline .............................................14
Add Fuel: Propane (LPG) .......................................15
Grounding ......................................................16
Operation ...................................................16
Generator Location ............................................. 16
Surge Protection ...............................................16
Fuel Selector ...................................................16
Starting the Engine: Gasoline .................................. 17
Starting the Engine: Propane (LPG) ...........................17
Connecting Electrical Loads ...................................18
Do Not Overload Generator ....................................18
Stopping the Engine ............................................ 19
Moving the Generator ..........................................19
Operation at High Altitude .....................................19
....................................... 3
.................... 4
Storage ..................................................... 22
Short Term Storage (up to 30 days) ...........................22
Mid Term Storage (30 days – 1 year) .........................22
Long Term Storage (over 1 year) ..............................22
Removing from Storage ........................................ 23
Specifications ........................................... 24
Generator Specifications ....................................... 24
Engine Specifications ..........................................24
Oil Specifications ............................................... 24
Fuel Specifications .............................................24
Temperature Specifications ....................................24
Parts Diagram ..................................................25
Parts List .......................................................26
Engine Parts Diagram ..........................................28
Engine Parts List ...............................................29
Wiring Diagram .................................................31
Troubleshooting ........................................ 32
Warranty*
Warranty Qualifications ........................................33
Repair/Replacement Warranty .................................33
Do Not Return The Unit To The Place Of Purchase ...........33
Warranty Exclusions ...........................................33
Other Exclusions ...............................................33
Limits of Implied Warranty and Consequential Damage ......33
Contact Information ............................................33
................................................. 33
Maintenance ............................................. 20
Cleaning the Generator ........................................20
Changing the Engine Oil .......................................20
Cleaning and Adjusting the Spark Plug ........................20
Cleaning the Air Filter ..........................................21
Cleaning the Spark Arrestor ...................................21
Adjusting the Governor ......................................... 21
Maintenance Schedule .........................................21
2
100307 - 3500W DUAL FUEL GENERATOR
INTRODUCTION
INTRODUCTION
Congratulations on your purchase of a Champion Power Equipment (CPE) product. CPE designs, builds, and supports all of our products to strict specifications and guidelines. With proper product knowledge, safe use, and regular maintenance, this product should bring years of satisfying service.
Every effort has been made to ensure the accuracy and completeness of the information in this manual at the time of publication, and we reserve the right to change, alter and/or improve the product and this document at any time without prior notice.
CPE highly values how our products are designed, manufactured, operated, and serviced as well as providing safety to the operator and those around the generator. Therefore, it is IMPORTANT to review this product manual and other product materials thoroughly and be fully aware and knowledgeable of the assembly, operation, dangers and maintenance of the product before use. Fully familiarize yourself, and make sure others who plan on operating the product fully familiarize themselves too, with the proper safety and operation procedures before each use. Please always exercise common sense and always err on the side of caution when operating the product to ensure no accident, property damage, or injury occurs. We want you to continue to use and be satisfied with your CPE product for years to come.
SAFETY DEFINITIONS
The purpose of safety symbols is to attract your attention to possible dangers. The safety symbols, and their explanations, deserve your careful attention and understanding. The safety warnings do not by themselves eliminate any danger. The instructions or warnings they give are not substitutes for proper accident prevention measures.
DANGER
DANGER indicates a hazardous situation which, if not avoided, will result in death or serious injury.
WARNING
WARNING indicates a hazardous situation which, if not avoided, could result in death or serious injury.
CAUTION
CAUTION indicates a hazardous situation which, if not avoided, could result in minor or moderate injury.
NOTICE
When contacting CPE about parts and/or service, you will need to supply the complete model and serial numbers of your product. Transcribe the information found on your product’s nameplate label to the table below
CPE TECHNICAL SUPPORT TEAM
1-877-338-0999
MODEL NUMBER
100307
SERIAL NUMBER
DATE OF PURCHASE
PURCHASE LOCATION
NOTICE indicates information considered important, but not hazard-related (e.g., messages relating to property damage).
3
100307 - 3500W DUAL FUEL GENERATOR
IMPORTANT SAFETY INSTRUCTIONS
IMPORTANT SAFETY INSTRUCTIONS
WARNING
Cancer and Reproductive Harm – www.P65Warnings.ca.gov
DANGER
Generator exhaust contains carbon monoxide, a colorless, odorless, poisonous gas. Breathing carbon monoxide will cause nausea, dizziness, fainting or death. If you start to feel dizzy or weak, get to fresh air immediately.
