Champion Power Equipment 100212 Operator's Manual for All Serial Numbers in

OWNER’S MANUAL & OPERATING INSTRUCTIONS
4000 Starting Watts / 3500 Rated Watts Recoil Start
PORTABLE GENERATOR
MODEL NUMBER
100212
12039 Smith Ave.
SAVE THESE INSTRUCTIONS
MADE IN CHINA
REV 100212-20150304
www.championpowerequipment.com
Santa Fe Springs CA 90670
USA / 1-877-338-0999
AN IMPORTANT MESSAGE ABOUT TEMPERATURE:
Your Champion Power Equipment product is designed and rated for continuous operation at ambient temperatures up to 40°C (104°F). When your product is needed your product may be operated at temperatures ranging from -15°C (5°F) to 50°C (122°F) for short periods. If the product is exposed to temperatures outside this range during storage, it should be brought back within this range before operation. In any event, the product must always be operated outdoors, in a well-ventilated area and away from doors, windows and other vents.
Have questions or need assistance?
Do not return this product to the store!
WE ARE HERE TO HELP!
Visit our website:
www.championpowerequipment.com
for more info:
• Product Info & Updates
• Frequently Asked Questions
– or –
Call our Customer Care Team Toll-Free at:
1-877-338-0999
• Tech Bulletins
• Product Registration
WARNING:
The Engine Exhaust from this product contains chemicals known to the State of California
to cause cancer, birth defects or other reproductive harm.
*We are always working to improve our products. Therefore, the enclosed product may differ slightly from the image on the cover.
TABLE OF CONTENTS
100212
4000 Starting Watts / 3500 Rated Watts
Recoil Start
PORTABLE GENERATOR
Introduction ............................ 1
Introduction .......................... 1
Manual Conventions ....................... 2
Safety Rules ............................ 3
Controls and Features ..................... 5
Generator ............................ 5
Power Panel .......................... 6
Parts Included ........................ 7
Wheel Kit .......................... 7
Other ............................ 7
Assembly .............................. 8
Remove the Generator from the Shipping Carton . 8
Install the Wheel Kit .................... 8
Install the Support Leg .................. 8
Install the Handle ...................... 8
Add Engine Oil ........................ 9
Add Fuel ........................... 10
Grounding .......................... 10
Operation ............................. 11
Generator Location .................... 11
Grounding .......................... 11
Surge Protection ...................... 11
Recoil Start ......................... 12
Connecting Electrical Loads .............. 12
Stopping the Engine ................... 12
Do Not Overload Generator ............... 13
Capacity ......................... 13
Power Management .................. 13
Operation at High Altitude ............... 13
Maintenance and Storage .................. 14
Engine Maintenance ................... 14
Oil ............................. 14
Spark Plugs ....................... 14
Air Filter ......................... 14
Spark Arrester ..................... 15
Cleaning ......................... 15
Adjustments ....................... 15
Maintenance Schedule ................ 15
Generator Maintenance ................. 16
Storage ............................ 16
Generator Storage ................... 16
Specifications .......................... 17
Engine Specifications .................. 17
Generator Specifications ................ 17
Fuel .............................. 17
Oil ............................... 17
Spark Plugs ......................... 17
Maintenance Valve Clearance ............. 17
An Important Message About Temperature .... 17
Wiring Diagram ....................... 18
Parts Diagram ........................ 19
Parts List ........................... 20
Engine Parts Diagram .................. 21
Engine Parts List ..................... 22
Troubleshooting ......................... 23
Warranty ............................. 24
Warranty Qualifications ................. 24
Repair/Replacement Warranty ............. 24
Do Not Return The Unit To
The Place Of Purchase .................. 24
Warranty Exclusions. . . . . . . . . . . . . . . . . . . . 24
Normal Wear ...................... 24
Installation, Use and Maintenance ........ 24
Other Exclusions .................... 24
Limits of Implied Warranty
and Consequential Damage ............ 24
Contact Information .................... 24
Address .......................... 24
Customer Service ................... 24
Technical Service ................... 24
ENGLISH 100212
INTRODUCTION
Introduction
Congratulations on your purchase of a Champion Power Equipment product. Champion Power Equipment and Champion Engine Technology designs, builds, and supports all of our products to strict specifications and guidelines. With proper product knowledge, safe use, and regular maintenance, this product should bring years of satisfying service.
Every effort has been made to ensure the accuracy and completeness of the information in this manual, and we reserve the right to change, alter and/or improve the product and this document at any time without prior notice.
Since CPE/CET highly value how our products are designed, manufactured, operated and are serviced, and also highly value your safety and the safety of others, we would like you to take the time to review this product manual and other product materials thoroughly and be fully aware and knowledgeable of the assembly, operation, dangers and maintenance of the product before use. Fully familiarize yourself, and make sure others who plan on operating the product fully familiarize themselves too, with the proper safety and operation procedures before each use. Please always exercise common sense and always error on the side of caution when operating the product to ensure no accidents, property damage, or injury occurs. We want you to continue to use and be satisfied with your CPE/CET product for years to come.
Record the model and serial numbers as well as date and place of purchase for future reference. Have this information available when ordering parts and when making technical or warranty inquiries.
Champion Power Equipment Support
1-877-338-0999
Model Number
100212
Serial Number
Date of Purchase
Purchase Location
For O il Typ e see ‘Add Engine Oil‘ section. For Fuel Typ e see ‘Add Fuel‘ section.
1
100212 ENGLISH
MANUAL CONVENTIONS
This manual uses the following symbols to help differentiate between different kinds of information. The safety symbol is used with a key word to alert you to potential hazards in operating and owning power equipment. Follow all safety messages to avoid or reduce the risk of serious injury or death.
DANGER
DANGER indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury.
WARNING
WARNING indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury.
CAUTION
CAUTION indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury.
CAUTION
CAUTION used without the safety alert symbol indicates a potentially hazardous situation which, if not avoided, may result in property damage.
NOTE
If you have questions regarding your generator, we can help. Please call our help line at 1-877-338-0999.
2
SAFETY RULES
ENGLISH 100212
WARNING
Read this manual thoroughly before operating your generator. Failure to follow instructions could result in serious injury or death.
WARNING
The engine exhaust from this product contains chemicals known to the state of California to cause cancer, birth defects, or other reproductive harm.
DANGER
Generator exhaust contains carbon monoxide, a colorless, odorless, poison gas. Breathing carbon monoxide will cause nausea, dizziness, fainting or death. If you start to feel dizzy or weak, get to fresh air immediately.
Operate generator outdoors only in a well ventilated area. DO NOT operate the generator inside any building, including garages, basements, crawlspaces and sheds, enclosure or compartment, including the generator compartment of a recreational vehicle. DO NOT allow exhaust fumes to enter a confined area through windows, doors, vents or other openings. DANGER CARBON MONOXIDE: using a generator indoors CAN KILL YOU IN MINUTES.
DANGER
Rotating parts can entangle hands, feet, hair, clothing and/or accessories. Traumatic amputation or severe laceration can result.
DANGER
Generator produces powerful voltage.
DO NOT touch bare wires or receptacles. DO NOT use electrical cords that are worn, damaged or frayed. DO NOT operate generator in wet weather. DO NOT allow children or unqualified persons to operate or service the generator Use a ground fault circuit interrupter (GFCI) in damp areas and areas containing conductive material such as metal decking. Use approved transfer equipment to isolate generator from your electric utility and Notify your utility company before connecting your generator to your power system.
WARNING
Sparks can result in fire or electrical shock.
When servicing the generator:
Disconnect the spark plug wire and place it where it cannot contact the plug. DO NOT check for spark with the plug removed. Use only approved spark plug testers.
WARNING
Running engines produce heat. Severe burns can occur on contact. Combustible material can catch fire on contact.
DO NOT touch hot surfaces. Avoid contact with hot exhaust gases. Allow equipment to cool before touching. Maintain at least 3 ft. (91.4 cm) of clearance on all sides to ensure adequate cooling. Maintain at least 5 ft. (1.5 m) of clearance from combustible materials.
