STANDARD FEATURES
EUCCW SERIES UPRIGHT CONVEYORS
Project Item No. Quantity
ENERGY STAR® Qualified (EUCCW6 & EUCCW8 only)
• Exclusive Dual Rinse Technology
• All-purpose 29" wide peg belt
• Dish capacities up to 19,140 dishes per hour (NSF Certified)
• Automatic tank fill
• Chemical dispensing equipment connection provisions
• Common hot water connection
• Common drain connection
• Common electric connection (separate connection required for optional electric booster and blower-dryer)
• One piece stainless steel wash/rinse manifold system, easy to remove
• Door safety switch
• Electric eye energy sentinel (idle pump shut-off)
• Easy-to-reach top-mounted controls
• Heavy-gauge stainless construction
• Low-water tank heat protection
• Push-button start-stop station – load end
• Recirculating flushing nozzles – load end with prewash
• Rinse saver device
• Conveyor shut-off shelf – unload end
• Stainless steel enclosure panels – front & ends
• Vent fan control connection provided
OPTIONAL WORLD CLASS FEATURES
Heat Recovery – redirects lost steam to heat using less energy
EUCCW SERIES
Upright 29" Conveyor
Dual Rinse Dishwashing Machine
Photo is for general visual representation only. Please refer to specifications for the latest detailed product information.
SPECIFIER STATEMENT
Specified unit will be Champion model EUCCW4, EUCCW6 or EUCCW8 upright 29" conveyor water saver dishwashing machine.
Features automatic tank fill, chemical dispensing connection provisions, common water, drain and electrical connections, door safety switch, low water tank heat protection, rinse saver.
1 year parts and labor warranty.
The DualRinse feature offers the
Lowest Water/Utility/Chemical Consumption
as low as 57 GPH usage while circulating
as much as 400 gallons of water for
Consistently Good Results
2674 N. Service Road, Jordan Station, Ontario, Canada L0R 1S0 Tel: 905-562-4195 Fax: 905/562-4618
(pdf) 8/15
CH104
Champion Industries, Inc.
3765 Champion Boulevard, Winston-Salem, NC 27105 Tel:
336/661-1556 Fax: 336/661-1979
www.championindustries.com
Champion, an Ali Group Company
EUCCW SERIES
Upright 29" Conveyor Dual Rinse Dishwashing Machine
MODULAR SECTIONS: Right to Left Operation
EUCCW4
18-5/8"
[473]
39" [991]
CL
2
12" [305]
4' [1219]
4B
9'-4" CL-CL
[2845]
Overall Length “C”
5'-8"
[1727]
31-1/2"
[800]
Minimum For Screen Removal
Dimensions shown in inches and [millimeters]
[559]
1
4A
3
CL
29" [737]
Clearance
6" [152]
37-1/4"
[946]
6-1/4" [159]
Plumbing Clearance
2'-1" [635]
1'-10"
“B”
Unload
4" [102]
4B
7" [178] 7" [178]
1/2 HP
36" [914]
10-1/2" [266]
2
TABLE A - Machine Connection
Machine Only - Electric Heat
Maximum
Overcurrent
Protective
Device
Elec.
Specs.
Rated Amps
Minimum
Supply Ckt.
Conductor
Ampacity
208/60/3 171 200 200
240/60/3 149 175 175
480/60/3 74 90 90
TABLE B - Booster Connection
40°F/22°C Rise – 10kW Electric Built-in Booster
Maximum
Overcurrent
Protective
Device
Elec.
Specs.
Rated Amps
Minimum
Supply Ckt.
Conductor
Ampacity
208/60/3 28 35 35
240/60/3 36 30 30
480/60/3 12 15 15
4' [1219]
Wash
2'
[610]
Dual
Rinse
0.2
3
HP
5-1/2"
1
[140]
Wash
Machine-steam
Minimum
Supply Ckt.
Elec.
Specs.
Rated Amps
Conductor
Ampacity
208/60/3 21 25 25
240/60/3 18 25 25
480/60/3 10 15 15
70°F/39°C Rise - 18kW Electric Built-in Booster
Minimum
Supply Ckt.
Elec.
Specs.
Rated Amps
Conductor
Ampacity
208/60/3 50 70 70
240/60/3 43 60 60
480/60/3 22 30 30
Contact Factory for additional voltages.
2'-6"
[762]
Prewash
“A”
Load
4" [102]
4A
1
HPHP
1-5/8" [41]
Maximum
Overcurrent
Protective
Device
Maximum
Overcurrent
Protective
Device
12" [305] Plumbing Clearance
100" [2540]
19" [483]
Clear
3
Door
Removal
95" [2413]
Doors Up
38"
[965]
62" [1575]
Machine Height
Start/Stop
Notes:
Load Section (A) Standard 5',
contains 30" Prewash
Prewash also available in a
48" HD section
Non-standard load section
available in 12" increments
Minimum load length 5'
(includes 30" prewash)
Unload Section (B) Standard
5 ft contains 24" Aux.
