Chamberlain Elite 3585S 3/4 HP, Elite Series Security+ 3585S 3/4HP Owner's Manual

Page 1
®
GARAGE DOOR OPENER
Model 3585S 3/4 HP
For Residential Use Only
The Chamberlain Group, Inc.
845 Larch Avenue
Elmhurst, Illinois 60126-1196
www.liftmaster.com
Owner’s Manual
Fasten the manual near the garage door after installation.
The door WILL NOT CLOSE unless the Protector System
Periodic checks of the opener are required to ensure safe operation.
The model number label is located under the light lens on the left side panel of your opener.
®
is connected and properly aligned.
Page 2

TABLE OF CONTENTS

Introduction 2-5
Safety symbol and signal word review . . . . . . . . . . . . . . . 2
Preparing your garage door . . . . . . . . . . . . . . . . . . . . . . . 3
Tools needed. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Planning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Carton inventory . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Hardware inventory. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Assembly 6-7
Attach the rail to the motor unit . . . . . . . . . . . . . . . . . . . .6
Set the belt tension . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Attach the belt cap retainer . . . . . . . . . . . . . . . . . . . . . . . . 7
Installation 7-23
Installation safety instructions . . . . . . . . . . . . . . . . . . . . . 7
Determine the header bracket location . . . . . . . . . . . . . . . 8
Install the header bracket . . . . . . . . . . . . . . . . . . . . . . . . . 9
Attach the rail to the header bracket . . . . . . . . . . . . . . . .10
Position the opener. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Hang the opener . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Install the door control . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Install the light . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14
Attach the emergency release rope and handle. . . . . . . . 14
Electrical requirements . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Install the Protector System
Fasten the door bracket. . . . . . . . . . . . . . . . . . . . . . . 20-21
Connect the door arm to the trolley . . . . . . . . . . . . . 22-23
®
. . . . . . . . . . . . . . . . . . 16-19
Adjustment 24-26
Adjust the UP and DOWN travel limits . . . . . . . . . . . . . . 24
Adjust the force. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Test the safety reversal system. . . . . . . . . . . . . . . . . . . . 26
Test the Protector System
®
. . . . . . . . . . . . . . . . . . . . . . . 26
Operation 27-33
Operation safety instructions . . . . . . . . . . . . . . . . . . . . . 27
Using your garage door opener . . . . . . . . . . . . . . . . . . . 27
Using the wall-mounted door control . . . . . . . . . . . . . . . 28
Using the remote control . . . . . . . . . . . . . . . . . . . . . . . . 29
To open the door manually . . . . . . . . . . . . . . . . . . . . . . . 30
Care of your opener . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
Having a problem? . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
Diagnostic chart . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
Smart Control Panel
®
messages . . . . . . . . . . . . . . . . . . . 33
Programming 34-35
To add or reprogram a hand-held remote control. . . . . . 34
To erase all codes from motor unit memory. . . . . . . . . . 34
3-Button remotes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
To add, reprogram or change a Keyless Entry PIN . . . . . 35
Repair Parts 36-37
Rail assembly parts. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
Installation parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .36
Motor unit assembly parts . . . . . . . . . . . . . . . . . . . . . . . 37
Accessories 38
Notes 39
Repair Parts and Service 40
Warranty 40

INTRODUCTION

Safety Symbol and Signal Word Review

This garage door opener has been designed and tested to offer safe service provided it is installed, operated, maintained and tested in strict accordance with the instructions and warnings contained in this manual.
When you see these Safety Symbols and Signal Words on the following pages, they will alert you to the possibility
Mechanical
Electrical
of serious injury or death if you do not comply with the warnings that accompany them. The hazard may come from something mechanical or from electric shock. Read the warnings carefully.
When you see this Signal Word on the following pages, it will alert you to the possibility of damage to your garage door and/or the garage door opener if you do not comply with the cautionary statements that accompany it. Read them carefully.
2
Page 3

Preparing your garage door

Before you begin:
• Disable locks.
• Remove any ropes connected to garage door.
Complete the following test to make sure your garage
door is balanced and is not sticking or binding:
1. Lift the door about halfway as shown. Release the door. If balanced, it should stay in place, supported entirely by its springs.
2. Raise and lower the door to see if there is any binding or sticking.
If your door binds, sticks, or is out of balance, call a trained door systems technician.
SECTIONAL DOOR
To prevent possible SERIOUS INJURY or DEATH:
• ALWAYS call a trained door systems technician if garage door binds, sticks, or is out of balance. An unbalanced garage door may NOT reverse when required.
• NEVER try to loosen, move or adjust garage door, door springs, cables, pulleys, brackets or their hardware, ALL of which are under EXTREME tension.
• Disable ALL locks and remove ALL ropes connected to garage door BEFORE installing and operating garage door opener to avoid entanglement.
To prevent damage to garage door and opener:
• ALWAYS disable locks BEFORE installing and operating the opener.
• ONLY operate garage door opener at 120V, 60 Hz to avoid malfunction and damage.
Carpenter’s Level (optional)
Stepladder
ONE-PIECE DOOR
Drill
1/2" and 7/16" Sockets and Wrench
Tape Measure
3/16", 5/16" and 5/32" Drill Bits
3

Tools needed

During assembly, installation and adjustment of the opener, instructions will call for hand tools as illustrated below.
Pencil
Hack Saw
Wire Cutters
Claw Hammer
Pliers
Screwdriver
Adjustable End Wrench
Page 4

Planning

Identify the type and height of your garage door. Survey your garage area to see if any of the conditions below apply to your installation. Additional materials may be required. You may fi nd it helpful to refer back to this page and the accompanying illustrations as you proceed with the installation of your opener.
Horizontal and vertical reinforcement is needed for lightweight garage doors (fi berglass, steel, aluminum, door with glass panels, etc.). See page 20 for details.
Header Wall
FINISHED CEILING
Support bracket & fastening hardware is required. See page 12.
Vertical Centerline of Door
Gap between fl oor and
Safety Reversing Sensor
bottom of door must not exceed 1/4" (6 mm).
ONE-PIECE DOOR WITHOUT TRACK
Header Wall
Torsion Spring
OR
Safety Reversing Sensor
FINISHED CEILING
Support bracket & fastening hardware is required. See page 12.
Extension Spring
Access
Door
Wall-mounted Door Control
Motor unit
Motor unit
ONE-PIECE DOOR WITH TRACK
Safety Reversing Sensor
Wall-mounted Door Control
Safety
Reversing Sensor Gap between fl oor and bottom of door must not exceed 1/4" (6 mm).
Access
Door
Access
Door
Safety
Safety Reversing Sensor
Gap between fl oor and bottom of door must not exceed 1/4" (6 mm).
Reversing Sensor
4
Page 5

Carton Inventory

Your garage door opener is packaged in two cartons which contain the motor unit and all parts illustrated below. Accessories will depend on the model purchased.
®
Trolley
Smart Control Panel
2-Conductor Bell Wire White & White/Red
SECURITY 3-Button Remote Control Model 373P (1)
®
Motor Unit with Light Lenses
If anything is missing, carefully check the packing material. Parts may be stuck in the foam. Hardware for installation is also listed below.
Remote Control Visor Clip
Header Bracket
Styrofoam
Belt
One-Piece Rail
Curved Door Arm Section
Belt Cap Retainer
Door Bracket
Belt Pulley Bracket
Safety Reversing Sensor Bracket (2)
INSTALLATION HARDWARE
Hex Bolt 5/16"-18x7/8" (4)
Hex Screw #8 x 3/8" (2)
Lag Screw 5/16"-9x1-5/8" (2)
Lag Screw 5/16"-18x1-7/8" (2)
Clevis Pin 5/16"x2-3/4" (1)
Clevis Pin 5/16"x1-1/4" (1)
Clevis Pin 5/16"x1" (1)
Nut 5/16"-18 (4)
Lock Washer 5/16" (4)
Screw 6ABx1-1/4" (2)
The Protector System (2) Safety Reversing Sensors (1 Sending Eye and 1 Receiving Eye) with 2-Conductor White & White/Black Bell Wire attached
®
Self-Threading Screw 1/4"-14x5/8" (2)
Screw 6-32x1" (2)
Insulated Staples (30)
Ring Fastener (3)
Drywall Anchors (2)
Rope
Handle
Carriage Bolt 1/4"-20x1/2" (2)
Wing Nut 1/4"-20 (2)
5
Straight Door Arm Section
Safety Labels
and
Literature
Page 6
ASSEMBLY STEP 1

Attach the Rail to the Motor Unit

To avoid installation diffi culties, do not run the garage door opener until instructed to do so.
• Remove the bolt and lock nut from the top of the motor unit.
• Place rail onto the bolt mounted on the motor unit and align the back hole with the hole in the top of the unit.
• Fasten rail with the washered bolt and lock nut previously removed. Tighten securely. Remember
to use only these bolts/fasteners! Any other bolts/ fasteners will cause serious damage to the opener.
• Cut tape from rail, belt and styrofoam.
• REMOVE STYROFOAM.
• Position belt over the motor unit sprocket.
ASSEMBLY STEP 2

Set the Belt Tension

• By hand, thread the spring trolley nut on the threaded shaft until it is fi nger tight against the trolley (Figure 1). Do not use any tools.
• Insert a screwdriver tip into one of the nut ring slots and brace it fi rmly against the trolley (Figure 2).
• Place a 7/16" open end wrench on the square end. Rotate about 1/4 turn until the spring releases and snaps the nut ring against the trolley (Figure 3).
This extends the spring for optimum belt tension.
To avoid SERIOUS damage to opener, ONLY use bolts/ fasteners mounted in top of motor unit.
Washered Bolt
Lock Nut
Rail Hole
Motor Unit
Sprocket
Spring/Trolley Nut
5/16"-18x1/2"
Styrofoam
Trolley Threaded Shaft
Figure 1
Trolley Trolley
BEFORE
1" (2.5 cm)
Nut Ring Nut Ring
Figure 3
AFTER RELEASE 1-1/4" (3.18 cm)
Trolley Threaded Shaft
Nut Ring
Square End
Nut Ring Slots
Figure 2
6
Page 7
ASSEMBLY STEP 3
WARNING
WARNING
WARNING WARNING

Attach the Belt Cap Retainer

• Position the belt cap retainer over the motor unit
sprocket so the two holes in cap align with the two holes in mounting plate. Attach with 8x3/8" hex screws provided.
To avoid possible SERIOUS INJURY to fi ngers from moving garage door opener:
• ALWAYS keep hand clear of sprocket while operating opener.
• Securely attach sprocket cover BEFORE operating.
You have now fi nished assembling your garage door opener. Please read the following warnings before proceeding to the installation section.
HARDWARE SHOWN
ACTUAL SIZE
Hex Screw #8x3/8"
Hex Screws 8x3/8"
Belt Cap Retainer
Motor Unit Sprocket

