Champion instruments Scepter III Getting Started Manual

TM
Scepter III
Data Collector
Champion Instruments ,LLC 678-386-2208 | http://www.championinstruments.com
Getting Started Guide
1. Physical Appearance
GPS Antenna
Touch Panel
Mini USB socket
Function Keys
Camera Key
Power Key
Microphone
Front
Reset Button
USB Cable Lock Nut
Back Strap Holder
Champion Instruments ,LLC 678-386-2208 | http://www.championinstruments.com
Bottom
1
Back strap holder
Speaker
External antenna connector
Camera
Lock Screw
Back cover
Back
Champion Instruments ,LLC
678-386-2208 |
2
http://www.championinstruments.com
2. Operating instructions
I. How to Charge the Scepter III
II. Inserting the TF (micro SD) card/SIM card/Battery
III. Turning the Scepter III on and off
IV. Connecting to PC to install an application or data
V. Collecting GIS data with internal GPS and GIS applications
I. How to Charge the Scepter III
Insert the Li-ion battery into the battery compartment to charge. Note that the mini USB cable can also be used to charge the receiver. During charging, if the receiver is on, there is a charging icon in the top right corner of the screen.
II. Inserting the TF (microSD) card/SIM card/Battery
1. Turn the back cover screw to the open position according to the instructions on the back
cover and take off the back cover ( Figure 1 )
2. Insert the SIM card and TF card according to the instructions on the battery compartment
( Figure 2 )
3. Insert the battery
4. Open the back cover and turn the screw to the lock position according to the instructions on
the back cover
instructions on the back cover
(Figure 1)
Counter clockwise rotation
Turning Lock
Figure 1
Figure 2
3
Champion Instruments ,LLC 678-386-2208 | http://www.championinstruments.com
III. Turning the Scepter III on and off
Make sure the battery has enough power; connect the receiver to your PC with a mini USB cable (battery inserted) Press Power button for 3~4 seconds to turn on (until the boot screen appears)/turn off. Please note that if the receiver is down, press the reset button in the bottom of the receiver to reset.
IV. Connecting to PC [to install an application or data]
1. Make sure Microsoft ActiveSync application has been installed (if PC OS is Win-XP). If PC OS is
Vista/Win7/Win8, make sure Windows Mobile Device Center has been installed.
2. Connect the receiver to your PC with mini USB cable.
3. ActiveSync application connects the receiver and your PC automatically. The icon appears in
the toolbar of the PC and 'Syncronization Set-up Wizard' appears meantime, click 'Cancel'
4. Click "Browse" to check the files in the receiver, then transfer data between your PC and
receiver using Windows cut, copy, and paste functions.
Installing Applications
1. Make sure the Scepter III is connected with your PC via ActiveSync
2. Click "Install file" on your PC to start the installation. If the install file is compatible for
mobile devices, copy the file into the Scepter III and click to start the installation
3. Select the installation directory in Scepter III (‘Flash Storage’ is suggested), click
‘Install’. Please note that it is suggested to install the application in ‘Flash Storage’, and save your data in the TF card
V. Collecting GIS data with internal GPS and GIS applications
Using the GPS
The GPS's physical port number is COM3, Baud Rate is 9600, and its virtual port number is COM5
1. Start -> File Explorer -> My Device -> GNSSViewer folder -> GNSSViewer
2. BoardSetup:
BoardType: Select other or uBlox if module is uBlox GPSPort: COM3 or COM5 BaudRate: 9600
3. Press OK, wait for the connection to see GPS positioning
Champion Instruments ,LLC 678-386-2208 | http://www.championinstruments.com
4
- Using the Camera
1. Select ‘Start->Picture & Video’select ‘Camera’ or camera icon to take photos. Click
screen and select ‘OK’ to exit
2. Press the camera key to take a photo. Click screen and select ‘OK’ to exit
Using a Wireless Connection (Bluetooth/GPRS/Wi-Fi) Bluetooth
1. Select ‘Start Settings Connections Wireless management’, click the right of
Bluetooth to activate the Bluetooth device.
2. Select ‘Start
SettingsBluetooth’, click ‘Add new device…’, system will search available
Bluetooth devices. Select the device in refurbished list and click ‘Next’ in the bottom right corner, then input password
3. Select ‘Next’, input password in external Bluetooth device and finish the connection. Please
note the password is used to the connection between Bluetooth devices and can be setup freely, e. ‘1234’
GRPS Connection Settings
1. Make sure there's a SIM card in the receiver
2. Select 'StartSettingsConnectionsConnections '
3. Click ‘Add a new modem connection’
4. Input connection name, select ‘Cellular Line (GPRS)’, click ‘Next’
5. Input broadband (for AT&T) as the APN ,then click ‘Next’
6. Click ‘Finish’ and add new connection successfully
7. Click ‘Manage existing connections’
8. Hold down on the new connection button and select
‘Connect’
9. If there is a GPRS identifier on the signal icon on the top right corner, it indicates a successful
Connection to Wi-Fi
1. Select 'Start
2. Click 'Search for Networks,' select a network that listed. Follow the installation guide to
input password and finish the connection.
