Dimensions 2
EL25 Installation 3
Rotating the Keypad for Vertical Mounting 3
Unlocking/Locking EL2000 4
EL2000 Installation 5
Wire Type
Wire Connections to Unit (Factory Settings for Relays) 6
Wire Specs and Run Distances 7
Power Wire Specs and Run Distances 7
Grounding the Unit
Grounding the Unit 8
Phone Lines
Wiring 1 Unit to Telco Line 9
Wiring Multiple Units to Telco Line 10
Wiring with No Telco Line 11
Wiring to Dedicated Telco Line 12
Wiring to an Internal Phone System 13
Connection to an NPBI System 14
External Devices
Wiring a Door Strike Lock 15
Wiring a Maglock 15
Wiring a Gate Operator 16
Wiring a Key Switch/PIR/REX 16
Wiring a Door Sensing Device 17
Wiring the AutoCall Feature 17
Wiring a Radio Frequency Module 18
Wiegand Card Reader / Keypad 18
Wiring a Postal Lock Switch 19
Wiring an Internal Camera (CCTV) 19
Power
Wiring Power to the Unit 20
Powering up and Checking the LEDs 20-21
Troubleshooting 22
Repair Parts
Repair Parts 23-24
“Your” Set-Up
“Your” System Diagram and Wiring Configuration 25-26
Accessories 27
FCC and DOC
FCC and DOC Requirements 28
Page 1
f
6 in.
Dimensions
EL25 Units
Dimensions
15 in.
3-1/16 in.
3-1/16 in.
5-1/8 in.
10-1/4 in.
3 in.
1-1/16 in. Conduit Hole
Mounting Holes (4)
for 5/16 in.
Caution! A Static Discharge can Damage Circuit Boards
AUG 10, 2005
WELCOME
EL2000 Units
Knockouts for 5/16 in.
Knockouts
9-1/2 in.
3-1/16 in.
3-15/16 in.
or 3/8 in.
9 in.
7 in.
3-1/16 in.
1-1/2 in.
1/2 in.
12 in.
Page 2
1-5/8 in.
2 in.
1-5/8 in. Conduit Hole
6 in.
1-15/16 in.
1
Unlock Unit.
4
Line up Notch with
Screw and Push
Hinge Out.
Screw
EL25 Installation
Caution! A Static Discharge can Damage Circuit Boards
NOTE: This unit is for surface mount applications only.
3
Unplug the 2 Main Harnesses.
Notch
2
Carefully Lift Cover Up
then Slide Out on Hinges.
5
Remove Back Mounting Plate from Cover.
EL25 Installation
DO NOT pinch wires when
closing and locking the unit.
DO NOT overload the removable
terminal block connectors.
One wire per hole.
Rotating the Keypad for Vertical Mounting
Caution! A Static Discharge can
Damage Circuit Boards
1
Disconnect all Plugs from Main Circuit Board and
Remove Board. (4 Screws)
2
Remove Bracket. (4 Screws)
3
Rotate Keypad 90 Degrees Clockwise.
4
Reverse the Sequence to Reassemble Unit.
ONLY Vertical
Mounting Position
Main Circuit
1
Board
For EL25 ONLY
Bracket
2
Keypad
3
NOTE: Bracket notch lines up
with ribbon cable on keypad.
2. While maintaining
pressure, turn key
clockwise.
3. Open cover.
Locking EL2000
1. Turn key counter clockwise to lock
1
position.
2. Close cover.
2
3. Apply pressure to left-side until you
hear a “click” sound.
4. Apply pressure to right-side of unit
until you hear a “click” sound.
3
4
Unlocking/Locking EL2000
Page 4
#
1
2
3
?
4
5
6
7
8
9
*
0
#
#
#
1
2
3
4
5
6
7
8
9
0
*
#
?
#
EL2000 Installation
NOTE: This unit is for surface and recessed mount ONLY.
1
3
Unplug the 2 Main Harnesses (Optional).
Unlock Unit.
2
Open Cover.
4
Slide Front Cover Out of
Hinges (Optional).
EL2000 Model Installation
5
Knock-out Desired
Mounting Plugs
Using Punch.
6
Mount Back Housing
to Wall or Pedestal.