INSTALLATION

IMPORTANT INSTALLATION INSTRUCTIONS
Mounting Plate
To reduce the risk of SEVERE INJURY or DEATH:
1. READ AND FOLLOW ALL INSTALLATION WARNINGS AND INSTRUCTIONS.
2. Install garage door opener ONLY on properly balanced and lubricated garage door. An improperly balanced door may NOT reverse when required and could result in SEVERE INJURY or DEATH.
3. ALL repairs to cables, spring assemblies and other hardware MUST be made by a trained door systems technician BEFORE installing opener.
4. Disable ALL locks and remove ALL ropes connected to garage door BEFORE installing opener to avoid entanglement.
5. Install garage door opener 7 feet (2.13 m) or more above fl oor.
6. Mount emergency release handle 6 feet (1.83 m) above fl oor.
7. NEVER connect garage door opener to power source until instructed to do so.
8. NEVER wear watches, rings or loose clothing while installing or servicing opener. They could be caught in garage door or opener mechanisms.
9. Install wall-mounted garage door control:
• within sight of the garage door.
• out of reach of children at minimum height
of 5 feet (1.5 m).
• away from ALL moving parts of the door.
10. Place entrapment warning label on wall next to garage door control.
11. Place manual release/safety reverse test label in plain view on inside of garage door.
12. Upon completion of installation, test safety reversal system. Door MUST reverse on contact with a 1-1/2" (3.8 cm) high object (or a 2x4 laid fl at) on the fl oor.
7
Page 8
INSTALLATION STEP 1

Determine the Header Bracket Location

To prevent possible SERIOUS INJURY or DEATH:
• Header bracket MUST be RIGIDLY fastened to structural support on header wall or ceiling, otherwise garage door might NOT reverse when required. DO NOT install header bracket over drywall.
• Concrete anchors MUST be used if mounting header bracket or 2x4 into masonry.
• NEVER try to loosen, move or adjust garage door, springs, cables, pulleys, brackets, or their hardware, ALL of which are under EXTREME tension.
• ALWAYS call a trained door systems technician if garage door binds, sticks, or is out of balance. An unbalanced garage door might NOT reverse when required.
Installation procedures vary according to garage door types. Follow the instructions which apply to your door.
1. Close the door and mark the inside vertical centerline of the garage door.
2. Extend the line onto the header wall above the door.
You can fasten the header bracket within 4'
(1.22 m) of the left or right of the door center only if a torsion spring or center bearing plate is in the way; or you can attach it to the ceiling (see page 9) when clearance is minimal. (It may be mounted on the wall upside down if necessary, to gain approximately 1/2" (1 cm)).
If you need to install the header bracket on a 2x4
(on wall or ceiling), use lag screws (not provided) to securely fasten the 2x4 to structural supports as shown here and on page 9.
3. Open your door to the highest point of travel as shown. Draw an inter secting horizontal line on the header wall above the high point:
• 2" (5 cm) above the high point for sectional door
and one-piece door with track.
• 8" (20 cm) above the high point for one-piece door
without track.
This height will provide travel clearance for the top edge
of the door.
NOTE: If the total number of inches exceeds the height
available in your garage, use the maximum height possible, or refer to page 9 for ceiling installation.
Header Wall
Header Wall
Highest Point of Travel
Door
Sectional door with
curved track
Door
Jamb Hardware
Unfi nished Ceiling
Vertical Centerline of Garage Door
Level (optional)
2" (5 cm)
Track
Header Wall
8" (20 cm)
Highest Point of Travel
2x4
2x4
Door
One-piece door with
horizontal track
Header Wall
Door
OPTIONAL CEILING MOUNT FOR HEADER BRACKET
Structural Supports
Header Wall
2" (5 cm)
Track
Highest Point of Travel
8" (20 cm)
Highest Point of Travel
Pivot
One-piece door without track:
jamb hardware
8
One-piece door without track:
pivot hardware
Page 9
INSTALLATION STEP 2

Install the Header Bracket

You can attach the header bracket either to the wall above the garage door, or to the ceiling. Follow the instructions which will work best for your particular requirements. Do
not install the header bracket over drywall. If installing into masonry, use concrete anchors (not provided).
WALL HEADER BRACKET INSTALLATION
• Center the bracket on the vertical centerline with the bottom edge of the bracket on the horizontal line as shown (with the arrow pointing toward the ceiling).
• Mark the vertical set of bracket holes (do not use the holes designated for ceiling mount). Drill 3/16" pilot holes and fasten the bracket securely to a structural support with the hardware provided.
HARDWARE SHOWN ACTUAL SIZE
Lag Screw 5/16"-9x1-5/8"
CEILING HEADER BRACKET INSTALLATION
• Extend the vertical centerline onto the ceiling as shown.
• Center the bracket on the vertical mark, no more than 6" (15 cm) from the wall. Make sure the arrow is pointing toward the wall. The bracket can be mounted fl ush against the ceiling when clearance is minimal.
• Mark the side holes. Drill 3/16" pilot holes and fasten bracket securely to a structural support with the hardware provided.
Wall Mounting Holes
Header Wall
2x4 Structural Support
Horizontal Line
Highest Point of Garage Door Travel
Optional
Mounting Holes
Header Bracket
Finished Ceiling
Header Bracket
The nail hole is for positioning only. You must use lag screws to mount the header bracket.
Vertical Centerline of Garage Door
Lag Screws 5/16"-9 x1-5/8"
Door Spring
Garage Door
Vertical Centerline of Garage Door
Vertical Centerline of Garage Door
Ceiling Mounting Holes
The nail hole is for positioning only. You must use lag screws to mount the header bracket.
9
6" (15 cm) Maximum
Door Spring
Garage Door
Lag Screws 5/16"-9x1-5/8"
Header Wall
Vertical Centerline of Garage Door
Page 10
Header Wall
Header Bracket
Belt Pulley Bracket
INSTALLATION STEP 3

Attach the Rail to the Header Bracket

• Position the opener on the garage fl oor below the header bracket. Use packing material as a protective base. NOTE: If the door spring is in the way you’ll need
help. Have someone hold the opener securely on a temporary support to allow the rail to clear the spring.
• Position the rail bracket against the header bracket.
• Align the bracket holes and join with a clevis pin as shown.
• Insert a ring fastener to secure.
Garage Door
Clevis Pin 5/16"x2-3/4"
Header Bracket
Belt Pulley Bracket
Ring Fastener
Rail
Temporary Support
Clevis Pin 5/16"x2-3/4"
HARDWARE SHOWN ACTUAL SIZE
Ring Fastener
10
Page 11
INSTALLATION STEP 4

Position the Opener

Follow instructions which apply to your door type as illustrated.
SECTIONAL DOOR OR ONE-PIECE DOOR WITH TRACK
A 2x4 laid fl at is convenient for setting an ideal door-to-rail distance.
• Remove foam packaging.
• Raise the opener onto a stepladder. You will need help at this point if the ladder is not tall enough.
• Open the door all the way and place a 2x4 laid fl at on the top section beneath the rail.
• If the top section or panel hits the trolley when you raise the door, pull down on the trolley release arm to disconnect inner and outer sections. Slide the outer trolley toward the motor unit. The trolley can remain disconnected until Installation Step 12 is completed.
Trolley Release Arm
ENGAGED RELEASED
ONE-PIECE DOOR WITHOUT TRACK
A 2x4 on its side is convenient for setting an ideal door-to-rail distance.
• Remove foam packaging.
• Raise the opener onto a stepladder. You will need help at this point if the ladder is not tall enough.
• Open the door all the way and place a 2x4 on its side on the top section of the door beneath the rail.
• The top of the door should be level with the top of the motor unit. Do not position the opener more than 4" (10 cm) above this point.
To prevent damage to garage door, rest garage door opener rail on 2x4 placed on top section of door.
Rail
Door
Header Bracket
Top of Door
2x4 is used to determine the correct mounting height from ceiling.
Top of Motor Unit
2x4 is used to determine the correct mounting height from ceiling.
11
Page 12
INSTALLATION STEP 5

Hang the Opener

Three representative installations are shown. Yours may be different. Hanging brackets should be angled (Figure 1) to provide rigid support. On fi nished ceilings (Figure 2 and Figure 3), attach a sturdy metal bracket to structural supports before installing the opener. This bracket and fastening hardware are not provided.
1. Measure the distance from each side of the motor unit to the structural support.
2. Cut both pieces of the hanging bracket to required lengths.
3. Drill 3/16" pilot holes in the structural supports.
4. Attach one end of each bracket to a support with 5/16"-18x1-7/8" lag screws.
5. Fasten the opener to the hanging brackets with 5/16"-18x7/8" hex bolts, lock washers and nuts.
6. Check to make sure the rail is centered over the door (or in line with the header bracket if the bracket is not centered above the door).
7. Remove the 2x4. Operate the door manually. If the door hits the rail, raise the header bracket.
NOTE: DO NOT connect power to opener at this time.
HARDWARE SHOWN ACTUAL SIZE
To avoid possible SERIOUS INJURY from a falling garage door opener, fasten it SECURELY to structural supports of the garage. Concrete anchors MUST be used if installing ANY brackets into masonry.
Figure 1
Measure Distance
Bolt 5/16"-18x7/8" Lock Washer 5/16" Nut 5/16"-18
Figure 2
Bracket (Not Provided)
Hidden Support
Structural Supports
Lag Screws 5/16"-18x1-7/8"
FINISHED CEILING
Lag Screws 5/16"-18x1-7/8"
(Not Provided) Bolt 5/16"-18x7/8" Lock Washer 5/16" Nut 5/16"-18
Lag Screw 5/16"-18x1-7/8"
Hex Bolt 5/16"-18x7/8"
Lock Washer 5/16"Nut 5/16"-18
Bolt 5/16"-18x7/8" Lock Washer 5/16" Nut 5/16"-18
Figure 3
Lag Screws 5/16"-18x1-7/8"
Bolt 5/16"-18x7/8" Lock Washer 5/16" Nut 5/16"-18
12
FINISHED CEILING
(Not Provided) Bolt 5/16"-18x7/8" Lock Washer 5/16" Nut 5/16"-18
Page 13
INSTALLATION STEP 6

