ChallengerOptics CO-OLS-6100 Operating Manual

Tunable DWDM Laser Source
OPERATING MANUAL
ChallengerOptics
CO-OLS-6100
ChallengerOptics.com
Wavelength Specic Optical Testing and Measurement Equipment
1.0 Safety .............................3
2.0 Power ON..........................4
3.0 Laser Source Operation ..........5 - 6
4.0 Sweep Mode Operation.......... 7 - 8
5.0 VFL Operation .....................9
CONTENTS
ChallengerOptics.com
Wavelength Specic Optical Testing and Measurement Equipment
Chapter 1.0 - Safety / 03
ChallengerOptics.com
Wavelength Specic Optical Testing and Measurement Equipment
LASER SAFETY
The Tunable Laser Source has been congured to provide laser radiation in the C Band of operation. (1530-1565nm) This unit has been designed to comply with 21 CFR (Code of Federal Regulations) 1040.10 and 1040.11, for Class 1M emission limits. Although Class 1 levels are not considered to be hazardous, we suggest limiting exposure by never looking directly into the optical aperture. Also, do not under any circumstance view or inspect the laser output bers, connectors or the ber under test through collimating or focusing optics unless the unit is turned o, batteries are removed and the power adapter is disconnected.
Chapter 2.0 - Power ON / 04
POWER ON
Press the blue power button.
The home screen will be displayed.
Touch the TLS icon to open the Tunable Laser Source function.
ChallengerOptics.com
Wavelength Specic Optical Testing and Measurement Equipment
ChallengerOptics.com
Wavelength Specic Optical Testing and Measurement Equipment
Chapter 3.0 - Laser Source Operation / 05
LASER SOURCE OPERATION
The Laser Output units are displayed in the center of the screen. (shown here in nm) Touch this value to cycle through units of, Wavelength (nm), Frequency (THz) and Channel (Ch).
Initialize the Step Size by touching the indicator to cycle through step sizes. Sizes of 0.40/0.80/1.60nm for wavelength, 50/100/200 GHz for frequency or 0.5/1.0/2.0 Ch for channel is displayed.
Touch the power value and a numeric keypad will be displayed. Enter the desired power value within the ranges set at the top of the and touch OK.
Continued
Chapter 3.0 - Laser Source Operation / 06
Touch the dwell time and a numeric keypad will be displayed. Enter any value between 0 and 60 seconds. Choose a value of zero for Constant source operation.
Touch and hold the blue wavelength/frequency/channel selector on the scale. Drag the selector to the desired output value. Alternately the up and down a channel select buttons may be used.
Touch the laser icon or the laser start/pause to energize the laser. Touch a second time to turn o the laser.
or
or
ChallengerOptics.com
Wavelength Specic Optical Testing and Measurement Equipment
ChallengerOptics.com
Wavelength Specic Optical Testing and Measurement Equipment
Chapter 4.0 - Sweep Mode Operation / 07 Chapter 4.0 - Sweep Mode Operation / 08
SWEEP MODE OPERATION
Touch the step size indicator to cycle through step sizes until the desired step size is displayed. Step size is displayed in the unit of measure that is selected by touching the laser output in the center of the display. Available step sizes are 0.4, 0.8 and
1.6nm for wavelength, 50, 100 and 200GHz for frequency, and .5, 1 and 2 for channels.
Touch the power value and a numeric keypad will be displayed. Enter the desired power value within the ranges set at the top of the display and touch OK.
Touch the dwell time and a numeric keypad will be displayed. Enter a value from 2 to 60 seconds.
Continued
Touch and hold the high end slide and drag it to the desired start point for the sweep, or touch and release the slide. The selection arrows at the button of the display will change to green and can be used to step or snap the high channel to position.
Touch and hold the low end slide and drag it to the desired end point for the sweep, or touch and release the slide. The selection arrows at the button of the display will change to red and can be used to step or snap the low channel to position.
Touch the laser icon or the laser start/pause to energize the. Touch a second time to turn o the laser. The Active output slide will move at the selected step size between high and low end channels (inclusive). The sweep will return to the beginning and continue until the laser icon or laser start/paused is touched again.
or
or
or
ChallengerOptics.com
Wavelength Specic Optical Testing and Measurement Equipment
ChallengerOptics.com
Wavelength Specic Optical Testing and Measurement Equipment
Chapter 5.0 - VFL Operation / 09
VFL OPERATION
Return to the HOME SCREEN.
Touch the VFL Icon ONCE to turn on the VFL
Touch the VFL icon again to change the laser output to FLASHING.
Touch the icon again to TURN OFF the laser.
notes
Loading...