12.5 kW
HOME POWER
The Comfort of Home,
The Confi dence of Champion
Home Standby Generator
Model 100136 - 12.5kW Unit
Model 100176 - Unit with 100 AMP NEMA 1 ATS.
Model 100179 - Unit with 100 AMP NEMA 3 ATS.
Maximum Continuous Power LPG: 12.5 kW
Maximum Continuous Power NG: 11 kW
Rated Voltage: 240
Amps: 52 LPG/45.8 NG
Harmonic Distortion : Less than 5%
Unit Circuit Breaker: 50 AMP
Phase: Single
Frequency: 60 Hz
Unit Weight: 405 lbs
Size: 49 x 28 x 28 in.
Engine
Type: Milwaukee Series OHV Vtwin
No. of Cylinders: 2
Displacement: 717cc
Cylinder Block: Aluminum with cast iron sleeve
Ignition System: Solid State – Magneto
Governor: Mechanical
Starter: 24 volt
Oil Capacity: 1.4 qt – 1.3 L
RPM: 3,600
Your customers deserve the very best. Give them the reliability, service and support of a
Champion Home Standby Generator. Designed in the USA for the exacting standards of
the North American market, all Champion engine-powered products meet all California Air
Resource Board (CARB) regulations and Environmental Protection Agency (EPA) requirements
and are approved to Underwriters Laboratory (UL) certifi cations in both the USA and Canada.
Home Stand-by Power – 12.5 kW
Protection: Automatic 24/7 operation
Fuel: LPG or natural gas for continuous operation
Convenience: Auto start in the event of utility power failure. Automatic weekly exercise
and test function to insure the unit is always ready to perform
Quiet operation: Designed for residential installations
Innovative: “Gullwing” enclosure permits easy installation and service
Champion Home Standby units include:
■
12.5 kW continuous electrical power
■
717cc Champion OHV engine, electric start and low oil shutdown
■
Automatic 100 amp, 10 circuit transfer switch
■
Champion Auto Control Module (ACM)
■
All weather composite mounting pad
■
All weather steel enclosure
■
Natural gas or LPG operation
■
5 year limited warranty
■
100 percent reliable
Controls
Mode Switch Auto : Auto start on utility failure
Mode Switch Manual : Starts on demand
Mode Switch Off : Stops unit /control and charger active
Ready to Run / Maintenance Messages: Standard
Programmable Start Delay: Standard
Engine Start Sequence: Standard
Starter Lockout: Standard
Battery Charger / Low Battery Indicator: Standard
Charger Fault: Standard
AVR Over / Under Protection: Standard
Low Oil: Standard
Safety Fused: Standard
Overcrank / Overspeed protection: Standard
Transfer Switch
No. of Poles: 2
Rating: 100 AMP
Voltage Rating (VAC): 250
Return to Utility: 15 seconds
Exercise Weekly – 15 Minutes : Standard
UL Listed USA and Canada : Standard
Circuits: 12