Chaffoteaux & Maury BRITONY II.T Instructions For Use & Warranty

Page 1
BRITONY II.T
Nat - G.C. N° 52 980 04
LPG - G.C. N° 52 980 09
instructions for use
Remove protective film before use
Purpose provided room ventilation is not required since the air for the burner is taken from
outside the house. The flue goes directly through the wall behind the heater
It is the law that all gas appliances are installed by competent persons in accordance
with the above regulations. Failure to install appliances correctly could lead to prosecution.
It is in your own interest and that of safety to ensure compliance with the law.
CONFORMS WITH EUROPEAN STANDARD E N 26
C
C
*
+
-
Page 2
*
+
-
*
+
-
*
+
-
*
+
-
TO LIGHT THE HEATER
1) (fig. 1) With all hot taps closed, light the heater by turning the gas control knob to
the position marked . If the pilot, which can be seen through the window, does not light, leave the knob in this position for a few moments. Return the knob to the «off» position «
» and repeat.
2) When the pilot is alight, wait 10 seconds then turn the gas control knob slowly to the full gas position (fig. 2).
The heater is now ready for use, and will light when a hot tap is opened.
If the pilot goes out, repeat operations 1 and 2. When the control knob is turned back to the «off» position, it may not be possible to turn it immediately to the pilot position - if so, wait 30 seconds for the safety device to reset itself.
TO TURN OFF THE PILOT
If the heater is not required to be used for some time, the pilot can be turned off. Turn the control knob clockwise to the position as shown in fig. 3.
USING THE HEATER
Light the pilot as previously describeb and turn the gas control knob to the position shown in fig. 2. Turn on a hot water tap.
Adjust the lower control knob on the water heater to the required temperature. Turning it anti-clockwise to the position shown in fig. 4 will give a lower water tempe­rature.
FROST PRECAUTIONS
If there is any risk of freezing, the heater should be drained.
1) Turn off the pilot.
2) Turn off the cold water supply to the heater with the tap fitted below (A) (fig. 5). Slide the plastic trim forward to improve access.
3) Open an adjacet hot water tap.
4) Remove the drain plug (B) (fig. 5), and drain the water into a basin.
To restart the heater replace the drain plug and open the cold water supply tap.
Check that water flows through the heater before lighting the pilot.
SERVICE
To ensure that the heater continues to work efficiently and has a long life, it is important that it is serviced annually. Ask your installer or BRISTISH GAS for details of a regular service scheme, or your local Chaffoteaux et Maury service centre.
This water heater has been tested and approved by British Gas to the relevant British Standards.
This water heater is suitable for use with showers and automatic washing machines.
For further information, ask your installer or contact Chaffoteaux et Maury Limited.
Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5
Réf. : 91120128c - 02/2003
Chaffoteaux & Maury are continuously improving their products and therefore reserve the right to change specifications without prior notice and accepts no liability for any errors or omission in the information contained in this document.
Manufacturer: Chaffoteaux & Maury - France
Commercial subsidiary: MTS (GB) Limited
MTS Building Hughenden Avenue High Wycombe Bucks HP13 5FT Telephone: (01494) 755600 Fax: (01494) 459775 internet: www.chaffoteaux.co.uk E-mail: info@mtsgb.ltd.uk
Technical Support Help Line: (01952) 222288
Loading...