Page 5
Wire Connections to the Unit
20-Pin
to Main Board
14-Pin
to Main Board
IO Output Board
IO Input Board
J2
J3
LED 2
LED 1
RELAY 1
RELAY 2
RELAY 3
RELAY 4
8
9
DOOR
STAT 4
EXIT
REQ 4
COM
4
3
2
1
5
6
7
10
11
12
13
DOOR
STAT 3
EXIT
REQ 3
COM
DOOR
STAT 4
EXIT
REQ 2
COM
DOOR
STAT 1
EXIT
REQ 1
COM
J5
J7
J6
J4
POSTAL
AUTO
J1
POWER
12VAC/DC
J3
J5
J4
J1
NO
NC
C
NO
NC
C
NO
NC
C
NO
NC
C
LED 4
LED 3
RES
TELCO
J6
J8
Input Board Connections
1. Door 1 Exit Request and Door Status
2. Door 2 Exit Request and Door Status
3. Door 3 Exit Request and Door Status
4. Door 4 Exit Request and Door Status
5. Postal Lock Input
Wire Connections to the Unit
6. AutoCall Input
7. Power 12 VAC Input
Output Board Connections
8. Resident Tip/Ring
9. Telco Tip/Ring
10. Relay 4, NO, NC, COM
11. Relay 3, NO, NC, COM
12. Relay 2, NO, NC, COM
13. Relay 1, NO, NC, COM
NOTE: All relays are factory set to “Strike”
and “10 sec.”
Page 6
DO NOT overload the removable
terminal block connectors. One wire
per hole.
Wire Specs and Run Distances
Use this chart to pull wires in preparation of your installation:
Description of Wire Run
Wire Specification
Maximum Distance
Page
Grounding the Chassis
Residence and Telco Phone Lines
Door Strike
Magnetic Lock
Dry Contact Closure (Most Gate Operators)
Exit Request (REX) / Auxiliary Open Devices
AutoCall
Door Status Sensor
Barium Ferrite and Wiegand Readers
Proximity Readers
Radio Frequency Module (RF)
Postal Lock
12 AWG Copper
2 Twisted Pairs
18-24 AWG Shielded
2-Conductor
18-22 AWG Shielded
2-Conductor
18-22 AWG Shielded
2-Conductor
18-24 AWG Shielded
2-Conductor
18-24 AWG Shielded
2-Conductor
18-24 AWG Shielded
2-Conductor
18-24 AWG Shielded
5-Conductor
18-24 AWG Shielded
5-Conductor
22 AWG Shielded
RG-6 Coaxial
75 ohm
2-Conductor
18-24 AWG Shielded
12 feet
5000 feet*
500 feet
500 feet
100 feet
8
9-14
15
15
16
16
17
17
18
18
18
19
Wire Specs and Run Distances
1000 feet
CCTV Camera (Optional)
NOTE: Use metal conduit - run wires in metal conduit instead of PVC pipe. Wires run in PVC conduit may
experience interference. Metal conduits also add extra protection against lightning strikes.
Never run Telco Wires and High Voltage wires in the same conduit. The high voltage may interfere with the Telco
Wires, possibly causing the system to malfunction.
* Total distance from Telco to residence regardless of number of units in chain.
Single Conductor
RG-59u Coaxial
(Monitor with a .25 volt
p-p composite signal
sensitivity)
19
Power Wire Specs and Run Distances
Distance at 65° C
Under 50 Feet
50 - 100 Feet
100 - 300 Feet
300 - 500 Feet
Always provide power from a dedicated source. Plug provided transformer into an outlet wired to its own 10 AMP
minimum circuit breaker. This will prevent two problems:
• Other equipment cannot introduce spikes, noise, surges or dips into the power circuit that will affect the system.
• The system’s operation will not be affected if any other equipment develops a short circuit across the power line.
CAUTION: Not responsible for conflicts between the information listed in the above table and the requirements of
your local building codes. The information is for suggested use only. Check your local codes before installation.
12Vac Power (Included)
2-Conductor Shielded
24 AWG MIN
20 AWG MIN
16 AWG MIN
14 AWG MIN
12Vdc Power (Not Provided)
2-Conductor Shielded
24 AWG MIN
20 AWG MIN
16 AWG MIN
14 AWG MIN
Page 7
Grounding the Units
Other Ground Sources
Within 12 ft of Unit
Green Ground
Wire
Earth Ground Rod
Ground to
Existing
Electrical
System
Electrical
Panel
Ground to
Metallic Cold
Water Pipe
12 ft Maximum
12 AWG Minimum
1
2
3
4
5
6
7
8
9
AUG 10, 2005
WELCOME
1
2
3
4
10
11
5
6
7
8
9
10
12
11
OR
NOTE: Keep ground wire as
straight as possible.
Ensure that the system is grounded properly. The units contain a number of static sensitive components that can
be damaged by static discharge.
IMPORTANT: An Earth Ground Rod is Strongly
Recommended and should be no further than 12
feet from the unit and use a minimum of 12
gauge wire in most cases. The type and length of
earth ground rods vary by region. Contact the
building inspector’s office in the municipality
where you plan to install the unit for correct
grounding materials and installation
procedures.
Before digging, contact your local
utility companies, to avoid
Grounding the Units
damaging gas, power, or other
underground utility lines.
DO NOT ground the units to a
pedestal post (gooseneck) if
one is used.
Page 8