WARNING
Keep hands and feet away from rotating parts. Tie up long hair and remove jewelry. Operate equipment with guards in place. DO NOT wear loose-fitting clothing, dangling drawstrings or items that could become caught.
Medical and Life Support Uses.
In case of emergency, call 911 immediately. NEVER use this product to power life support devices or life support appliances. NEVER use this product to power medical devices or medical appliances. Inform your electricity provider immediately if you or anyone in your household depends on electrical equipment to live. Inform your electrical provider immediately if a loss of power would cause you or anyone in your household to experience a medical emergency.
3
100212 ENGLISH
SAFETY RULES
DANGER
Fuel and fuel vapors are highly flammable and extremely explosive. Fire or explosion can cause severe burns or death. Unintentional startup can result in entanglement, traumatic amputation or laceration.
When adding or removing fuel:
Turn the generator off and let it cool for at least two minutes before removing the fuel cap. Loosen the cap slowly to relieve pressure in the tank. Only fill or drain fuel outdoors in a well-ventilated area. DO NOT pump gas directly into the generator at the gas station. Use an approved container to transfer the fuel to the generator. DO NOT overfill the fuel tank. Always keep fuel away from sparks, open flames, pilot lights, heat and other sources of ignition. DO NOT light or smoke cigarettes.
When starting the generator:
DO NOT attempt to start a damaged generator. Make certain that the gas cap, air filter, spark plug, fuel lines and exhaust system are properly in place. Allow spilled fuel to evaporate fully before attempting to start the engine. Make certain that the generator is resting firmly on level ground.
When operating the generator:
DO NOT move or tip the generator during operation. DO NOT tip the generator or allow fuel or oil to spill.
When transporting or servicing the generator:
Make certain that the fuel shutoff valve is in the off position and the fuel tank is empty. Disconnect the spark plug wire.
When storing the generator:
Store away from sparks, open flames, pilot lights, heat and other sources of ignition.
WARNING
Operation of this equipment may create sparks that can start fires around dry vegetation.
A spark arrestor may be required. The operator should contact local fire agencies for laws or regulations relating to fire prevention requirements.
WARNING
Rapid retraction of the starter cord will pull hand and arm towards the engine faster than you can let go. Unintentional startup can result in entanglement, traumatic amputation or laceration. Broken bones, fractures, bruises or sprains could result.
When starting engine, pull the starter cord slowly until resistance is felt and then pull rapidly to avoid kickback. DO NOT start or stop the engine with electrical devices plugged in.
CAUTION
Exceeding the generator’s running capacity can damage the generator and/or electrical devices connected to it.
DO NOT overload the generator. Start the generator and allow the engine to stabilize before connecting electrical loads. Connect electrical equipment in the off position, and then turn them on for operation. Turn electrical equipment off and disconnect before stopping the generator. DO NOT tamper with the governed speed. DO NOT modify the generator in any way.
CAUTION
Improper treatment or use of the generator can damage it, shorten its life and void your warranty.
Use the generator only for intended uses. Operate only on level surfaces. DO NOT expose generator to excessive moisture, dust, or dirt. DO NOT allow any material to block the cooling slots. If connected devices overheat, turn them off and disconnect them from the generator. DO NOT use the generator if:
– Electrical output is lost – Equipment sparks, smokes or emits flames – Equipment vibrates excessively
4
ENGLISH 100212
CONTROLS AND FEATURES
Read this owner’s manual before operating your generator. Familiarize yourself with the location and function of the controls and features. Save this manual for future reference.
Generator
1
2 3
4
9
8
7
5
(1) Fuel Tank – 3.8 gal. (14.4 L) capacity fuel tank.
(2) Choke – Used to start the engine.
(3) Fuel Valve – Used to turn fuel supply on and off to
engine.
(4) Air Filter – Protects the engine by filtering dust
and debris from the intake air.
(5) Recoil Starter – Used to manually start the engine.
6
(6) Never Flat Tires
(7) Oil Filler Cap – Check and fill engine oil level.
(8) Power Panel – See “Power Panel” section.
(9) Handle
5
100212 ENGLISH
Power Panel
CONTROLS AND FEATURES
1
(1) Engine Switch – Used to start or stop the
generator.
(2) Circuit Breakers – Protects the generator against
electrical overloads.
(3) 120 Volt AC, 30 Amp Receptacle (NEMA TT-30R)
– May be used to supply electrical power for the operation of 120 Volt AC, single phase 60 Hz electrical loads.
(4) AC Output Indicator – Indicates when power is
being delivered to receptacle.
2
43 5 6 7
(5) 120 Volt AC, 30 Amp Twist-Lock Receptacle
(NEMA L5-30R) – May be used to supply electrical power for the operation of 120 Volt AC, single phase 60 Hz electrical loads.
(6) 120 Volt AC, 20 Amp Receptacle (NEMA 5-20R)
– May be used to supply electrical power for the operation of 120 Volt AC, single phase 60 Hz electrical loads.
(7) Ground Terminal – Consult an electrician for local
grounding regulations.
6
CONTROLS AND FEATURES
Parts Included
Your 100212 Gasoline Powered Generator ships with the following parts:
Wheel Kit
– 8 in. Wheel ...........................2
– Flange Bolt (M10x105 for Wheel) ............2
– Bushing ..............................2
– Flat Washer Ø10 ........................2
– Lock Nut (M10) ........................2
– Support Leg w/Vibration Mounts .............1
– Flange Bolt (M8x16 for Support Leg) ..........2
– Handle ..............................1
– Flange Bolt (M8x45 for Handle) .............2
– Flange Lock Nut (M8) ....................4
Other
– Oil Funnel ............................1
ENGLISH 100212
7
100212 ENGLISH
ASSEMBLY
Your generator requires some assembly. This unit ships from our factory without oil. It must be properly serviced with fuel and oil before operation. If you have any questions regarding the assembly of your generator, call our help line at 1-877-338-0999. Please have your serial number and model number available.
Remove the Generator from the Shipping Carton
1. Set the shipping carton on a solid, flat surface.
2. Remove everything from the carton except the generator.
3. Carefully cut each corner of the box from top to bottom. Fold each side flat on the ground to provide a surface area to install the wheel kit and support leg.
Install the Wheel Kit
CAUTION
The wheel kit is not intended for over-the-road use.
You will need the following tools to install the wheels:
• 17 mm wrench OR adjustable wrench (not included)
• Socket wrench with a 16 mm socket (not included)
• Pliers (not included)
1. Before adding fuel and oil, tip the generator on it’s side.
2. Slide the M10x105 wheel flange bolt through the washer, sleeve and wheel.
3. Slide the bolt through the mount point on the frame.
4. Fasten securely with the M10 lock nut.
5. Repeat steps 2-4 to attach the second wheel.
Install the Support Leg
1. Attach the support leg to the generator frame with flange bolts (M8x16) and flange lock nuts (M8).
2. Tip the generator slowly so that it rests on the wheels and support leg.
Install the Handle
1. Place the handle over the mounting channel on the frame.
2. Secure the handle to the frame using the two handle flange bolts (M8x45).
3. Place a flange lock nut (M8) on the end of each bolt and fasten securely. DO NOT over tighten the lock nuts.
8
ASSEMBLY
ENGLISH 100212
Add Engine Oil
CAUTION
DO NOT attempt to crank or start the engine before it has been properly filled with the recommended type and amount of oil. Damage to the generator as a result of failure to follow these instructions will void your warranty.
NOTE
The generator rotor has a sealed, pre-lubricated ball bearing that requires no additional lubrication for the life of the bearing.
NOTE
The recommended oil type is 10W-30 automotive oil.
1. Place the generator on a flat, level surface.
Add Engine Oil Cont’d.
NOTE
Check oil often during the break-in period. Refer to the Maintenance section for recommended service intervals.
