Chamberlain 1000SDC 1-3HP, 2000SDC 1-2HP User Manual

Page 1
Page 2

Contents

Safety alert symbol review ...........................................2
Safety information and precautions..............................3
Testing your garage door for binding & balance..........3
Hardware supplied........................................................3
Carton inventory ...........................................................4
Illustration of sectional door installation .....................5
Illustration of one-piece door installation.....................5
Fasten rail to power unit .............................................6
Install the trolley.........................................................6
Attach the rail brackets ...............................................7
Installation safety instructions ....................................7
Installation section - pages 8 – 23
Determine the header bracket location
Sectional door ...........................................................8
One-piece door..........................................................9
Install the header bracket..........................................10
Attach the rail to the header bracket .........................11
The Protector System
®
.............................................12
Install the safety reversing sensor.............................13
Position the opener....................................................15
Hang the opener........................................................16
Install the door control and connect all wires...........17
Electrical requirements .............................................18
Complete the safety reversing sensor installation.....18
Install the lights and lens ..........................................19
Attach the manual release rope and handle...............19
Fasten the door bracket (sectional door)...................20
Fasten the door bracket (one-piece door)..................21
Connect door arm to trolley (sectional door)............22
Connect door arm to trolley (one-piece door)...........23
Adjustment section - pages 24 – 26
Travel limit adjustments............................................24
Force adjustments .....................................................25
Test the Protector System
®
........................................26
Test the safety reverse system ..................................26
Operation safety instructions ......................................27
Care of your opener ....................................................27
Maintenance schedule.................................................27
Operation of your opener............................................28
Receiver & remote control programming...................29
Having a problem?......................................................30
Repair parts, rail assembly..........................................32
Repair parts, installation .............................................32
Repair parts, power unit..............................................33
Accessories .................................................................34
Index ...........................................................................35
How to order repair parts............................................36
Warranty......................................................................36
Start by reviewing these important safety alert symbols:
When you see these Safety Symbols on the following pages, they will alert you to the possibility of or death if you do not comply with the corresponding instructions. The hazard may come from something mechanical or from electric shock. Read the instructions carefully.
serious injury
Mechanical Electrical
When you see this Safety Symbol on the following pages, it will alert you to the possibility of damage to your garage door and/or the garage door opener if you do not comply with the corresponding instructions. Read the
instructions carefully.
This garage door opener is designed and tested to offer safe service provided it is installed, operated, maintained and tested in strict accordance with the safety instructions contained in this manual.
2
Page 3
To avoid damage to the garage door and opener, disable locks before installing and operating the opener . Use a wood screw or nail to hold locks in the "open" (unlocked) position.
Operation at other than 120V 60 Hz will cause opener malfunction and damage.
Safety Reversing Sensor
Installation
Lag Screw 1/4 x 1-1/2" (4) Hex Screw 1/4-20 x 1-1/2" (2) Carriage Bolts 1/4" - 20 x 1/2" (4) Screw #10 - 32 x 3/8" (4) Lock Nut 1/4" - 20 (4) Lock Nut #10 x 32 (4) Wing Nut (2) Insulated Staples (20)
Rail Assembly
Coupling Sleeve (1) Hex Screw 1/4"-20 x 5/8" (4) Nut 1/4" - 20 (4)
Identify the type and height of your door, any special conditions that exist, and any additional materials that may be required.
Test Your Door for Balance
Before you begin, complete the following test to make sure your door is balanced, and is not sticking or binding:
• Lift the door about halfway as shown. Release the door. It should stay in place, supported entirely by its springs.
• Raise and lower the door to see if there is any binding or sticking.

Hardware Supplied

Sectional Door
One-Piece
Door

Safety Information and Precautions

Opener Installation
Hex Screw 5/16"-18 x 7/8" (4) Lag Screw 5/16"-9 x 1-5/8" (2) Lag Screw 5/16"-18 x 1-7/8" (2) Carriage Bolt 5/16"-18 x 2-1/2" (2) Clevis Pin 5/16" x 2-3/4" (1) Clevis Pin 5/16" x 1-1/4" (1) Clevis Pin 5/16" x 1" (1) Nut 5/16" - 18 (6) Lock Washer 5/16" (6) Screw 6AB x 1" (2) Insulated Staples (10) Ring Fastener (3) Handle Dry Wall Anchors (2) Rope
An unbalanced gara ge door might not re verse when required and someone under the door could be seriously injured or killed.
If your garage door binds, sticks or is out of balance, call for professional garage door service.
springs, cables, pulleys, brackets, and their hardware are under extreme tension and can cause serious injur y or death.
yourself!
Ropes left on a gara ge door could cause someone to become entangled and killed.
connected to the door before installing and operating the opener.
Do not tr y to loosen, mo ve or adjust them
Garage doors, door
Remove all r opes
3
Page 4
Page 5
Before you begin, survey your garage area to see whether any of the conditions below apply to your installation.
SECTIONAL Door or
ONE-PIECE Door with Track Installation
Horizontal and vertical reinforcement
is needed for lightweight garage doors
(fiberglass, steel, aluminum, door with glass panels, etc.).
See page 20 for details.
Header Wall
— — — — — — — —
Door Center
Extension Spring
OR
Torsion Spring
Safety
Reversing
Sensor
FINISHED CEILING
Support bracket & 
fastening hardware
is required.
See page 13.
One-Piece Door-Extension Spring
Door
OR
 Header
Wall
Track
Access Door
Floor must be level
across width of door
Safety Reversing Sensor

ONE-PIECE Door Without Track Installation

Header
Wall
FINISHED CEILING
Support bracket
& fastening
hardware is required.
See page 13.
Access Door
Safety
Reversing
Sensor
Gap between floor and bottom of
Safety Reversing Sensor
door must not exceed 1/4".
You may find it helpful to refer back to this page as you proceed with the installation of your opener.
5
Page 6
Rail
Sprocket
Rail
Assembly
Trolley
Coupling
Rail/Power Unit
Bracket
Lock Nuts
1/4"-20
Power Unit
Sprocket
Opener
Chassis
Foam Packaging
Hex Screws 1/4"-20x5/8"
Assembly Section: Pages 6 - 7
ASSEMBLY STEP 1

Fasten the Rail To the Power Unit

NOTE: To aid in assembly and installation, replace the foam packing around the power unit. Remove it after Installation Step 5.
• Working on a level surface, align the rail assembly with
the power unit, as shown.
• Slip the coupling over the rail sprocket.
• Slide the rail through the power unit bracket until the
coupling fits securely over the power unit sprocket.
• Align the two screw holes in the rail with those in the
power unit bracket. Insert two 1/4"-20x5/8" hex screws and lock nuts. Tighten securely with a 7/16" socket wrench.
ASSEMBLY STEP 2

Install the Trolley

As illustrated above, slide the trolley onto and along the bottom of the rail until it snaps firmly in place. Be certain
to install it facing correctly: the trolley release arm must be horizontal (lock position), with its arrow pointed away from the power unit.
Hardware Shown Actual Size
1/4" - 20
Lock Nut
1/4" - 20 x 5/8"
Hex Screw
6
Page 7
ASSEMBLY STEP 3

