Walk-in Rackwasher
1536-B
1536-B RACKWASHER
Due to an ongoing value analysis program at Champion, specifications contained in this catalog are subject to change without notice.
Champion Industries, Inc., P. O. Box 4149, Winston-Salem, NC 27115 • 336/661-1556 • Fax: 336/661-1979 • www.championindustries.com
SPECIFICATIONS
Door
Double skinned, STAINLESS STEEL hinged door
design with exterior latch and inside release handle.
Recirculating Wash Tank
STAINLESS STEEL with electric, infrared gas, live
steam or steam coil heating, thermostatically
controlled, low water protected, sloped to drain with a
75 gallon capacity (67 gallons if infrared gas heated).
Rinse Tank
STAINLESS STEEL with electric, infrared gas or
steam coil booster heater to provide 180°/190° hot
sanitizing rinse. Uses 12 gallons per 30 second cycle.
Filter
Perforated, STAINLESS STEEL screen type. Double
filtration system for increased effectiveness and easy
cleaning without emptying the tank.
Spray Arm Assembly
STAINLESS STEEL spray arm assembly with
STAINLESS STEEL jets, removable end caps and
hand operated quick release mechanism for easy
cleaning and reassembly.
Water Pump
15 H.P., 208/240 or 480 volt, 3 phase, 60 cycle with
output of 250 gallons per minute at 35 to 45 P.S.I.
Digital Control & Information Center
110 volt control circuit with push pad operation of
“POWER ON”, “STOP” and “SHORT, MEDIUM or
LONG WASH CYCLES”. A digital display indicates
“TIME REMAINING” for each cycle. LED’s indicate
wash, rinse and unload functions. A buzzer is also
included to provide an audible indication of time to
unload. A programmable controller allows the push pad
to be used as a “DIAGNOSTIC CENTER” by displaying
“ERROR CODES” for ease of troubleshooting.
Gauges
Moisture resistant gauges measure Wash
Temperature, Wash Pressure and Rinse Temperature.
Racks
STAINLESS STEEL built to match specific washing
requirements
Warning: Plumbing and electrical connection should be made by qualified
personnel who will observe all the applicable plumbing, sanitary and safety
codes and the National Electrical Code.
Note: Water Hammer Arrestor (meeting ASSE-1010 standard or equivalent) to
be supplied (by others) in common water supply line at service connection.
Dimensions shown in inches and [millimeters]