CAUTION
The engine is equipped with a low oil shut-off and will stop when the oil level in the crankcase falls below the threshold level.
NOTE
We consider the first 5 hours of run time to be the break-in period for the unit. During the break in period stay at or below 50% of the running watt rating and vary the load occasionally to allow stator windings to heat and cool. Adjusting the load will also cause engine speed to vary and help seat piston rings. After the 5 hour break-in period, change the oil.
2. Remove oil fill cap/dipstick to add oil.
3. Add up to 0.6 qt. (0.6 L) of oil and replace oil fill cap/dipstick. DO NOT OVERFILL.
4. Check engine oil level daily and add as needed.
NOTE
Once oil has been added, a visual check should show oil about 1-2 threads from running out of the fill hole. If using the dipstick to check oil level, DO NOT screw in the dipstick while checking.
Degrees Celsiusº
Full Synthetic 5W-30
Degrees Fahrenheitº
(Outside)
(Outside)
NOTE
Weather will affect engine oil and engine performance. Change the type of engine oil used based on weather conditions to suit the engine needs.
NOTE
Synthetic oil may be used after the 5 hour initial break-in period. Using synthetic oil does not increase the recommended oil change interval.
9
100212 ENGLISH
ASSEMBLY
Add Fuel
1. Use clean, fresh, regular unleaded fuel with a minimum octane rating of 85 and an ethanol content of less than 10% by volume.
2. DO NOT mix oil with fuel.
3. Clean the area around the fuel cap.
4. Remove the fuel cap.
5. Slowly add fuel to the tank. DO NOT OVERFILL. Fuel can expand after filling. A minimum of ¼ in. (6.4 mm) of space left in the tank is required for fuel expansion, more than ¼ in. (6.4 mm) is recommended. Fuel can be forced out of the tank as a result of expansion if it is overfilled, and can affect the stable running condition of the product. When filling the tank, it is recommended to leave enough space for the fuel to expand.
Add Fuel Cont’d.
NOTE
Our engines work well with 10% or less ethanol blend fuels. When using blended fuels there are some issues worth noting:
– Ethanol-gasoline blends can absorb more water
than gasoline alone.
– These blends can eventually separate, leaving
water or a watery goo in the tank, fuel valve and carbureto r.
– With gravity-fed fuel supplies, this compromised
fuel can be drawn into the carburetor and cause damage to the engine and/or potential hazards.
– There are only a few suppliers of fuel stabilizer
that are formulated to work with ethanol blend fuels.
– Any damages or hazards caused by using
improper fuel, improperly stored fuel, and/ or improperly formulated stabilizers, are not
covered by manufacture’s warranty. It is advisable to always shut off the fuel supply, run the engine to fuel starvation and drain the tank when the equipment is not in use for more than 30 days.
6. Screw on the fuel cap and wipe away any spilled fuel.
CAUTION
Use regular unleaded gasoline with a minimum octane rating of 85.
Do not mix oil and gasoline. Fill tank to approximately ¼ in. (6.4 mm) below the top of the tank to allow for fuel expansion. DO NOT pump gas directly into the generator at the gas station. Use an approved container to transfer the fuel to the generator. DO NOT fill fuel tank indoors. DO NOT fill fuel tank when the engine is running or hot. DO NOT overfill the fuel tank. DO NOT light cigarettes or smoke when filling the fuel tank.
WARNING
Grounding
Your generator must be properly connected to an appropriate ground to help prevent electric shock.
WARNING
Failure to properly ground the generator can result in electric shock.
A ground terminal connected to the frame of the generator has been provided on the power panel. For remote grounding, connect of a length of heavy gauge (12 AWG minimum) copper wire between the generator ground terminal and a copper rod driven into the ground. We strongly recommend that you consult with a qualified electrician to ensure compliance with local electrical codes.
Pouring fuel too fast through the fuel screen may result in blow back of fuel at the operator while filling.
10
OPERATION
ENGLISH 100212
Generator Location
NEVER operate the generator inside any building, including garages, basements, crawlspaces and sheds, enclosure or compartment, including the generator compartment of a recreational vehicle. Please consult your local authority. In some areas, generators must be registered with the local utility. Generators used at construction sites may be subject to additional rules and regulations. Generators should be on a flat, level surface at all times. (Even while not in operation) Generators must have at least 5 ft. (1.5 m) of clearance from all combustible material. In addition to clearance from all combustible material, generators must also have at least 3 ft. (91.4 cm) of clearance on all sides to allow for adequate cooling, maintenance and servicing. Generators should never be started or operated in the back of a SUV, camper, trailer, in the bed of a truck (regular, flat or otherwise), under staircases/stairwells, next to walls or buildings, or in any other location that will not allow for adequate cooling of the generator and/or the muffler. DO NOT contain generators during operation. Allow generators to properly cool before transport or storage. Place the generator in a well-ventilated area. DO NOT place the generator near vents or intakes where exhaust fumes could be drawn into occupied or confined spaces. Carefully consider wind and air currents when positioning generator.
Failure to follow proper safety precautions may void
manufacturer’s warranty.
Grounding
The generator system ground connects the frame to the ground terminals on the power panel.
– The generator (stator winding) is isolated from the
frame and from the AC receptacle ground pin.
– Electrical devices that require a grounded receptacle
pin connection will not function if the receptacle ground pin is not functional.
Surge Protection
CAUTION
Voltage fluctuation may impair the proper
functioning of sensitive electronic equipment.
Electronic devices, including computers and many programmable appliances use components that are designed to operate within a narrow voltage range and may be affected by momentary voltage fluctuations. While there is no way to prevent voltage fluctuations, you can take steps to protect sensitive electronic equipment.
1. Install UL1449, CSA-listed, plug-in surge suppressors
on the outlets feeding your sensitive equipment.
Surge suppressors come in single- or multi-outlet styles. They’re designed to protect against virtually all short-duration voltage fluctuations.
11
WARNING
Do not operate or store the generator in rain, snow, or wet weather.
Using a generator or electrical appliance in wet conditions, such as rain or snow, or near a pool or sprinkler system, or when your hands are wet, could result in electrocution.
WARNING
During operation the muffler and exhaust fumes produced will become hot. If adequate cooling and breathing space are not supplied, or if the generator is blocked or contained, temperatures can become extremely heated and may lead to fire.
100212 ENGLISH
OPERATION
Recoil Start
1. Make certain the generator is on a flat, level surface.
2. Turn off all electrical loads connected to the generator. Never start or stop the generator with electrical devices plugged in and turned on.
3. Turn the Fuel Valve to the “ON” position.
4. Press the engine Switch to “ON”.
5. Move the choke lever to the “CHOKE” position.
6. Pull the starter cord slowly until resistance is felt and then pull rapidly.
7. Do not over-choke. As as soon as engine starts, move the choke lever to the “RUN” position.
NOTE
Keep choke lever in “Choke” position for only 1 pull of the recoil starter. After first pull, move choke lever to the “Run” position for up to the next 3 pulls of the recoil starter. Too much choke leads to spark plug fouling/engine flooding due to the lack of incoming air. This will cause the engine not to start.
NOTE
If the engine starts but does not continue to run make certain that the generator is on a flat, level surface. The engine is equipped with a low oil sensor that will prevent the engine from running when the oil level falls below a critical threshold.
Connecting Electrical Loads
1. Let the engine stabilize and warm up for a few minutes after starting
2. Plug in and turn on the desired 120 Volt AC single phase, 60 Hz electrical loads.
– DO NOT connect 3-phase loads to the generator. – DO NOT connect 50 Hz loads to the generator. – DO NOT overload the generator.
NOTE
Connecting a generator to your electric utility company’s power lines or to another power source may be against the law. In addition this action, if done incorrectly, could damage your generator and appliances and could cause serious injury or even death to you or a utility worker who may be working on nearby power lines. If you plan to run a portable electric generator during an outage, please notify your electric utility company immediately and remember to plug your appliances directly into the generator. Do not plug the generator into any electric outlet in your home. Doing so could create a connection to the utility company power lines. You are responsible for ensuring that your generator’s electricity does not feed back into the electric utility power lines. If the generator will be connected to a building electrical system, consult your local utility company or a qualified electrician. Connections must isolate generator power from utility power and must comply with all applicable laws and codes.