Install the Door Control

Locate door control within sight of door, at a minimum height of 5' (1.5 m) where small children cannot reach, away from moving parts of door and door hardware. If installing into drywall, drill 5/32" holes and use the anchors provided. For pre-wired installations (as in new home construction), it may be mounted to a single gang box (Figure 1).
NOTE: The functional temperature range of the door control is between -4° F (-20° C) and 122° F (50° C). Scroll speed of display is slower at lower temperatures although the door control remains fully functional.
CAUTION: Continuous exposure of the door control to temperatures below -22° F (-30° C) may damage the LCD screen.
SPECIAL NOTE: Only one 398LM can be connected to each garage door opener. If additional wall controls are desired to operate the same garage door opener, it is recommended to use model 378LM wireless wall control as the secondary control console.
1. Strip 7/16" (11 mm) of insulation from one end of bell wire and connect to the two screw terminals on back of door control by color: white wire to the W (2) and white/red wire to the R (1) (Figure 2).
2. Remove push bar cover by gently prying at the lower/ middle portion of the cover with a small fl at-head screwdriver (Figure 1). Fasten with 6AB x 1-1/4" self-tapping screws (drywall installation) or 6-32 x 1" machine screws (into gang box) as follows:
• Install bottom screw, allowing 1/8" (3 mm) to
protrude above wall surface.
• Position bottom of door control on screw head and
slide down to secure. Adjust screw for snug fi t.
• Drill and install top screw with care to avoid cracking
plastic housing. DO NOT overtighten.
• Replace cover by inserting top tabs fi rst and then
snap cover in place (Figure 1).
3. (For standard installations ONLY) Run bell wire up wall and across ceiling to motor unit. Use insulated staples to secure wire in several places. DO NOT pierce wire with a staple, creating a short or open circuit.
4. Strip 7/16" (11 mm) of insulation from end of bell wire. Connect bell wire to the quick-connect terminals on the motor unit: white to white and white/red to red (Figure 2). To release or insert wire, push in tab with screwdriver tip.
NOTE: If you have any trouble with the operation of the buttons, loosen the top mounting screw. DO NOT connect power and operate the opener at this time. The trolley will travel to the full open position but will not return to the close position until the sensor beam is connected and properly aligned.
To prevent possible SERIOUS INJURY or DEATH from electrocution:
• Be sure power is NOT connected BEFORE installing door control.
• Connect ONLY to 24 VOLT low voltage wires.
To prevent possible SERIOUS INJURY or DEATH from a closing garage door:
• Install door control within sight of garage door, out of reach of children at a minimum height of 5 feet (1.5 m), and away from ALL moving parts of door.
• NEVER permit children to operate or play with door control push buttons or remote control transmitters.
• Activate door ONLY when it can be seen clearly, is properly adjusted, and there are no obstructions to door travel.
• ALWAYS keep garage door in sight until completely closed. NEVER permit anyone to cross path of closing garage door.
HARDWARE SHOWN ACTUAL SIZE
Screw 6ABx1-1/4" (Standard Installation)
Screw 6-32x1" (pre-wired)
Figure 1
PRE-WIRED INSTALLATION
REMOVE COVER
Figure 2
2-Conductor Bell Wire
(BACK VIEW)
Door Control Connections
Strip wire 7/16”
Lock Button
Door Control Terminal Screws
24 Volt Bell Wire
Push Bar
Light Button
Insulated Staples
Drywall Anchors
REPLACE COVER
To Replace Insert Top Tabs First
Push Bar Cover
Quick-Connect Terminals
To release or insert wire, push in tab with screwdriver tip
GreyWhiteRed
Antenna
13
Page 14
INSTALLATION STEP 7

Install the Light

• Press the release tabs on both sides of lens. Gently rotate lens back and downward until the lens hinge is in the fully open position. Do not remove the lens.
• Install a 100 watt maximum light bulb in each socket. Light bulb size should be A19, standard neck only. The lights will turn ON and remain lit for approximately 4-1/2 minutes when power is connected. Then the lights will turn OFF.
• Reverse the procedure to close the lens.
• Use A19, standard neck garage door opener bulbs for replacement.
NOTE: Use only standard light bulbs. The use of short neck or speciality light bulbs may overheat the endpanel or light socket.
To prevent possible OVERHEATING of the endpanel or light socket:
• DO NOT use short neck or specialty light bulbs.
• DO NOT use halogen bulbs. Use ONLY incandescent.
To prevent damage to the opener:
• DO NOT use bulbs larger than 100W.
• ONLY use A19 size bulbs.
100 Watt (Max) Standard Light Bulb
Release Tab
INSTALLATION STEP 8

Attach the Emergency Release Rope and Handle

• Thread one end of the rope through the hole in the top of the red handle so “NOTICE” reads right side up as shown. Secure with an overhand knot at least 1" (2.5 cm) from the end of the rope to prevent slipping.
• Thread the other end of the rope through the hole in the release arm of the outer trolley.
• Adjust rope length so the handle is 6' (1.83 m) above the fl oor. Ensure that the rope and handle clear the tops of all vehicles to avoid entanglement. Secure with an overhand knot.
NOTE: If it is necessary to cut the rope, heat seal the cut end with a match or lighter to prevent unraveling.
100 Watt
(Max)
Standard
Light Bulb
Lens Hinge
To prevent possible SERIOUS INJURY or DEATH from a falling garage door:
• If possible, use emergency release handle to disengage trolley ONLY when garage door is CLOSED. Weak or broken springs or unbalanced door could result in an open door falling rapidly and/ or unexpectedly.
• NEVER use emergency release handle unless garage doorway is clear of persons and obstructions.
• NEVER use handle to pull door open or closed. If rope knot becomes untied, you could fall.
Overhand Knot
Trolley Release Arm
Emergency Release
Handle
Overhand Knot
Rope
14
Page 15
INSTALLATION STEP 9

Electrical Requirements

To avoid installation diffi culties, do not run the opener at this time.
To reduce the risk of electric shock, your garage door opener has a grounding type plug with a third grounding pin. This plug will only fi t into a grounding type outlet. If the plug doesn’t fi t into the outlet you have, contact a qualifi ed electrician to install the proper outlet.
RIGHT WRONG
If permanent wiring is required by your local code, refer to the following procedure.
To make a permanent connection through the 7/8" hole in the top of the motor unit:
• Remove the motor unit cover screws and set the cover aside.
• Remove the attached 3-prong cord.
• Connect the black (line) wire to the screw on the brass terminal; the white (neutral) wire to the screw on the silver terminal; and the ground wire to the green ground screw. The opener must be grounded.
• Reinstall the cover.
To avoid installation diffi culties, do not run the opener at this time.
To prevent possible SERIOUS INJURY or DEATH from electrocution or fi re:
• Be sure power is NOT connected to the opener, and disconnect power to circuit BEFORE removing cover to establish permanent wiring connection.
• Garage door installation and wiring MUST be in compliance with ALL local electrical and building codes.
• NEVER use an extension cord, 2-wire adapter, or change plug in ANY way to make it fi t outlet. Be sure the opener is grounded.
PERMANENT WIRING CONNECTION
Ground Tab
Green Ground Screw
Ground Wire
White Wire
White Wire
Black Wire
Black Wire
15
Page 16
INSTALLATION STEP 10
Install The Protector System
The safety reversing sensor must be connected and aligned correctly before the garage door opener will move in the down direction.
IMPORTANT INFORMATION ABOUT THE SAFETY REVERSING SENSOR
When properly connected and aligned, the sensor will detect an obstacle in the path of its electronic beam. The sending eye (with an amber indicator light) transmits an invisible light beam to the receiving eye (with a green indicator light). If an obstruction breaks the light beam while the door is closing, the door will stop and reverse to full open position, and the opener lights will fl ash 10 times.
The units must be installed inside the garage so that the sending and receiving eyes face each other across the door, no more than 6" (15 cm) above the fl oor. Either can be installed on the left or right of the door as long as the sun never shines directly into the receiving eye lens.
The mounting brackets are designed to clip onto the track of sectional garage doors without additional hardware.
®
Be sure power is NOT connected to the garage door opener BEFORE installing the safety reversing sensor.
To prevent SERIOUS INJURY or DEATH from a closing garage door:
• Correctly connect and align the safety reversing sensor. This required safety device MUST NOT be disabled.
• Install the safety reversing sensor so beam is NO HIGHER than 6" (15 cm) above garage fl oor.
If it is necessary to mount the units on the wall, the brackets must be securely fastened to a solid surface such as the wall framing. Extension brackets (see accessories) are available if needed. If installing in masonry construction, add a piece of wood at each location to avoid drilling extra holes in masonry if repositioning is necessary.
The invisible light beam path must be unobstructed. No part of the garage door (or door tracks, springs, hinges, rollers or other hardware) may interrupt the beam while the door is closing.
Safety Reversing Sensor 6" (15 cm) max. above floor
FACING THE DOOR FROM INSIDE THE GARAGE.
Invisible Light Beam Protection Area
Safety Reversing Sensor 6" (15 cm) max. above floor
16
Page 17
INSTALLING THE BRACKETS
Be sure power to the opener is disconnected. Install
and align the brackets so the sensors will face each other across the garage door, with the beam no higher than 6" (15 cm) above the fl oor. They may be installed in one of three ways, as follows.
Garage door track installation (preferred):
• Slip the curved arms over the rounded edge of each door track, with the curved arms facing the door. Snap into place against the side of the track. It should lie fl ush, with the lip hugging the back edge of the track, as shown in Figure 1.
If your door track will not support the bracket securely, wall installation is recommended.
Wall installation (Figures 2 & 3):
• Place the bracket against the wall with curved arms facing the door. Be sure there is enough clearance for the sensor beam to be unobstructed.
• If additional depth is needed, an extension bracket (see accessories) or wood blocks can be used.
• Use bracket mounting holes as a template to locate and drill (2) 3/16" diameter pilot holes on the wall at each side of the door, no higher than 6" (15 cm) above the fl oor.
• Attach brackets to wall with lag screws (Not provided).
• If using extension brackets or wood blocks, adjust right and left assemblies to the same distance out from the mounting surface. Make sure all door hardware obstructions are cleared.
Floor installation (Figure 4):
• Use wood blocks or extension brackets (see accessories) to elevate sensor brackets so the lenses will be no higher than 6" (15 cm) above the fl oor.
• Carefully measure and place right and left assemblies at the same distance out from the wall. Be sure all door hardware obstructions are cleared.
• Fasten to the fl oor with concrete anchors as shown.
Figure 1
Figure 2
Figure 3
Door Track
Lip
Safety Reversing Sensor Bracket
(Provided with Extension Bracket)
DOOR TRACK MOUNT (RIGHT SIDE)
Indicator Light
Lens
WALL MOUNT (RIGHT SIDE)
Fasten Wood Block to Wall with Lag Screws (not provided)
Indicator Light
WALL MOUNT (RIGHT SIDE)
Extension Bracket (See Accessories)
Lens
Safety Reversing Sensor Bracket
Lag Screws (not provided)
Lens
(Provided with Extension Bracket)
Safety Reversing Sensor Bracket
Indicator Light
HARDWARE SHOWN ACTUAL SIZE
Carriage Bolt 1/4"-20x1/2"
Wing Nut 1/4"-20
Staples
17
Figure 4
FLOOR MOUNT (RIGHT SIDE)
Attach with Concrete Anchors (not provided)
Lens
Indicator Light
Safety Reversing Sensor Bracket
Page 18
MOUNTING AND WIRING THE SAFETY REVERSING SENSORS
Mounting:
• Slide a 1/4"-20x1/2" carriage bolt head into the slot on each sensor. Use wing nuts to fasten sensors to brackets, with lenses pointing toward each other across the door. Be sure the lens is not obstructed by a bracket extension (Figure 5).
• Finger tighten the wing nuts.
Option A - Installation Without Pre-Wiring:
• Run the bell wire from both sensors to the garage door opener. Attach the wire to the wall and ceiling with the staples (Figure 6).
Option B - Pre-Wired Installation:
If your garage already has wires installed for the safety reversing sensors, follow the instructions below:
• Cut the end of the safety sensor wire, making sure there is enough wire to reach the pre-installed wires from the wall (Figure 7).
• Separate the safety sensor wires and strip 7/16 inch (11 mm) of insulation from each end. Choose two of the pre-installed wires and strip 7/16 inch (11 mm) of insulation from each end. Make sure that you choose the same color pre-installed wires for each sensor (Figure 8).
• Connect the pre-installed wires to the sensor wires with wire nuts making sure the colors correspond for each sensor (Figure 9).
Figure 5
Wing Nut
Carriage Bolt 1/4"-20x1/2"
Lens
Figure 6
Figure 7
Figure 8
Safety Reversing Sensor Wires
Figure 9
Safety Reversing Sensor Wires
18
7/16"
(11mm)
7/16"
(11mm)
Pre-Installed Wires
Not Provided
Pre-installed
wires
White
White/Black
Page 19
Connect to garage door opener:
• Strip 7/16" (11 mm) of insulation from each set of wires. Separate white and white/black wires suffi ciently to connect to the opener quick-connect terminals. Twist like colored wires together. Insert wires into quick-connect holes: white to white and white/black to grey (Figure 10).
Figure 10
Bell Wire
Safety Reversing Sensor
Finished
Ceiling
Invisible Light Beam Protection Area
Connect Wire to Quick-Connect Terminals
Bell Wire
Safety Reversing Sensor
ALIGNING THE SAFETY REVERSING SENSORS
• Plug in the opener. The indicator lights in both the
sending and receiving eyes will glow steadily if wiring connections and alignment are correct.
The sending eye amber indicator light will glow regardless of alignment or obstruction. If the green indicator light in the receiving eye is off, dim, or fl ickering (and the invisible light beam path is not obstructed), alignment is required.
• Loosen the sending eye wing nut and readjust, aiming
directly at the receiving eye. Lock in place.
• Loosen the receiving eye wing nut and adjust sensor
until it receives the sender’s beam. When the green indicator light glows steadily, tighten the wing nut.
1. Strip wire 7/16" (11 mm)
2. Twist like colored wires together
3. To insert or release wire, push in tab with screwdriver tip
Quick-Connect Terminals
7/16" (11 mm)
Red White Grey
TROUBLESHOOTING THE SAFETY REVERSING SENSORS
1. If the sending eye indicator light does not glow steadily after installation, check for:
• Electric power to the opener.
• A short in the white or white/black wires. These can occur at staples, or at opener connections.
• Incorrect wiring between sensors and opener.
• A broken wire.
2. If the sending eye indicator light glows steadily but the
receiving eye indicator light doesn’t:
• Check alignment.
• Check for an open wire to the receiving eye.
3. If the receiving eye indicator light is dim, realign
either sensor.
NOTE: When the invisible beam path is obstructed or misaligned while the door is closing, the door will reverse. If the door is already open, it will not close. The opener lights will blink 10 times. See page 16.
19
Page 20
INSTALLATION STEP 11