Attach the Rail Brackets

• Align rail brackets to end of rail assembly, as shown.
• Insert two 1/4"-20 x 5/8" hex screws and lock nuts. Tighten securely with a 7/16" socket.
Hardware Shown Actual Size
1/4" - 20 x 5/8"
Hex Screw
1/4" - 20
Lock Nut
1/4"-20x5/8
Hex
Screws
Rail 
Brackets
Rail
1/4"-20
Lock Nuts
You have now finished assembling your garage door opener. Please read the following warnings before proceeding to the installation section:

IMPORTANT INSTALLATION INSTRUCTIONS

WARNING
WARNING
To reduce the risk of severe injury or death to persons:
1. READ AND FOLLOW ALL INSTALLATION INSTRUCTIONS
2. Install only on a properly balanced and lubricated garage door. An improperly balanced door may not reverse and could result in severe injury or death. Repairs to cables, spring assemblies and other hardware must be made by a professional service person before installing opener.
3. Disable all locks and remove all ropes connected to the garage door before installing the opener. Ropes
connected to a garage door can cause entanglement and death.
4. If possible, install door opener 7 feet or more above floor with the manual release handle mounted 6 feet above the floor.
5. Do not connect the opener to power source until instructed to do so.
6. Locate the Door Control within sight of the door at a minimum height of 5 feet where small children cannot reach and away from all moving parts of the door.
7. Install the User Safety Instruction Label on the wall adjacent to the control button and the Maintenance Instruction Label in a prominent location on the inside of the garage door.
8. Upon completion of the installation, the door must reverse when it comes in contact with a one-inch high object or a 2x4 laid flat on the floor.
9. Do not wear watches, rings or loose clothing while installing or servicing an opener. Jewelry or loose clothing can be caught in the mechanism of the garage door or the opener.
7
Page 8
Installation Section: Pages 8 – 23
Installation Step 1

Determine Header Bracket Location

Installation procedures vary according to garage door types. Follow the instructions which apply to your door.
SECTIONAL Door or
ONE PIECE Door with Track
Finished
Ceiling
2x4
Header
Wall
Vertical
Guideline
Vertical
Guideline
Structural
Supports
WARNING
If the header bracket is not rigidly fastened to a structural support on the header wall or ceiling, the safety reverse system may not work properly (see page
26).
The door might not reverse when required, and
could cause serious injury or death.
The garage door springs, cables, pulleys, brackets and their hardware are under extreme tension.
to loosen, move or adjust them yourself. Serious personal injury or death could result.
professional garage door service.
• Close the door and mark the inside vertical centerline of the garage door.
• Extend the line onto the header wall above the door.
Remember, you can fasten the header bracket within 2 feet of the left or right of the door center only if a torsion spring or center bearing plate is in the way; or you can attach it to the ceiling (refer to page 10) when clearance is minimal. (It may be mounted on the wall upside down if necessary, to gain approximately 1/2".)
If you need to install the header bracket on a 2x4 (on wall or ceiling), use lag screws (not supplied) to securely fasten the 2x4 to structural supports as shown here and on page 9.
Do not attempt
Call for
• Open your door to the highest point of travel as shown. Draw an inter­secting horizontal line on the header wall 3" above the high point. This height will provide travel clearance for the top edge of the door.
Proceed to Step 2, page 10.
Ceiling
Header
Wall
3"
Highest Point
of Travel
Door
Sectional door
with curved track
8
Track
Header
Wall
3"
Highest Point
Door
One-piece door
with horizontal track
Track
of Travel
Page 9

ONE-PIECE Door Without Track

Read the Safety Instructions on page 8. They also apply to doors without tracks.
• Close the door and mark the inside vertical centerline of your garage door. Extend the line onto the header wall above door.
If headroom clearance is minimal, you can install the header bracket on the ceiling. See page 10.
If you need to install the header
bracket on a 2x4 (on wall or ceiling), use lag screws (not supplied) to securely fasten the 2x4 to structural supports as shown.
Header Wall
Highest Point
of Travel
Header Wall
Vertical
Centerline
2x4
Vertical Centerline of Garage Door
Header
Wall
Unfinished
Ceiling
Structural Supports
2x4
Header Support
OPTIONAL CEILING MOUNT
FOR HEADER BRACKET
Highest Point
of Travel
Door
Jamb
Hardware
Distance
Floor
One-piece door without track
jamb hardware
• Open your door to the highest point of travel as shown. Measure the distance from the top of the door to the floor. Subtract the actual height of the door. Add 8" to the remainder. (See Example).
• Close the door and draw an intersecting horizontal line on the header wall at the determined height.
If the total number of inches exceeds the height available in your garage, use the maximum height possible, or refer to page 10 for ceiling installation.
Door
Distance
Pivot
Floor
One-piece door without track
pivot hardware
EXAMPLE
Distance from top of door
(at highest point of travel) to floor................................92"
Actual height of door...................................................-88"
Remainder.......................................................................4"
Add...............................................................................+8"
Bracket height on header wall....................................=12"
(Measure UP from top of CLOSED door.)
Proceed to Step 2, page 10.
9
Page 10
Installation Step 2
Hardware Shown Actual Size

Install the Header Bracket

You can attach the header bracket either to the wall above the garage door, or to the ceiling. Follow the instructions which will work best for your particular requirements.
Fastening the Header Bracket to the Wall
• Center the bracket on the vertical guideline with the bottom edge of the bracket on the horizontal line as shown (with the arrow pointing toward the ceiling).
• Mark either set of bracket holes (do not use the holes designated for ceiling mount). Drill 3/16" pilot holes and fasten the bracket securely to a structural support with the hardware provided.
Fastening the Header Bracket to the Ceiling
• Extend the vertical guideline onto the ceiling as shown.
• Center the bracket on the vertical mark, no more than 6" from the wall. Make sure the arrow is pointing toward the wall. The bracket can be mounted flush against the ceiling when clearance is minimal.
• Mark holes designated for ceiling mount only. Drill 3/16" pilot holes and fasten bracket securely to a structural support with the hardware provided.
10
Page 11
Installation Step 3
Hardware Shown Actual Size