Stopping the Engine
1. Turn off and unplug all electrical loads. Never start
or stop the generator with electrical devices plugged in or turned on.
2. Let the generator run at no-load for several minutes
to stabilize internal temperatures of the engine and generator.
3. Turn the Fuel Valve to the “OFF” position.
4. Let the engine run until fuel starvation has stopped
the engine. This usually takes a few minutes.
5. Press the engine switch to the “OFF” position.
Important: Always ensure that the Fuel Valve and the Engine Switch are in the “OFF” position when the engine is not in use.
NOTE
If the engine will not be used for a period of two (2) weeks or longer, please see the Storage section for proper engine and fuel storage.
12
OPERATION
ENGLISH 100212
Do Not Overload Generator
Capacity
Follow these simple steps to calculate the running and starting watts necessary for your purposes.
1. Select the electrical devices you plan on running at the same time.
2. Total the running watts of these items. This is the amount of power you need to keep your items running.
3. Identify the highest starting wattage of all devices identified in step 1. Add this number to the number calculated in step 2. Surge wattage is the extra burst of power needed to start some electric driven equipment. Following the steps listed under “Power Management” will guarantee that only one device will be starting at a time.
Power Management
Use the following formula to convert voltage and amperage to watts:
Volts x Amps = Watts
To prolong the life of your generator and attached devices, follow these steps to add electrical load:
1. Start the generator with no electrical load attached
2. Allow the engine to run for several minutes to stabilize.
3. Plug in and turn on the first item. It is best to attach the item with the largest load first.
4. Allow the engine to stabilize.
5. Plug in and turn on the next item.
6. Allow the engine to stabilize.
7. Repeat steps 5-6 for each additional item.
NOTE
Never exceed the specified capacity when adding loads to the generator.
Operation at High Altitude
The density of air at high altitude is lower than at sea level. Engine power is reduced as the air mass and air­fuel ratio decrease. Engine power and generator output will be reduced approximately 3½% for every 1000 feet of elevation above sea level. This is a natural trend and cannot be changed by adjusting the engine. At high altitudes increased exhaust emissions can also result due to the increased enrichment of the air fuel ratio. Other high altitude issues can include hard starting, increased fuel consumption and spark plug fouling. To alleviate high altitude issues other than the natural power loss, Champion Power Equipment can provide a high altitude carburetor main jet. The alternative main jet and installation instructions can be obtained by contacting Customer Support. Installation instructions are also available in the Technical Bulletin area of the Champion Power Equipment internet site. The part number and recommended minimum altitude for the application of the high altitude carburetor main jet is listed in the table below. In order to select the correct high altitude main jet it is necessary to identify the carburetor model. For this purpose, a code is stamped on the side of the carburetor. Select the correct main jet part number corresponding to the carburetor code found on your particular carburetor.
Carburetor Code
P19-2-Z
P19-2-H
Main Jet Part Number Altitude
Standard 26. 131017.20. Z
Altitude 26.131017.20 .01.Z
Standard 26. 131017.20. H
Altitude 26.131017.20 .01.H
3500 Feet (1067 Meters)
WARNING
Operation using the alternative main jet at elevations lower than the recommended minimum altitude can damage the engine. For operation at lower elevations, the standard main jet must be used. Operating the engine with the wrong engine configuration at a given altitude may increase its emissions and decrease fuel efficiency and performance.
13
100212 ENGLISH
MAINTENANCE AND STORAGE
The owner/operator is responsible for all periodic maintenance.
WARNING
Never operate a damaged or defective generator.
WARNING
Tampering with the factory set governor will void your warranty.
WARNING
Improper maintenance will void your warranty.
NOTE
Maintenance, replacement, or repair of emission control devices and systems may be performed by any non-road engine repair establishment or individual.
Complete all scheduled maintenance in a timely manner. Correct any issue before operating the generator.
Oil Cont’d.
NOTE
Once oil has been added, a visual check should show oil about 1-2 threads from running out of the fill hole. If using the dipstick to check oil level, DO NOT screw in the dipstick while checking.
Spark Plugs
1. Remove the spark plug cable from the spark plug.
2. Use a 13/16 in. or 21 mm socket (not included) to remove the plug.
3. Inspect the electrode on the plug. It must be clean and not worn to produce the spark required for ignition.
4. Make certain the spark plug gap is 0.7 - 0.8 mm
NOTE
For service or parts assistance, contact our help line at 1-877-338-0999
Engine Maintenance
To prevent accidental starting, remove and ground spark plug wire before performing any service.
Oil
Change oil when the engine is warm. Refer to the oil specification to select the proper grade of oil for your operating environment.
1. Remove the oil drain plug with a 12 mm socket and extension.
2. Allow the oil to drain completely.
3. Replace the drain plug.
4. Remove oil fill cap/dipstick to add oil.
5. Add up to 0.6 qt. (0.6 L) of oil and replace oil fill cap /dipstick. DO NOT OVERFILL.
6. Dispose of used oil at an approved waste management facility.
0.7 - 0.8 mm
0.028 - 0.031 in.
(0.028 - 0.031 in.).
5. Refer to the spark plug recommendation in the specifications section, of this manual, when replacing the plug.
6. Carefully thread the plug into the engine.
7. Use a 13/16 in. or 21 mm socket (not included) to firmly install the plug.
8. Attach the spark plug wire to the plug.
Air Filter
1. Remove the snap-on cover holding the air filter to the assembly.
2. Remove the foam element.
3. Wash in liquid detergent and water. Squeeze thoroughly dry in a clean cloth.
4. Saturate in clean engine oil.
5. Squeeze in a clean, absorbent cloth to remove all excess oil.
6. Place the filter in the assembly.
7. Reattach the air filter cover and snap in place.
14
MAINTENANCE AND STORAGE
ENGLISH 100212
Spark Arrester
1. Allow the engine to cool completely before servicing the spark arrester.
2. Remove the two screws holding the cover plate which retains the end of the spark arrester to the muffler.
3. Remove the spark arrester screen.
4. Carefully remove the carbon deposits from the spark arrester screen with a wire brush.
5. Replace the spark arrester if it is damaged.
6. Position the spark arrester in the muffler and attach cover plate with the two screws.
CAUTION
Failure to clean the spark arrester will result in degraded engine performance.
NOTE
Federal and local laws and administrative requirements indicate when and where spark arresters are required. When ordered, spark arresters are required for operation of this generator in National Forest lands. In California, this generator must not be used on any forest- covered land, brush-covered land, or grass- covered land unless the engine is equipped with a spark arrester.
Cleaning
CAUTION
Adjustments
The air-fuel mixture is not adjustable. Tampering with the governor can damage your generator and your electrical devices and will void your warranty. CPE recommends that you contact our service line at 1-877-338-0999 for all other service and/or adjustment needs.
Maintenance Schedule
Follow the service intervals indicated in the following maintenance schedule. Service your generator more frequently when operating in adverse conditions. Contact our helpline at 1-877-338-0999 to locate the nearest Champion Power Equipment certified service dealer for your generator or engine maintenance needs.
Every 8 hours or daily
Check oil level
Clean around air intake and muffler
First 5 Hours
Change oil
Every 50 hours or every season
Clean air filter
Change oil if operating under heavy load or in hot environments
Every 100 hours or every season
Change oil
Clean/Adjust spark plug
Check/Adjust valve clearance*
Clean spark arrester
Clean fuel tank and filter*
Every 250 hours
Clean combustion chamber*
Every 3 years
Replace fuel line
*To be performed by knowledgeable, experienced owners or Champion Power Equipment certified dealers.
DO NOT spray engine with water.
Water can contaminate the fuel system.