Settings Connections Connections Wi-Fi
3. Useful Settings
Screen response
Select ‘StartSettingsSystemScreen’, click ‘Align Screen’ icon and follow the guide to align the screen
Adjust backlight
Select ‘StartSettingsSystemBacklight', adjust backlight status according to the guild
Champion Instruments ,LLC 678-386-2208 | http://www.championinstruments.com
5
Auto power off
Select ‘Start S
ettings System Power Advanced’, set the power off time
conditionally
Remove programs
Select ‘Start
Settings System Remove Programs’, select the program in the list and
click ‘OK’ to remove
Restore Factory Defaults
Select ‘Start Settings System Clean Boot, restore factory
defaults settings according to the guide Caution: All the data and
programs will be lost, If restore factory defaults setting
4. Environmental Specifications
Operating temperature: -10+ 60
Storage temperature: -30~+70
Drop: 1.2m drop onto all faces
Casing: Dustproof and resistant to heavy wind-driven rain per IP65 standard
Humidity: 5% ~ 95% (non-condensing)
Clean the display with a soft cloth, and be careful not to wipe the display with abrasive
chemicals of any kind. Do not expose your device to extreme heat(60℃) or cold (-10) For example, do not leave it in the trunk of your car exposed to high heat.
Do not attempt to open the device other than as instructed in this manual
Rough handling can break internal circuit structure
Do not use harsh chemicals, cleaning solvents, or strong detergents to clean the device.
Use only the recommended accessories.
Do not excessive sound pressure from earphones and headphones. Note that this can
cause hearing loss.
USB Data Cables
Insert the USB data cable connector into the USB interface of the Scepter III
Connect the other terminal of the USB data cable with the USB interface of your PC
This version supports a USB interface. You can connect your Scepter III with your PC via the
USB & Data cable. You can also copy or move the files to and from your Scepter III and PC, browse the images, or record files and video files saved in the Scepter III, accessed on your PC
Champion Instruments ,LLC 678-386-2208 | http://www.championinstruments.com
6
5. General Specifications
Size: 158mm x 85mm x 25mm
Physical
Battery
System
Weight: 290g (without battery)
350g (with battery)
Battery capacity of 3000mAh / 3.7V Voltage
8+ hours typical operational time
5 hours recharge time
Smart Battery System
Input at 5V DC, 500mA
Only use the specified Scepter III AC adapter
Actual time may vary, based on a variety of conditions
Windows Mobile 6.1/6.5
806MHz CPU / 256MB RAM
5.0MP Camera with AF
2G Flash storage / MicroSD max up to 8GB
3.7”VGA LCD with 480 x 640 resolution
Speaker and Mic
GPS
Performance
Communication
Enviroment
Regulatory
Professional GPS and GPS antenna
Support external GPS antenna
2-5m GPS accuracy*
TTFF: Cold Start < 50 seconds
Hot Start < 10 seconds
NMEA-0183 Protocol output
Bluetooth v2.0
WiFi connection
GSM/GPRS, 850/900/1800/1900MHz
Temperature: Operation: -20 to +60 Storage: -30 to +70
Waterproof: IP64
Drop: 1.2m height on to a concrete floor
FCC Part 15
CE
Champion Instruments ,LLC 678-386-2208 | http://www.championinstruments.com
7
CAUTION!
The connection to USB Interfaces has to be
6. Accessories
limited to USB 2.0 version or higher. The connection to "power use" is prohibited.
Item Picture ERP NO. Name Description Quantity
1
2
3
4
5
018-0011-0006
081-0000-0005 Strap Black 180*12mm
070-0000-0001 Stylus Black 127mm
009-0000-0056
010-0000-0002 USB Charger
Li-ion Battery 3.7V /3000 mAh
USB-MiniUSB
USB Cable
L=1500mm
USB Charger
No Cable
1
1
1
1
1
6
Champion Instruments ,LLC 678-386-2208 | http://www.championinstruments.com
079-0011-0006 Getting Started
Guide
5V/1A
A5
English
31 pages
1
8
7. Warranty Terms
The GIS Scepter III is guaranteed against defective material and workmanship under normal use and application consistent with this Manual. The equipment is guaranteed for the period indicated, on the warranty card accompanying the product, starting from the date that the product is sold to the original purchaser by Champion Instruments Authorized Dealers.