Fasten the Door Bracket

Follow instructions which apply to your door type as illustrated below or on the following page.
A horizontal reinforcement brace should be long enough to be secured to two or three vertical supports. A vertical reinforcement brace should cover the height of the top panel.
Figure 1 shows one piece of angle iron as the horizontal brace. For the vertical brace, 2 pieces of angle iron are used to create a U-shaped support. The best solution is to check with your garage door manufacturer for an opener installation door reinforcement kit.
NOTE: Many door reinforcement kits provide for direct attachment of the clevis pin and door arm. In this case you will not need the door bracket; proceed to Step 12.
SECTIONAL DOORS
1. Center the door bracket on the previously marked vertical centerline used for the header bracket installation. Note correct UP placement, as stamped inside the bracket.
2. Position the top edge of the bracket 2"-4" (5-10 cm) below the top edge of the door, OR directly below any structural support across the top of the door.
3. Mark, drill holes and install as follows, depending on your door’s construction:
Metal or light weight doors using a vertical angle iron brace between the door panel support and the door bracket:
• Drill 3/16" fastening holes. Secure the door bracket using the two 1/4"-14x5/8" self-threading screws (Figure 2A).
• Alternately, use two 5/16" bolts, lock washers and nuts (not provided) (Figure 2B).
Metal, insulated or light weight factory reinforced doors:
• Drill 3/16" fastening holes. Secure the door bracket using the self-threading screws (Figure 3).
Wood Doors:
• Use top and bottom or side to side door bracket holes. Drill 5/16" holes through the door and secure bracket with 5/16"x2" carriage bolts, lock washers and nuts (not provided) (Figure 4).
NOTE: The 1/4"-14x5/8" self-threading screws are not intended for use on wood doors.
HARDWARE SHOWN ACTUAL SIZE
Self-Threading Screw 1/4"-14x5/8"
Fiberglass, aluminum or lightweight steel garage doors WILL REQUIRE reinforcement BEFORE installation of door bracket. Contact your door manufacturer for reinforcement kit.
Header Bracket
Door Bracket Location
HORIZONTAL AND VERTICAL
Vertical Centerline of Garage Door
REINFORCEMENT IS NEEDED FOR LIGHTWEIGHT GARAGE DOORS (FIBERGLASS, ALUMINUM, STEEL, DOORS WITH GLASS PANEL, ETC.). (NOT PROVIDED)
Figure 1
Vertical Reinforcement
Vertical Centerline of Garage Door
Vertical Reinforcement
Door Bracket
Self-Threading Screw 1/4"-14x5/8"
Figure 2A
(Not Provided)
UP
Bolt 5/16"-18x2"
Lock Washer 5/16"
Door Bracket
Vertical Centerline of Garage Door
Nut 5/16"-18
Figure 2B
Inside Edge of Door or Reinforcement Board
Figure 4
Vertical Centerline of Garage Door
UP
Self-Threading Screw 1/4"-14x5/8"
Bolt 5/16"x2" (Not Provided)
Vertical Centerline of Garage Door
Figure 3
UP
UP
20
Page 21
ONE-PIECE DOORS
Please read and comply with the warnings and reinforcement instructions on the previous page. They apply to one-piece doors also.
• Center the door bracket on the top of the door, in line with the header bracket as shown. Mark either the left and right, or the top and bottom holes.
Metal Doors: Drill 3/16" pilot holes and fasten the bracket with the 1/4"-14x5/8" self-threading screws provided.
Wood Doors: Drill 5/16" holes and use 5/16"x2" carriage bolts, lock washers and nuts (not provided) or 5/16"x1­1/2" lag screws (not provided) depending on your installation needs.
NOTE: The door bracket may be installed on the top edge of the door if required for your installation (Refer to the dotted line optional placement drawing).
Header Wall
Header Bracket
Door Bracket
Optional Placement of Door Bracket
Vertical Centerline of Garage Door
2x4 Support
For a door with no exposed framing, or for the optional installation, use lag screws 5/16"x1-1/2" (Not Provided) to fasten door bracket.
Finished Ceiling
HORIZONTAL AND VERTICAL REINFORCEMENT IS NEEDED FOR LIGHTWEIGHT GARAGE DOORS (FIBERGLASS, ALUMINUM, STEEL, DOORS WITH GLASS PANEL, ETC.). (NOT PROVIDED)
HARDWARE SHOWN ACTUAL SIZE
Self-Threading Screw 1/4"-14x5/8"
Self-Threading Screw
Door Bracket
Nut 5/16"-18
Door Bracket
1/4"-14x5/8"
Top of Door (Inside Garage)
Top Edge of Door
Optional Placement
METAL DOOR
Lock Washer 5/16"
Top of Door (Inside Garage)
Top Edge of Door
Optional Placement
Carriage Bolt 5/16"x2" (Not Provided)
WOOD DOOR
21
Page 22
INSTALLATION STEP 12

Connect Door Arm to Trolley

Follow instructions which apply to your door type as illustrated below and on the following page.
SECTIONAL DOORS ONLY
Make sure garage door is fully closed. Pull the emergency release handle to disconnect the outer trolley from the inner trolley. Slide the outer trolley back (away from the door) about 2" (5 cm) as shown in Figures 1, 2 and 3.
Figure 1:
• Fasten straight door arm section to outer trolley with the
5/16"x1" clevis pin. Secure the connection with a ring fastener.
• Fasten curved section to the door bracket in the same
way, using the 5/16"x1-1/4" clevis pin.
IMPORTANT: The groove on the straight door arm MUST face away from the curved door arm (Figure 4).
Figure 2:
• Bring arm sections together. Find two pairs of holes that
line up and join sections. Select holes as far apart as possible to increase door arm rigidity.
Figure 3, Hole alignment alternative:
• If holes in curved arm are above holes in straight arm,
disconnect straight arm. Cut about 6" (15 cm) from the solid end. Reconnect to trolley with cut end down as shown.
• Bring arm sections together.
• Find two pairs of holes that line up and join with bolts,
lock washers and nuts.
Pull the emergency release handle toward the opener at a 45° angle so that the trolley release arm is horizontal. Proceed to Adjustment Step 1, page 24. Trolley will re-engage automatically when opener is operated.
HARDWARE SHOWN ACTUAL SIZE
Figure 1
Figure 2
Nuts 5/16"-18
Nuts 5/16"-18
Inner Trolley
Outer Trolley
Ring Fastener
Door Bracket
Clevis Pin 5/16"x1-1/4"
Lock Washers 5/16"
Door Bracket
Lock Washers 5/16"
Clevis Pin 5/16"x1"
Straight Door Arm
Curved Door Arm
Emergency Release Handle
Bolts 5/16"-18x7/8"
Nut 5/16"-18
Ring Fastener
Clevis Pin 5/16"x1-1/4" (Door Bracket)
Clevis Pin 5/16"x1" (Trolley)
Lock Washer 5/16"
Hex Bolt 5/16"-18x7/8"
22
Figure 3
Cut this end
CORRECT INCORRECT
Straight Door Arm
(Groove
facing out)
Curved Door Arm
Figure 4
Bolts 5/16"-18x7/8"
Straight Door Arm
Curved Door Arm
Page 23
ALL ONE-PIECE DOORS
1. Assemble the door arm, Figure 5:
IMPORTANT: The groove on the straight door arm
MUST face away from the curved door arm (Figure 5).
• Fasten the straight and curved door arm sections
together to the longest possible length (with a 2 or 3 hole overlap).
• With the door closed, connect the straight door arm
section to the door bracket with the 5/16"x1-1/4" clevis pin.
• Secure with a ring fastener.
2. Adjustment procedures, Figure 6:
• On one-piece doors, before connecting the door arm
to the trolley, the travel limits must be adjusted. Limit adjust ment screws are located on the left side panel as shown on page 24. Follow adjustment procedures below.
• Open door adjustment: decrease UP travel limit
- Turn the UP limit adjustment screw
counter-clockwise 4 turns.
- Press the door control push button. The trolley will
travel to the fully open position.
- Manually raise the door to the open position
(parallel to the fl oor), and lift the door arm to the trolley. The arm should touch the trolley just in back of the door arm connector hole. Refer to the fully open trolley/door arm positions in the illustration. If the arm does not extend far enough, adjust the limit further. One full turn equals 3" (7.5 cm) of trolley travel.
• Closed door adjustment: decrease DOWN
travel limit
- Turn the DOWN limit adjustment screw clockwise 4
complete turns.
Figure 6
Door Arm
Closed Door
Inner Trolley
Door Arm Connector Hole
Outer Trolley
Emergency Release Handle
Figure 5
CORRECT INCORRECT
Straight Door Arm
(Groove
facing out)
Door Bracket
Clevis Pin 5/16"x1-1/4"
Curved Door Arm
Ring Fastener
Straight Arm
Bolts 5/16"-18x7/8
Straight Door Arm
Lock Washers 5/16"
Curved Door Arm
Nuts 5/16"-18
Curved Door Arm
- Press the door control push button. The trolley will travel to the fully closed position.
- Manually close the door and lift the door arm to the trolley. The arm should touch the trolley just ahead of the door arm connector hole. Refer to the fully closed trolley/door arm positions in the illustration. If the arm is behind the connector hole, adjust the limit further. One full turn equals 3" (7.5 cm) of trolley travel.
3. Connect the door arm to the trolley:
• Close the door and join the curved arm to the
connector hole in the trolley with the remaining clevis pin. It may be necessary to lift the door slightly to make the connection.
• Secure with a ring fastener.
• Run the opener through a complete travel cycle. If
the door has a slight “backward” slant in full open position as shown in the illustration, decrease the UP limit until the door is parallel to the fl oor.
NOTE: When setting the up limit on the following page, the door should not have a “backward” slant when fully open as illustrated below. A slight backward slant will cause unnecessary bucking and/or jerking operation as the door is being opened or closed from the fully open position.
Inner Trolley
Open Door
Correct Angle
Outer Trolley
Door Arm
Door with Backward Slant (Incorrect)
23
Page 24
ADJUSTMENT STEP 1

