ChallengerOptics CO-OPM-MPO12 Operating Manual

Page 1
ChallengerOptics.com
Wavelength Specic Optical Testing and Measurement Equipment
MPO Optical Power Meter
- 12 ber
ChallengerOptics
CO-OPM-MPO12
OPERATING MANUAL
1.0 Introduction . . . . . . . . . . . . . . . . 3
1.1 Special Features . . . . . . . . . . . . . 3
1.2 Specications . . . . . . . . . . . . . . 3
1.3 Package Content . . . . . . . . . . . . . 4
1.4 Charge Method . . . . . . . . . . . . . 4
2.1 Explanation of Operating Keys . . . . . . . . 5
2.2.1 Power ON / OFF . . . . . . . . . . . 6
2.2.2 Power Meter . . . . . . . . . . . . 7
2.2.3 Scan . . . . . . . . . . . . . . . 8
2.2.4 dB/dBm: Relative/Absolute Measurements. 8
2.2.5 Graph . . . . . . . . . . . . . . . 10
2.2.6 Recall . . . . . . . . . . . . . . . 10
2.3.3 Auto Power O . . . . . . . . . . . 14
2.3.4 Time Set . . . . . . . . . . . . . . 14
2.3.5 Data Delete . . . . . . . . . . . . 15
2.3.6 Data Format . . . . . . . . . . . . 16
2.3.7 System Info . . . . . . . . . . . . 16
2.3.8 Scan Type . . . . . . . . . . . . . 17
2.3.9 Scan Display . . . . . . . . . . . . 17
2.3.10 Threshold . . . . . . . . . . . . . 18
CONTENTS
051818
Page 2
ChallengerOptics.com
Wavelength Specic Optical Testing and Measurement Equipment
ChallengerOptics.com
Wavelength Specic Optical Testing and Measurement Equipment
Chapter 1.0 - Introduction / 04Chapter 1.0 - Introduction / 03
1. Introduction
1.1 Special Features
- 12 Fiber
- Quick power measurement on all bers
- Compact size, one button operation
- Color LCD for graph display
- Light weight for easy eld use
- Quick start: No warm-up and 2 second measurement
- Software provided for data management
1.2 Specications
Channels 12 Fiber Wavelength 850, 1310, 1550 nm Measurement Speed 1 sec. (approx.) Measurement Range +10 dBm to -40 dBm Measurement Accuracy ±0.5 @ -20 dBm Display Resolution 0.01 dB Optical Connector MPO Angled, unpinned Display Units dB, dBm Display 2.8” TFT-LCD, 16 bit Color Battery / Power Rechargeable Lithium-Polymer – 7 hr. Operating Temperature -20° ~ +55° C Weight 13 oz* Dimensions h / w / d 7 x 3.25 x 1.5 (inches)* *w/boot
1.3 Package Contents
Description Quantity
Body 1 ea Body Rubber Case 1 ea USB Data cable 1 ea Charger 1 ea User’s Manual - USB stick 1 ea
1.4 Charge Method
The CO-OPM-MPO12 has a rechargeable battery. A USB power adapter and micro USB cable are provided for charging. Typical charge time is six hours.
Charging conditions:
LED Color Action of LED Conditions for battery charge
Red ON Charging
Green ON Fully charged
1.5 Meter Care
Do not subject the CO-OPM-MPO12 to strong impact. The CO-OPM-MPO12 is not water resistant or waterproof Do not disassemble. Always properly clean the ber interfaces before taking a measurement. Always replace the Dust Cap for dust protection.
Page 3
ChallengerOptics.com
Wavelength Specic Optical Testing and Measurement Equipment
ChallengerOptics.com
Wavelength Specic Optical Testing and Measurement Equipment
Chapter 2.1 - Explanation of Operating Keys / 06Chapter 2.1 - Explanation of Operating Keys / 05
2. Getting Started
2.1 Explanation of Operating Keys
Key Function
Backlight Power On/O, Backlight On/O
PM Single Fiber, Fiber number and Power Display
λ Changing inspection wavelength
SCAN
Fibers are scanned and power levels are displayed
dB/dBm Toggle between dB and dBm UOM
▲ Move UP in a menu/page up in result screen
Graph Power levels of all bers are displayed as a graph
Recall Recall saved measurements
▼ Move down in a menu/page down in result screen
SAVE Save measurement to meter memory
ESC Cancel or move back to previous menu
MENU Access System Menu and settings
ENTER Enter
2.2 Key Function
2.2.1 Power ON / OFF
To turn on and o.
Press the button for more than 2 seconds, the logo shown appears. The meter then displays the channel with the highest power level.
Press the button for more than 2 seconds to turn the power o.
Backlight
Backlight
Page 4
ChallengerOptics.com
Wavelength Specic Optical Testing and Measurement Equipment
ChallengerOptics.com
Wavelength Specic Optical Testing and Measurement Equipment
Chapter 2.2 - Key Function / 08Chapter 2.2 - Key Function / 07
2.2.2 Power Meter
PM button has 2 options ‘Auto’ and ‘Manual’. Designated by “A” and “M” in top right of screen. If you select ‘Auto’, the instrument automatically scans the optical input and displays the ber with the highest level of power.
If “Manual” is selected, the user selects the ber to be measured.
Press the button, mode will change between “Auto” and “Manual” and vice versa.
You can select the dierent bers using
Press the button to change the inspection wavelength.