OPERATE GENERATOR OUTDOORS ONLY IN A WELL VENTILATED AREA AND POINT EXHAUST AWAY.
DO NOT operate the generator inside any building, including garages, basements, crawlspaces and sheds, enclosure or compartment, including the generator compartment of a recreational vehicle.
DO NOT allow exhaust fumes to enter a confined area through windows, doors, vents or other openings.
DANGER
Using a generator indoors CAN KILL YOU IN MINUTES. Generator exhaust contains carbon monoxide. This is a poison you cannot see or smell.
NEVER use inside a home or garage, EVEN IF doors and windows are open.
ONLY use OUTSIDE and far away from windows, doors, and vents.
DANGER
Operate equipment with guards in place.
Rotating parts can entangle hands, feet, hair, clothing and/or accessories. Traumatic amputation or severe laceration can result.
Keep hands and feet away from rotating parts.
Tie up long hair and remove jewelry.
DO NOT wear loose-fitting clothing, dangling drawstrings or items that could become caught.
DANGER
Generator produces powerful voltage.
DO NOT touch bare wires or receptacles.
DO NOT use electrical cords that are worn, damaged or frayed. Use only Champion electrical cords for proper application.
DO NOT operate generator in wet weather.
DO NOT allow children or unqualified persons to operate or service the generator.
Use a ground fault circuit interrupter (GFCI) in damp areas and areas containing conductive material such as metal decking.
Connection to your home’s electrical system requires a listed 30A transfer switch installed by a licensed electrician and approved by the local authority having jurisdiction. The connection must isolate the generator from the utility power and must comply with all applicable laws and electrical codes.
Install battery-operated carbon monoxide alarms or plug-in carbon monoxide alarms with battery back-up according to the manufacturer’s instructions.
WARNING
Although the generator contains a spark arrester, maintain a minimum distance of 5 ft. (1.5 m) from dry vegetation to prevent fires.
WARNING
Do not use generator for medical and life support uses.
In case of emergency, call 911 immediately.
NEVER use this product to power life support devices or life support appliances.
NEVER use this product to power medical devices or medical appliances.
Inform your electricity provider immediately if you or anyone in your household depends on electrical equipment to live.
Inform your electrical provider immediately if a loss of power would cause you or anyone in your household to experience a medical emergency.
4
100307 - 3500W DUAL FUEL GENERATOR
IMPORTANT SAFETY INSTRUCTIONS
WARNING
Spark from removed spark plug wire can result in fire or electrical shock.
When servicing the generator:
Disconnect the spark plug wire and place it where it cannot contact the plug or any other metal object.
DO NOT check for spark with the plug removed.
Use only approved spark plug testers.
WARNING
Running engines produce heat. Severe burns can occur on contact. Combustible material can catch fire on contact.
DO NOT touch hot surfaces.
Avoid contact with hot exhaust gases.
Allow equipment to cool before touching.
Maintain at least 3 ft. (91.4 cm) of clearance on all sides to ensure adequate cooling.
CAUTION
Start the generator and allow the engine to stabilize before connecting electrical loads.
Connect electrical equipment in the off position, and then turn them on for operation.
Turn electrical equipment off and disconnect before stopping the generator.
CAUTION
Improper treatment or use of the generator can damage it, shorten its life or void the warranty.
Use the generator only for intended uses.
Operate only on level surfaces.
DO NOT expose generator to excessive moisture, dust, or dirt.
DO NOT allow any material to block the cooling slots.
If connected devices overheat, turn them off and disconnect them from the generator.
Maintain at least 5 ft. (1.5 m) of clearance from combustible materials.
WARNING
Rapid retraction of the recoil cord will pull hand and arm towards the engine faster than you can let go. Unintentional startup can result in entanglement, traumatic amputation or laceration. Broken bones, fractures, bruises or sprains could result.
When starting engine, pull the recoil cord slowly until resistance is felt and then pull rapidly to avoid kickback.
DO NOT start or stop the engine with electrical devices plugged in and turned on.
CAUTION
Exceeding the generator’s running capacity can damage the generator and/or electrical devices connected to it.
DO NOT overload the generator.
DO NOT tamper with the governed speed.
DO NOT use the generator if:
– Electrical output is lost
– Equipment sparks, smokes or emits flames
– Equipment vibrates excessively
DO NOT modify the generator in any way.
5
100307 - 3500W DUAL FUEL GENERATOR
IMPORTANT SAFETY INSTRUCTIONS
Fuel Safety
DANGER
GASOLINE, GASOLINE VAPORS AND PROPANE (LPG) ARE HIGHLY FLAMMABLE AND EXPLOSIVE.