Use a damp cloth to clean exterior surfaces of the engine. Use a soft bristle brush to remove dirt and oil. Use an air compressor (25 PSI) to clear dirt and debris from the engine.
15
100212 ENGLISH
MAINTENANCE AND STORAGE
Generator Maintenance
Make certain that the generator is kept clean and stored properly. Only operate the unit on a flat, level surface in a clean, dry operating environment. DO NOT expose the unit to extreme conditions, excessive dust, dirt, moisture or corrosive vapors.
CAUTION
DO NOT use a garden hose to clean the generator.
Water can enter the generator through the cooling slots and damage the generator windings.
Use a damp cloth to clean exterior surfaces of the generator. Use a soft bristle brush to remove dirt and oil. Use an air compressor (25 PSI) to clear dirt and debris from the generator. Inspect all air vents and cooling slots to ensure that they are clean and unobstructed.
Storage
The generator should be started at least once every 14 days and allowed to run for at least 20 minutes. For longer term storage, please follow these guidelines.
Generator Storage
1. Add a properly formulated fuel stabilizer to the tank.
2. Be sure all appliances are disconnected from the generator.
3. Run the generator for a few minutes so the treated fuel cycles through the fuel system and carburetor.
4. Turn the fuel valve to the “Off” position.
5. Let the generator run until fuel starvation has stopped the engine. This usually takes a few minutes.
6. The generator needs to cool completely before cleaning and storage.
7. Clean the generator according to the maintenance section.
8. Change the oil.
9. Remove the spark plug and pour about 1⁄2 ounce (14.8 mL) of oil into the cylinder. Crank the engine slowly to distribute the oil and lubricate the cylinder.
10. Reattach the spark plug.
11. Store the unit in a clean, dry place out of direct
sunlight.
Generator Storage Cont’d.
NOTE
Our engines work well with 10% or less ethanol blend fuels. When using blended fuels there are some issues worth noting:
– Ethanol-gasoline blends can absorb more water
than gasoline alone.
– These blends can eventually separate, leaving
water or a watery goo in the tank, fuel valve and carbureto r.
– With gravity-fed fuel supplies, this compromised
fuel can be drawn into the carburetor and cause damage to the engine and/or potential hazards.
– There are only a few suppliers of fuel stabilizer
that are formulated to work with ethanol blend fuels.
– Any damages or hazards caused by using
improper fuel, improperly stored fuel, and/ or improperly formulated stabilizers, are not
covered by manufacture’s warranty. It is advisable to always shut off the fuel supply, run the engine to fuel starvation and drain the tank when the equipment is not in use for more than 30 days.
DANGER
Generator exhaust contains odorless and colorless carbon monoxide gas.
To avoid accidental or unintended ignition of your generator during periods of storage, the following precautions should be followed:
– When storing the generator for short or extended
periods of time make sure that the Engine
Switch and the Fuel Valve are set in the OFF
position.
16
SPECIFICATIONS
ENGLISH 100212
Engine Specifications
– Model .....................YF168FD-2-010
– Displacement .......................196cc
– Typ e ........................4-Stroke OHV
– Start Type .........................Recoil
Generator Specifications
– Model .......................... 100212
– Running Wattage .................3500 Watts
– Starting Wattage .................4000 Watts
– AC Load ..........................120 V
– Phase ............................Single
– Frequency .........................60 Hz
– Fuel Capacity ................3.8 gal. (14.4 L)
– Gross Weight ..............113.3 lb. (51.4 kg)
– Net Weight ................103.4 lb. (46.9 kg)
– Height ................... 21.9 in. (55.7 cm)
– Width .................... 22.4 in. (57 cm)
– Length. . . . . . . . . . . . . . . . . . . 26.3 in. (66.7 cm)
Fuel
Fuel capacity is 3.8 gal. (14.4 L). Use regular unleaded gasoline with a minimum octane rating of 85 and an ethanol content of less than 10% by volume.
Spark Plugs
OEM spark plug: NHSP F6RTC Replacement spark plug: NGK BPR6ES or equivalent
Make certain the spark plug gap is 0.7 - 0.8 mm or (0.028 - 0.031 in.).
Maintenance Valve Clearance
– Intake: 0.13 – 0.17 mm (0.005 – 0.007 in.)
– Exhaust: 0.18 – 0.22 mm (0.007 – 0.009 in.) Note: Tech bulletin regarding the valve adjustment procedure is on www.championpowerequipment.com.
An Important Message About Temperature
Your Champion Power Equipment product is designed and rated for continuous operation at ambient temperatures up to 40°C (104°F). When your product is needed your product may be operated at temperatures ranging from -15°C (5°F) to 50°C (122°F) for short periods. If the product is exposed to temperatures outside this range during storage, it should be brought back within this range before operation. In any event, the product must always be operated outdoors, in a well-ventilated area and away from doors, windows and other vents.
Oil
Use 10W-30 automotive oil. Oil capacity is up to 0.6 qt. (0.6 L). DO NOT OVERFILL. Please reference the following chart for recommended oil types for use in the generator.
Degrees Celsiusº
Full Synthetic 5W-30
Degrees Fahrenheitº
(Outside)
(Outside)
NOTE
Weather will affect engine oil and engine performance. Change the type of engine oil used based on weather conditions to suit the engine needs.
17
100212 ENGLISH
Wiring Diagram
R
R
20A
R
120V
120V
SPECIFICATIONS
TERMINAL
EARTH
Y
G/Y
5-20R
w
L5-30R
G/Y
W
G/Y
ENG SW
B
Y
B
CONTROL BOX BLOCK
Y
OIL LEVEL SW
G/Y
CIRCUIT BREAKER
25A
CIRCUIT BREAKER
R R
120V
TT-30R
R
W
G/Y
Transition
B
G/Y
W
PILOT
R
MW1
W
W
B
AVR
Y
Y
L
L
+
R
Y
L
Y
Br
W
B
IGNITION COIL
ENGINE BLOCK
SPARKING PLUG
W
R
R
R
MW2
EXW
FW
GENERATOR BLOCK
BROWN
Br
BLACK
B
GREEN YELLOW
WHITE GREEN
BLACK WHITE
W/G
G/YGREEN
B/W
BLUE
YELLOW
L
Y
G
WHITE BLUE
INDIGO
In
W/L
RED
WHITE
R
W
18
SPECIFICATIONS
Parts Diagram
ENGLISH 100212
22
474850515253
49
46
45
13
57
56
44
55
54
43
42
41
40
39
38
37
32
34
35
33
36
31
27
30
29
28
16
25
26
27
3
2
1
23
24
22
14
13
12
11
10
9
8
7
6
5
4
95
96
19 20 21
17
18
17
16
15
94
93
92
91
90
89
19
59
58
60
56
61
62
63
64
65
66
27
717273
67 68 69
70
56
74
75
76
7385868788
84
83
82
81
80
7879
77
100212 ENGLISH
Parts List
# Part Number Description Qty
26.401.35 Engine, Blue 1
1
122.190005.00 Rubber, Fore-Cover, B 1
2
122.190005.01 Rubber, Fore-Cover, A
3
123.191100. 21
4
2.08.022 Flange Bolt M8 x 242
5
