Important Safety Instructions
are included in this manual.
G
M
I
L
A
R
D
E
T
I
3
Y
E
A
A
N
T
A
W
R
R
A
N
T
Y
S
O
Ñ
R
Í
A
A
A
•
D
A
T
I
M
I
L
MODEL NUMBER
100261
12039 Smith Ave.
Santa Fe Springs CA 90670 USA
MADE IN CHINA
REV 100261-20200103
www.championpowerequipment.com
1-877-338-0999
FCC Statement
1. This device complies with Part 15 of the FCC Rules.
Operation is subject to the following two conditions:
(1) This device may not cause harmful interference.
(2) This device must accept any interference
received, including interference that may cause
undesired operation.
2. Changes or modifications not expressly approved by
the party responsible for compliance could void the
user’s authority to operate the equipment.
NOTE: This equipment has been tested and found to
comply with the limits for a Class B digital device,
pursuant to Part 15 of the FCC Rules. These limits
are designed to provide reasonable protection against
harmful interference in a residential installation.
This equipment generates uses and can radiate radio
frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful
interference to radio communications. However, there
is no guarantee that interference will not occur in a
particular installation. If this equipment does cause
harmful interference to radio or television reception,
which can be determined by turning the equipment
off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
– Reorient or relocate the receiving antenna.
– Increase the separation between the equipment and
receiver.
– Connect the equipment into an outlet on a
circuit different from that to which the receiver is
connected.
Consult the dealer or an experienced radio/TV technician
for help.
Have questions or need assistance?
Do not return this product to the store!
WE ARE HERE TO HELP!
Visit our website:
www.championpowerequipment.com
for more info:
• Product Info & Updates
• Frequently Asked Questions
– or –
Call our Customer Care Team Toll-Free at:
1-877-338-0999
• Tech Bulletins
• Product Registration
Parts Ordering:
Mon – Fri 8:30 AM – 5:00 PM (PST/PDT)
Toll Free: 1-877-338-0999
*We are always working to improve our products. Therefore, the enclosed product may differ slightly from the image on the cover.
TABLE OF CONTENTS
100261
3400 Starting Watts / 3100 Running Watts
Wireless Remote, electric start
PORTABLE INVERTER GENERATOR
Introduction ............................ 1
Introduction ..........................1
Portable Power Generator .................1
Accessories ..........................1
This Booklet ..........................1
Manual Conventions ....................... 2
Safety Rules ............................ 3
Controls and Features ..................... 5
Generator ............................5
Parts Included ........................5
Power Panel ..........................6
Safety Label Locations ...................7
Wireless Remote Control .................8
Remote Control Power Consumption .........8
Assembly .............................. 9
Remove the Generator from the Shipping Carton .9
Connecting the Battery ..................9
Add Engine Oil .......................10
Add Fuel ...........................11
Grounding ..........................11
Operation ............................. 12
Generator Location ....................12
Grounding ..........................12
Wireless Remote Start ..................12
Electric and Recoil Start ................13
Manual Choke Start ....................14
Economy Control Switch .................14
Connecting Electrical Loads ..............15
12V DC Outlet .......................15
Stopping the Engine ...................15
Do Not Overload Generator ...............16
Capacity .........................16
Power Management ..................16
Overload Operation ....................16
Operation at High Altitude ...............16
Wireless Set Button ....................17
Parallel Operation .....................17
Maintenance and Storage .................. 18
Engine Maintenance ...................18
Oil .............................18
Spark Plugs .......................18
Air Filter .........................19
Cleaning .........................19
Spark Arrester Cleaning ...............19
Adjustments .......................19
Maintenance Schedule................19
Generator Battery ....................19
Charge the Battery ...................20
Disconnect the Battery ................20
Remote Control Battery ................20
Generator Maintenance .................20
Storage ............................20
Generator Storage ...................20
Specifications .......................... 21
Engine Specifications ..................21
Generator Specifications ................21
Fuel ..............................21
Oil ...............................21
Spark Plugs .........................21
Maintenance Valve Clearance .............21
An Important Message About Temperature ....21
Wiring Diagram .......................22
Parts Diagram ........................23
Parts List ...........................24
Engine Parts Diagram ..................27
Engine Parts List .....................28
Troubleshooting ......................... 29
ENGLISH100261
INTRODUCTION
Introduction
Congratulations on your purchase of a Champion Power Equipment product. Champion Power Equipment and
Champion Engine Technology designs, builds, and supports all of our products to strict specifications and guidelines.
With proper product knowledge, safe use, and regular maintenance, this product should bring years of satisfying
service.
