CGP Instruments LP. RedSnake IL-200 User Manual

Introduction
The RedSnake Infrared Link (IL-200) communication port serial adapter is developed to give the user possibility to easily transfer files between a desktop computer and a device (notebook, palmtop computers, mobile phones) with a built-in IrDA compliant infrared interface, without using cable connections.
Features
- Wireless infrared data communication
- Communication distance 0 cm – 150 cm
- No external power necessary
Accessories
- Infrared head with 1,5 meter length cable
- User’s manual
- Adhesive tape
Installing
System Requirements
- Pentium or 486DX based PC compatible computer
- Free serial communication port (COMx).
- Installation CD of Windows 95/98/ME/2000 operation system.
Installing Hardware
- Turn off the PC.
- Locate a COM (serial) port on the back of your PC. Most COM ports use 9-pin male
connectors.
Note:
If all your PC’s COM ports are already used by a mouse and/or an external modem, you must install an add-in board with additional COM ports.
- Insert the connector of RedSnake in the 9-pin COM port. Note: If your PC has a 25-pin connector, you must use a 9-pin to 25-pin converter. Warning!!! Do not remove the connector of RedSnake until PC is turned on! In case if you do, please
restart your computer.
Installing the Infrared Support for Windows 95/98/2000 software
-
Windows Millennium Edi tion (ME)
double click the Irdasir.reg file, and select Yes to update
the registry. Irdasir.reg is located on Windows ME CD in TOOLS\PSSUTIL directory.
- Start the Add New Hardware in Start menu / Settings / Control Panel.
- Follow the prompts until it asks you ‘ Do you want Windows to search for new hardware? ‘. Choose ‘No, I want to select the hardware from a list’.
- Follow the prompts until it asks you to select the type of hardware you want to install. Choose ‘Infrared devices’ from the list.
- Windows 95 and 2000
follow the prompts again until it asks you to select Manufacturer and
Infrared Device. Choose the ‘ACTiSYS’ and ‘ACT-IR220L Infrared Wireless Interface’.
-
Windows 98 and ME
follow the prompts again until it asks you to select Manufacturer and Infrared Device. Choose the ‘Infrared COM port or dongle’ and ‘Generic Infrared Serial Port or dongle’. Next window asks you to select the ‘Infrared Transceiver. Choose ‘ACTiSYS 220L’.
- Follow the prompts until it asks you to select a Communications Port. Choose the COM port the IL-200 is physically connected.
- Follow the prompts again until it asks you what default ports to use. If your c omputer has two parallel port (LPT1, LPT2) and two serial ports and one internal modem (COM1, COM2, COM3) use the COM4 and LPT3 setting.
- Click on „Finish”, your driver is installed successfully.
-
Windows 98 Second Edition (SE) and ME
use Registry Editor (Regedit.exe) to locate the EnablePowerManagement value in the following registry key: HKEY_LOCAL_MACHINE\System\CurrentControlSet\Services\VxD\VCOMM. On the Edit menu, click Modify, change 01 to 00, and then click OK. Quit Registry Editor and Reboot.
Usage of Infrared driver software (Windows 95/98)
- Go to „Control Panel” and double click the icon called „Infrared”.
- Under the „Options” index select the „Enable communications on ...”, then click on „Apply”.
- Under the „Preferences” index, check all the check box and click on „OK”
- You should see the Infrared Monitor icon in the right hand corner of the taskbar.
Usage of Wireless Link software (Windows ME)
- Go to „Control Panel” and double click the icon called „Wireless Link”.
- Set the maximum communication speed and communication port in window Control Panel/Network ‘Generic Infrared Serial Port or dongle’ Properties/Advanced.
Usage of Wireless Link software (Windows 2000)
- Go to „Control Panel” and double click the icon called „Wireless Link”.
- Enable or disable the communication in window Hardware / Properties / General menu Device usage.
- Set the maximum communication speed in window IrDA Settings menu Maximum Connection Rate.
Specification
Type: RedSnake Infrared Link IL-200
Carrier: Infrared radiation (peak wavelength: 850 to 1050 nm) Communication distance: Between 0 cm and 100 cm Transmission speed: 9.6, 19.2, 38.4, 57.6 and 115.2Kbps Dimensions (WxLxH): 5mm x 60mm x 17 mm Weight: ca. 60gr.
Technical Support
Please send any comments, suggestions or errors to : CGP Instruments LP.
Dália utca 10. H-2120 Dunakeszi HUNGARY Phone: +36 209 269 174, Email: info@cgpi.hu, Fax: +36 27 392 663
Users’ manual
for RedSnake IL-200 infrared (IrDA) communication port serial adapter
CGP Instruments LP. All rights reserved. This manual to herein are copyrighted works of CGP. This manual in whole
or in part in any form whatsoever must not be reproduced without written permission of CGP. The information in this document is subject to change without notice.
© Copyright CGP Instruments LP. 2000 RedSnake and RedSnake logo are registered trademarks of CGP Instruments LP. Some names referred to are registered trademarks.