Attach the Rail to the Header Bracket

• Position the opener on the garage floor below the header bracket. Use packing material as a protective base.
If the door spring is in the way you’ll need help. Have someone hold the opener securely on a temporary support to allow the rail to clear the spring.
• Position the rail bracket against the header bracket.
• Align the bracket holes and join with a clevis pin as shown.
• Insert a ring fastener to secure.
11
Page 12
The Protector System
Information you'll need before you begin the installation of the safety reversing sensor
The safety reversing sensor must be connected and aligned correctly before the garage door opener will move in the down direction. This is a required safety device and cannot be disabled.
Installation procedures are the same for sectional and one-piece doors.
Be sure power to the opener is disconnected.
The sending eye transmits an invisible light beam to the receiving eye. The units can be installed on either side of the garage door as long as the sun never shines directly into the receiving eye lens.
Look at the label on the connector end of each case to identify the sensors.
The brackets must be connected and fastened so that the sending and receiving eyes face each other as shown.
If an obstruction breaks the light beam while the garage door is closing, the door will stop and reverse to full open position and the opener lights will flash for 5 seconds.
The brackets must be securely fastened to a solid surface such as the studs on either side of the door, or add a piece of wood at each location if installing in masonry construction. The invisible light beam path must be unobstructed. No part of the garage door (or door tracks, springs, hinges, rollers or other hardware) can interrupt the beam while the door is closing. If it does, use a piece of wood to build out each sensor mounting location to the minimum depth required for light beam clearance.
®
WARNING
Without a properly working safety reversing sensor, persons (particularly children) could be injured or killed by a closing garage door.
instructions. To protect small children, install the safety reversing
sensor so that the beam will be no higher than 4"-6" above the garage floor.
Disconnect power to the garage door opener before installing the safety reversing sensor.
Read and follow all
Sensor
Beam
4-6" max.
above floor
Invisible Light Beam
Protection Area
Facing the door from inside the garage
12
Sensor
Beam
4-6" max.
above floor
Page 13
Installation Step 4

Install the Safety Reversing Sensor (Receiving and Sending Eyes)

Figures 1, 2 and 3 show recommended assembly of bracket(s) and "C" wrap based on the wall installation of the sensors on each side of the garage door as shown on page 12, or on the garage door tracks themselves.
Figures 4 and 5 are variations which may fit your installation requirements better. Make sure the wraps
and brackets are aligned so the sensors will face each other across the garage door.
Garage Wall or Door Track Installation Procedure
Fasten the "C" wraps to the mounting brackets having
square holes, using the hardware shown in 1.
Garage Wall Installation Procedure
• Connect each assembly to a slotted bracket, using the
hardware shown in 2. Note alignment of brackets for
left and right sides of the door.
• Finger tighten the lock nuts.
Use bracket mounting holes as a template to locate and
drill (2) 3/16" diameter pilot holes on both sides of the garage door, 4"-6" above the floor but not exceeding 6" (see warning on page 12).
• Attach bracket assemblies with 1/4"x1-1/2" lag screws as shown in 2.
• Adjust right and left side bracket assemblies to the same distance out from mounting surface. Make sure all door hardware obstructions are cleared. Tighten the nuts securely.
Figure 1
Garage WALL or DOOR TRACK Installation
Mounting Bracket
With Square Holes
#10 - 32
Lock Nuts
"C" Wrap
Figure 2
Garage WALL Installation
1/4 x 1-1/2" Lag Screws
Inside
Garage
Wall
Mounting Bracket
with Slot
1/4" - 20
Lock Nuts
1/4-20 x 1/2" Carriage Bolts
 
Mounting Bracket
with Square Holes
Figure 3
Garage DOOR Track Installation
1/4 " Lock Nuts
Garage
Door Track
Drill 3/8"
Holes
Inside
Garage
Wall
#10-32x3/8"
Screws
(with square shoulder)
"C" Wrap
Mounting Bracket
with Square Holes
Garage Door Track Installation Procedure
Discard slotted bracket. Drill 3/8" holes in each track and fasten securely with hardware as shown in 3.
Hardware Shown Actual Size
#10 - 32 x 3/8"
Screw
Figure 4
#10 x 32 Lock Nut
Alternate Wall Mount
Inside
Garage
Wall
Mounting Bracket
with Slot
Mounting Bracket
with Square Holes
"C" Wrap
Garage
Floor
1/4 x 1-1/2"
Lag Screw
Sensor
Indicator Light
13
1/4-20 x 1/2"
Carriage Bolts
Figure 5
Staples
1/4" - 20 x 1/2"
Carriage Bolts
Alternate Floor Mount
Inside
Garage
Wall
"C" Wrap
Indicator Light
Sensor
Mounting Bracket
"C" Shaped
Wrap
1/4" - 20
Lock Nut
Mounting Bracket
with Square Holes
with Slot
Attach with
concrete anchors
(not provided)
Garage
Floor
Page 14
Page 15
Installation Step 5

Position the Opener

Follow instructions which apply to your door type as illustrated.
SECTIONAL Door or
ONE-PIECE Door with Track
A 2x4 laid flat is convenient for setting an ideal door­to-rail distance.
• Raise the opener onto a stepladder.
You will need help at this point if the ladder is not tall enough.
• Open the door all the way and place a 2x4 laid flat on
the top section beneath the rail.
If the top panel hits the trolley when you raise the door, pull down on the trolley release arm to disconnect the inner and outer sections. The trolley can remain disconnected until Step 12 is completed.
CAUTION
To prevent damage to steel, aluminum, fiberglass or glass panel doors, do not rest the opener on the door without using a 2x4.
Rail
Door
2x4
Foam
Packaging
Trolley
Trolley
Release Arm
ONE-PIECE Door without Track
• With the door fully open and parallel to the floor,
measure the distance from the floor to the top of the door.
• Using a stepladder as a support, raise the opener to the
same distance as the door from the floor (it will be at a slight angle as shown).
• The top of the door should be level with the top of the
opener. Do not position the opener more than 3" above this point.
Header
Bracket
Top of Opener
Foam
Packaging
Top of Door
15
Page 16
Installation Step 6

Hang the Opener

Two representative installations are shown. Yours may be different. Hanging brackets should be angled,
Figure 1, to provide rigid support. On finished ceilings, Figure 2, attach a sturdy metal bracket to structural supports before installing the opener. The bracket and
fastening hardware are not supplied.
Measure the distance from each side of the opener to
the structural support.
• Cut both pieces of the hanging bracket to required
lengths.
Drill 3/16" pilot holes in the structural supports.
• Attach one end of each bracket to a support with
5/16"x1-7/8" lag screws.
• Fasten the opener to the hanging brackets with
5/16" - 18x7/8" screws, lock washers and nuts.
• Check to make sure the rail is centered over the door
(or in line with the header bracket if the bracket is not centered above the door).
• Remove the 2x4. Operate the door manually. If the
door hits the rail, raise the header bracket.
WARNING
The opener could fall and injure someone if it is not properly secured.
structural supports of the garage.
Figure 1
Measure Distance
5/16"-18x7/8"
Hex Screws
5/16" Lock Washers
5/16"-18 Nuts
Fasten the opener securely to
Structural
Supports
Lag Screws
5/16"x1-7/8"
CONTROL
CENTER
Preferred Range of
Bracket Placement
Hardware Shown Actual Size
Lag Screw
5/16"-18 x 1-7/8"
Hex Screw
5/16"- 18 x 7/8"
Nut 5/16" - 18
Lockwasher 5/16"
Figure 2
Bracket
(Not Supplied)
5/16"-18x7/8" Screw
5/16" Lock Washer
5/16"-18 Nut
— FINISHED CEILING —
Lag Screws
5/16"x1-7/8"
CONTROL
CENTER
Preferred Range of Bracket Placement
Hidden Support
(Not Supplied)
5/16"-18x7/8" Screw
5/16" Lock Washer
5/16"-18 Nut
16
Page 17
Installation Step 7
To
Door
Control
To
Sensors
Terminal
Screws
Control
Center