Every effort has been made to ensure the accuracy and completeness of the information in this manual, and we
reserve the right to change, alter and/or improve the product and this document at any time without prior notice.
Since CPE/CET highly value how our products are designed, manufactured, operated and are serviced, and also
highly value your safety and the safety of others, we would like you to take the time to review this product manual
and other product materials thoroughly and be fully aware and knowledgeable of the assembly, operation, dangers
and maintenance of the product before use. Fully familiarize yourself, and make sure others who plan on operating
the product fully familiarize themselves too, with the proper safety and operation procedures before each use. Please
always exercise common sense and always error on the side of caution when operating the product to ensure no
accidents, property damage, or injury occurs. We want you to continue to use and be satisfied with your CPE/CET
product for years to come.
Record the model and serial numbers as well as date and place of purchase for future reference. Have this
information available when ordering parts and when making technical or warranty inquiries.
Champion Power Equipment Support
1-877-338-0999
Model Number
100261
Serial Number
Date of Purchase
Purchase Location
For O il Typ e see ‘Add Engine Oil‘ section. For Fue l Typ e see ‘Add Fuel‘ section.
1
100261 ENGLISH
MANUAL CONVENTIONS
This manual uses the following symbols to help differentiate between different kinds of information. The safety symbol
is used with a key word to alert you to potential hazards in operating and owning power equipment.
Follow all safety messages to avoid or reduce the risk of serious injury or death.
DANGER
DANGER indicates an imminently hazardous
situation which, if not avoided, will result in death
or serious injury.
WARNING
WARNING indicates a potentially hazardous
situation which, if not avoided, could result in
death or serious injury.
CAUTION
CAUTION indicates a potentially hazardous
situation which, if not avoided, may result in minor
or moderate injury.
CAUTION
CAUTION used without the safety alert symbol
indicates a potentially hazardous situation which, if
not avoided, may result in property damage.
NOTE
If you have questions regarding your generator, we can
help. Please call our help line at 1-877-338-0999
2
SAFETY RULES
ENGLISH100261
WARNING
Read this manual thoroughly before operating your
generator. Failure to follow instructions could result
in serious injury or death.
DANGER
Generator exhaust contains carbon monoxide, a
colourless, odourless, poison gas. Breathing carbon
monoxide will cause nausea, dizziness, fainting or
death. If you start to feel dizzy or weak, get to fresh
air immediately.
Operate generator outdoors only in a well ventilated
area.
DO NOT operate the generator inside any building,
including garages, basements, crawlspaces and
sheds, enclosure or compartment, including the
generator compartment of a recreational vehicle.
DO NOT allow exhaust fumes to enter a confined
area through windows, doors, vents or other
openings.
DANGER CARBON MONOXIDE: using a generator
indoors CAN KILL YOU IN MINUTES.
DANGER
Generator produces powerful voltage.
DO NOT touch bare wires or receptacles.
DO NOT use electrical cords that are worn, damaged
or frayed.
DO NOT operate generator in wet weather.
DO NOT allow children or unqualified persons to
operate or service the generator
Use a ground fault circuit interrupter (GFCI) in damp
areas and areas containing conductive material such
as metal decking.
Use approved transfer equipment to isolate generator
from your electric utility and notify your utility
company before connecting your generator to your
power system.
WARNING
Sparks can result in fire or electrical shock.
When servicing the generator:
Disconnect the spark plug wire and place it where it
cannot contact the plug.
DO NOT check for spark with the plug removed.
Use only approved spark plug testers.
WARNING
DANGER
Rotating parts can entangle hands, feet, hair,
clothing and/or accessories.
Traumatic amputation or severe laceration can result.
Keep hands and feet away from rotating parts.
Tie up long hair and remove jewelry.
Operate equipment with guards in place.
DO NOT wear loose-fitting clothing, dangling
drawstrings or items that could become caught.
WARNING
This product contains a button battery. If
swallowed, it could cause severe injury or death in
just 2 hours. Seek medical attention immediately.
WARNING
Operation of this equipment may create sparks that
can start fires around dry vegetation.
A spark arrestor may be required. The operator
should contact local fire agencies for laws or
regulations relating to fire prevention requirements.
Running engines produce heat. Severe burns can
occur on contact.
Combustible material can catch fire on contact.
DO NOT touch hot surfaces.
Avoid contact with hot exhaust gases.
Allow equipment to cool before touching.
Maintain at least 3 ft. (91.4 cm) of clearance on all
sides to ensure adequate cooling.