1.96.08 Washer ø8
6
1.7244.08 Washer, Lock ø8
7
123.191200.21
8
123 .191002.01 Stator Cover
9
122.190002.00 End Housing
10
2.08.065 Flange Bolt M6 x 168
11
1.97.1.06 Washer ø6
12
1.93.06 Washer, Lock ø6
13
122.190300.00 Carbon Brush Assembly
14
122.190004.01 Brush Holder
15
1.93.05 Washer, Lock ø5
16
1.5783.0516 Bolt M5 x 16
17
1.97.1.05 Washer ø5
18
122 .190200.03 AVR
19
1.16674.0516 Flange Bolt M5 x 16
20
122.190003.00.35 Generator End Cover, Blue
21
1.166 74. 0512 .2 Flange Bolt M5 x 12
22
122.190400.00 Terminal Block
23
122.190018.00 Bracket I, Muffler
24
1.166 74. 0 820 Flange Bolt M8 x 20
25
122.190018.01 Bracket II, Muffler
26
1.5789.0612 Flange Bolt M6 x 12
27
1.9074.4.0514
28
46 .101503.08 Plate, Spark Arrester
29
46 .101300.08 Spark Arrester Assembly
30
26.101000.00 Muffler
31
23.102000.03.2 Cover, Muffler
32
1.6175. 08 Nut M8
33
1.93.08 Washer, Lock ø8
34
1.848.08 Washer ø8
35
26.100001.00 Gasket, E xhaust
36
23.090006.21 Bracket, Air Cleaner
37
1.5789.06 08 Flange Bolt M6 x 8
38
23.070011.04 Pipe, Fuel 6.1in
39
2.06.007 Clamp, ø8 x b6
40
122.070400.05 Valve, Fuel
41
122.071000.05.57 Fuel Tank, Red
42
122.070 015.01 Mount Vibration, Fuel Tank
43
2.03.004 Washer ø24 x ø6.5 x 1.5
44
1.5789.0620.2 Flange Bolt M6 x 20
45
23.070301.00 Filter, Fuel
46
24.070100.00 Cap, Fuel Tank
47
24.070014.05 Pipe, Reversal Valve 630 mm
48
24.070030.00 Hole, Breather Tube
49
Rotor Assembly, A, 120 mm, No DC
Stator Assembly, A, 120 mm, No DC
Screw/ Washer Assembly M5 x 14
# Part Number Description Qty
2.06.006 Clamp ø7 x 1
50
24.070800.00 Reversal Valve
51
1.819.0510 Screw M5 x 10
1
1
1
1
1
1
1
1
4
4
8
1
1
3
3
2
1
2
1
3
1
1
3
1
7
2
1
1
1
1
2
2
2
1
1
1
1
2
1
1
4
4
4
1
52
122.072000.00 Meter Assembly, Fuel
53
152.200702.00 Cover, Handle
54
122.200700.03.2 Handle
55
1.6177.1.08 Nut M8, Flange Lock
56
1.5789.08 45 Flange Bolt M8 x 45
57
62314.0.6.2 Frame
58
2.05.001 Clamp ø8 x 6.5
59
122.201200.05 Mount 2, Motor
60
122.201200.0 4 Mount 1, Motor
61
1.6182.10 Lock Nut M10
62
122.201701.05.2 8 in. Wheel, Black
63
122.20 0016.01 Bushing ø16 x 10.5 x 59
64
1.96.10 Washer ø10, Flat
65
1.57 82.10105 Bolt M10 x 105
66
1.5789.0816 Flange Bolt M8 x 16
67
152.200002.00.2 Support Leg 60 mm
68
152.201400.00 Rubber, Support
69
1.5789.0825 Flange Bolt M8 x 25
70
1.6177.1.06 Nut M6, Flange Lock
71
5.19 00.0 26 Line, Ground
72
1.862.06 Washer, Lock ø6
73
100212.21 Control Panel Assembly
74
2.08.068.2 Flange Bolt M5 x 13
75
122.01.114 .2 Control Panel
76
5.1000.004.3 Switch, Ignition, Red
77
1.9074.4.0414.1
78
1.6177.1.04 .1 Nut M4, Flange Lock, Black
79
5.1120 .0 3 4 Receptacle TT-30R
80
5.1460.000 Indicator Light
81
5.1210.925 25 Amp Circuit Breaker
82
5.1120 .0 0 8 Receptacle L5-30R
83
5.1120 .0 30 Receptacle 5-20R
84
1.5783.0622.3 Bolt 6 x 22, Green
85
1.6175. 06 .3 Nut M6, Green
86
1.97.1.06.3 Washer ø6, Green
87
1.93.06.3 Washer, Lock ø6, Green
88
5.1210.920 20 Amp Circuit Breaker
89
5.1810.0 01 Over Voltage Protector
90
1.8 23 .0514 Screw M5 x 14
91
122.210003.01 Wire Jacket, Control Box
92
5.13 30 .0 01 Sheath, Wire ø14 × 200mm
93
122.210003.03 Plug, Control Box
94
122.210002.01 Control Box
95
100 212. 21.10 Wire Assembly
96
Bolt/Washer Assembly M4 x 14, Black
1
1
1
1
1
2
1
1
1
14
2
1
2
2
2
2
2
2
2
2
2
1
2
2
1
1
2
1
4
1
1
8
8
1
1
1
1
1
1
2
2
2
1
1
1
1
1
1
1
1
20
SPECIFICATIONS
Engine Parts Diagram
96
ENGLISH 100212
95
94
93
90
88
87
86
85
84
51
14
91
81
83
82
80
79
78
77
19
28
16
97
11
92
1
75
74
76
33
34
31
56
55
73
72
71
70
69
39
36
12
59
57
58
68
67
66
63
62
61
60
64
25
47
46
65
44
43
42
41
40
12
38
48
101
100
99
18
19
89
49
54
24
23
22
21
53
52
45
51
50
20
37
35
98
32
26
30
29
27
26
25
15
2
13
12
10
9
8
7
6
5
4
3
17
21
1
100212 ENGLISH
# Part Number Description Qty
1.5789.06 08 Flange Bolt M6 x 8 5
1
22.061100.00.2 Recoil Starter Cover, Black 1
2
21.061005.00 Recoil Starter Spring
3
2.10. 003 Rope ø5 x 1550
4
21.061001.01 Recoil Starter Reel
5
45.060003.00 Spring, Ratchet
6
45.060002.00 Starter Ratchet, Iron
7
45.060009.00 Spring Guide, Ratchet
8
45.060007.00 Ratchet Guide
9
45.060008.00 Screw, Ratchet Guide
10
24.040004.00 Guide Plate, Push Rod
11
1.5789.0612 Flange Bolt M6 x 12
12
24.080100.01.35 Fan Cover, Blue
13
24.0 9110 0.21 Base, Air Cleaner
14
21.061300.00 Recoil Handle
15
24.130004.20 Gasket, Air Cleaner
16
22.061000.00 Recoil Assembly
17
24.091000.21 Air Cleaner Assembly
18
26.131000.20
19
26.131000.21
2.03.016
20
2.02.006 Nut M14 x 1.5
21
21.060 001. 01 Pulley, Starter
22
23.080001.00 Cooling Fan
23
24.12010 0.06 Flywheel
24
2.11.0 01 Seal, Oil 25 x 41.3 x 6
25
2.03.020.1 Washer ø6.2 x ø15 x 0.5, Black
26
21.110100 .0 0 Gear, Governor
27
23.13010 0. 20 Choke Lever
28
21.110013.00 Shaft, Governor Gear
29
21.110011.0 0 Clip, Governor Gear
30
22.130003.00 Gasket, Carburetor
31
21.110012.01 Bushing, Governor Gear
32
24.130002.00 Gasket, Insulator
33
23.130001.00 Insulator, Carburetor
34
23.080600.00 Air Guide, Right Side
35
2.01.003 Stud Bolt M6 x 90
36
26.030100.00 Crankcase
37
21.127000.02 Sensor, Oil Level
38
26.010100.0 0 C ylinder Head
39
23.050200.00 Connecting Rod
40
25.0 50100.11 Crankshaft
41
1.276.6205 Bearing, 6205
42
24.030008.00 Gasket, Crankcase Cover
43
22.031000.00 Oil Dipstick Assembly, Black
44
2.03.021.1 Washer ø6.4 x ø13 x 1, Black
45
23.030007.01 Cover, Crankcase
46
1.5789.0832.0.8 Flange Bolt M8 x 32
47
23.0910 02.21 Seal, Air Cleaner
48
23.110006.00 Rod, Governor
49
21.110003.00 Arm, Governor
50
1. 6 17 7. 0 6 Nut M6, Flange
51
Carburetor
Washer, Drain Bolt ø10 x ø16 x 1.5
# Part Number Description Qty
21.110001.00 Shaft, Governor Arm
52
22.123000.01
53
1
1
1
2
2
1
1
1
1
8
1
1
1
1
1
1
1
2
1
1
1
1
2
2
1
1
1
1
1
1
1
1
1
2
1
1
1
1
1
2
1
1
1
1
6
1
1
1
1.5789.0625 Flange Bolt M6 x 25
54
23.110005.01 Spring, Throttle Return
55
23.110007.00 Spring, Governor
56
2.08.040 Bolt, Governor Arm, M6 × 21
57
21.110008.00 Pin, Shaf t
58
23 .1110 00. 20 Control Assembly
59
25.040013.00 Lifter, Valve
60
2.04.001 Dowel Pin, ø9 x 14
61
26.041000.00 Camshaft
62
2.14.012 Woodruff Key, 4 x 7.5 x 19
63
2.08.037 Bolt, Drain, 10 x 1.25 x 25
64
26.050005.00 Piston
65
23.050003.00 Pin, Piston
66
2.09.001 Circlip ø18 x 1
67
26.050303.00 Ring, Oil
68
26.050302.00 Ring, Second Piston
69
26.050301.00 Ring, First Piston
70
26.030009.00 Gasket, Cylinder Head
71
2.04.003 Dowel Pin, ø10 x 14
72
23.040002.00 Valve, Intake
73
23.040006.00 Valve, Exhaust
74
26.080400.00 Air Guide, Lower
75
2.15.002(F6RTC) Spark Plug F6RTC
76
1.5789.08 60 Flange Bolt M8 x 60
77
23.040017.00 Oil Seal, Valve
78
21.040003.00 Spring, Valve
79
21.040007.00 Retainer, Exhaust Valve Spring
