Project
Item No.
Quantity
GENESIS HOOD-TYPE
STANDARD FEATURES
• ENERGY STAR® Qualified
• NEW Exclusive Built-in booster configured
for both 40° and 70° Rise
• Rinse Sentry – ensures 180°F final rinse
• Auto start – starts unit when hood is closed
• High efficiency 1 HP pump
• Up to 53 racks per hour
• Self draining pump
• Automatic tank fill
• Detergent/chemical connections
• Interchangeable upper and lower spray arm
• Automatic drain valve – drains wash tank when
power is off
• Vent fan control
• Bottom mounted digital controls
• PRV (Pressure Reducing Valve)
• Sloped hood keeps hot vapors away from operator
• Standard and Heavy Duty wash cycles
Gas
Genesis
DH5000 Single Source Gas
Hood-type Dishwashing Machine
OPTIONS & ACCESSORIES
: Drain Water Tempering Kit
: Direct Vent Option with Fan
: Racks
: Peg
: Flat
: Door Interlock
: Corner Operation Splash Baffle
(1M) 12/14 Printed in U.S.A.
Photo is for general visual representation
only. Please refer to specifications for the
latest detailed product information.
SPECIFIER STATEMENT
Specified unit will be Champion model Genesis, DH5000
single source gas hood-type dishwashing machine.
Features sloped hood, electronic controls, Rinse Sentry,
Auto start, interchangeable stainless steel wash and rinse
arms, up to 53 racks/hr., 0.83 US gals/rack.
1 year parts and labor warranty.
Champion Industries, Inc.
3765 Champion Blvd., Winston-Salem, NC 27105
Tel: 336/661-1556 Fax: 336/661-1979
www.championindustries.com
GENESIS
25-5/16
"
25-5/8
"
27-1/2
"
34-1/8
"
5-3/4
"
44-5/8
"
41
"
6-3/8
"
24-5/8
"
20-3/4
"
8-1/4
"
Gas Booster
25-5/16
"
25-5/8
"
27-1/2
"
34-1/8
"
5-3/4
"
10
"
44-5/8
"
41
"
6-3/8
"
24-5/8
"
20-3/4
"
8-1/4
"
3-1/4
"
Gas Booster
DH5000 Single Source Gas
Hood-type Dishwashing Machine
Shipping weight crated: 300 lbs.
GENESIS HOOD-TYPE
25-5/8
Utilities
1 Electrical
Machine Connection (See Electrical Box)
Gas Booster Connection 15 AMPs
120V/60/1
2 Hot Water
3/4" NPT Hot Water 140°F for 40°F Rise
3/4" NPT Hot Water 110°F for 70°F Rise
20-22 PSI Flow pressure
3 Drain
2" OD Machine Drain Connection
3/4" NPT Relief Valve to Open Drain
1/2" NPT Vent to Open Drain
4 Natural Gas
40°F Rise Requires 58,000BTU/hr
70°F Rise Requires 105,000BTU/hr
PMG-60 Requires 1/2" NPT
PMG-100 Requires 3/4" NPT
See Gas Piping Note
5 Gas Flue Exhaust
See Gas Flue Ventilation Note
4" Diameter Rear of Booster
6 Exhaust
250 CFM Hood Required
"
10-1/2
Gas Booster
"
24-5/8
"
8-1/4
20-3/4
"
3-1/4
10-1/2
"
17
"
"
"
69-3/4
"
6-3/8
5-3/4
27-1/2
44-5/8
"
"
"
41
"
31-3/8
"
"
25-7/16
"
19-5/8
"
10-1/4
Plan View
"
10
Warning: Plumbing, electrical connections
should be made by qualified personnel who will
observe all the applicable plumbing, sanitary and
safety codes and the National Electrical Code.
Minimum
Voltage
Rated
Amps
Ampacity
208-240/60/1 15 20 20
208-240/60/3 8 15 15
460-480/60/3 4 15 15
"
8-1/2
Supply
Circuit
Gas Booster
"
34-1/8
"
7-1/8
Front ViewSide View
"
Maximum
Overcurrent
Protective
Device
Dimensions shown in inches and [mm]
"
3-1/2
29-1/2
"
19-5/8
26-1/8
"
6
"
60-1/8
"
6
"
Typical Table Construction
SPECIFICATIONS
Capacities
Racks per hr. (NSF rated) 53
Wash tank (gal.) 9.5
Motor horsepower
Water consumption
Gal. per hr. (max. use) 44
Gal. per rack 0.83
Temperature °F
Wash 150
Rinse 180
Gas Heating
PMG-60 (40°F rise) 58,000 BTU/hr
PMG-100 (70°F rise) 105,000 BTU/hr
Time cycle in seconds
Standard Extended
Wash 35 65
Rinse 10 10
Sanitary Dwell 15 15
Total cycle 60 90
1 HP
Due to an ongoing value analysis program at Champion, specifications contained in this catalog are subject to change without notice.
Champion Industries, Inc., 3765 Champion Blvd., NC 27105 • 336/661-1556 • Fax: 336/661-1979 • www.championindustries.com
‘USGBC’ and related logo is a trademark owned by the U.S. Green Building Council and is used by permission.