Install the Door Control and Connect all Wiring

Install Door Control
Locate the door control within sight of the door at a minimum height of 5 feet where small children cannot reach, and away from all moving parts of the door and door hardware.
1. Strip 1/4" of insulation from one end of the bell wire
and connect it to the two screw terminals on the back of the door control by color: white to 2 and white/red to 1 (see Figure 1).
2. Fasten the Lighted Door Control Button securely with
6ABx1-1/2" screws. The Multi-Function Door Control uses 6ABx1" screws. If installing into drywall, drill 5/32" holes and use the anchors provided.
3. Run the bell wire up the wall and across the ceiling to
the opener. Use insulated staples to secure the wire in several places. Be careful not to pierce the wire with a staple, creating a short. If your access door is near the
garage door, you may run this wire with the Safety Reversing Sensor wires along the top of the rail. See page 14.
4. Remove the Control Center door on the right panel of
the opener to access the terminal screws.
Connect Door Control and Sensor Wiring
5. Thread all wires through the opening at the base of the
drive shaft cover (see Figure 2).
6. Insert the remaining wire through the hole in the power
unit and strip 1/4" of insulation from each set of wires.
7. Connect the door control wire to the opener terminal
screws: white to 2 and white/red to 1. (See Figure 3.)
8. Separate the sensor white and white/black wires
sufficiently to connect to the opener terminal screws: white to 2 and white/black to 3.
9. Attach the User Safety Instruction label to the wall
near the door control, and the Maintenance Instruction label in a prominent location on the inside of the garage door.
Page 28 explains how to operate the opener using the door controls and the Lock & Light features available on the Multi-Function Door Control Panel.
Outside Keylock Connections (see Accessories)
To opener terminal screws: white to 2; white/red to 1
Hardware Shown Actual Size
6AB x 1" Screw
Multi-Function Door Control
WARNING
Children operating or playing with a garage door opener can injure themselves or others.
close and cause serious injury or death.
control (or any additional push buttons) out of the reach of children and away from all moving parts of the door and door hardware,
but where the garage door is visible.
Do not allow children to operate the push button(s) or the remote control transmitter(s).
A moving garage door could injure someone under it.
Activate the opener only when the door is properly adjusted, you can see it clearly, and there are no obstructions to door travel.
Do NOT connect the power and operate the opener at this time. The trolley will travel to the full open
position but will not return to the close position until the sensor beam is connected and properly aligned. See Step 9 on page 18.
2-Conductor
Bell Wire
WHT
2
RED
Lighted
1
Figure 1
Door
Control
Terminal
Screws
Figure 2 WIRING TO CONTROL CENTER
Door Control Connections
(dotted line)
The garage door could
Install the door
Multi-Function
Door Control Panel
Terminal Screws
RED
WHITE
1
2
Insert wires
through
opening in
Drive Shaft Cover
Push wiring
through hole in chassis
(above Control Center) and connect to opener
terminal screws
Sensor
Connections
6ABx1-1/2" Screw
Lighted Door Control Button
Insulated
Staples
Dry Wall
Anchors
Figure 3
17
1
OPENER TERMINAL SCREWS
2
(In Control Center)
3
Page 18
Installation Step 8

Electrical Requirements

To reduce the risk of electric shock, your garage door opener has a grounding type plug with a third grounding pin. This plug will only fit into a grounding type outlet.
If the plug doesn't fit into the outlet you have, contact a qualified electrician to install the proper outlet.
To avoid installation difficulties,
do not run the opener until Step 9 below.
WARNING
To prevent electrocution or fire,
must be in compliance with local electrical and building codes.
Do NOT use an extension cord, 2-wire adapter, or change the plug in any way to make it fit your outlet.
installation and wiring
If permanent wiring is required by your local code,
refer to the following procedure:
WARNING
To prevent electrocution,
garage door opener use for the permanent connection.
To make a permanent connection through the 7/8" diam. hole in the top of the opener (according to local code):
• Remove the opener cover screws and set the cover aside.
• Remove the attached 3-prong cord.
• Connect the black (line) wire to the screw on the brass terminal; the white (neutral) wire to the screw on the silver terminal; and the ground wire to the green ground screw. The opener must be grounded.
• Reinstall the cover.
remove power from the
and
from the circuit you plan to
Right
Permanent Wiring
Connection
Ground Tab
Green
Ground Screw
Ground Wire
Wrong
White Wire
Black
Wire
BlackWire
Installation Step 9

Complete Safety Reversing Sensor Installation

Plug in the opener. If your door control has a Lock feature, be sure it is off . Green indicator lights in both the sending and receiving eyes will glow steadily if wiring connections and alignment are correct. If the indicator light is off in the receiving eye (and the invisible light beam path is not obstructed), alignment is required.
• Loosen the receiving eye wing nut to allow slight rotation of unit. Adjust sensor vertically and/or horizontally until the green indicator light glows with a
steady light.
• When indicator lights are glowing steadily in both units, tighten the wing nut in the receiving eye unit.
Trouble Shooting
1. If the sending eye indicator light does not glow steadily after installation, check for:
• Electric power to the opener.
• A short in the white or white/black wires. These can occur under staples or at screw terminal connections.
• Incorrect wiring between sensors and opener.
• An open wire (wire break).
2. If the sending eye indicator light glows steadily but
the receiving eye indicator light doesn't:
• Check alignment.
• Check for an open wire to the receiving eye.
18
Page 19
Installation Step 10

Install the Lights and Lens

• Install a 100 watt maximum light bulb in each socket. The lights will turn ON and remain lit for approximately 4-1/2 minutes when power is connected. Then the lights will turn OFF.
• Insert bottom lens tabs into slots on chassis and tilt towards chassis to engage top tabs, then drop down gently into place. (See illustration.)
• To remove, lift lens up and gently tilt slightly outward and down, then pull out to clear bulbs. Use care to
avoid snapping off bottom lens tabs.
• If the bulbs burn out prematurely, replace with standard neck Garage Door Opener bulbs. (Fluorescent bulbs are
not recommended because of possible interference with receiver/transmitter signals.)
Light Socket
CONTROL
CENTER
Bottom Lens Slot
Bottom Lens Tab
CONTROL
CENTER
100 Watt Max.
Light Bulb
Top Lens Slot
Top Lens Tab
Lens
Installation Step 11

Attach the Manual Release Rope and Handle

Trolley
Trolley
Release Arm
Overhand
NOTICE
Knot
Rope
Release Handle
Manual
Overhand
Knot
Chassis
Insert Bottom Lens Tabs First
WARNING
Do not use the red handle to pull the door open or closed.
could fall.
trolley and, if possible, only when the door is closed. Garage doors are heavy. If the door is open when the
handle is pulled, the door could close inadvertently if it is not properly balanced. Serious injury may result to persons under the door. Make sure the doorway is clear of persons and obstructions before pulling handle when door is open.
Thread one end of the rope through the hole in the top
of the red handle so “NOTICE” reads right side up as shown. Secure with an overhand knot.
The knot should be at least 1" from the end of the rope to prevent slipping.
• Thread the other end of the rope through the hole in the release arm of the outer trolley.
• Adjust rope length so the handle is 6 feet above the floor. Secure with an overhand knot .
If it is necessary to cut the rope, heat seal the cut end with a match or lighter to prevent unraveling.
The rope knot could become untied and you
Use the manual release only to disengage the
19
Page 20
Installation Step 12
A horizontal brace should be long enough to be secured to 2 vertical supports. A vertical brace should cover the height of the top panel.
The illustration shows one piece of angle iron as the horizontal brace. For the vertical brace, 2 pieces of angle iron are used to create a U-shaped support. The best solution is to check with your garage door manufacturer for an opener installation door reinforcement kit.