Adjust the UP and DOWN Travel Limits

Limit adjustment settings regulate the points at which the door will stop when moving up or down.
To operate the opener, press the door control push bar. Run the opener through a complete travel cycle.
• Does the door open and close completely?
• Does the door stay closed and not reverse unintentionally when fully closed?
If your door passes both of these tests, no limit adjustments are necessary unless the reversing test fails (Adjustment Step 3, page 26).
Adjustment procedures are outlined below. Read the procedures carefully before proceeding to Adjustment Step 2. Use a screwdriver to make limit adjustments. Run
the opener through a complete travel cycle after each adjustment.
NOTE: Repeated operation of the opener during adjustment procedures may cause the motor to overheat and shut off. Simply wait 15 minutes and try again. If anything interferes with the door’s upward travel, it will stop. If anything interferes with the door’s downward travel (including binding or unbalanced doors), it will reverse.
Without a properly installed safety reversal system, persons (particularly small children) could be SERIOUSLY INJURED or KILLED by a closing garage door.
• Incorrect adjustment of garage door travel limits will interfere with proper operation of safety reversal system.
• If one control (force or travel limits) is adjusted, the other control may also need adjustment.
• After ANY adjustments are made, the safety reversal system MUST be tested. Door MUST reverse on contact with 1-1/2" high (3.8 cm) object (or 2x4 laid fl at) on fl oor.
To prevent damage to vehicles, be sure fully open door provides adequate clearance.
Cover Protection Bolt
HOW AND WHEN TO ADJUST THE LIMITS
• If the door does not open completely but opens at least 5 feet (1.5 m):
Increase up travel. Turn the UP limit adjustment screw
clockwise. One turn equals 3" (7.5 cm) of travel.
NOTE: To prevent the trolley from hitting the cover
protection bolt, keep a minimum distance of 2-4" (5 cm-10 cm) between the trolley and the bolt.
• If door does not open at least 5 feet (1.5 m):
Adjust the UP (open) force as explained in Adjustment
Step 2.
• If the door does not close completely:
Increase down travel. Turn the down limit adjustment
screw counterclockwise. One turn equals 3" (7.5 cm) of travel.
If door still won't close completely and the trolley
bumps into the pulley bracket (page 4), try lengthening the door arm (page 22) and decreasing the down limit.
• If the opener reverses in fully closed position:
Decrease down travel. Turn the down limit adjustment
screw clockwise. One turn equals 3" (7.5 cm) of travel.
2-4"
(5 cm-10 cm)
• If the door reverses when closing and there is no visible interference to travel cycle:
If the opener lights are fl ashing, the Safety Reversing
Sensors are either not installed, misaligned, or obstructed. See Troubleshooting, page 19.
Test the door for binding: Pull the emergency release
handle. Manually open and close the door. If the door is binding or unbalanced, call for a trained door systems technician. If the door is balanced and not binding, adjust the DOWN (close) force. See Adjustment Step 2.
Left Side Panel
Limit Adjustment Screws
ADJUSTMENT LABEL
24
Page 25
ADJUSTMENT STEP 2

Adjust the Force

Force adjustment controls are located on the back panel of the motor unit. Force adjustment settings regulate the amount of power required to open and close the door.
If the forces are set too light, door travel may be interrupted by nuisance reversals in the down direction and stops in the up direction. Weather conditions can affect the door movement, so occasional adjustment may be needed.
The maximum force adjustment range is about 3/4 of a complete turn. Do not force controls beyond that point.
Turn force adjustment controls with a screwdriver.
NOTE: If anything interferes with the door’s upward travel, it will stop. If anything interferes with the door’s downward travel (including binding or unbalanced doors), it will reverse.
HOW AND WHEN TO ADJUST THE FORCES
1. Test the DOWN (close) force
• Grasp the door bottom when the door is about halfway through DOWN (close) travel. The door should reverse.
Reversal halfway through down travel does not guarantee reversal on a 1-1/2" (3.8 cm) obstruction. See Adjustment Step 3, page 26. If the door is hard to
hold or doesn’t reverse, DECREASE the DOWN (close) force by turning the control counterclockwise. Make small adjustments until the door reverses normally. After each adjustment, run the opener through a complete cycle.
If the door reverses during the down (close) cycle and the opener lights aren’t fl ashing, INCREASE DOWN (close) force by turning the control clockwise. Make small adjustments until the door completes a close cycle. After each adjustment, run the opener through a complete travel cycle. Do not increase the force beyond
the minimum amount required to close the door.
2. Test the UP (open) force
• Grasp the door bottom when the door is about halfway through UP (open) travel. The door should stop. If the door is hard to hold or doesn’t stop, DECREASE UP (open) force by turning the control counterclockwise. Make small adjustments until the door stops easily and opens fully. After each adjustment, run the opener through a complete travel cycle.
If the door doesn’t open at least 5 feet (1.5 m), INCREASE UP (open) force by turning the control clockwise. Make small adjustments until door opens completely. Readjust the UP limit if necessary. After each adjustment, run the opener through a complete travel cycle.
Without a properly installed safety reversal system, persons (particularly small children) could be SERIOUSLY INJURED or KILLED by a closing garage door.
• Too much force on garage door will interfere with proper operation of safety reversal system.
• NEVER increase force beyond minimum amount required to close garage door.
• NEVER use force adjustments to compensate for a binding or sticking garage door.
• If one control (force or travel limits) is adjusted, the other control may also need adjustment.
• After ANY adjustments are made, the safety reversal system MUST be tested. Door MUST reverse on contact with 1-1/2" high (3.8 cm) object (or 2x4 laid fl at) on fl oor.
Force Adjustment Controls
Right Panel
Antenna
FORCE ADJUSTMENT LABEL
Open Force
Close Force
25
Page 26
ADJUSTMENT STEP 3

Test the Safety Reversal System

TEST
• With the door fully open, place a 1-1/2" (3.8 cm) board (or a 2x4 laid fl at) on the fl oor, centered under the garage door.
• Operate the door in the down direction. The door must reverse on striking the obstruction.
ADJUST
• If the door stops on the obstruction, it is not traveling far enough in the down direction. Increase the DOWN limit by turning the DOWN limit adjustment screw counterclockwise 1/4 turn.
NOTE: On a sectional door, make sure limit adjustments
do not force the door arm beyond a straight up and down position. See the illustration on page 22.
• Repeat the test.
• When the door reverses on the 1-1/2" (3.8 cm) board, remove the obstruction and run the opener through 3 or 4 complete travel cycles to test adjustment.
• If the unit continues to fail the Safety Reverse Test, call for a trained door systems technician.
IMPORTANT SAFETY CHECK:
Test the Safety Reverse System after:
• Each adjustment of door arm length, limits, or force controls.
• Any repair to or adjustment of the garage door (including springs and hardware).
• Any repair to or buckling of the garage fl oor.
• Any repair to or adjustment of the opener.
Without a properly installed safety reversal system, persons (particularly small children) could be SERIOUSLY INJURED or KILLED by a closing garage door.
• Safety reversal system MUST be tested every month.
• If one control (force or travel limits) is adjusted, the other control may also need adjustment.
• After ANY adjustments are made, the safety reversal system MUST be tested. Door MUST reverse on contact with 1-1/2" high (3.8 cm) object (or 2x4 laid fl at) on the fl oor.
1-1/2" (3.8 cm) board (or a 2x4 laid fl at)
ADJUSTMENT STEP 4
Test The Protector System
• Press the remote control push button to open the door.
• Place the opener carton in the path of the door.
• Press the remote control push button to close the door. The door will not move more than 1" (2.5 cm), and the opener lights will fl ash.
The garage door opener will not close from a remote if the indicator light in either sensor is off (alerting you to the fact that the sensor is misaligned or obstructed).
If the opener closes the door when the safety reversing sensor is obstructed (and the sensors are no more than 6" (15 cm) above the fl oor), call for a trained door systems technician.
®
Without a properly installed safety reversing sensor, persons (particularly small children) could be SERIOUSLY INJURED or KILLED by a closing garage door.
Safety Reversing Sensor Safety Reversing Sensor
26
Page 27

OPERATION

WARNING
WARNING
WARNING WARNING
IMPORTANT INSTALLATION INSTRUCTIONS
To reduce the risk of SEVERE INJURY or DEATH:
1. READ AND FOLLOW ALL WARNINGS AND INSTRUCTIONS.
2. ALWAYS keep remote controls out of reach of children. NEVER permit children to operate or play with garage door control push buttons or remote controls.
3. ONLY activate garage door when it can be seen clearly, it is properly adjusted, and there are no obstructions to door travel.
4. ALWAYS keep garage door in sight until completely closed. NO ONE SHOULD CROSS THE PATH OF THE MOVING DOOR.
5. NO ONE SHOULD GO UNDER A STOPPED, PARTIALLY OPEN DOOR.
6. If possible, use emergency release handle to disengage trolley ONLY when garage door is CLOSED. Weak or broken springs or unbalanced door could result in an open door falling rapidly and/or unexpectedly, causing SEVERE INJURY or DEATH.
7. NEVER use emergency release handle unless garage doorway is clear of persons and obstructions.
8. NEVER use handle to pull garage door open or closed. If rope knot becomes untied, you could fall.