Fire or explosion can cause severe burns or death.
Gasoline and gasoline vapors:
– Gasoline is highly flammable and explosive.
– Gasoline can cause a fire or explosion if ignited.
– Gasoline is a liquid fuel but it’s vapors can ignite.
– Gasoline is a skin irritant and needs to be cleaned up
immediately if spilled on skin or clothes.
– Gasoline has a distinctive odor, this will help detect potential
leaks quickly.
– In any petroleum gas fire, flames should not be extinguished
unless by doing so the fuel supply valve can be turned OFF. This is because if a fire is extinguished and a supply of fuel is not turned OFF, then an explosion hazard could be created.
– Gasoline expands or contracts with ambient temperatures.
Never fill the gasoline tank to full capacity, as gasoline needs room to expand if temperatures rise.
LPG:
– LPG is highly flammable and explosive.
– LPG is under pressure and can cause a fire or explosion if
ignited.
– LPG is heavier than air and can settle in low places while
dissipating.
– LPG has a distinctive odor added to help detect potential leaks
quickly.
– In any petroleum gas fire, flames should not be extinguished
unless the fuel supply valve is turned OFF. This is because if a fire is extinguished and a supply of fuel is not turned OFF, then an explosion hazard could be created.
– When exchanging LPG cylinders, be sure the cylinder valve is
of the same type.
– Always keep the LPG cylinder in an upright position.
– LPG will burn skin if it comes in contact with it. Keep any and
all LPG away from skin at all times.
When adding or removing gasoline:
DO NOT light or smoke cigarettes.
Turn the generator off and let it cool for at least two minutes before removing the gasoline cap. Loosen the cap slowly to relieve pressure in the tank.
Only fill or drain gasoline outdoors in a well-ventilated area.
DO NOT pump gasoline directly into the generator at the gas station. Use an approved container to transfer the fuel to the generator.
DO NOT overfill the gasoline tank.
Always keep gasoline away from sparks, open flames, pilot lights, heat and other sources of ignition.
When starting the generator:
DO NOT attempt to start a damaged generator.
Make certain that the gasoline cap, air filter, spark plug, fuel lines and exhaust system are properly in place.
Allow spilled gasoline to evaporate fully before attempting to start the engine.
Make certain that the generator is resting firmly on level ground.
When operating the generator:
DO NOT move or tip the generator during operation.
DO NOT tip the generator or allow fuel or oil to spill.
When transporting or servicing the generator:
Make certain that the fuel valve is in the OFF position and the gasoline tank is empty.
For LPG compatible models, be sure that the LPG cylinder is disconnected and stored securely away from the generator.
Disconnect the spark plug wire.
When storing the generator:
Store away from sparks, open flames, pilot lights, heat and other sources of ignition.
Do not store generator, gasoline or LPG cylinders near furnaces, water heaters, or any other appliances that produce heat or have automatic ignitions.
WARNING
Never use a gasoline container, gasoline tank, LPG connector hose, LPG cylinder or any other fuel item that is broken, cut, torn or damaged.
6
100307 - 3500W DUAL FUEL GENERATOR
WARNING
ADVERTENCIA
AVERTISSEMENT
portes et trappes de ventilation.
1110-L-OP-B
UNLEADED F UEL ONLY. Minimum octane
rating of 87. Maximum 10 % ethanol.
GASOLINA REGULAR SOLAMENTE. 87 octanos
como mínimo. Máximo de etanol de 10%.
ESSENCE SAN S PLOMB SEULEM ENT.
Indice d’octan e minimal de 87.
Maximum 10 % d'éthan ol.
GN-SF -T-00 2.1
WHEN STORING GAS OLINE, PROPANE (LPG) O R EQUIPMENT WITH FU EL IN IT: Store away from
furnaces, stoves, water heater s or other appliances that have a pilot light or other ignition source b ecause they can ignite the fuel.
FOR USE IN A WEATHER-PRO TECTED AREA ONLY. DO NOT EXPOSE TO RA IN.
Operating of this equipment may create sparks that can start fi res around dry vegetation. A spark arrest er may be required. The operator should contact local fire agencies for laws or regulations relat ing to fire prevention requirements.
Read and follow all operating instr uctions before running engine.
Gasoline and propane (LP G) are extrememely flammable. Check for spilled fuel or fuel leaks. If one is found, shut off f uel supply and stop engine immediately. Allow to cool at least 2 minutes before refueling.
FOR ELECTRICAL E QUIPMENT ONLY.