SECTIONAL Door Installation Procedure

Figure 1
Figure 2
Hardware Shown Actual Size

Fasten Door Bracket

Follow instructions which apply to your door type as illustrated below or on page 21.
To prevent dama ge to steel, alumin um, fiber glass or glass panel doors, always reinforce the inside of the door both vertically and horizontally with an angle iron.
• Center the door bracket on the previously marked vertical guideline used for the header bracket installation.
stamped inside the bracket.
• Position the bracket on the face of the door within the following limits:
A) The top edge of the bracket 2-4" below the top edge
of the door.
B) The top edge of the bracket directly below any
structural support across the top of the door.
• Mark and drill 5/16" left and right fastening holes. Secure the bracket as shown in Figure 1 if there is vertical reinforcement.
If your installation doesn't require vertical reinforcement but does need top and bottom fastening holes for the door bracket, fasten as shown in Figure 2.
Note the correct UP placement, as
20
Page 21

All ONE-PIECE Door Installation Procedure

• Center the bracket on the top of the door, in line with
the header bracket as shown. Mark holes.
• Drill 5/16" pilot holes and fasten the door bracket with
hardware supplied.
If the door has no exposed framing, drill 3/16" pilot holes and fasten the bracket with 5/16"x1-1/2" lag screws (not supplied) to the top of the door.
The door bracket may be installed on the top edge of the door if required for your installation. (Refer to the dotted line optional placement drawing.) Drill 3/16" pilot holes and substitute 5/16"x1-1/2" lag screws (not supplied) to fasten the bracket to the door.
21
Please read and comply with the warnings and reinforcement instructions on page 20. They apply to one-piece doors also.
Hardware Shown Actual Size
Page 22
Installation Step 13
Make sure garage door is fully closed. Pull the emergency release handle to disconnect the outer trolley from the inner trolley. Slide the outer trolley back (away from the door) about 2" as shown in Figures 1, 2 and 3.
Figure 2:
Figure 1:
Fasten straight door arm section to outer trolley with
the 5/16"x1" clevis pin. Secure the connection with a ring fastener.
• Fasten curved section to the door bracket in the same
way, using the 5/16"x1-1/4" clevis pin.
Figure 1
Figure 2
Figure 3

SECTIONAL Doors Only

Hardware Shown Actual Size
Hole Alignment Alternative

Connect Door Arm to Trolley

Follow instructions which apply to your door type as illustrated below and on page 23.
Bring arm sections together. Find two pairs of holes that line up and join sections. Select holes as far apart as possible to increase door arm rigidity.
Figure 3:
If holes in curved arm are
disconnect straight arm. Cut about 6" from the solid end. Reconnect to trolley with cut end down as shown.
• Bring arm sections together.
• Find two pairs of holes that line up and join with
screws, lock washers and nuts.
above holes in straight arm,
Proceed to Adjustment Step 1, page 24. Trolley will re-engage automatically when the opener is operated.
22
Page 23

All ONE-PIECE Doors

Assemble the Door Arm:
Fasten the straight and curved door arm sections
together to the longest possible length (with a 2 or 3 hole overlap).
• With the door closed, connect the straight door arm section to the door bracket with the 5/16"x1-1/4" clevis pin.
• Secure with a ring fastener.
On one-piece doors, before connecting the door arm to the trolley the travel limits must be adjusted. Limit adjustment screws are located on the right side panel as shown on page 24. Follow adjustment procedures below.
Adjustment Procedures for One-Piece Doors
Open Door Adjustment:
Decrease UP Travel Limit
• Turn the UP limit adjustment screw counter-clockwise 5 1/2 turns.
• Press the Door Control push bar. The trolley will travel to the fully open position.
• Manually raise the door to the open position (parallel to the floor), and lift the door arm to the trolley. The arm should touch the trolley just in back of the door arm connector hole. Refer to the fully open trolley/door arm positions in the illustration. If the arm does not extend far enough, adjust the limit further. One full turn equals 2" of trolley travel.
Closed Door Adjustment:
Decrease DOWN Travel Limit
• Turn the DOWN limit adjustment screw clockwise 5 complete turns.
• Press the Door Control push bar. The trolley will travel to the fully closed position.
• Manually close the door and lift the door arm to the trolley. The arm should touch the trolley just ahead of the door arm connector hole. Refer to the fully closed trolley/door arm positions in the illustration. If the arm is behind the connector hole, adjust the limit further. One full turn equals 2" of trolley travel.
Connect the Door Arm to the Trolley:
Close the door and join the curved arm to the connector hole in the trolley with the remaining clevis pin. It may be necessary to lift the door slightly to make the connection.
• Secure with a ring fastener.
• Run the opener through a complete travel cycle. If the door has a slight "backward" slant in full open position as shown in the illustration, decrease the UP limit until the door is parallel to the floor.
23
Page 24
Adjustment Section: Pages 24 – 26
Adjustment Step 1

