Gate Operator Site Plan
Model CSW24U
VEHICULAR SWING GATE OPERATOR
Solar Panel
To replace or add a solar panel to the operator application. Requires a solar battery harness. 20W minimum to 60W maximum.
ACCESSORY OVERVIEW
Entrapment Protection Devices
This operator contains an inherent (internal) entrapment protection system and REQUIRES the addition of a LiftMaster external monitored entrapment protection system (non-contact photoelectric sensor or contact edge sensor) for EACH entrapment zone prior to gate movement. Model LMRRU is provided with operator. See back page.
Plug-In Loop Detector
Includes 8 sensitivity settings and boost, ensures vehicles are easily identifi ed.
Batteries
7AH
Standard 7 AMP-Hour Battery, 12 Vdc, to replace original batteries provided with operator. Reuse existing harnesses.
Upgrade 33 AMP-Hour Battery, 12 Vdc. Ideal for extended battery backup. Two required. Requires battery tray and solar battery harness.
Heater Kit
Protects system to -40° F.
MODEL CSW24U
ORDER SUMMARY
Customer: Date:
Project:
Architect/Engineer:
Contractor:
Gate Length (ft.): Gate Weight (lbs.):
Solar (Y/N):
Power Source (120 or 240 VAC):
LiftMaster gate operators comply with UL 325 standards. IMPORTANT: To be compliant with UL 325 and industry safety guidelines, LiftMaster qualifi ed monitored external entrapment protection devices such as photoelectric sensors or edge sensors are required to be installed with this operator.
ACCESSORY CHECKLIST
ACCESSORY MODEL
Entrapment Protection Devices . . . . . . . . . . . . . . . . . . . . . . . . . . See back page
Plug-In Loop Detector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . LOOPDETLM
Universal DIP Single Button Remote Control . . . . . . . . . . . . . . . 811LM
Universal DIP Three Button Remote Control . . . . . . . . . . . . . . . 813LM
®
Security+ 2.0
Security+ 2.0
Wireless Commercial Keypad . . . . . . . . . . . . . . . . . . . . . . . . . . . KPW250
LiftMaster Internet Gateway . . . . . . . . . . . . . . . . . . . . . . . . . . . . 828LM
7AH Battery . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29-NP712
33AH Batteries . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A12330SGLPK
Heater Kit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . HTR
SOLAR
10 Watt 12V Solar Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SP10W12V
20 Watt 12V Solar Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SP20W12V
Battery Tray for 33AH batteries . . . . . . . . . . . . . . . . . . . . . . . . . . K10-36183
Solar Battery Harness . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . K94-37236
2-Button Remote Control . . . . . . . . . . . . . . . . . . 892LT
®
4-Button Remote Control . . . . . . . . . . . . . . . . . . 894LT
Universal DIP Single-Button and 3-Button Remote Control
These remote controls are ideal for applications such as gated communities or commercial applications requiring a large number of remotes for a common entrance.
© 2016 LiftMaster All Rights Reserved
For more information:
845 Larch Ave., Elmhurst, IL 60126
www.devancocanada.com
LiftMaster.com
PAS006
or call toll free at 855-931-3334
2-Button and 4-Button Security+ 2.0® Learning Remote Controls
These remote controls are ideal for gated communities. One button can control a gate operator and the other(s) can control a garage door. It can also be programmed to different codes and frequencies.
Wireless Commercial Keypad
Security+ 2.0® compatible.
LiftMaster® Internet Gateway
Internet enabled accessory which connects to the computer and allows you to monitor and control gate operators and lighting accessories enabled by MyQ
®
technology.
Page 2
ENTRAPMENT PROTECTIONGATE CONSTRUCTION & SITE PREPARATION INSTALLATION OVERVIEW
Earth Ground Rod Check national and local
codes for proper depth
Maximum gate weight/length:
There should only be a maximum of 4" (10.2 cm) from the center of the hinge to the edge of the post or
1200 lbs. (544.3 kg)/12 foot (3.7 m) 800 lbs. (362.9 kg)/16 foot (4.9 m) 600 lbs. (272.2 kg)/18 foot (5.5 m)
column. If the distance is greater than 4" (10.2 cm) entrapment protection for this area is required.
Gate MUST swing freely and be supported entirely by its hinges.
Gate MUST be level. Gate and gate post MUST be plumb.
Warning Placard on both sides of gate.
High and Low Voltage UL approved conduit. Power and control wiring MUST be run in separate conduits
Gate MUST NOT hit or drag across
Remove ANY/ALL wheels from the bottom of gate.
ground.
24" (61 cm)
28" (71 cm)
Gate MUST have a smooth bottom edge, no protrusions should exist.