Rinse and 36" belt, available
in 12" increments
Built in electric booster requires
a 5' minimum unload
Built in steam booster requires
a minimum 6' unload
Blow dryer section adds 4' to
overall length of machine
Due to an ongoing value analysis program at Champion, specifications contained in this catalog are subject to change without notice.
Champion Industries, Inc., 3765 Champion Boulevard, Winston-Salem, NC 27105 • 336/661-1556 • Fax: 336/661-1979 • www.championindustries.com
2674 N. Service Road, Jordan Station, Ontario, Canada L0R 1S0 • 905/562-4195 • Fax: 905/562-4618
EUCCW SERIES
Upright 29" Conveyor Dual Rinse Dishwashing Machine
MODULAR SECTIONS: Right to Left Operation
Dimensions shown in inches and [millimeters]
EUCCW6
18-5/8"
[473]
39" [991]
CL
2
1/2 HP
36" [914]
4'
[1219]
12" [305]
7" [178]
“B”
Unload
4B
4B
4"
[102]
2'
[610]
Rinse
0.2
HP
Overall Length “C”
6' [1829]
Wash/Rinse
3'
[914]
Power
Rinse
3
HP
11'-4" CL-CL
[3454]
3'
[914]
5-1/2"
1
[140]
Wash
3
HP
5'-8"
[1727]
31-1/2"
[800]
Minimum For Screen Removal
“A”
Load
2'-6"
[762]
PrewashDual
4"
[102]
1
HP
2'-1"
[635]
1'-10"
[559]
4A
7" [178]
1
4A
3
6" [152]
CL
29" Clear
[737]
6-1/4" [159]
19" [483] Clear
38"
[965]
3
37-1/4"
[946]
12" [305] Plumbing Clearance
100" [2540]
Door
Removal
95" [2413] Doors Up
62" [1575]
Machine
Height
Plumbing Clearance
10-1/2"
2
[266]
TABLE A - Machine Connection
Machine Only - Electric Heat
Maximum
Overcurrent
Protective
Elec.
Specs.
Rated Amps
Minimum
Supply Ckt.
Conductor
Ampacity
208/60/3 183 250 250
240/60/3 158 200 200
480/60/3 80 100 100
Device
Machine-steam
Maximum
Overcurrent
Protective
Device
Elec.
Specs.
Rated Amps
Minimum
Supply Ckt.
Conductor
Ampacity
208/60/3 29 40 40
240/60/3 26 35 35
480/60/3 14 20 20
1-5/8"
[41]
Start/Stop
Notes:
Load Section (A) Standard 5',
contains 30" Prewash
Prewash also available in a
48" HD section
Non-standard load section
available in 12" increments
Minimum load length 5'
(includes 30" prewash)
Unload Section (B) Standard
TABLE B - Booster Connection
40°F/22°C Rise – 10kW Electric Built-in Booster
Maximum
Overcurrent
Protective
Device
Elec.
Specs.
Rated Amps
Minimum
Supply Ckt.
Conductor
Ampacity
208/60/3 28 35 35
240/60/3 36 30 30
480/60/3 12 15 15
70°F/39°C Rise - 18kW Electric Built-in Booster
Maximum
Overcurrent
Protective
Device
Elec.
Specs.
Rated Amps
Minimum
Supply Ckt.
Conductor
Ampacity
208/60/3 50 70 70
240/60/3 43 60 60
480/60/3 22 30 30
Contact Factory for additional voltages.
Due to an ongoing value analysis program at Champion, specifications contained in this catalog are subject to change without notice.
Champion Industries, Inc., 3765 Champion Boulevard, Winston-Salem, NC 27105 • 336/661-1556 • Fax: 336/661-1979 • www.championindustries.com
2674 N. Service Road, Jordan Station, Ontario, Canada L0R 1S0 • 905/562-4195 • Fax: 905/562-4618
5 ft contains 24" Aux.