Adjust the UP and DOWN Limits

Do not make any limit adjustments until the safety reversing sensors are completely installed.
Limit adjustment settings regulate the points at which the door will stop when moving up or down.
The door will stop in the up direction if anything interferes with door travel. The door will reverse in the down direction if anything interferes with the door travel (including binding or unbalanced doors).
To operate the opener, press the Door Control push bar or button. Run the opener through a complete travel cycle.
• Does the door open and close completely?
• Does the door stay closed and not reverse unintentionally when fully closed?
If your door passes both of these tests, no limit adjustments are necessary unless the reversing test fails (see page 26).
Adjustment procedures are outlined below. Run the opener through a complete travel cycle after each adjustment.
Repeated operation of the opener during adjustment procedures may cause the motor to overheat and shut off. Simply wait 15 minutes and try again.
Read the procedures carefully before proceeding to Adjustment Step 2. Use a screwdriver to make limit adjustments.
WARNING
Improper adjustment of the travel limits will interfere with the proper operation of the safety reverse system.
door might not reverse properly when required and could seriously injure or kill someone under it.
Test the safety reverse system monthly, and following all adjustments to the travel limits. See page 26.
+
321
8
8
1
1
7
7
3
3
5
5
+
Kg
Kg
Right Side Panel
LIMIT ADJUSTMENT
LABEL
+
+
Adjust UP Travel
Adjust DOWN Travel
The
Travel Limit
Adjustment
Screws
How and When to Adjust the Limits
If the door does not open completely but opens at least five feet:
Increase up travel. Turn the UP limit adjustment screw clockwise. One turn equals 2" of travel.
If door does not open at least 5 feet: Adjust the UP (open) force as explained in Adjustment Step 2.
If the door does not close completely:
Increase down travel. Turn the DOWN limit adjustment screw counterclockwise. One turn equals 2" of travel.
If door still won't close completely, try lengthening the door arm. (Page 22.)
If you have adjusted the door arm to the maximum length and the door still will not close completely, lower the header bracket. See Installation Step 1, pages 8/9.
If the opener reverses in fully closed position:
Decrease down travel. Turn the DOWN limit adjustment screw clockwise. One turn equals 2" of travel.
If the door reverses when closing and there is no visible interference to travel cycle:
If the opener lights are flashing, the Safety Reversing Sensor is obstructed. Remove the obstruction.
Test the door for binding: Pull the manual release handle. Manually open and close the door. If the door is binding, call for garage door service. If the door is not binding or unbalanced, adjust the DOWN (close) force. See Adjustment Step 2.
24
Page 25
Adjustment Step 2

Adjust the Force

Force adjustment controls are located on the right panel of the opener. Force adjustment settings regulate the amount of power required to open and close the door.
The door will stop in the up direction if anything interferes with its travel. The door will reverse in the down direction if anything interferes with its travel (including binding or unbalanced doors).
If the forces are set too light, door travel may be interrupted by nuisance reversals in the down direction and stops in the up direction. Weather conditions can affect the door movement, so occasional adjustment may be needed.
The maximum force adjustment range is about 3/4 of a complete turn. Do not force controls beyond that point. Turn force adjustment controls with a screwdriver.
8
7
5
Kg
8
1
7
3
1
3
5
Kg
WARNING
Too much force on the door will interfere with the proper operation of the safety reverse system.
not reverse properly when required and could seriously injure or kill someone under it.
Do not increase the force beyond the minimum amount required to close the door. Do not use the force adjustments to compensate for a binding or sticking garage door. Test the safety reverse system monthly, and following all adjustments to force levels. See page 26.
+
321
8
8
1
1
7
7
3
3
5
5
Kg
Kg
+
The door might
Force Adjustment Label
How and When to Adjust the Forces
Test the DOWN (close) force
Grasp the door bottom when the door is about halfway through DOWN (close) travel. The door should reverse.
Reversal halfway through down travel does not guarantee reversal on a one-inch obstruction. See page 26. If the door is hard to hold or doesn't reverse,
decrease the DOWN (close) force by turning the control counterclockwise.
Make small adjustments until the door reverses normally. After each adjustment, run the opener through a complete cycle.
Test the UP (open) force
Grasp the door bottom when the door is about halfway through UP (open) travel. The door should stop. If the door is hard to hold or doesn't stop, decrease UP (open) force by turning the control counterclockwise.
Make small adjustments until the door stops easily. After each adjustment, run the opener through a complete travel cycle.
Right Side
Panel
Force Adjustment
Controls
If the door doesn't open at least 5 feet:
Increase UP (Open) force by turning the control clockwise. Make small adjustments until door opens completely. Readjust the UP limit if necessary. After each adjustment, run the opener through a complete travel cycle.
If the door reverses during the down (close) cycle and the opener lights aren't flashing:
Increase DOWN (close) force by turning the control clockwise. Make small adjustments until the door completes a close cycle. After each adjustment, run the opener through a complete travel cycle. Do not increase
the force beyond the minimum amount required to close the door.
25
Page 26
Adjustment Step 3
Test The Protector System
• Press the remote control push button to open the door.
• Place the opener carton in the path of the door.
• Press the remote control push button to close the door.
The door will not move more than an inch, and the opener light will flash for 5 seconds.
Professional service is required if the opener closes the door when the safety reversing sensor is obstructed.
The garage door opener will not close from a remote if the indicator light in either sensor is off (alerting you to the fact that the sensor is misaligned or obstructed).
The garage door can be closed by pressing and holding the Door Control push bar or button until down travel is completed.
®
WARNING
Without a properly working safety reversing sensor, persons (particularly children) could be seriously injured or killed if trapped by a closing garage door.
test once a month.
Repeat this
Adjustment Step 4

Test the Safety Reverse System

Test
• Place a one-inch board (or a 2x4 laid flat) on the floor,
centered under the garage door.
• Operate the door in the down direction. The door must
reverse on striking the obstruction.
Adjustment
If the door stops on the obstruction, it is not traveling far enough in the down direction.
• Increase the DOWN limit by turning the DOWN limit
adjustment screw counterclockwise 1/4 turn.
• Repeat the test.
On a sectional door, make sure limit adjustments do not force the door arm beyond a straight up and down position. See the illustration on page 22.
• When the door reverses on the one-inch board, remove
the obstruction and run the opener through 3 or 4 complete travel cycles to test adjustment.
If the door will not reverse after repeated adjustment attempts, call for professional garage door service.
Important Safety Check
Repeat Adjustment Steps 1-4 after:
• Each adjustment of door arm length, force controls or
limit controls.
• Any repair to or adjustment of the garage door
(including springs and hardware).
• Any repair to or buckling of the garage floor.
• Any repair to or adjustment of the opener.
Safety Reversing Sensor
Safety Reversing Sensor
WARNING
Failure to test and adjust the safety reverse system may result in serious injury or death to persons trapped by a closing garage door.
adjust as needed.
Repeat this test once a month and
One-Inch board (or a 2x4 laid flat)
1 Inch Obstruction
26
Page 27

IMPORTANT SAFETY INSTRUCTIONS

WARNING
WARNING
To reduce the risk of severe injury or death to persons:
1. READ AND FOLLOW ALL INSTRUCTIONS.
2. Do not permit children either to operate or to play with the opener. Keep remote control in a location inaccessible to children.
3. Operate opener only when the door is in full view and free from any obstruction. Keep the door in sight until it is completely closed. NO ONE SHOULD CROSS THE PATH OF THE MOVING DOOR.
4. Check safety reversal system monthly. See page 26. The garage door MUST reverse on contact with a one inch object (or a 2x4 board laid flat) placed on the floor. If an adjustment is made to one of the controls (either force or limits of travel), the other control may need to be adjusted also, and the safety reversal system must be checked. Failure to properly adjust the opener may result in severe injury or death.
5. If possible, use the manual release only when the door is in a closed position. Caution should be taken whenever the disconnect cord is actuated with the door open. Weak or broken springs may cause the door to
fall rapidly, causing injury or death to persons.
6. KEEP GARAGE DOORS PROPERLY BALANCED. See page 3. An improperly balanced door may not reverse when required, and could result in severe injury or death. Repairs to cables, spring assemblies and
other hardware must be made by a professional garage door person.
7. Disconnect the electric power to the garage door opener before making any r epairs or removing the covers.
SAVE THESE INSTRUCTIONS

Care of Your Opener

Force and Limit Adjustment Controls
8
7
5
Kg
FORCE CONTROLS
8
1
7
3
1
3
5
Kg
LIMIT CONTROLS
Weather conditions may cause some minor changes in door operation requiring some re-adjustments, particularly during the first year of operation.
Pages 24 and 25 refer to the limit and force adjustments. Only a screwdriver is required. Follow the instructions carefully.
Repeat the safety reverse test (page 26) after any adjustment of limits or force.