Using Your Garage Door Opener

Your Security® opener and hand-held remote control have been factory-set to a matching code which changes with each use, randomly accessing over 100 billion new codes. Your opener will operate with up to eight Security Entry System. If you purchase a new remote, or if you wish to deactivate any remote, follow the instructions in the Programming section.
Activate your opener with any of the following:
The hand-held Remote Control: Hold the large push
The wall-mounted Door Control: Hold the push button
The Keyless Entry (See Accessories): If provided with
When the opener is activated (with the safety reversing sensor correctly installed and aligned)
1. If open, the door will close. If closed, it will open.
2. If closing, the door will reverse.
3. If opening, the door will stop.
4. If the door has been stopped in a partially open
5. If obstructed while closing, the door will reverse.
®
remote controls and one Security® Keyless
button down until the door starts to move.
or bar down until the door starts to move.
your garage door opener, it must be programmed before use. See Programming.
position, it will close.
If the obstruction interrupts the sensor beam, the opener lights will blink for fi ve seconds.
9. If one control (force or travel limits) is adjusted, the other control may also need adjustment.
10. After ANY adjustments are made, the safety reversal system MUST be tested.
11. Safety reversal system MUST be tested every month. Garage door MUST reverse on contact with 1-1/2" (3.8 cm) high object (or a 2x4 laid fl at) on the fl oor. Failure to adjust the garage door opener properly may cause SEVERE INJURY or DEATH.
12. ALWAYS KEEP GARAGE DOOR PROPERLY BALANCED (see page 3). An improperly balanced door may NOT reverse when required and could result in SEVERE INJURY or DEATH.
13. ALL repairs to cables, spring assemblies and other hardware, ALL of which are under EXTREME tension, MUST be made by a trained door systems technician.
14. ALWAYS disconnect electric power to garage door opener BEFORE making ANY repairs or removing covers.
15.
SAVE THESE INSTRUCTIONS.
6. If obstructed while opening, the door will stop.
7. If fully open, the door will not close when the beam is broken. The sensor has no effect in the opening cycle.
If the sensor is not installed, or is misaligned, the door won’t close from a hand-held remote. However, you can close the door with the Door Control, the Outside Keylock, or Keyless Entry, if you activate them until down travel is complete. If you release them too soon, the door will reverse.
The opener lights will turn on under the following conditions: when the opener is initially plugged in; when power is restored after interruption; when the opener is activated.
They will turn off automatically after 4-1/2 minutes or provide constant light when the Light feature on the Smart Control Panel power is 100 watts maximum.
Security
someone walks through the open garage door. With an Smart Control Panel follows: With the opener lights off, press and hold the light button for 10 seconds, until the light goes on, then off again. To restore this feature, start with the opener lights on, then press and hold the light button for 10 seconds until the light goes off, then on again.
27
®
is activated. Bulb size is A19. Bulb
®
light feature: Lights will also turn on when
®
, this feature may be turned off as
Page 28

Using the Wall-Mounted Door Control

THE SMART CONTROL PANEL
Press the push bar to open or close the door. Press again to reverse the door during the closing cycle or to stop the door while it's opening.
This door control contains a motion sensing detector that will automatically turn on the light when it detects a person entering the garage.
and then activate the opener, the light will remain on for 4-1/2 minutes. Press again to turn it off sooner. The 4-1/2 minute interval can be changed to 1-1/2, 2-1/2, or 3-1/2 minutes as follows: Press and hold the Lock button until the light blinks (about 10 seconds). A single blink indicates that the timer is reset to 1-1/2 minutes. Repeat the procedure and the light will blink twice, resetting the timer to 2-1/2 minutes. Repeat again for a 3-1/2 minute interval, etc., up to a maximum of four blinks and 4-1/2 minutes.
When using the opener lights as working lights, we recommend that you fi rst disable the motion sensor. See Automatic Light Feature, below.
Motion Sensing On/Off
Prog <Learn>
Hour
Minute
Language
Degrees (F/C)
Light Feature
Press the Light button to turn the opener light on or off. It will not control the opener lights when the door is in motion. If you turn it on
®
Push Bar
Light Button
Lock Button
(PROG) Learn Feature
The door control is equipped with a PROG <LEARN> button to assist in learning remote controls to the unit. Press the PROG <LEARN> button once to initiate LEARN mode and the display will show ‘Learn Remote Control ­Press Learn Button Again to Confi rm’. Press the PROG <LEARN> button a second time and the display will show ‘Learn Mode - Press Remote Control Button to Learn Remote.’ Press the button of the remote control to be learned and the worklight will blink to confi rm the remote control has been learned.
Hour & Minute Feature
Press or hold either of these side buttons to increment the hour or minute displayed on the LCD display.
(LANG) Language Feature
Press this side button to toggle between the three languages - English, French and Spanish.
Degrees F/C Feature
Press this side button to toggle the temperature units between Fahrenheit and Celsius.
Display Contrast Adjustment
Press and hold the light button then push the hour button to increase the contrast or the minute button to decrease the contrast.
Motion Sensing (Automatic Light Feature): The opener light will turn on automatically when a person enters the garage. When a
person walks in front of the door control, the light will come on for fi ve minutes, then shut off. This feature works by detecting body heat.
To disable this feature, push the motion sensing button on the side of the door control.
We recommend that you disable the motion sensor when using the opener lights as working lights. Otherwise, they will turn off automatically if you are working beyond the sensors range.
Lock Feature
Designed to prevent operation of the door
from hand-held remote controls. However, the door will open and close from the Door Control, the Outdoor Key Switch and the Keyless Entry Accessories.
To activate, press and hold the Lock button for 2 seconds.
To turn off, press and hold the Lock button again for 2 seconds. The Lock feature will also turn off whenever the “learn” button on the motor unit panel is activated.
28
Page 29

Using the Remote Control

NOTE: To activate the remote control functions, pull out
the plastic pull tab protruding from the remote control housing.
This remote control is equipped with a proximity lighting feature. When moving a hand within close proximity to the remote control, the LED lights turn on for 3 seconds. Upon successful activation of a remote control button, the LED lights will blink rapidly.
PROXIMITY DISABLE FEATURE
The remote control will turn off the proximity lighting feature if the proximity lighting is turned on 10 consecutive times without activation of a button. To re-enable the proximity lighting, simply press a button. This function conserves battery life.
TO CONTROL THE OPENER LIGHTS
With 315MHz Security® remote controls, a remote push button can be programmed to operate the opener lights without opening the door.
1. With the door closed, press and hold the remote button
that you want to control the light.
2. Press and hold the Light button on the
Smart Control Panel
3. Press and hold the Lock button on the
Smart Control Panel
4. After the opener lights fl ash, release all buttons.
Test by pressing the remote push button. The opener lights should turn on or off but the door should not move.
®
.
®
.

Troubleshooting

PROBLEM SOLUTION
Check if proximity lighting is disabled by pressing a button.
The Proximity Sensor
Reduced proximity sensing (does not activate by touching top of remote control)
Dim LED lights
No rapid LED blinking after pressing a button
may be oversensitized. Sit remote control undisturbed for 60 seconds on a non-metallic surface. This allows the sensor to recalibrate itself.
Replace 3V2450 battery with same type 3V2450 coin cell.
Replace two 3V2016 batteries with same type 3V2016 coin cells.
Replace two 3V2016 batteries with same type 3V2016 coin cells.

The Remote Control Battery

To prevent possible SERIOUS INJURY or DEATH:
• NEVER allow small children near batteries.
• If battery is swallowed, immediately notify doctor. To reduce risk of fi re, explosion or chemical burn:
• Replace ONLY with 3V2016 or 3V2450 coin batteries.
• DO NOT recharge, disassemble, heat above 100° C (212° F) or incinerate.
The 3V2016 lithium batteries for the opener and LED lights (marked “LED and Opener Battery”) should last 5 years. The 3V2450 lithium battery for the proximity lighting (marked “Proximity Battery”) should last 1-2 years.
To replace the batteries, remove the two screws and open the remote control housing. Push the battery out of the holder for removal. Insert replacement batteries positive side up. Dispose
LED and Opener Batteries
of old batteries properly.
Replace the batteries with only 3V2016 or 3V2450 coin cell batteries.
CAUTION: Do not bend spring contact. If bent the proximity sensor will not work.
NOTICE: To comply with FCC and or Industry Canada (IC) rules, adjustment or modifi cations of this receiver and/or transmitter are prohibited, except for changing the code setting or replacing the battery. THERE ARE NO OTHER USER SERVICEABLE PARTS.
Tested to Comply with FCC Standards FOR HOME OR OFFICE USE. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Proximity Battery
Spring Contact
29
Page 30

To Open the Door Manually

To prevent possible SERIOUS INJURY or DEATH from a falling garage door:
• If possible, use emergency release handle to disengage trolley ONLY when garage door is CLOSED. Weak or broken springs or unbalanced door could result in an open door falling rapidly and/ or unexpectedly.
• NEVER use emergency release handle unless garage doorway is clear of persons and obstructions.
• NEVER use handle to pull door open or closed. If rope knot becomes untied, you could fall.
The door should be fully closed if possible. Pull down on the emergency release handle and lift the door manually. To reconnect the door to the opener, press the door control push bar.
The lockout feature prevents the trolley
Emergency Release Handle (Pull Down)
MANUAL DISCONNECT
POSITION
from reconnecting automatically. Pull the emergency release handle down and back (toward the opener). The door can then be raised and lowered manually as often as necessary. To disengage the lockout feature, pull the handle straight down. The trolley
Emergency Release Handle (Down and Back)
LOCKOUT POSITION
will reconnect on the next UP or DOWN operation, either manually or by using the door control or remote.
Trolley Release Arm
Trolley Release Arm
MAINTENANCE SCHEDULE
Every Month
• Manually operate door. If it is unbalanced or binding, call a trained door systems technician.
• Check to be sure door opens and closes fully. Adjust limits and/or force if necessary. (See pages 24 and 25.)
• Repeat the safety reverse test. Make any necessary adjustments. (See Adjustment Step 3.)
Every Year
• Oil door rollers, bearings and hinges. The opener does not require additional lubrication. Do not grease the door tracks.
Every Three to Four Years
• Use a rag to wipe away the existing grease from the garage door opener rail. Reapply a small layer of white lithium grease to the rail.
CARE OF YOUR OPENER
LIMIT AND FORCE ADJUSTMENTS:
Weather conditions may cause some minor changes in door operation requiring some re-adjustments, particularly during the fi rst year of operation.
Pages 24 and 25 refer to the limit and force adjustments. Only a screwdriver is required. Follow the instructions carefully.
Repeat the safety reverse test (Adjustment Step 3, page 26) after any adjustment of limits or force.
FORCE CONTROLS
LIMIT CONTROLS
30
Page 31

HAVING A PROBLEM?