DANGER
WARNING
CAUTION
GN-SF-E-005.1
CUANDO ALMACEN E GASOLINA, GAS PRO PANO (GLP) O EQUIPO CON COMB USTIBLE ADENTRO:
Almacene fuera de hornos, estufas, calentones de agua, o otros aparatos que tengan luz pilo to o otra fuente de encendido por que pueden encender el combustible.
PARA USO EN AREAS DE SPEJADAS SOLAME NTE. NO EXPONGA A LA L LUVIA.
La operación de este equipo puede or iginar chispas que pueden crear incendios cerc a de la vegetación seca. Es posible que s e requiera un parachispas. El operador deberá comunicarse con los organismos l ocales encargados de combatir incendios pa ra conocer las leyes o reglamentos relaci onados con los requisitos para prevenir incen dios.
Lea y acate todas las instrucc iones de operación antes de encender el motor.
La gasolina y el gas propano (GL P) son extremadamente inflamables. Ver ifique si hay combustible derramado o fugas de combustible. Si una es encontrada , apague el suministro y pare el motor inmediata­mente. Permita que se enfrié por los m enos 2 minutos antes de reabastecer lo.
PARA EQUIPOS ELÉCTRICOS SOLAMENTE.
PELIGRO
ADVERTENCIA
PRECAUCIÓN
GN-SF-S-005B.1
,
5
M
IMPORTANT SAFETY INSTRUCTIONS
Safety and Dataplate Labels
These labels warn you of potential hazards that can cause serious injury. Read them carefully.
If a label comes off or becomes hard to read, contact Technical Support Team for possible replacement.
E F
D
A
C
B
Top BackSide
A
A Safety Symbols
B Fuel
C Clearance Safety
D CO Danger
E Hot Surface
F Transfer Switch
DO NOT TOUCH!
Exhaust gases, mu ffler and engine component s are extremely HOT and cause burns.
DANGER
PELIGRO
DANGER
Operation of this equip ment may create sparks th at can start fires around dry vege tation. A spark arres tor may be required. The operator should contact local fire agencies for laws and regulations rel ating to fire prevention re quirements. If installed, clean eve ry 100 hours or every sea son.
LABEL DESCRIPTION
M
I
5
N
E
C
I
M
A
P
M
S
E
'
D
5
,
M
U
1
M
I
N
I
M
O
Using a generator indoors CAN KILL YOU IN MINUTES. Generator exhaust
contains carbon monoxide. This is a poison you cannot see or smell.
El uso de un generador en interiores PUEDE MATARLO EN MINUTOS. El escape del generador cont iene monóxido de carbono. Éste es un veneno que no se puede ver ni oler. NUNCA lo use dentro del hogar ni el garaje, INCLUSO SI las
puertas y ventanas están abiert as. Úselo SÓLO a la INTEMPERIE lejos de ventanas, puertas, y ori ficios de ventilación.
Utiliser un générateur à l’intérieur PEUT VOUS TUER EN QUELQUES MINU TES. L’échappement du générateur contient du monoxyde de carbone. Il s’agit d’un poison que vous ne pouvez ni voir ni sentir. Ne l’utilisez JAMAIS dans la maison ou le
garage MÊME SI les portes et les fenêtres sont ouvertes. Utilisez-le UNIQUEMENT À L’EXTÉRIEUR, loin des fenêtres,
¡NO TOCAR! Los gases de escape, el silenciador y lo s compnonentes del motor están extremadamente CA LIENTES y causan quemaduras.
CAUTION
A transfer switch MU ST be used when connecting gener ator to a building’s electrical system. See Owner’s Manual.
La operación de este e quipo puede producir chis pas que pueden provocar incendios alrededor de la vegetación seca. Un supresor de chispas puede que sea necesario. El operador debe comunicarse con las agencias locales de bomberos para las leyes y reglamentos relativos a los requisitos de prevención de incendios. Si está in stalado, limpie cada 100 hor as o cada temporada.
Es OBLIGATORI O usar un interruptor de transferencia cuando se conecte el generador al sistema eléctric o de un inmueble. Vea el manual del propietario
M
I
N
Í
I
O
M
PRECAUCIÓN
U
S
P
A
C
1
F
M
C
T
L
.
E
A
R
A
N
C
E
E
NEVER use inside a home or garage, EVEN IF doors and windows are open.
ONLY use OUTSIDE and far away from windows, doors, and vents.
MISE EN GARDE
Le commutateur de tr ansfert DOIT être utilisé pour connecter la génératrice au système électrique d’un immeuble. Consulter le manuel du p ropriétaire.