During the warranty period, Champion Instruments will, at its discrepancy, repair or replace this product at no additional charge. Repair parts and replacement products will be furnished on an exchange basis and will be either reconditioned or new.
The limited warranty does not include service to repair damage to the product resulting from an accident, disaster, misuses, abuse or modification of the product.
Warranty service may be obtained from an authorized Champion Instruments warranty service dealer. If this product is delivered by mail, purchaser agrees to insure the product or assume the risk of loss or damage in transit, to prepay shipping charges to the warranty service location, and to use the original shipping container or equivalent.
A letter should accompany the package furnishing a description of the problem and/ or defect.
The purchaser's sole remedy shall be replaces as provided above. In no event shall Champion Instruments be liable for any damages or any other claim including any claims for lost profits, lost savings, or other incidental or consequential damages arising out of the use of, or inability to use the product.
Champion Instruments ,LLC 678-386-2208 |
9
http://www.championinstruments.com
8. Appendix
Table of Contents:
I. Product Safety Warnings ( II. Pairing Device with Windows 8 PC via. Bluetooth III. Bluetooth Transfer from Scepter to PC via. Bluetooth IV. How to send files from PC to Scepter via. Bluetooth
Safety and Compliance
Information
)
I. Product Safety Warnings (Safety and Compliance
Information)
Use the Scepter III responsibility. Read all instructions and safety informations before use to avoid injury.
Battery safety
Charge battery using only a temperature ranging from 32ºF to 104ºF (0ºC to 40 º C)
CAUTION!
Danger of explosion if battery is incorrectly replaced.
Replace only with the same or equivalent type of battery recommended by the manufacturer.
The maximum operating ambient temperature of the switching power supply declared by the manufacturer is 50 degrees C, 122 degrees F
Dispose of used batteries according to battery manufacturer’s instructions.
Champion Instruments ,LLC
10
678-386-2208 | http://www.championinstruments.com
Wi-Fi safety
Turn Wi-Fi off in areas where Wi-Fi use is prohibited or when it may cause interference or danger. For example, flying on an airplane.
Care and Maintenance
The Scepter III is an electronic product and should be treated with care to reduce the risk of fire, electric shock, or product damage. Do not expose this device to rain, moisture, or any type of liquid that corrodes electronic circuits. If your device gets wet, immediately power off. Allow the device to dry completely before using it again.
II. Pairing device with Windows 8 PC via. Blue-tooth
Step 1:
Before you begin, go into your Scepter III's settings by clicking on the START menu on the top left. Then select SETTINGS. Select the CONNECTIONS tab on the bottom of the SETTINGS menu. Select the BLUETOOTH icon. Then, click on the MODE tab on the bottom. Check BOTH boxes here. This way, our Bluetooth is not only turned on, but visible to other devices that would like to connect. After both boxes are checked, you are ready to connect from your PC. Hit OK at the top right.
Now let's begin the pairing on your PC.
Champion Instruments ,LLC 678-386-2208 | http://www.championinstruments.com
11
Step 2:
If Bluetooth icon is not visible on bottom right of your home screen, select the SHOW HIDDEN ICONS arrow to reveal the shortcut.
Step 3:
Select Bluetooth Devices to display Properties.
Step 4:
Select "Show Bluetooth Devices"
Champion Instruments ,LLC
12
678-386-2208 | http://www.championinstruments.com
Step 5:
Manage Bluetooth devices will now popup and you will identify which device is your Data Collector. It appears as GeoHT_Rec, and the note indicates that the unit is ready to pair. Highlight it to select it.
Step 6:
Pair will appear.
Select it.
Step 7:
Once Pair is selected, Windows will generate a random passcode (the one shown is just an example, yours will be different) for you to enter onto the Scepter device. If you do not get this entered within a minute or two, Windows will automatically assume the process failed and generate a new passcode to enter.
13
Champion Instruments ,LLC 678-386-2208 |
http://www.championinstruments.com
Step 8:
Your Scepter will alert you that a device wants to connect, and you will have to select YES. (In this case, the computers name is APOLLO, but the computer name should be displayed as whatever it has been called in its initial setup.)
Step 9:
In the box, enter the pass-code that Windows provided you with earlier, and then press NEXT.
Step 10:
Your PC will now indicate that you are PAIRED with your Scepter. Once paired, this connection will be retained. Future connections should be automatic with this service.