Maintain at least 5 ft. (1.5 m) of clearance from
combustible materials.
WARNING
Medical and Life Support Uses.
In case of emergency, call 911 immediately.
NEVER use this product to power life support
devices or life support appliances.
NEVER use this product to power medical devices
or medical appliances.
Inform your electricity provider immediately if you
or anyone in your household depends on electrical
equipment to live.
Inform your electrical provider immediately if a
loss of power would cause you or anyone in your
household to experience a medical emergency.
3
100261 ENGLISH
SAFETY RULES
DANGER
Fuel and fuel vapours are highly flammable and
extremely explosive.
Fire or explosion can cause severe burns or death.
Unintentional startup can result in entanglement,
traumatic amputation or laceration.
When adding or removing fuel:
Turn the generator off and let it cool for at least two
minutes before removing the fuel cap. Loosen the
cap slowly to relieve pressure in the tank.
Only fill or drain fuel outdoors in a well-ventilated area.
DO NOT pump gas directly into the generator at the
gas station. Use an approved container to transfer
the fuel to the generator.
DO NOT overfill the fuel tank.
Always keep fuel away from sparks, open flames,
pilot lights, heat and other sources of ignition.
DO NOT light or smoke cigarettes.
When starting the generator:
DO NOT attempt to start a damaged generator.
Make certain that the gas cap, air filter, spark plug,
fuel lines and exhaust system are properly in place.
Allow spilled fuel to evaporate fully before
attempting to start the engine.
Make certain that the generator is resting firmly on
level ground.
When operating the generator:
DO NOT move or tip the generator during operation.
DO NOT tip the generator or allow fuel or oil to spill.
When transporting or servicing the generator:
Make certain that the fuel shutoff valve is in the off
position and the fuel tank is empty.
Disconnect the spark plug wire.
When storing the generator:
Store away from sparks, open flames, pilot lights,
heat and other sources of ignition.
WARNING
Cancer and Reproductive Harm –
www.P65Warnings.ca.gov
WARNING
Rapid retraction of the starter cord will pull hand and
arm towards the engine faster than you can let go.
Unintentional startup can result in entanglement,
traumatic amputation or laceration.
Broken bones, fractures, bruises or sprains could result.
When starting engine, pull the starter cord slowly
until resistance is felt and then pull rapidly to avoid
kickback.
DO NOT start or stop the engine with electrical
devices plugged in.
CAUTION
Exceeding the generator’s running capacity can
damage the generator and/or electrical devices
connected to it.
DO NOT overload the generator.
Start the generator and allow the engine to stabilize
before connecting electrical loads.
Connect electrical equipment in the off position,
and then turn them on for operation.
Turn electrical equipment off before stopping the
generator.
DO NOT tamper with the governed speed.
DO NOT modify the generator in any way.
CAUTION
Improper treatment or use of the generator can
damage it, shorten its life and void your warranty.
Use the generator only for intended uses.
Operate only on level surfaces.
DO NOT expose generator to excessive moisture,
dust, or dirt.
DO NOT allow any material to block the cooling slots.
If connected devices overheat, turn them off and
disconnect them from the generator.
DO NOT use the generator if:
– Electrical output is lost
– Equipment sparks, smokes or emits flames
– Equipment vibrates excessively
4
ENGLISH100261
CONTROLS AND FEATURES
Read this owner’s manual before operating your generator. Familiarize yourself with the location and function of the
controls and features. Save this manual for future reference.
Generator
1
2
(1) Fuel Cap – Remove to add fuel.
(2) Recoil Starter – Used to start the engine.
(3) Power Panel
(4) Foldaway Handle – Do not use the foldaway handle
34
to lift or carry the unit.
5
6
798
(5) Muffler
(6) Carrying Handle
(7) Maintenance Cover
(8) Never Flat Wheels
(9) Battery Access Cover
Parts Included
Your 100261 gasoline powered generator ships with the
following parts:
– Dual 2.4A Port USB Adapter ................1
– Oil funnel .............................1
– Remote ..............................1
5
100261 ENGLISH
Power Panel
CONTROLS AND FEATURES
161211
15
14
13
1
2
3
8
4
5
6
7
9
8
10
(1) Fuel Valve Knob
(2) Push-Button Choke
(3) Economy Control Switch
(4) Wireless Set Button
(5) Red Pilot Lamp
(6) Ground Terminal – Consult an electrician for local
grounding regulations.
(7) 12V DC Outlet*
(8) Circuit Breaker (Push-button) – Protects the
generator against electrical overload.