Rinse and 36" belt, available
in 12" increments
Built in electric booster requires
a 5' minimum unload
Built in steam booster requires
a minimum 6' unload
Blow dryer section adds 4' to
overall length of machine
EUCCW SERIES
Upright 29" Conveyor Dual Rinse Dishwashing Machine
MODULAR SECTIONS: Right to Left Operation
Dimensions shown in inches and [millimeters]
EUCCW8
18-5/8"
[473]
CL
39" [991]
2
1/2 HP
36" [914]
12" [305]
4' [1219]
Unload
7" [178]
“B”
4" [102] 4B
4B
Overall Length “C”
2'
[610] [1219] [1219]
Dual
Rinse
0.2HP3
HP
4'
Power
Rinse
13'-4" CL-CL
[4064]
8' [2438]
Wash/Rinse
5'-8"
[1727]
31-1/2"
[800]
Minimum For Screen Removal
4'
5-1/2"
1
3
HP
[140]
Wash
2'-6"
[762]
Prewash
“A”
Load
1
HP
[102]
4"
2'-1"
[635]
1'-10"
[559]
4A
7" [178]
1
4A
3
6" [152]
CL
29" [737]
Clear
6-1/4" [159]
Plumbing Clearance
19" [483]
3
Clear
38"
[965]
100" [2540]
95" [2413]
62" [1575]
37-1/4"
[946]
12" [305]
Door
Removal
Doors Up
Machine
Height
Plumbing Clearance
10-1/2" [266]
2
TABLE A - Machine Connection
Machine Only - Electric Heat
Maximum
Overcurrent
Protective
Elec.
Specs.
Rated Amps
Minimum
Supply Ckt.
Conductor
Ampacity
208/60/3 183 250 250
240/60/3 158 200 200
480/60/3 80 100 100
Device
Machine-steam
Maximum
Overcurrent
Protective
Device
Elec.
Specs.
Rated
Amps
Minimum
Supply Ckt.
Conductor
Ampacity
208/60/3 29 40 40
240/60/3 26 35 35
480/60/3 14 20 20
1-5/8"
[41]
Start/Stop
Notes:
Load Section (A) Standard 5',
contains 30" Prewash
Prewash also available in a
48" HD section
Non-standard load section
available in 12" increments
Minimum load length 5'
(includes 30" prewash)
Unload Section (B) Standard
TABLE B - Booster Connection
40°F/22°C Rise – 18kW Electric Built-in Booster
Maximum
Overcurrent
Protective
Device
Elec.
Specs.
Rated Amps
Minimum
Supply Ckt.
Conductor
Ampacity
208/60/3 50 70 70
240/60/3 43 60 60
480/60/3 22 30 30
70°F/39°C Rise - 32kW Electric Built-in Booster
Maximum
Overcurrent
Protective
Device
Elec.
Specs.
Rated
Amps
Minimum
Supply Ckt.
Conductor
Ampacity
208/60/3 89 125 125
240/60/3 77 100 100
480/60/3 39 50 50
Contact Factory for additional voltages.
Due to an ongoing value analysis program at Champion, specifications contained in this catalog are subject to change without notice.
Champion Industries, Inc., 3765 Champion Boulevard, Winston-Salem, NC 27105 • 336/661-1556 • Fax: 336/661-1979 • www.championindustries.com
2674 N. Service Road, Jordan Station, Ontario, Canada L0R 1S0 • 905/562-4195 • Fax: 905/562-4618
5 ft contains 24" Aux.
Rinse and 36" belt, available
in 12" increments
Built in electric booster requires
a 5' minimum unload
Built in steam booster requires
a minimum 6' unload
Blow dryer section adds 4' to
overall length of machine
EUCCW SERIES
Upright 29" Conveyor
Dual Rinse
Dishwashing Machine
Shipping weight crated: 150 lbs./ft.[68kg./m.] Height with doors up: 95" Height to remove doors: 100"
SPECIFICATIONS
Ca pacities EUCCW4 EUCCW6 EUCCW8
Dishes per hr. (NSF rated) 9,965 13,445 19,140 Conveyor speed (ft./min.) 6.3 8.5 12.1
Motor horsepower
Drive 1/2 Hp 1/2 Hp 1/2 Hp Prewash 30" [762] 1 Hp 1 Hp 1 Hp Prewash 48" [1219] 3 Hp 3 Hp 3 Hp Wash 3 Hp 3 Hp 3 Hp Power Rinse* N/A 3 Hp 3 Hp Auxiliary Rinse 1/5 Hp 1/5 Hp 1/5 Hp
Water consumption
Gal. per hr. (max. use) 58 57 158
Temperatures °F
Wash (min.) 160 150 150 Power Rinse (min.)* N/A 160 160 Auxiliary Rinse (min.) 165 165 165 Final rinse (min.) 180 180 180
Heating
Tank heat Steam Electric
Wash tank 125 lbs./hr. 25 kW Wash tank (EUCCW4) 225 lbs./hr. 45 kW Rinse tank * 100 lbs./hr. 20 kW Auxiliary rinse 50 lbs./hr. 10 kW
Electric booster 10 10 18
(kW required for 40°F rise)
Electric booster 18 18 32
(kW required for 70°F rise)
Steam booster 50 50 90
(lbs./hr. required for 40°F rise)
Steam booster 90 90 150
(lbs./hr. required for 70°F rise)
Venting
Minimum CFM, load end 300 Minimum CFM, unload end 800
*EUCCW4 has no power rinse tank
Utilities EUCCW4
1
Electrical Connection
A Machine connection (see table A) B Booster connection (see table A)
2
Hot Water
3/4" NPT 180°F hot water connection. (For machine without built-in booster)
3
Drain
2" NPT connection, 62 gpm max flow rate
4
Vents
A Load end: 300 CFM 1/4" S.P. B Unload end: 800 CFM 1/4" S.P. With blower-dryer,
increase room ventilation by 600 CFM.