14
Champion Instruments ,LLC 678-386-2208 | http://www.championinstruments.com
III. Bluetooth Transfer from Scepter to PC via. Bluetooth
Step 1:
Before beginning, please see document entitled “Pairing device with Windows 8 PC via Bluetooth” to make sure you have made your Scepter visible, and are connected to your PC. Once connection is successfully established, proceed to step 2.
Step 3:
Type “cmd” into the Search Bar, and then hit ENTER. This will open your computer’s Command Prompt.
Step 2:
On your Windows 8 PC keyboard, simultaneously hold down the WINDOWS key and press Q to automatically pull up your Search Bar.
Champion Instruments ,LLC 678-386-2208 | http://www.championinstruments.com
15
Step 4:
When your Command Prompt opens, type in the command “fsquirt” and then hit ENTER.
Step 5:
A window will then pop up asking if you’d like to SEND or RECEIVE via Bluetooth Connection. Select RECEIVE.
Champion Instruments ,LLC 678-386-2208 |
16
http://www.championinstruments.com
Step 6:
The window will then tell you that your computer is waiting for a connection. At this point, we will move over to the Scepter to select the file to copy.
Step 7:
On your Scepter home screen, select the START menu, and choose FILE EXPLORER. Once there, search to the file you are going to send, and hold your stylus on it until the following menu pops up. Select BEAM FILE.
Champion Instruments ,LLC 678-386-2208 | http://www.championinstruments.com
17
Step 8
After BEAM FILE is selected, you are prompted to pick which connected Blue-tooth device you would like to copy it to. In this case, the computer in the example is named APOLLO, but your computer will show up as whatever you have named it in your initial Windows 8 setup. Select the corresponding TAP TO SEND.
:
Step 9:
You will then see the file being transferred from the Scepter to your Computer. This file is being copied, not moved. So this file will be on both the computer and the Scepter.
Champion Instruments ,LLC 678-386-2208 | http://www.championinstruments.com
18
Step 10:
Lastly, you will need to browse to the location on your computer where you would like the copied file to go. After a file path is established, hit FINISH. You have now successfully copied a file from your Scepter to your computer using Bluetooth instead of cabled connection.
IV: How to send files from PC to Scepter via. Bluetooth
Step 1:
Before beginning, please see document entitled “Pairing device with Windows 8 PC via Bluetooth” to make sure you have made your data collector visible and you are connected to your PC. Once connection is successfully established, proceed to step 2.
Champion Instruments ,LLC 678-386-2208 | http://www.championinstruments.com
19
Step 2:
On your Windows 8 PC keyboard, simultaneously hold down the WINDOWS and press Q to pull up your Search Bar.
Step 3:
Type "cmd" in the search bar and hit enter, which will open your computer's command prompt.
Step 4:
When your command prompt opens, type in "fsquirt" and press enter.
20
Champion Instruments ,LLC 678-386-2208 | http://www.championinstruments.com
Step 5:
A window will then pop up asking if you'd like to send or receive via bluetooth connection. Select SEND.
Step 6:
You will then be prompted to choose which paired device you would like to send file to. Select the device from the list and hit NEXT.
Champion Instruments ,LLC
21
678-386-2208 | http://www.championinstruments.com
Step 7:
You will then be prompted to browse your computer to find the file you wish to send. Hit Browse, and navigate to where the file is on your PC that you’d like to transfer. Select it and NEXT.
Step 8
Now you will see the a popup on your Scepter that first tells you that you are Receiving Data, then it will ask you if you want to save to your device. Select YES.
:
Champion Instruments ,LLC 678-386-2208 |
22
http://www.championinstruments.com
Step 9:
You will see on the computer that the file has been Successfully Transferred. Select FINISH.
Step 10:
NOTE: All files sent to the Scepter will go to My Documents folder by default. To locate them, simply go to the START menu on your Scepter, select FILE EXPLORER, select MY DOCUMENTS, and scroll down until you see it. To move to another location, hold your stylus on the file until a menu pops up, and select COPY. Then navigate to the desired location, select MENU at the bottom, select EDIT, then PASTE. You will then see your file in the new location. You can then delete from its original location in MY DOCUMENTS by returning to that folder, holding your stylus on the file, and selecting DELETE.
Champion Instruments ,LLC 678-386-2208 |
23
http://www.championinstruments.com
Should you need additional assistance, please contact your local distributor. Champion Instruments at 678-386-2208, or visit the Champion Instruments website at
http:///www.championinstruments.com
Champion Instruments ,LLC 678-386-2208 | http://www.championinstruments.com
24
Notes:
25
Notes:
2
6
Loading...