80
21.040001.00 Retainer, Intake Valve Spring
81
21.040008.00 Rotator, Exhaust Valve
82
24.040202.00 Shaft, Rocker Arm
83
22.040009.00 Rocker Arm
84
22.040012.00 Screw, Valve Adjustment
85
21.040021.0 0 Nut M6 x 0.5, Lock
86
1.97.1.06 Washer ø6
87
1.6177.1.06 Nut M6, Flange Lock
88
26.1 31 017. 2 0 Standard Main Jet
89
26.131017.20.01 Altitude Main Jet
24.040201.00 Retainer, Rocker Arm
90
23.040010.00 Bolt, Rocker Arm
91
23.040005.00 Push Rod
92
21.020002.01 Gasket, Cylinder Head Cover
93
24.021000.00 Cover, Cylinder Head
94
23.020001.02 Breather Tube
95
1.5789.0615 Flange Bolt M6 x 15
96
2.01.010 Stud Bolt M8 x 35
97
1.5789.0620 Flange Bolt M6 x 20
98
24.091200.20 Cover, Air Cleaner
99
23.091003.21 Element, Air Cleaner
100
23.0910 01.21 Separator, Air Cleaner
101
Coil, Ignition, Silicon Rubber, EPA
3
1
1
2
1
1
1
1
1
2
2
1
1
2
1
1
2
1
1
1
1
2
1
1
1
1
4
2
2
1
1
1
1
2
2
2
2
2
1
/
1
2
2
1
1
1
4
2
1
1
1
1
22
TROUBLESHOOTING
Problem Cause Solution
Generator will not start No fuel Add fuel
Faulty spark plug Replace spark plug
Unit loaded during start up Remove load from unit
Generator will not start; Generator starts but runs roughly
Generator shuts down during operation Out of fuel Fill fuel tank
Generator cannot supply enough power or overheating
No AC output Cable not properly connected Check all connections
Generator gallops Engine governor defective Contact the help line
Repeated circuit breaker tripping Overload Review load and adjust. See “Power
Low oil level Fill crankcase to the proper level
Place generator on a flat, level surface
Choke in the wrong position Adjust choke
Spark plug wire loose Attach wire to spark plug
Low oil level Fill crankcase to the proper level. Place
generator on a flat, level surface
Generator is overloaded Review load and adjust. See “Power
Management”
Insufficient ventilation Check for air restriction. Move to a well
ventilated area
Connected device is defective Replace defective device
Circuit breaker is open Reset circuit breaker
Faulty brush assembly Replace brush assembly (Service Center)
Faulty AVR (auto voltage regulator) Replace AVR (Service Center)
Loose wiring Inspect and tighten wiring connections
Other Contact the help line
Management”
Faulty cords or device Check for damaged, bare or frayed wires.
Replace defective device
ENGLISH 100212
For further technical support:
Technical Service
Mon – Fri 8:30 AM – 5:00 PM (PST/PDT) Toll Free: 1-877-338-0999 tech@championpowerequipment.com
23
100212 ENGLISH
WARRANTY
WARRANTY
CHAMPION POWER EQUIPMENT
2 YEAR LIMITED WARRANTY
Warranty Qualifications
Champion Power Equipment (CPE) will register this warranty upon receipt of your Warranty Registration Card and a copy of your sales receipt from one of CPE’s retail locations as proof of purchase. Please submit your warranty registration and your proof of purchase within ten (10) days of the date of purchase.
Repair/Replacement Warranty
CPE warrants to the original purchaser that the mechanical and electrical components will be free of defects in material and workmanship for a period of two years (parts and labor) from the original date of purchase (180 days (parts and labor) for commercial & industrial use). Transportation charges on product submitted for repair or replacement under this warranty are the sole responsibility of the purchaser. This warranty only applies to the original purchaser and is not transferable.
Do Not Return The Unit To The Place Of Purchase
Contact CPE’s Technical Service and CPE will troubleshoot any issue via phone or e-mail. If the problem is not corrected by this method, CPE will, at its option, authorize evaluation, repair or replacement of the defective part or component at a CPE Service Center. CPE will provide you with a case number for warranty service. Please keep it for future reference. Repairs or replacements without prior authorization, or at an unauthorized repair facility, will not be covered by this warranty.
Installation, Use and Maintenance Cont’d.
Normal maintenance such as spark plugs, air filters, adjustments, fuel system cleaning and obstruction due to buildup is not covered by this warranty.
Other Exclusions
This warranty excludes:
– Cosmetic defects such as paint, decals, etc. – Wear items such as filter elements, o-rings, etc. – Accessory parts such as starting batteries, and
storage covers.
– Failures due to acts of God and other force majeure
events beyond the manufacturer’s control.
– Problems caused by parts that are not original
Champion Power Equipment parts.
This warranty does not apply to generators used for prime power in place of a utility.
Limits of Implied Warranty and Consequential Damage
Champion Power Equipment disclaims any obligation to cover any loss of time, use of this product, freight, or any incidental or consequential claim by anyone from using this generator. THIS WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. A unit provided as an exchange will be subject to the warranty of the original unit. The length of the warranty governing the exchanged unit will remain calculated by reference to the purchase date of the original unit. This warranty gives you certain legal rights which may change from state to state. Your state may also have other rights you may be entitled to that are not listed within this warranty.
Contact Information
Warranty Exclusions
This warranty does not cover the following repairs and equipment:
Normal Wear
Generators need periodic parts and service to perform well. This warranty does not cover repair when normal use has exhausted the life of a part or the equipment as a whole.
Installation, Use and Maintenance
This warranty will not apply to parts and/or labor if this generator is deemed to have been misused, neglected, involved in an accident, abused, loaded beyond the generator’s limits, modified, installed improperly or connected incorrectly to any electrical component.
Address
Champion Power Equipment, Inc. Customer Service 12039 Smith Ave. Santa Fe Springs, CA 90670 www.championpowerequipment.com
Customer Service
Mon – Fri 8:30 AM – 5:00 PM (PST/PDT) Toll Free: 1-877-338-0999 info@championpowerequipment.com Fax no.: 1-562-236-9429
Technical Service
Mon – Fri 8:30 AM – 5:00 PM (PST/PDT) Toll Free: 1-877-338-0999 tech@championpowerequipment.com 24/7 Tech Support: 1-562-204-1188
24
Champion Power Equipment, Inc. (CPE),
United States Environment Protection Agency (U.S. EPA)
Emission Control System Warranty
Your Champion Power Equipment (CPE) engine complies with U.S. EPA emission regulations.