Utilities EUCCW6
1
Electrical Connection
Contact factory for specific machine electrical requirements NOTE: Electric booster connection – contact Factory
2
Hot Water
3/4" NPT 180°F hot water connection. (For machine without built-in booster)
3
Drain
2" NPT connection, 62 gpm max flow rate
4
Vents
A Load end: 300 CFM 1/4" S.P. B Unload end: 800 CFM 1/4" S.P. With blower-dryer,
increase room ventilation by 600 CFM.
Utilities EUCCW8
1
Electrical Connection
Contact factory for specific machine electrical requirements NOTE: Electric booster connection – contact Factory
2
Hot Water
3/4" NPT 180°F hot water connection. (For machine without built-in booster)
3
Drain
2" NPT connection, 62 gpm max flow rate
4
Vents
A Load end: 300 CFM 1/4" S.P. B Unload end: 800 CFM 1/4" S.P. With blower-dryer,
increase room ventilation by 600 CFM.
Booster connections may vary. Contact the Factory.
Standard Voltages (Specify choice): 208/60/3, 240/60/3, and
480/60/3. Available in 3-phase only. For non-standard 3-phase voltages, contact the Factory.
Plumbing Notes Because of the variation in house-supplied water
pressure, a water pressure regulating valve (PRV) is needed (water PRV is standard with a booster). Steam PRV’s may be required for pressure higher than 30 psi. The PRVs can either be purchased from Champion or obtained locally.
Due to an ongoing value analysis program at Champion, specifications contained in this catalog are subject to change without notice.
Champion Industries, Inc., 3765 Champion Boulevard, Winston-Salem, NC 27105 • 336/661-1556 • Fax: 336/661-1979 • www.championindustries.com
2674 N. Service Road, Jordan Station, Ontario, Canada L0R 1S0 • 905/562-4195 • Fax: 905/562-4618
Warning Plumbing and electrical connections should be made by
qualified personnel who will observe all the applicable plumbing, sanitary, safety codes and the National Electrical Code.
Note Water Hammer Arrestor (meeting ASSE-1010 standard or
equivalent) to be supplied (by others) in common water supply line at service connection.
Venting Notes
Fabricated duct size: 3-7/8" x 23-7/8" (outside dimensions)
Champion, an Ali Group Company
EUCCW SERIES
Upright 29" Conveyor Dual Rinse Dishwashing Machine
Control Panel Digital Gauges
OPTIONS & ACCESSORIES
□ Tank heat; choices of electric, steam coil or
steam injectors
EUCCW SERIES UPRIGHT CONVEYOR
□ Booster Heaters – stainless steel
(completely inter-plumbed, controls are inter-wired)
□ Electric: (40°F rise or 70°F rise)
□ Steam: (40°F or 70°F rise)
□ 48" Blower Dryer, electric or steam (add 4' to
overall length)
□ Belts: standard peg belt, flat belt, thermal tray
belt, silverware belt, belts with upper cross rods, and other select combination belts
□ Start/Stop station, unload end
□ Back panels, stainless steel
□ Cold water thermostat (for pre-wash)
□ External scrap bucket on 48" pre-wash
(standard on 30" pre-wash)
□ External scrap bucket on wash tank
□ Insulated hoods, lower panels
□ Motor pumps, 2 or 3 Hp optional in lieu of 1 Hp
on pre-wash
□ Bumper rail, machine mounted
□ Steam pressure regulating valve (unmounted
□ Drain water tempering kit (mounted)
□ Insulated hinged door
Heat Recovery –
Redirects lost steam to heat using less energy.
Heated 110°F water travels back to booster
Water leaves
booster at
180°F+
and travels to
nal rinse arms
□ Shock arrestor (water)
□ Drain interlocks
□ Heat Recovery Unit redirects lost steam to
heat using less energy
Booster
60°F incoming water
to machine.
Due to an ongoing value analysis program at Champion, specifications contained in this catalog are subject to change without notice.
Champion Industries, Inc., 3765 Champion Boulevard, Winston-Salem, NC 27105 • 336/661-1556 • Fax: 336/661-1979 • www.championindustries.com
2674 N. Service Road, Jordan Station, Ontario, Canada L0R 1S0 • 905/562-4195 • Fax: 905/562-4618
Loading...