Champion AVA70, ADA50, ADA35, ASA35, ASA50 Specification

...
ADVANTAGE
CHAMPION RESIDENTIAL UL TRACOOL
RESIDENTIAL
ADA 50 Down Discharge
AIR COOLERS
ASA 35
Side Discharge
AUA 70
Up Discharge
ADA35 ASA35
ADA50 ASA50 AUA50
ADA5012 ASA5012
ADA70 ASA70 AUA70
ADA7012 ASA7012
22 9/16
28
28
5
34
/8
5
34
/8
34
42
42
42
42
40
45
49
48
52
13 5/8
3
17
17
3/4
3
19
3
19
WATER
SERVICE
LOCATION
K L
17
17
17
5
14
/8
14 1/16
1
18
/16
12
16
16
187
130
17 15/16
22
12
/8
/8
43
1
46
179
16
16
3/4
3/4
1
1
52
57 51
52
252
272
192
18
22
1/4
1/4
26
26
3/4
3/4
32
25 25
25
7/8
7
/8
3/16
7/8
19 19
23
12
1/16
1
/16
3/4
1/16
1
3
3/4
10 3/16
7
1
/8
1
1
1/2
12
/4
/8
1
1/2
12
1/8
13 5/8
17
/4
17
14 7/16
13
17
1
5
/4
5
3/4
5
3/4
20
20
24
3/8
3/8
3
/8
/2
3
9/16
3
9/16
5
1
1
7
57
1
3
19
/4
/4
3
19
/4
/4
1
1
/2
11
/8
1
1
1
/2
11
/8
13
17
3
5
/4
3
5
/4
20
24
9
3
3
/16
/8
9
3
3
/16
/8
17
17
14 1/16
18 1/16
20
20
16
16
3
/4
1
64
294
215
18 67 67
3
/4
64
1
321
235
22
3
1
29
/4
/4
3
1
29
/4
/4
28 28
35
28
7/8 7/8
3/16
7
/8
19 19
12
23
1/16
1
/16
3/4
1
/16
67
*All dimensions in inches.
ADA/ASA
35
ADA/ASA/
AUA
50
ADA/ASA
5012
3/4 H.P. requires a 53" belt.
3000 3500
4000 4400 5000
4000 4400 5000
ADA/ASA/
AUA
70
ADA/ASA
7012
5400 6000 7000
5400 6000 7000
1
/3
1 OR 2
1
/2
1
1 OR 2
/3
1
/2
3
/4
1
1 OR 2
/3
1
/2
3
/4
1
/2
1 OR 2
3
/4
1
1
/2
1 OR 2
3
/4
1
1
1
1
1
1
115
115
115
115
115
8.3
10.9
8.3
10.9
14.9
8.3
10.9
14.9
10.9
14.9
17.1
10.9
14.9
17.1
2022 2315
2873 3321 3788
2750 3149 3606
3987 4564 5024
3922 4488 4941
1871 2178
2650 3110 3630
2566 2993 3472
3750 4350 4820
3685 4279 4747
1738 2061
2390 2910 3450
2323 2803 3317
3510 4130 4630
3462 4087 4572
1607 1947
2060 2650 3260
1997 2564 3135
3270 3940 4450
3212 3888 4394
1470 1834
1806 2400 3020
1629 2266 2918
3055 3730 4280
2898 3662 4208
1311 1714
1600 2130 2806
1313 1944 2661
2610 3580 4100
2471 3392 3996
1107 1581
1370 1940 2570
1039 1648 2379
2210 3180 3900
2002 3049 3749
*All dimensions in inches. **Motors shipped separately. ***Blower motor (high speed) and pumps. ****Cubic feet per minute.
CFM ratings are based on test data to AMCA (Air Movement and Control Association) standard 210 by an independent AMCA approved laboratory.
OPTIONAL THERMOSTAT
SELECTING AN
ACCESSORY
CHAMPION RESIDENTIAL ULTRACOOL
ULTRACOOL COOLER
1.
Consult zone map to
nd correct zone.
2.
Consult table below to nd correct "Minutes per Air Change" for your zone.
3.
Determine area to be cooled in cubic feet (building length x width x height).
4.
Divide cubic feet (step 3) by minutes per air change (step 2) to determine Cubic Feet per Minute (CFM).
5.
Select the correct Champion Cooler model in the data table on the previous page according to CFM and expected static pressure. If CFM falls between models, choose the larger model.
ST ANDARD FEATURES
Large LED readout is easy to read
Easy 4-wire hook up makes installation quick and simple
Durable rain-proof control box ensures safety
Thermostat controlled dump cycle adds
convenience
Dump cycle control is compatible with any pump!
Two-stage operation provides better comfort and even
temperatures
Easy to program and operate
C ontact your local Champion dealer today for
more information on why an UltraC ool Advantage
Evaporative Cooler should be your First C hoice.
Only C hoice.
• INTERIOR HEAT LOAD: High means places with unusual heat sources
from hot equipment or processes, crowded conditions, etc. Normal means no unusual heat sources - typical home or oce.
• EXTERIOR HEAT LOAD: Exposed means walls, roof exposed to sun,
poor insulations, etc. Insulated means walls and roof well insulated and/or shaded.
EXAMPLE – A house in Phoenix, AZ, 40 feet long by 30 feet wide
with 8-foot ceiling. Well insulated, no unusual heat sources.
1.
30 x 40 x 8 = 9,600 cubic feet
2.
Zone 2
3.
Minutes per Air Change = 3
4.
®
9,600 ÷ 3 = 3,200 CFM
5.
Referring to CFM table inside this brochure, cooler model ADA50 with a 3/4 h.p. motor is indicated, assuming a typical static pressure of .2" W.G.
Designed with You in Mind!
Crafted With Pride In The USA
5800 Murray, Little Rock, AR 72209 800-643-8341 www.championcooler.com
Catalog No. CUCB-Sept. 2005
Loading...