YOUR WARRANTY RIGHTS AND OBLIGATIONS:
The US EPA AND CPE are pleased to explain the Federal Emission Control Systems Warranty on your 2015 small off-road engine and engine powered equipment. New engines and equipment must be designed, built and equipped, at the time of sale, to meet U.S. EPA regulations for small no control system on your small off-road engine and equipment for the period of time listed below, provided there has been no abuse, neglect, unapproved modification, or improper maintenance of your equipment.
Your emission control system may include parts such as the carburetor, fuel-injection system, the ignition system, catalytic converter and fuel lines. Also included may be hoses, belts, connectors and other emission related assemblies. Where a warrantable condition exits, CPE will repair your small off including diagnosis, parts and labor.
MANUFACTURER’S EMISSION CONTROL SYSTEM WARRANTY COVERAGE:
This emission control system is warranted for two years, subject to provisions set forth below. If, during the warranty period, emission related part on your engine is defective in materials or workmanship, the part will be repaired or replaced by CPE.
OWNER WARRANTY RESPONSIBILITIES:
As the small off-road engine owner, you are responsible for the performance of the requ your Owner’s Manual. CPE recommends that you retain all your receipts covering maintenance on your small off­road engine, but CPE cannot deny warranty solely for the lack of receipts or for your failure to ensure the performance of all scheduled maintenance.
As the small off-road engine owner, you should however be aware that CPE may deny you warranty coverage if your small, off-road engine or a part has failed due to abuse, neglect, improper maintenance or unapproved modifications.
You ar service outlet as described in (3)(f.) below, CPE dealer or CPE, Santa Fe Springs, Ca. as soon as a problem exists. The warranty repairs should be completed in a reasonable amount of time, not to exceed 30 days.
If you have any questions regarding your warranty rights and responsibilities, you should contact:
e responsible for presenting your small off-road engine to an Authorized CPE service outlet or alternate
Champion Power Equipment, Inc.
Customer Service
12039 Smith Ave.
Santa Fe Springs, CA 90670
1-877-338-0999
tech@championpowerequipment.com
n-road engines. CPE warrants the emission
-road engine at no cost to you
ired maintenance listed in
EMISSION CONTROL SYSTEM WARRANTY
The following are specific provisions relative to your Emission Control System (ECS) Warranty Coverage.
1. APPLICABILITY: This warranty shall apply to 1997 and later model year small off-road engines. The ECS
Warranty Period shall begin on the date the new engine or equipment is delivered to its original, end-use purchaser, and shall continue for 24 consecutive months thereafter.
2. GENERAL EMISSIONS WARRANTY COVERAGE
CPE warrants to the original, end-use purchaser of the new engine or equipment and to each subsequent purchaser that each of its small off-road engines is: a. Designed, built and equipped so as to conform to U.S. EPA emissions standards for spark-ignited engines at or below 19 kilowatts. b. Free from defects in materials and workmanship that cause the failure of a warranted part to be identical in all material respects to the part as described in the engine manufacturer’s application for certification for a period of two years.
3. THE WARRANTY ON EMISSION-RELATED PARTS WILL BE INTERPRETED AS FOLLOWS:
a. Any warranted part that is not scheduled for replacement as required maintenance in the Owners Manual shall be warranted for the ECS Warranty Period. If any such part fails during the ECS Warranty Period, it shall be repaired or replaced by CPE according to Subsection “d” below. Any such part repaired or replaced under the ECS Warranty shall be warranted for any remainder of the ECS Warranty Period. b. Any warranted, emissions-related part which is scheduled only for regular inspection as specified in the Owners Manual shall be warranted for the ECS Warranty Period. A statement in such written instructions to the effect of “repair or replace as necessary”, shall not reduce the ECS Warranty Period. Any such part repaired or replaced under the ECS Warranty shall be warranted for the remainder of the ECS Warranty Period. c. Any warranted, emissions-related part which is scheduled for replacement as required maintenance in the Owner’s Manual shall be warranted for the period of time prior to the first scheduled replacement point for that part. If the part fails prior to the first scheduled replacement, the part shall be repaired or replaced by CPE according to Subsection “d” below. Any such emissions-related part repaired or replaced under the ECS Warranty, shall be warranted for the remainder of the ECS Warranty Period prior to the first scheduled replacement point for such emissions-related part. d. Repair or replacement of any warranted, emissions-related part under this ECS Warranty shall be performed at no charge to the owner at a CPE Authorized Service Outlet. e. The owner shall not be charged for diagnostic labor which leads to the determination that a part covered by the ECS Warranty is in fact defective, provided that such diagnostic work is performed at a CPE Authorized Service Outlet. f. CPE shall pay for covered emissions warranty repairs at non-authorized service outlets under the following circumstances: i. The service is required in a population center with a population over 100,000 according to U.S. Census 2000 without a CPE Authorized Service Outlet AND ii. The service is required more than 100 miles from a CPE Authorized Service Outlet. The 100 mile limitation does not apply in the following states: Alaska, Arizona, Colorado, Hawaii, Idaho, Montana, Nebraska, Nevada, New Mexico, Oregon, Texas, Utah and Wyoming. g. CPE shall be liable for damages to other original engine components or approved modifications proximately caused by a failure under warranty of an emission-related part covered by the ECS Warranty. h. Throughout the ECS Warranty Period, CPE shall maintain a supply of warranted emission-related parts sufficient to meet the expected demand for such emission-related parts. i. Any CPE Authorized and approved emission-related replacement part may be used in the performance of any ECS Warranty maintenance or repair and will be provided without charge to the owner. Such use shall not reduce CPE’s warranty obligation. j. Unapproved add-on or modified parts may not be used to modify or repair a CPE engine. Such use voids this ECS Warranty and shall be sufficient grounds for disallowing an ECS Warranty claim. CPE shall not be liable hereunder for failures of any warranted parts of a CPE engine caused by the use of such an unapproved add-on or modified part.
EMISSION-RELATED PARTS INCLUDE THE FOLLOWING: (using those portions of the list applicable to the engine)
Systems covered by this warranty
Parts Description
Fuel Metering System
Fuel regulator, Carburetor and internal parts
Air Induction System
Air cleaner, Intake manifold
Ignition System
Spark plug and parts, Magneto ignition system Exhaust System
Exhaust manifold, catalytic converter
Miscellaneous Parts
Tubing, Fittings, Seals, Gaskets, and Clamps associated with these listed systems.
Evaporative Emissions
Fuel Tank, Fuel Cap, Fuel Line, Fuel Line Fittings, Clamps, Pressure Relief Valves, Control Valves, Control Solenoids, Electronic Controls, Vacuum Control Diaphragms, Control Cables, Control Linkages, Purge Valves, Vapor Hoses, Liquid/Vapor Separator, Carbon Canister, Canister Mounting Brackets, Carburetor Purge Port Connector
TO OBTAIN WARRANTY SERVICE:
You must take your CPE engine or the product on which it is installed, along with your warranty registration card or other proof of original purchase date, at your expense, to any Champion Power Equipment dealer who is authorized by Champion Power Equipment, Inc. to sell and service that CPE product during his normal business hours. Alternate service locations defined in Section (3)(f.) above must be approved by CPE prior to service. Claims for repair or adjustment found to be caused solely by defects in material or workmanship will not be denied because the engine was not properly maintained and used.
If you have any questions regarding your warranty rights and responsibilities, or to obtain warranty service, please write or call Customer Service at Champion Power Equipment, Inc.
Champion Power Equipment, Inc.
12039 Smith Ave.
Santa Fe Springs, CA 90670
1-877-338-0999
Attn.: Customer Service
tech@championpowerequipment.com
Loading...