(9) Parallel Outlets – used for parallel operation.
(10) 120 Volt AC, 20 Amp Duplex (NEMA 5-20R) –
May be used to supply electrical power for the
operation of 120 Volt AC, 20 Amp, single phase
60 Hz electrical loads.
(11) Battery Switch
(12) 120 Volt AC, 30 Amp Receptacle (NEMA TT-30R)
– May be used to supply electrical power for the
operation of 120 Volt AC, 30 Amp, single phase
60 Hz electrical loads.
(13) Oil Warning Light – Check oil level when this light
turns on. Engine will not run when indicator is lit.
(14) Overload Indicator Light – This light turns ON
when the generator is overloaded and will cut
power to the receptacles.
(15) Output Light – Remains ON during normal
operating conditions. Shuts OFF when generator is
overloaded.
(16) Ignition Switch
*Warning: Do not operate a device while it is plugged into
the 12V DC outlet. Prolonged exposure to engine exhaust
can cause serious injury or death. While charging a device
do no place on the exhaust side of the generator. Extreme
heat caused by exhaust can damage the device, and cause a
potential fire hazard.
6
ENGLISH100261
CONTROLS AND FEATURES
Safety Label Locations
These labels warn you of potential hazards that can cause serious injury. Read them carefully.
If a label comes off or becomes hard to read, contact Champion Power Equipment’s customer service department for
possible replacement.
F
D
A
B
C
E
A
C
A
P
M
S
E
'
D
5
,
M
U
1
M
I
N
I
M
O
M
D
FOR USE IN A WEA THER PRO TECTE D AREA ONLY - D O NOT EXP OSE TO RA IN
WHEN STORING GASOLINE, PROPANE (LPG) OR EQUIPMENT WITH FUEL IN
IT: Store away from furnaces, stoves, water heaters or other appliances that
have a pilot light or other ignition source because they can ignite the fuel.
Read and follow operating instructions before running engine.
Gasoline and propane (LPG) are extrememely flammable. Check for
spilled fuel or fuel leaks. If one is found, shut off fuel supply and stop
engine immediately. Allow to cool at least 2 minutes before refueling.
Operation of this equipment may create sparks that can start fires around dry
vegetation. A spark arrester may be required. The operator should contact local
fire agencies for laws or regulations relating to fire prevention requirements.
FOR ELECTRICAL EQUIPMENT ONLY.
F
DO NOT TOUCH!
Exhaust gas es, muffler
and engine compone nts
are extremely H OT and
cause burns.
B
M
I
5
N
E
I
M
U
F
M
C
T
L
.
E
A
R
A
N
C
E
E
S
P
A
I
C
N
Í
I
O
M
1
5
,
M
DANGER
WARNING
CAUTION
Operation of thi s equipment may create spar ks that can start
fires around dr y vegetation. A spark ar restor may be
required. The operator should contact local fire agencies for
laws and regulatio ns relating to fire preventi on requirements.
If installed, cl ean every 100 hours or ever y season.
ES
PARA USO EN AREAS DESPEJADAS SOLAMENTE - NO EXPONGA A LA LLUVIA
CUANDO ALM ACENE GA SOLINA , GAS PROPA NO (GLP) O EQ UIPO CON COMB USTIBL E ADENTR O: Almacene
fuera de hornos, estufas, calentones de agua, o otro s aparatos que tengan luz piloto o otra fuente de
encendido por que pueden encender el combustible.
Lea y acate las instrucciones de operación antes de enc ender el motor.
La gasolina y el gas propano (GLP) son extremadamente inflamables. Verifique si hay combustible
derramado o fugas de combustible. Si una es encontrada, apague el suministro y pare el motor
inmediatamente. Permita que se enfrié por los menos 2 minutos antes de reabastecerlo.
La operación de este equipo puede originar chispas que pueden crear incendios cerca de la vegetación seca. Es
posible que se requiera un parachispas. El operador deberá comunicarse con los organismos locales encargados
de combatir incendios para conocer las leyes o reglamentos relacionados con los requisitos para prevenir incendios.
PARA EQUIP O ELÉCTR ICO SOLA MENTE
WARNING
UNLEADED FUEL ONLY. Minimum octane rating
of 85. Maximum 10% e thanol.
GASOLINA REGULAR SOLAMENTE. 85 octanos
como mínimo. Máxi mo de etanol de 10%.
ESSENCE SANS PLOMB SEULEMENT. Indice
d’octane minimal de 8 5. Maximum 10 % d'étha nol.