1. My door will not close and the light bulbs blink on my motor unit: The safety reversing sensor must be
connected and aligned correctly before the garage door opener will move in the down direction.
• Verify the safety sensors are properly installed,
aligned and free of any obstructions. Refer to
Installation Step 10: Install The Protector System
• Check diagnostic LED for fl ashes on the motor unit
then refer to the Diagnostic Chart on the following page.
2. My remotes will not activate the door:
• Verify your door control is not blinking. If it is
blinking, deactivate the Lock Mode following the instructions for Using the Wall Mounted Door Control.
• Reprogram remotes following the programming
instructions. Refer to Programming.
• If remote will still not activate your door, check
diagnostic LED for fl ashes on motor unit then refer to Diagnostic Chart on the following page.
3. My door reverses for no apparent reason: Repeat safety reverse test after adjustments to force or travel limits. The need for occasional adjustment for the force and limit settings is normal. Weather conditions in particular can affect door travel.
• Manually check door for balance or any binding
problems.
• Refer to Adjustment Step 2, Adjust the force.
4. My door reverses for no apparent reason after fully closing and touching the fl oor: Repeat safety reverse
test after adjustments to force or travel limits. The need for occasional adjustment for the force and limit settings is normal. Weather conditions in particular can affect door travel.
• Refer to Adjustment Step 1, Adjust the UP and
DOWN Travel Limits. Decrease down travel by turning down limit adjustment screw clockwise.
Bell Wire
®
.
Safety Reversing Sensor
Sending Eye Safety Reversing Sensor (Amber Indicator Light)
“Learn” Button LED or Diagnostic LED
Receiving Eye Safety Reversing Sensor (Green Indicator Light)
6. My motor unit hums briefl y:
• First verify that the trolley is against the stop bolt.
• Release the door from the opener by pulling the Emergency Release Rope.
• Manually bring the door to a closed position.
• Loosen the belt by adjusting the outer nut 4 to 5 turns. This relieves the tension.
• Run the motor unit from the remote control or door control. The trolley should travel towards the door and stop. If the trolley re-engages with the door, pull the Emergency Release Rope to disengage.
• Decrease the up travel by turning the UP Travel adjustment screw 2 full turns away from the arrow.
Trolley
5. My lights will not turn off when door is open:
• The garage door opener is equipped with a security light feature. This feature activates the light on when the safety sensor beam has been obstructed. Refer to Operation section; Using the Wall Mounted Door Control, Light Feature.
1-1/4"
(3.18 cm)
• Re-Tighten the outer nut until the trolley spring is approximately 1-1/4" (3.18 cm) in length.
• If the trolley does not move away from the bolt, repeat the steps above.
31
Page 32
Bell Wire
Diagnostics Located On Motor Unit
“Learn” Button LED or Diagnostic LED
Safety Reversing Sensor

Diagnostic Chart

1 FLASH
Safety reversing sensors wire open (broken or disconnected).
OR
2 FLASHES
Safety reversing sensors wire shorted or black/white wire reversed.
3 FLASHES
Door control or wire shorted.
4 FLASHES
Safety reversing sensors slightly misaligned (dim or fl ashing LED).
Installed
Safety Reversing
Sensor
Your garage door opener is programmed with self­diagnostic capabilities. The “Learn” button/diagnostic LED will fl ash a number of times then pause signifying it has found a potential issue. Consult Diagnostic Chart below.
Symptom: One or both of the Indicator lights on the safety sensors do not glow steady.
• Inspect sensor wires for a short (staple in wire), correct wiring polarity (black/white wires reversed), broken or disconnected wires, replace/attach as needed.
• Disconnect all wires from back of motor unit.
• Remove sensors from brackets and shorten sensor wires to 1-2 ft. (30-60 cm) from back each of sensor.
• Reattach sending eye to motor unit using shortened wires. If sending eye indicator light glows steadily, attach the receiving eye.
• Align sensors, if the indicator lights glow replace the wires for the sensors. If the sensor indicator lights do not light, replace the safety sensors.
Symptom: LED is not lit on door control.
• Inspect door control/wires for a short (staple in wire), replace as needed.
• Disconnect wires at door control, touch wires together. If motor unit activates, replace door control.
• If motor unit does not activate, disconnect door control wires from motor unit. Momentarily short across red and white terminals with jumper wire. If motor unit activates, replace door control wires.
Symptom: Sending indicator light glows steadily, receiving indicator light is dim or fl ashing.
• Realign receiving eye sensor, clean lens and secure brackets.
• Verify door track is fi rmly secured to wall and does not move.
5 FLASHES
Motor overheated or possible RPM sensor failure. Unplug to reset.
6 FLASHES
Motor Circuit Failure. Replace Receiver Logic Board.
Symptom: Motor has overheated; the motor unit does not operate or trolley is stuck on stop bolt = Motor unit hums briefl y; RPM Sensor = Short travel 6-8" (15-20 cm).
• Unplug unit to reset. Try to operate motor unit, check diagnostic code.
• If it is still fl ashing 5 times and motor unit moves 6-8" (15-20 cm), replace RPM sensor.
• If motor unit doesn’t operate, motor unit is overheated. Wait 30 minutes and retry. If motor unit still will not operate replace logic board.
Symptom: Motor unit doesn’t operate.
• Replace logic board because motor rarely fails.
32
Page 33

Smart Control Panel® Messages

The following messages are contained within the Smart Control Panel® and may appear during the operations of the unit:
Message
SAFETY SENSORS CHECK ALIGNMENT, BLOCKAGE OR MISWIRING. SEE OWNER’S MANUAL.
Message
SAFETY SENSORS MALFUNCTION. CHECK MISWIRING. SEE OWNER’S MANUAL.
Message
LEARN REMOTE CONTROL. PRESS LEARN BUTTON TO CONFIRM.
Meaning: This message will appear if the Safety Reversing Sensors are out of alignment, if they are blocked or if the wiring is disconnected. To clear message from Smart Control Panel
• Check to see that area is clear between the Safety Reversing Sensors.
• Check to see that the Safety Reversing Sensors are not misaligned.
• Realign receiving eye sensor, clean lens and secure brackets.
• Verify door track is fi rmly secured to wall and does not move.
• Check to see that the Safety Reversing Sensors’ wires are connected to the motor unit.
• If message has not cleared after the above checks, refer to message #2.
Meaning: This message will appear if the Safety Reversing Sensors are miswired.To clear the message, do the following:
• Inspect the safety sensor wires for a short (staple in wire), correct wiring polarity (black/white wires reversed), replace/attach as needed.
• Disconnect all wires from back of motor unit.
• Remove safety sensors from brackets and shorten sensor wires to 1-2 ft. (30-60 cm) from back of each sensor.
• Reattach sending eye to motor unit using shortened wires. If sending eye indicator light glows steadily, attach the receiving eye.
• Align sensors, if the indicator lights glow replace the wires for the sensors. If the sensor indicator lights do not light, replace the safety sensors.
Meaning: This message will appear when the Prog <LEARN> button has been pressed on the Smart Control Panel again will allow the user to program an additional remote control to the opener.
®
do the following:
®
. Pressing the Prog <LEARN> button
Message
LEARN MODE. PRESS REMOTE CONTROL BUTTON TO PROGRAM REMOTE.
Message
LOCK MODE. REMOTE CONTROL LOCKED OUT. PRESS LOCK BUTTON TO ENABLE REMOTE.
Message
ENGLISH, FRANÇAIS AND ESPAÑOL.
Message
MOTION SENSING ON, MOTION SENSING OFF.
Meaning: This message will appear when the Prog <learn> button has been pressed a second time on the Smart Control Panel The opener is ready to program another remote control by simply pressing the remote control button. Once the opener has ‘LEARNED’ the remote control, the worklight will blink one time.
Meaning: This message will appear when the ‘Lock’ button has been pressed and held for more than one second. This feature will disable the opener from receiving remote control signals. To exit ‘LOCK’ mode, press and hold the button for more than one second.
Meaning: This message will appear when the ‘Language’ button has been pressed. Pressing the button will toggle to the next language.
Meaning: This message will appear when the ‘MOTION SENSING’ button is pressed. The Motion Detector will toggle on or off with each press of the button.
33
®
or anytime on the opener.
Page 34

PROGRAMMING

NOTICE: If this Security® garage door opener is operated with a non-rolling code transmitter, the technical measure in the receiver of the garage door opener, which provides security against code-theft devices, will be circumvented. The owner of the copyright in the garage door opener does not authorize the purchaser or supplier of the non-rolling code transmitter to circumvent that technical measure.
Your garage door opener has already been programmed at the factory to operate with your hand-held remote control. The door will open and close when you press the large push button.
Below are instructions for programming your opener to operate with additional 315MHz Security

To Add or Reprogram a Hand-held Remote Control

USING THE “LEARN” BUTTON USING THE SMART CONTROL PANEL
®
remote controls.
®
1. Press and release the “learn” button on the motor unit. The learn indicator light will glow steadily for 30 seconds.
2. Within 30 seconds, press and hold the button on the hand-held remote* that you wish to operate your garage door.
3. Release the button when the motor unit lights blink. It has learned the code. If light bulbs are not installed, two clicks will be heard.
To Erase All Codes From Motor
Unit Memory
To deactivate any unwanted remote, fi rst erase all codes:
Press and hold the “learn” button on motor unit until the learn indicator light goes out (approximately 6 seconds). All previous codes are now erased. Reprogram each remote or keyless entry you wish to use.
1. Press the PROG <Learn> button on the Smart Control Panel
®
.
2. Press the PROG <Learn> button again to confi rm Learn Mode.
3. Press the button on the hand­held remote that you wish to operate your garage door.
4. When the motor unit lights blink, it has learned the code. If light bulbs are not installed, two clicks will be heard.
*3-Button Remotes (315MHz)
If provided with your garage door opener, the large button is factory programmed to operate it. Additional buttons on any Security remote or mini-remote can be programmed to operate other Security door openers.
34
®
3-button
®
garage
Page 35
NOTE: Your new Keyless Entry must be programmed to operate your garage door opener.

To Add, Reprogram or Change a Keyless Entry PIN

USING THE “LEARN” BUTTON USING THE SMART CONTROL PANEL
®
1. Press and release the “learn” button on motor unit. The learn indicator light will glow steadily for 30 seconds.
NOTE: This method requires two people if the Keyless Entry is already mounted outside the garage.
1. Press the PROG <Learn> button on the Smart Control Panel
®
.
2. Within 30 seconds, enter a four digit personal identifi cation number (PIN) of your choice on the keypad. Then press and hold
2. Press the PROG <Learn> button again to confi rm Learn Mode.
the ENTER button.
3. Release the button when the motor unit lights blink. It has learned the code. If light bulbs are not installed, two clicks will be heard.
To change an existing, known PIN
If the existing PIN is known, it may be changed by one person without using a ladder.
1. Press the four buttons for the present PIN, then press
3. Enter a four digit personal identifi cation number (PIN) of your choice on the keypad. Then press enter.
4. When the motor unit lights blink, it has learned the code. If light bulbs are not installed, two clicks will be heard.
and hold the # button.
The opener light will blink twice. Release the # button.
2. Press the new 4-digit PIN you have chosen, then press Enter.
The motor unit lights will blink once when the PIN has been learned.
Test by pressing the new PIN, then press Enter. The door should move.
To set a temporary PIN
You may authorize access by visitors or service people with a temporary 4-digit PIN. After a programmed number of hours or number of accesses, this temporary PIN expires and will no longer open the door. It can be used to close the door even after it has expired. To set a temporary PIN:
1. Press the four buttons for your personal entry PIN (not the last temporary PIN), then press and hold the button.
The opener light will blink three times. Release the
button.
2. Press the temporary 4-digit PIN you have chosen, then press Enter.
The opener light will blink four times.
3. To set the number of hours this temporary PIN will work, press the number of hours (up to 255), then press ✽.
OR
3. To set the number of times this temporary PIN will work, press the number of times (up to 255), then press #.
The opener light will blink once when the temporary PIN has been learned.
Test by pressing the four buttons for the temporary PIN, then press Enter. The door should move. If the temporary PIN was set to a certain number of openings, remember that the test has used up one opening. To clear the temporary password, repeat steps 1-3, setting the number of hours or times to 0 in step 3.
One Button Close: Opener can be closed by pressing only the ENTER button if the one button close feature has been activated. This feature has been activated at the factory. To activate or deactivate this feature press and hold buttons 1 and 9 for 10 seconds. The keypad will blink twice when the one button close is active. The keypad will blink four times when one button close is deactivated.
35
Page 36