6" (15.2 cm) Above Ground
OPERATOR DIMENSIONS
4.5" (11.4 cm)
4" (10.2 cm)
6.5"
(16.5 cm)
27.66"
(70.3 cm)
18.77" (47.7 cm)
14.8" (37.6 cm)
25" (63.5 cm)
10" (25.4 cm)
1.5"
(3.8 cm)
INSIDE PROPERTY
STANDARD DUAL GATE INSTALLATION
OPERATOR POWER SOURCE
Wire Gauge 120 Vac 240 Vac
14 130 feet (40 m) 260 feet (79 m)
12 205 feet (62 m) 410 feet (125 m)
10 325 feet (99 m) 650 feet (198 m)
8 520 feet (158 m) 1040 feet (316 m)
6 825 feet (251 m) 1650 feet (503 m)
4 1312 feet (400 m) 2624 feet (800 m)
NOTE: Use copper conductors ONLY.
Photoelectric Sensors
Outside
Property
5.5" (13.97 cm)
1" (2.5 cm)
(conduit)
10" (25.4 cm)
15" (38.1 cm)
24" (60.9 cm)
NOTE: Wired connection in a dual gate setup is optional. Operators can be setup for wireless dual gate communication.
Warning Sign
MOUNTING FOOTPRINT
3" (7.6 cm)
20" (50.8 cm)
35.5" (90.2 cm)
13.6" (34.5 cm)
12.2" (31 cm)
28" (71.1 cm)
14.82" (37.6 cm)
46" (116.8 cm)
(5.1 cm)
29.5" (74.93 cm)
Operator
6.1"
(15.5 cm)
2"
11" (27.9 cm)
24"
(60.9 cm)
2.49" (6.3 cm)
This operator contains an inherent (internal) entrapment protection system and REQUIRES the addition of a LiftMaster external monitored entrapment protection system (non-contact photoelectric sensor or contact edge sensor) for EACH entrapment zone prior to gate movement. An entrapment zone is every location or point of contact where a person can become entrapped between a moving gate and a stationary object. Your application may contain one or many entrapment zones. System includes six monitored entrapment protection inputs capable of covering all entrapment zones. Use only LiftMaster approved entrapment protection devices.
NON-CONTACT SENSORS
Entrapment protection is required for the area between the open gate and the operator. Entrapment protection is required for the area between the gate and the curb.
Outside
Property
Inside
Property
14" (35.6 cm)
Model LMTBU
LiftMaster Monitored Through Beam Photoelectric Sensor
Model LMRRU
LiftMaster Monitored Retro-Refl ective Photoelectric Sensor
NOTE: LMRRU is provided with the operator
Model CPS-UN4
LiftMaster Commercial Protector System
®
CONTACT SENSORS (EDGE SENSORS)
Model LMWEKITU
LiftMaster Monitored Wireless Edge Kit
28" (71.1 cm)
(Transmitter and Receiver)
Model LMWETXU
LiftMaster Monitored Wireless Edge Transmitter
Model L50
Large Profi le Monitored Edge
Model L50E
Large Profi le Ends Kit (pair, pack of 10)
Model L50CHP
Channel for both Large and Small Profi les ­PVC (8 ft., pack of 10)
Model L50CHAL
Channel for both Large and Small Profi les ­Aluminum (10 ft., pack of 8)
For a gate operator utilizing a contact sensor, if the bottom edge of a swing gate is greater than 6 inches (15.2 cm) above the ground at any point in its arc of travel, one or more contact sensors shall be located on the bottom edge.
(82 ft. roll)
Model S50
Small Profi le Monitored Edge (82 ft. roll)
Model S50E
Small Profi le Ends Kit (pair, pack of 10)
Models L504AL, L505AL, and L506AL
Large Profi le Edge - Aluminum Channel (4 ft, 5 ft, 6 ft)
Models S504AL, S505AL, and S506AL
Small Profi le Edge - Aluminum Channel (4 ft, 5 ft, 6 ft)
Model ETOOL
Edge Cutting Tool
If utilizing a contact sensor as entrapment protection, one or more contact sensors shall be located on the inside and outside leading edge of a swing gate.
For more information: www.devancocanada.com or call toll free at 855-931-3334
Concrete Pad
Below the frost line. Check all national and local codes. Minimum of 24" (61 cm) recommended in regions with no frost line.
Earth Ground Rod Check national and local codes for proper depth
Edge Sensor
Inside
Property
Water Tight Conduit (Not provided) NOTE: Power and control wiring MUST be run in separate conduits.
Inside
Property
Outside
Property
Inside
Property
Outside
Property