Maintenance Schedule

Once a Month
Manually operate door. If it is unbalanced or binding, call for professional garage door service.
Check to be sure door opens & closes fully. Adjust limits and/or force if necessary. (See pages 24 & 25.)
+
+
The Remote Control Transmitter
The opener must learn the code of any new remote control. Page 29 explains how to program your receiver and how to erase all codes if required. Self service of your receiver and remote controls is not recommended. If service is needed, call the toll-free number listed on the back page.
The Transmitter Battery
The green test light will glow and the opener will operate when the remote control is activated, as long as there is adequate battery power.
If the power indicator light is dim or off, replace the battery. Also check the test light if transmission range decreases.
The 12 volt battery should produce power for at least a year.
Dispose of your old battery properly.
Repeat the safety reverse test. Make any necessary
adjustments (See page 26).
Once a Year
Oil door rollers, bearings and hinges. The opener does not require additional lubrication. Do not grease the door tracks.
27
Page 28

Operation of Your Opener

Activate the opener with any of the following:
• The Remote Control Transmitter. Hold push button
down until the door starts to move.
• The Door Control. Hold push bar or button down
until the door starts to move.
• The Outside Keylock or Keyless Entry. (See
Accessories)
When the opener is activated with the safety reversing sensor installed and correctly aligned:
1. If open, the door will close. If closed, the door will open.
2. If closing, the door will reverse.
3. If opening, the door will stop (allowing space for entry and exit of pets and for fresh air).
4. If the door has been stopped in a partially open position, it will close.
5. If obstructed while closing, the door will reverse.
6. If obstructed while opening, the door will stop.
7. The garage door will reverse in the closing cycle when the invisible beam is broken. If fully open, the door will not close when the beam is broken. The sensor has no effect in the opening cycle.
If the sensor is not installed, or is not aligned correctly, the door won't close from any remote transmitter. You can close the door with the Door Control, the Outside Keylock, or Keyless Entry, however, if you activate them until down travel is complete. If you release them too soon, the door will reverse.
The opener lights will blink for 5 seconds when the safety reversing sensor causes the door to reverse.
Opener Lights will turn on under the following conditions: When the opener is initially plugged in; when the power is interrupted; when the opener is activated. They will turn off automatically after 4-1/2 minutes or provide constant light when the Light feature is activated. Bulb size is 100 watts maximum.
WARNING
Weak or broken springs could allow an open door to fall (either rapidly or unexpectedly), resulting in serious injury, death or property damage .
manual release rope and handle fully closed.
To open the door
Trolley
Trolley
ReleaseArm
(in Manual
Disconnect
Position)
NOTICE
manually:
The door should be fully closed if possible. Pull down on the manual release handle (so that the trolley release arm snaps into a vertical position) and lift the door manually. The lockout
Lockout position
(Manual disconnect)
feature prevents the trolley from reconnecting auto­matically, and the door can be raised and lowered manually as often as necessary.
To reengage the trolley:
Pull the manual release handle toward the opener at a 45° degree angle so that the trolley release arm is horizontal. The trolley will reconnect on the next UP or DOWN operation, either manually or by pressing the Door Control push bar.
If possible, use the
only
when the door is
Manual
Release
Handle
(Pull at 45° angle)
Trolley
Release Arm
NOTICE
To reconnect
Trolley

Operation of the Door Controls

(both are not included with all models)
Lighted Door Control Button; Lighted Push Bar – Door Control Panel: Press to
open or close the door. Press again to reverse the door during the closing cycle
or to stop the door while it's opening. Light Feature – Door Control Panel: Press the Light
button. If the opener light is off, it will turn on. If the opener light is on, (even in the 4-1/2 minute
automatic cycle) it will turn off. But if you use the Light button to turn the light(s) on and
then activate the opener, the light(s) will turn off after 4-1/2 minutes.
The Light button will not control the opener lights when the door is in motion.
Lock Feature – Door Control Panel: The Lock feature is designed to prevent operation of the door from remote controls. However, the door will open and close from the Door Control push bar, the Outside Keylock and the Keyless Entry Accessories.
To Activate: Press and hold the Lock button for 2 seconds. The push bar light will flash as long as the Lock feature is on.
To turn off: Press and hold the Lock button again for 2 seconds. The push bar light will stop flashing. The Lock feature will also turn off whenever the "Smart" button on the opener panel is activated.
28
Page 29
Page 30

Having a Problem?