REPAIR PARTS

Rail Assembly Parts

1
2
7

Installation Parts

1
3
6
7
9
12
3
6
4
5
KEY PART NO. NO. DESCRIPTION
1 4A1008 Master link kit
2 41B5424 Belt pulley bracket
3 41B3869-3A Complete trolley assembly
4 2777BD One-piece T-rail 7' (2 m)
2778BD Complete Rail 8' (2.4 m)
2770BD Complete Rail 10' (3 m)
5 41A5434-11 Full belt assembly
5
6 41B4103 Tensioner assembly
7 83A11-2 Rail grease
2
4
KEY PART NO. NO. DESCRIPTION
1 398LM Smart Control Panel
2 373P 3-Button remote control
8
3 10A19 3V2016 Lithium battery: LED and opener
4 10A33 3V2016 Lithium battery: proximity switch
5 29C151 Remote control visor clip
6 41A2828 Emergency release rope and handle
assembly
11
7 41B4494-1 2-Conductor bell wire, white & white/red
8 41A5047-1 Door bracket w/clevis pin & fastener
9 41A4353-1 Header bracket w/clevis pin & fastener
10 41A5034 Safety sensor kit (receiving and sending
eyes) with 3' (.9 m) 2-conductor bell wire
10
11 178B34 Straight door arm section
12 178B35 Curved door arm section
13 41A5266-1 Safety sensor brackets (2)
®
NOT SHOWN
101D173 Push bar for door control
13
41A2770-12 Installation hardware bag (includes
hardware listed on page 5).
114A4257 Owner’s manual
114A4257SP Owner’s manual - Spanish
36
Page 37

Motor Unit Assembly Parts

7
6
19
1
4
18
17
15
9
8
16
10
2
3
5
6
7
14
11
KEY PART NO. NO. DESCRIPTION
1 41A4371 Belt Cap
2 41A4885-5 Gear and sprocket assembly
Complete with: Spring washer, thrust washer, retaining ring, bearing plate, roll pins (2), drive gear and worm gear, helical gear w/ retainer and grease
3 41A2817 Drive/worm gear kit w/grease,
roll pins (2)
4 41B4245-1 Line cord
5 41A5484 End panels w/all labels
6 4A1344 Light socket
7 108D79 Lens
8 30B652 Capacitor
9 41A3150 Terminal block w/screws
10 41D5563-1 Universal replacement motor
& bracket assembly Complete with: Motor, worm, bracket, gear case, bearing assembly, RPM sensor
12
13
Brown Wire
Drive Gear
(Down) Contact
Center Limit Contact
(Up) Contact
KEY PART NO. NO. DESCRIPTION
11 41A5633-12 Cover
12 41A2818 Limit switch drive & retainer
13 41D3452 Limit switch assembly
14 41A5532 Gear case
15 41A2822-1 Interrupter cup assembly
16 41C4398A RPM sensor assembly
17 41AC075-2S Receiver logic board assy.
Complete with: Logic board, end panel w/all labels, light socket
18 41C6661 Wire harness assy.
19 41D180-1 End panel w/all labels
NOT SHOWN
41A2826 Motor shaft bearing kit
41A2825 Opener assembly hardware
kit (includes screws not designated by a number in illustration)
LIMIT SWITCH
ASSEMBLY
Grey Wire
Yellow Wire
37
Page 38

ACCESSORIES

1702LM
41A5281
377LM
395LM
378LM
Outside Quick Release:
Required for a garage with NO access door. Enables homeowner to open garage door manually from outside by disengaging trolley.
Extension Brackets:
(Optional) For safety sensor installation onto the wall or fl oor.
Wireless Keyless Entry with Security
Enables homeowner to operate garage door opener from outside by entering a password on a specially designed keyboard. Also can add a temporary password for visitors or service persons. This temporary password can be limited to a programmable number of hours or entries.
Remote Light Control :
Enables homeowner to turn on a lamp, television or other appliance from their car with their garage door opener remote or from anywhere in their home with an additional LiftMaster Security
Wireless Door Control :
Push bar, light feature and auxiliary button. Includes battery.
373W
Designer Burled Walnut 3-Button Remote Control with Security
®
:
Includes visor clip.
370LM 3-Button Mini-Remote Control with
Security
®
:
With key ring and fastening strip.
915LM
Garage Door Monitor:
Security for the largest door of your home!
®
:
Tells you if your garage door is open or closed. Monitors up to 4 garage doors by adding additional sensor modules.
916LM
Garage Door Monitor Sensor:
Additional accessory sensor for homes with multiple garage doors.
902LM/903LM
2 & 3 Door Multi-Function Wall Control:
Ideal for homes with up to three garage doors. Combine up to three controls into one wall control panel for a neat compact
®
remote.
appearance. Enhanced functions include Lock Feature to lock out outside radio signals while you are away from home and turn opener lights on or off from the door control.
975LM
Laser Park Assist:
Laser enables homeowners to precisely park vehicles in the garage.
990LM
Surge Protector:
The Garage Door Opener Surge Protector is designed to protect LiftMaster® garage door openers against damage from lightning and power surges.
38
373P
373LM
3-Button Security® Remote Control :
Includes visor clip.
3-Button Security® Remote Control :
Includes visor clip.
Page 39
NOTES
39
Page 40
LIFTMASTER® SERVICE IS
ON CALL
OUR LARGE SERVICE ORGANIZATION
SPANS AMERICA

HOW TO ORDER

REPAIR PARTS
Selling prices will be furnished on request, or parts
will be shipped at prevailing prices and you will be
billed accordingly.
INSTALLATION AND SERVICE INFORMATION IS
AS NEAR AS YOUR TELEPHONE. SIMPLY DIAL
OUR TOLL FREE NUMBER:
1-800-528-9131
WHEN ORDERING REPAIR PARTS, ALWAYS
GIVE THE FOLLOWING INFORMATION:
PART NUMBER
PART NAME
MODEL NUMBER
www.liftmaster.com
For professional installation, parts and service,
contact your local LIFTMASTER/CHAMBERLAIN dealer. Look for him in the Yellow Pages, or call our Service number for a list of dealers in your area.
SERVICE INFORMATION TOLL FREE NUMBER:
ADDRESS ORDERS TO:
THE CHAMBERLAIN GROUP, INC.
Technical Support Group
6050 S. Country Club Road
Tucson, Arizona 85706
1-800-528-9131
LIFTMASTER® GARAGE DOOR OPENER FIVE-YEAR LIMITED WARRANTY
LIFETIME MOTOR AND BELT LIMITED WARRANTY
The Chamberlain Group, Inc. (“Seller”) warrants to the fi rst retail purchaser of this product, for the residence in which this product is originally installed, that it is free from defect in materials and/or workmanship for a period of fi ve years from the date of purchase [and that the motor and belt are free from defect in materials and/or workmanship for the lifetime of the product]. The proper operation of this product is dependent on your compliance with the instructions regarding installation, operation, maintenance and testing. Failure to comply strictly with those instructions will void this limited warranty in its entirety.
If, during the limited warranty period, this product appears to contain a defect covered by this limited warranty, call 1-800-528-9131, toll free, before dismantling this product. Then send this product, pre-paid and insured, to our service center for warranty repair. You will be advised of shipping instructions when you call. Please include a brief description of the problem and a dated proof-of-purchase receipt with any product returned for warranty repair. Products returned to Seller for warranty repair, which upon receipt by Seller are confi rmed to be defective and covered by this limited warranty, will be repaired or replaced (at Seller’s sole option) at no cost to you and returned pre-paid. Defective parts will be repaired or replaced with new or factory-rebuilt parts at Seller’s sole option.
ALL IMPLIED WARRANTIES FOR THE PRODUCT, INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, ARE LIMITED IN DURATION TO THE FIVE YEAR LIMITED WARRANTY PERIOD SET FORTH ABOVE [EXCEPT THE IMPLIED WARRANTIES WITH RESPECT TO THE MOTOR AND BELT, WHICH ARE LIMITED IN DURATION TO THE LIFETIME LIMITED WARRANTY PERIOD FOR THE MOTOR AND BELT], AND NO IMPLIED WARRANTIES WILL EXIST OR APPLY AFTER SUCH PERIOD. Some States do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you. THIS LIMITED WARRANTY DOES NOT COVER NON-DEFECT DAMAGE, DAMAGE CAUSED BY IMPROPER INSTALLATION, OPERATION OR CARE (INCLUDING, BUT NOT LIMITED TO ABUSE, MISUSE, FAILURE TO PROVIDE REASONABLE AND NECESSARY MAINTENANCE, UNAUTHORIZED REPAIRS OR ANY ALTERATIONS TO THIS PRODUCT), LABOR CHARGES FOR REINSTALLING A REPAIRED OR REPLACED UNIT, REPLACEMENT OF BATTERIES AND LIGHT BULBS OR UNITS INSTALLED FOR NON-RESIDENTIAL USE.
THIS LIMITED WARRANTY DOES NOT COVER ANY PROBLEMS WITH, OR RELATING TO, THE GARAGE DOOR OR GARAGE DOOR HARDWARE, INCLUDING BUT NOT LIMITED TO THE DOOR SPRINGS, DOOR ROLLERS, DOOR ALIGNMENT OR HINGES. THIS LIMITED WARRANTY ALSO DOES NOT COVER ANY PROBLEMS CAUSED BY INTERFERENCE. ANY SERVICE CALL THAT DETERMINES THE PROBLEM HAS BEEN CAUSED BY ANY OF THESE ITEMS COULD RESULT IN A FEE TO YOU.
UNDER NO CIRCUMSTANCES SHALL SELLER BE LIABLE FOR CONSEQUENTIAL, INCIDENTAL OR SPECIAL DAMAGES ARISING IN CONNECTION WITH USE, OR INABILITY TO USE, THIS PRODUCT. IN NO EVENT SHALL SELLER’S LIABILITY FOR BREACH OF WARRANTY, BREACH OF CONTRACT, NEGLIGENCE OR STRICT LIABILITY EXCEED THE COST OF THE PRODUCT COVERED HEREBY. NO PERSON IS AUTHORIZED TO ASSUME FOR US ANY OTHER LIABILITY IN CONNECTION WITH THE SALE OF THIS PRODUCT.
Some states do not allow the exclusion or limitation of consequential, incidental or special damages, so the above limitation or exclusion may not apply to you. This limited warranty gives you specifi c legal rights, and you may also have other rights which vary from state to state.
© 2011, The Chamberlain Group, Inc. 114A4257 All Rights Reserved
Loading...