BRITONY SYSTEM PLUS 60
Appliance category .................................... Cat II 2H 3+
Heat input C/H & DHW
Maximum in kW.. ................................ 20.22
Maximum in Btu/h ............................... 69005
Heat output C/H & DHW
Maximum in kW.. ................................ 18
Maximum in Btu/h ............................... 61428
C/H circuit pressures
Min operating in bar 0.7
in ib/in*
Max operating in bar
:p5
in ib/in2 36.6
Safety discharge
in bar.. ................................................. 3
in ib/in3 ................................................ 43.5
Expansion vessel
Pre-charge pressure in bar.. ............... 0.7
Pre-charge pressure in lb/in2 .............. 9.4
Net capacity at 3 bar in litre ................ 5.44
NATURAL GAS G20
Gas rate
Maximum in m3/h ................................ 2.14
Maximum in ff/h ................................. 76
Inlet pressure
Nominal in mbar ................................. 20
Nominal in in wg ................................. 8
Burner pressure
Nominal in mbar ................................. 6.7
Nominal in in wg ................................. 2.7
Burner injector diameter
Natural gas G20 in mm.. ..................... 1.23
PROPANE L.P.G. G31
Gas rate
Maximum in kg/h ................................ 1.55
Maximum in fRh ................................. 3.42
Inlet pressure
Nominal in mbar ................................. 37
Nominal in in wg ................................. 14.8
Burner pressure
Nominal in mbar ................................. 21 .O
Nominal in in wg ................................. 8.4
BUTANE L.P.G. G30
Gas rate
Maximum in kg/h ................................ 1.58
Maximum in Lbs/h .............................. 3.48
Inlet pressure
Nominal mbar ..................................... 28
Nominal in in wg ................................. 11.2
Burner pressure
Nominal in mbar .................................
Nominal in in wg .................................
Burner injector diameter
LPG G30 and G31 in mm ................... 0.70
Adjustable by-pass
Minimum flow rate in I/h ...................... 100
Minimum flow rate in gal/min .............. 0.36
Maximum flow rate in I/h ..................... 700
Maximum flow rate in gal/min ............. 2.56
Electrical characteristics
Supply.. ............................................. 230V - 50Hz
Consumption ............................................. 150W
Protection ........................................... IP 44
Fuse no 1 ............................................ 2A
Fuse no 2 ............................................ 1.25A
External controls ................................. 24V
DUO 55 CYLINDER
Storage capacity in litre ............................. 55
Max water supply pressure to
pressure reducing valve ............................ 12 bar
Operating pressure ................................... 3 bar
Expansion vessel charge pressure ........... 3 bar
Expansion valve setting.. ........................... 6 bar
Maximum primary working pressure ......... 3.5 bar
Set opening pressure of combined
temperature and pressure relief valve.. ..... 90°C
....... 7 bar
Heating capacity of the primary heat
exchanger ................................................. 23 kW
Heating duration
(primary temperature
90°C
flow @
Im3/hr DHW temperature @ 15°C
raised to 65°C in mins)
............................. 17 min
Consumption per day to maintain
the temperature @ 65°C in kWhr/24hr ...... 0.04
70% reheat time ........................................ 13 min
WEIGHTS
Britony System Plus 60
With packaging.. ........................................ 43.2 kg
Without packaging.. ................................... 41.2 kg
Lift weight .................................................. 35.2 kg
Cylinder
Weight when empty.. ................................. 33 kg
Weight when full ........................................ 90 kg
MINIMUM CLEARANCES
Both sides ................................................. 5 mm
Above casing ............................................. 170 mm
Below casing ............................................. 200 mm
Front (for servicing) ................................... 500 mm
Front (in operation) .................................... 5 mm
OUTER CASE DIMENSIONS FOR CYLINDER &
BOILER
Width ......................................................... 440
(minimum space required 450)
Height.. ...................................................... 850
Depth.. ....................................................... 380
Minimum space required when cylinder
and boiler fitted side by side ...................... 895
4