5 jkl
8 tuv
PM
1 .qz
λ
2 abc
2.2.3 Scan
Press the button, scan­ning starts for all 12 Fibers.
Press the button to change the inspection wavelength..
2.2.4 dB / dBm: Relative/Absolute Measurements
This button toggles between dB (relative) & dBm (absolute) power measurements
To measure the relative loss of an MPO circuit, connect the CO-OPM-MPO12 to a known light source with a short (test) jumper.
(continued)
SCAN
3 def
dB/dBm
4 ghi
λ
2 abc
Page 5
ChallengerOptics.com
Wavelength Specic Optical Testing and Measurement Equipment
ChallengerOptics.com
Wavelength Specic Optical Testing and Measurement Equipment
Chapter 2.2 - Key Function / 10Chapter 2.2 - Key Function / 09
2.2.4 dB / dBm:
With dBm selected as the UOM, press scan.
Press the dB/dBm button to choose dB as UOM (the meter will pause a few seconds while it stores the power measurements).
A scan will appear with dB values close to 0.00 dB. A graph is also available.
Remove test jumper and replace with jumper to be measured
Press scan: The relative loss of the jumper will be displayed on both the table and graph.
SCAN
3 def
SCAN
3 def
dB/dBm
4 ghi
2.2.6 Recall
The button will recall saved measurements.
Press to select the data you want to display.
Recall
7 prs
ENTER
2.2.5 Graph
The button is used after scanning to show power levels in graphical format.
Press the button again it returns to table format.
Graph
6 mno
Graph
6 mno
Page 6
ChallengerOptics.com
Wavelength Specic Optical Testing and Measurement Equipment
ChallengerOptics.com
Wavelength Specic Optical Testing and Measurement Equipment
Chapter 2.3 - Menu / 12Chapter 2.2 - Key Function / 11
2.2.7 Save
The button allows the user to save a measurement. The following message shows, and the measurement is saved using the current date and time as the lename.
Then, press the button to save.
To abort saving, press .
ESC
ENTER
SAVE
9 wxy
2.3 MENU
The button, allows you to congure the operating environment of the CO-OPM-MPO12
The menu consists of: Polarity Oset Auto Power O Time Set Data Delete Data Format System Info Scan Type Scan Display Threshold
MENU
0 BS
Page 7
ChallengerOptics.com
Wavelength Specic Optical Testing and Measurement Equipment
ChallengerOptics.com
Wavelength Specic Optical Testing and Measurement Equipment
Chapter 2.3 - Menu / 14Chapter 2.3 - Menu / 13
2.3.2 Oset
Use this option to input the oset value when measuring o a test port
Input the value of the test port.
You can set the oset anywhere between ±25.99dBm.
‘+’ and ‘-’ sign can be changed with the and buttons after oset value is entered.
5 jkl
8 tuv
2.3.1 Polarity
Use this option to change the polarity of the measurement. Straight (Type A) Rollover (Type B) Flipped (Type C)
2.3.3 Auto Power O
The meter will automatically power down if the user does not input any key in the determined time.
You can set the time between 5 to 600 Min. by pressing the number key and button.
ENTER
2.3.4 Time Set
Press the button after selecting ‘Time Set’, to set the date and current time.
Enter date in YY/MM/DD format
Enter time in HH/MM/SS format
You can save the time by pressing button.
ENTER
ENTER
Page 8
ChallengerOptics.com
Wavelength Specic Optical Testing and Measurement Equipment
ChallengerOptics.com
Wavelength Specic Optical Testing and Measurement Equipment
Chapter 2.3 - Menu / 16Chapter 2.3 - Menu / 15
2.3.5 Data Delete
Press the button after selecting ‘Delete Data’, you can delete saved measurements.
Use and to select data set to be deleted.
Press the key after choosing the data you want to delete, the message appears on the screen to conrm to delete or not.
Press the button, to delete measurement from the memory.
ENTER
ENTER
ENTER
5 jkl
8 tuv
2.3.6 Data Format
You can delete all saved les by formatting the memory.
Press the key after ‘Data Format’, message appears on the screen to conrm.
Press the button, all les are deleted from the memory.
CAUTION: This option deletes ALL DATA saved on the meter.
ENTER
ENTER
2.3.7 System Info
General information about the equipment.
PN - Product Name SN - Serial Number HW - Hardware version FW - Firmware version
Page 9
ChallengerOptics.com
Wavelength Specic Optical Testing and Measurement Equipment
ChallengerOptics.com
Wavelength Specic Optical Testing and Measurement Equipment
Chapter 2.3 - Menu / 18Chapter 2.3 - Menu / 17
2.3.9 Scan Display
‘Scan Display’ consists of ‘All’ and ‘Measured’.
This can be selected using , .
‘All’ will display power level on all 12 bers.
If you choose ‘Measured’, only active bers will be displayed.
5 jkl
8 tuv
2.3.8 Scan type
This option allows the user to choose the scan type: Press & Scan (Single) or Real Time using the and keys,
user can toggle between a single scan or continuous (real time) scan when you press the button.
5 jkl
8 tuv
SCAN
3 def
2.3.10 Threshold
This will change the baseline of the meter.
‘-30.00 dBm’ is the default setting.
Any power Level below the threshold will be displayed in purple.
Press the button after selecting ‘Threshold’, you can set the baseline.
ENTER
Loading...