PELIGRO
ADVERTENCIA
PRECAUCIÓN
¡NO TOCAR! Lo s gases de
escape, el silencia dor y los
compnonentes del motor están
extremadamen te CALIENTES y
causan quemaduras.
Using a generator indoors CAN KILL
DANGER
C
1032-L-OP-A
YOU IN MINUTES. Generator exhaust
contains carbon monoxide. This is a
poison you cannot see or smell.
El uso de un generador en interiores PUEDE MATARLO EN MINUTOS. El escape del generador contiene monóxido de carbono.
PELIGRO
Éste es un veneno que no se puede ver ni oler. NUNCA lo use dentro del hogar ni el garaje, INCLUSO SI las puer tas y ventanas
están abiertas. Úselo SÓL O a la INTEMPERIE lejos de ventanas, puertas, y orificios de ventilación.
Utiliser un générateur à l’intérieur PEUT VOUS TUER EN QUELQUES MINUTES. L’échappement du générateur contient du
DANGER
monoxyde de carbone. Il s’agit d’un poison que vous ne pouvez ni voir ni sentir. Ne l’utilisez JAMAIS dans la maison ou le garage
MÊME SI les portes et les fenêtres sont ouvert es. Utilisez-le UNIQUEMENT À L’EXTÉRIEUR, loin des fenêtres, portes e t trappes
de ventilation.
E
STOP / ALTO / ARRÊT
NO OIL IN UNIT! / ¡NO TIENE ACEITE! / MANQUE D’HUILE DANS L’UNITÉ!
REMOVE PANEL TO FILL OIL / QUITE EL PANEL PARA AGREGAR ACEITE
RETIRER LE PANNEAU POUR REMPLIR D’HUILE
ADVERTENCIA
La operación de es te equipo puede produci r chispas que pueden provo car
incendios alrededor de la vegetación seca. Un supresor de chispas puede que
sea necesario. El operador debe comunicarse con las agencias locales de
bomberos para las leyes y reglamentos relativos a los requisitos de prevención
de incendios. Si es tá instalado, limpie cad a 100 horas o cada temporad a.
NEVER use inside
a home or garage,
EVEN IF doors and
windows are open.
READ YOUR OWNER’S MANUAL BEFORE OPERATION.
ADD OIL BEFORE INITIAL START UP. AUTOMATIC LOW OIL
SHUTOFF WILL PREVENT STARTING WITHOUT ADDING OIL.
LEA EL MANUAL ANTES DE OPERACIÓN.
AGREGUE ACEITE ANTES DE PRIMER USO. SENSOR DE NIVEL
DE ACEITE AUTOMATICO. UNIDAD FALLA DE ENCENDER
SIN ACEITE.
LIRE LE GUIDE D’UTILISATION AVANT DE FAIRE FONCTIONNER.
AJOUTER DE L’HUILE AVANT LE DÉMARRAGE INITIAL. LA
FERMETURE AUTOMATIQUE EN CAS DE MANQUE D’HUILE
EMPÊCHERA LE DÉMARRAGE SANS AJOUT D’HUILE.
ONLY use OUTSIDE
and far away from
windows, doors,
and vents.
1308-L-SF-B
1291-L-SF-A
7
100261 ENGLISH
Wireless Remote Control
This generator is equipped with a wireless remote
control system for starting and stopping. The system
consists of (4) main components:
1. Receiver Control Module (RCM)
2. Wireless Remote
3. Battery Switch
4. Ignition Switch
The Remote Control functions are enabled when:
1. The Ignition Switch is in the “ON” position, AND
2. The Battery Switch is in the “ON” position.
The Remote Control functions are disabled if either of
the above conditions is not met.
To start the generator by Remote Control, press the
“START” button on the Remote one time. The engine
will attempt to start (6) times. The RCM controls
the Auto Choke during each attempt to start. If the
generator does not start, call Champion Customer Care
team for assistance at 1-877-338-0999.
To stop the generator by Remote Control, press the
“STOP” button on the Remote one time.
CONTROLS AND FEATURES
Remote Control Power Consumption
While the Ignition Switch is in the “ON” position, the
RCM is active and waiting for a remote signal. This
function requires electrical current from the battery.
If the Ignition Switch is left in the “ON” position for
extended periods (several weeks), the battery can be
completely drained.
Moving the Ignition Switch to the “OFF” position
disables the Remote functions, but the RCM still
consumes approximately 2 mA from the battery.
To prevent battery drain, press the Battery Switch to the
“OFF” position. This disconnects power to the RCM so
there is no current draw on the battery.
8
Loading...
+ 25 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.