7
1308-L-SF-C
NE PAS TOUCHER! Les gaz d’échappement, le silencieux et les pièces du moteur son t extrêmement CHA UDS et peuvent causer des brûlures.
Cet équipement peut cr éer des étincelles et provo quer un incendie dans la végétation sèche. Un pa re-étincelles peut ê tre requis. L’utilisateur doit communiquer avec le serv ice d’incendie local pour co nnaître les lois et les règlements en matiè re de prévention des incend ies. Si elle est installée, nettoye z la génératrice toutes les 100 heures ou chaque saison.
1035-L-SF-C
100307 - 3500W DUAL FUEL GENERATOR
IMPORTANT SAFETY INSTRUCTIONS
Safety Symbols
Some of the following symbols may be used on this product. Please study them and learn their meaning. Proper interpretation of these symbols will allow you to more safely operate the product.
SYMBOL MEANING
Read Operator’s Manual. To reduce the risk of injury, user must read and understand operator’s manual
before using this product.
Clearance. Keep all objects at least 5 ft (1.5m) from generator. Heat from the muffler and exhaust gas can ignite combustible objects.
Ground. Consult with local electrician to determine grounding requirements before operation.
Electric Shock. Failure to use in dry conditions and to observe safe practices can result in electric
shock. Improper connections to a building can allow current to backfeed into utility lines, creating an electrocution hazard. A transfer switch must be used when connecting to a building.
Fire/Explosion. Fuel and its vapors are extremely flammable and explosive. Fire or explosion can cause severe burns or death. Keep generator at least 5 ft (1.5m) from all objects to prevent combustion.
Hot Surface. To reduce the risk of injury or damage, avoid contact with any hot surface.
Open Flame Alert. Fuel and its vapors are extremely flammable and explosive. Keep fuel away from
smoking, open flames, sparks, pilot lights, heat, and other ignition sources.
Wet Conditions Alert. Do not expose to rain or use in damp locations.
8
100307 - 3500W DUAL FUEL GENERATOR
IMPORTANT SAFETY INSTRUCTIONS
Operation Symbols
Some of the following symbols may be used on this product. Please study them and learn their meaning. Proper interpretation of these symbols will allow you to more safely operate the product.
SYMBOL MEANING
Propane Fuel Source. Turn off fuel
source when generator is not in use
RV Ready Receptacle
Ground Terminal
SÍMBOLO SIGNIFICADO
Choke
Run
Gasoline Valve
Propane Valve
9
100307 - 3500W DUAL FUEL GENERATOR
CONTROLS AND FEATURES
CONTROLS AND FEATURES
Read this operator’s manual before operating your generator. Familiarize yourself with the location and function of the controls and features. Save this manual for future reference.
Generator
1
2
3
9
8
7
4
5
1. Gasoline Tank – 3.4 gal. (13 L)
2. Choke – Used to start the engine.
3. Air Filter – Protects the engine by filtering dust and debris
from the intake air.
4. Recoil Starter – Used to manually start the engine.
5. LPG Hose Connector
6
10
6. Oil Fill Cap/Dipstick – Used to check and fill oil level.
7. Control Panel – See “Control Panel” section.
8. Fuel Selector – Used to select fuel source.
9. Carrying Handle(s) – Used to lift or carry the unit.
10. Ground Terminal – Consult an electrician for local grounding
regulations.
10
100307 - 3500W DUAL FUEL GENERATOR
Control Panel
CONTROLS AND FEATURES
1
A B C 5
4
2 3
1. Fuel Selector – Used to select and turn on gasoline or
propane (LPG) fuel source.
2. Engine Switch – Used to put in START mode or STOP the
generator. When operating by propane, this switch will NOT stop the engine.
3. Intelligauge – Three mode digital meter for displaying total
run time, voltage and hertz.
4. LPG Inlet – Used to connect LPG fuel source to generator.
5. Circuit Breakers (Push Reset) – Protects the generator
against electrical overloads.
RECEPTACLES
120V AC, 30A RV (NEMA TT-30R)
A
t
B
W
C
A
May be used to supply electrical power for operation of 120 Volt AC, 30 Amp, single phase, 60 Hz electrical loads.
120V AC, 30A Locking (NEMA L5-30R) May be used to supply electrical power for operation of 120 Volt AC, 30 Amp, single phase, 60 Hz electrical loads.
(2×) 120V AC, 20A (NEMA 5-20R) May be used to supply electrical power for operation of 120 Volt AC, 20 Amp, single phase, 60 Hz electrical loads.
11
Loading...
+ 25 hidden pages