Situation Probable Cause & Solution
The opener doesn't operate from either the door control or the remote control:
Opener operates from the remote control, but not from the door control:
The door operates from the door control, but not from the remote control:
1. Does the opener have electric power? Plug a lamp into the outlet. If it doesn't light, check the fuse box or the circuit breaker . (Some outlets are controlled by a wall switch.)
2. Have you disabled all door locks? Review installation instruction warnings on Page 7.
3. Is there a build-up of ice or snow under the door? The door may be frozen to the ground. Remove any restriction.
4. The garage door spring may be broken. Have it replaced.
5. Repeated operation may have tripped the overload protector in the motor. Wait 15 minutes. Try again.
1. Is the door control push bar lit? If not, Remove the bell wire from the opener terminal screws. Short the red and white terminals by touching both terminals at the same time with a piece of wire. If the opener runs, check for a faulty wire connection at the door control, a short under the staples, or a broken wire.
2. Are the wiring connections correct? Review Installation Step 7, page 17.
1. If your model has the Lock feature, turn it off.
2. Is the wall push button flashing? Your opener needs to re-learn a remote control code. Refer to instructions on the opener panel.
3. Does the battery test light glow when the remote control push button is pressed? If not, replace the battery.
4. Program the receiver to match the remote control code.
5. Repeat the receiver programming procedure with all remote controls.
The remote control has short range:
Opener noise is disturbing in living quarters of home:
The garage door opens and closes by itself:
The door doesn't open completely:
1. Check the battery test light. If the light is dim, replace the battery.
2. Change the location of the remote control in your car.
3. Check to be sure the antenna on the right side panel of opener extends fully.
4. Some installations may have shorter range due to a metal door, foil backed insulation, or
metal garage siding.
If operational noise is a problem because of proximity of the opener to the living quarters, the Vibration Isolator Kit 41A3263 can be installed. This kit was designed to minimize vibration to the house and is easy to install.
1. Be sure that all remote control push buttons and battery indicator lights are off.
2. Remove the bell wire from the door control terminals and operate from the remote control only. If this solves the problem, the door control is faulty (replace), or there is an intermittent short on the wire between the door control and the opener.
1. If the door has been working properly but now doesn't open all the way, increase the up force. See page 25.
2. Is something obstructing the door? Remove the obstruction or repair the door.
3. If door opens at least 5 feet, the travel limits may need to be increased. One turn equals 2 inches of travel. See page 24.
Repeat the safety reverse test after the adjustment is complete.
The door stops but doesn't close completely:
Review the travel limits adjustment procedures on page 24.
Repeat the safety reverse test after any adjustment of door arm length, close force or down limit.
30
Page 31
Having a Problem?
Situation Probable Cause & Solution
(continued)
The door opens but won't close:
The door reverses for no apparent reason and opener lights don't blink:
The door reverses for no apparent reason and opener lights blink for 5 seconds after reversing:
The opener lights… don't turn on:
1. If the opener lights blink, check the safety reversing sensor. See page 18.
2. If the opener lights do not blink and it is a new installation, check the down force. See Adjustment Step 2, page 25. For an existing installation, see below.
Repeat the safety reverse test after the adjustment is complete.
1. Is something obstructing the door? Pull the manual release handle. Operate the door manually. If it is unbalanced or binding, call for professional garage door service.
2. Clear any ice or snow from the garage floor area where the door closes.
3. Review the force adjustment procedures on page 25.
4. If door reverses in the fully closed position, decrease the travel limits (page 24).
Repeat the safety reverse test after adjustments to force or travel limits. The need for occasional adjustment of the force and limit settings is normal. Weather conditions in particular can affect door travel.
Check the safety reversing sensor. Remove any obstruction or align the receiving eye. See page 18.
Replace the light bulb(s) (100 watts maximum). Use a standard neck garage door opener bulb if regular bulb burns out.
don't turn off:
Is the Light feature on? Turn it off.
The opener strains or maximum force is needed to operate door:
The opener motor hums briefly, then won't work:
The opener won't operate due to power failure:
The door may be out of balance or the springs are broken. Close the door and use the manual release handle to disconnect the trolley. Open and close the door manually. A properly balanced door will stay in any point of travel while being supported entirely by its springs. If it does not, disconnect the opener and call for professional garage door service. Do not
increase the force to operate the opener.
1. The garage door springs are broken. See above.
2. If the problem occurs on the first operation of the opener, door may be locked. Disable the
door lock.
Repeat the safety reverse test after the adjustment is complete.
1. Use the manual release handle to disconnect the trolley. The door can be opened and closed manually. When power is restored, press the Door Control push bar and trolley will automatically reconnect (unless trolley is in lockout position.) See page 28.
2. The Outside Quick Release accessory (for use on garages with no service door) disconnects the trolley from outside the garage in case of power failure.
31
Page 32
Page 33
Page 34

Accessories Available For Your Opener

Model 1702LM
Model 60LM
Model 88SD
Model 66LM
Model 58LM
LOCK
LIGHT
Outside Quick Release:
Required for a garage with NO access door. Enables homeowner to open garage door manually from outside by disengaging trolley.
Outside Keylock:
Operates the garage door automatically from outside when remote control is not handy.
8 foot Complete Rail:
To allow an 8 foot door to open fully.
Keyless Entry:
Enables homeowner to operate garage door opener from outside by entering code on specially designed keyboard.
Multi-Function Door Control Panel:
Provides a Lock Feature which prevents operation of garage door opener from portable remotes and a Light Feature for constant light.
Model 81LM
Model 82LM
Model 83LM
Model 84LM
Model 61LM
“Smart” Remote Control:
Includes visor clip.
2-Channel “Smart” Remote Control:
Includes visor clip.
3-Channel “Smart” Remote Control:
Includes visor clip.
4-Channel “Smart” Remote Control:
Includes visor clip.
Single-Function Standard Size Remote Control:
Includes visor clip.
Model 742LM
Model 722LM
Plug-In Light Control:
Controls interior lights. Plugs into a wall receptacle.
Wire-In Light Control:
Controls interior or exterior lights. Wires into the electrical box like a dimmer switch.
Model 64LM
Model 99LM
9 0
7 8
5 6
3 4
1 2
Multi-Function Mini Remote Control:
With key ring & Velcro fastening strip.
Remote Security Transmitter:
Enables homeowner to operate garage
ENTER
door opener by entering 2, 3, 4, or 5 digit code from backlit keyboard. Includes visor clip.
34
Page 35

Index

Access Door/Outside Quick Release Accessory.........................................................................................................31, 34
Electrical Safety Warnings......................................................................................................................................7, 18, 27
Garage Door
Testing for balance, binding and sticking.................................................................................................................3, 24, 27
Determining high point of travel:
Sectional door....................................................................................................................................................................8
One-piece door..................................................................................................................................................................9
Disabling existing locks...................................................................................................................................................3, 7
Force controls
Adjustment procedures....................................................................................................................................................25
Problems that might require force adjustments.........................................................................................................30, 31
Safety warnings.........................................................................................................................................................25, 27
Door hardware............................................................................................................................................3, 7, 8, 17, 27, 28
Maintenance .............................................................................................................................................................7, 24-27
Reinforcement requirements....................................................................................................................................5, 20, 21
Removing of all ropes......................................................................................................................................................3, 7
Possible door damage...............................................................................................................................................4, 15, 20
Travel limits
Adjustment procedures..............................................................................................................................................23, 24
Problems that might require limit adjustments .........................................................................................................30, 31
Safety warnings.........................................................................................................................................................24, 27
Manual Release Rope & Handle
Lockout feature .................................................................................................................................................................28
Manual disconnect.......................................................................................................................................................28, 31
Safety warnings.................................................................................................................................................7, 19, 27, 28
Opener Terminals
Door control connections..................................................................................................................................................17
Safety reversing sensor connections .................................................................................................................................17
Outside Keylock accessory connections...........................................................................................................................17
Operational Noise
Vibration noise (isolator kit).............................................................................................................................................30
®
Protector System Receiver & Remote Controls
Programming the receiver.................................................................................................................................................29
Erasing all codes................................................................................................................................................................29
Safety warning...................................................................................................................................................................29
Problems with remote control transmitter operation.........................................................................................................30
Safety Reverse Test Procedure..........................................................................................................................................26
Testing required.................................................................................................................................................7, 26, 30, 31
Safety reverse system problems
Securing header bracket to wall........................................................................................................................................8
Adjusting travel limits.....................................................................................................................................................24
Applying excessive force on the door.............................................................................................................................25
Buckling or uneven floor...................................................................................................................................................5
.........................................................................................................................................................12, 26
Safety Warnings..........................................................................2, 3, 7, 8, 12, 15, 16, 17, 18, 19, 20, 24, 25, 26, 27, 28, 29
User Instruction Label for Garage Wall......................................................................................................................7, 17
35
Page 36
Loading...