CFM CX3000GS User Manual

CX3000GSCX3000GS Ducted Air PurifierDucted Air Purifier
Installation & Maintenance
Instructions
1
P
AGE
INSTALLATION INSTRUCTIONS
BEFORE INSTALLATION 2
INSTALLATION 2
TYPICAL HORIZONTAL SYSTEM 4
TYPICAL VERTICAL SYSTEM 4
WIRING DIAGRAM 5
OPERATION
AIR PURIFICATION 6
SAFETY INSTRUCTIONS 7
COST OF OPERATION 7
AIR CYCLES 7
PERFORMANCE DATA
AIRFLOW & RESISTANCE DATA 8
PARTICLE SIZE EFFICIENCY GRAPH 8
BACTERIA REDUCTION 9
PARTICULATE FILTRATION 9
PARTICLE REDUCTION 9
REMOVAL EFFICIENCY OF TYPICAL ALLERGENS 9
CARBON MONOXIDE REDUCTION 9
MAINTENANCE
SERVICE INTERVALS 10
REPLACING LAMPS 10
REPLACING FILTER 11
RESETTING SERVICE LIGHTS 11
PRODUCT SPECIFICATIONS
SPECIFICATIONS 12
REPLACEMENT PARTS 12
PARTS LIST 13
LIMITED WARRANTY
RREEAADD AANNDD SSAAVVEE TTHHEESSEE IINNSSTTRRUUCCTTIIOONNSS
TTAABBLLEE OOFF CCOONNTTEENNTTSSPPRROODDUUCCTT SSPPEECCIIFFIICCAATTIIOONNSS
IINNSSTTAALLLLAATTIIOONN IINNSSTTRRUUCCTTIIOONNSS
BBEEFFOORREE IINNSSTTAALLLLAATTIIOONN
1. Before installing the damage.
2. During handling and installation, take care to protect the honeycomb core of the photo-catalytic module. The titanium-aluminum core is very fragile and easily damaged.
3. Do not install insulation within 3 inches (75 mm) of the ultraviolet UVC lamps.
4. Access for service is required when mounting the or behind walls.
5. Do not install in such a manner that the interior photo-catalytic module may fall from an elevated position, and cause injury to people or equipment below.
1. Unscrew the two locking knobs and remove the inner module from the outer case.
2. Take care not to bend or distort the outer metal enclosure.
3. Ensure the unit is positioned so that the inlet, or return, air enters the side containing the MERV-11 electrostatic filter. (Fig. 1)
4. Mount the outer case to the support plenum. CAUTION: Use a screw length that will not penetrate the inside module containing the photo-catalytic mod­ule and MERV-11 electrostatic filter. There is only 1/2 inch of clearance between the outer case and inner module.
5. In the event the foot print of the air handler is larger or smaller than the outer metal enclosure of the fabricated from 18 ga. sheet metal. (Fig. 2)
6. Tape all seams between the air handler and the outlet side of the to ensure there can be no air bypassing the system.
7. Attach the air handler to the outlet side of the drilling sheet metal screws.
8. Slide the inner module into the outer case, and secure locking knobs finger tight only. Ensure the inner module can slide freely in and out of the outer case.
9. Plug the power cord into any 120 VAC outlet, and check both sight ports to ensure both lamps are illuminated. The ultraviolet lamps must remain on at all times.
10. Check the sequence for 15 seconds. The FILTER light should then turn flashing green, and the LAMP light a steady green.
11. Set the HVAC fan to operate for at least 30 minutes every hour. If air quality problems persist after one week, increase the fan operating time by 5 minute intervals, until suitable air quality is achieved.
CCXX33000000GGSS
CCXX33000000GGSS DDuucctteedd AAiirr PPuurriiffiieerr
IINNSSTTAALLLLAATTIIOONN
CCXX33000000GGSS
service panel. The LED service lights should flash in
unit, suitable metal transitions should be
, inspect for any signs of
CCXX33000000GGSS
CCXX33000000GGSS
above ceilings
with #10 x 3/8 self-
CCXX33000000GGSS
2
3
Filter Side Catalyst side
TTRRAANNSSIITTIIOONNSS FFOORR IINN--DDUUCCTT MMOOUUNNTTIINNGG
FFiigg.. 11
IINNSSTTAALLLLAATTIIOONN IINNSSTTRRUUCCTTIIOONNSS
AAIIRRFFLLOOWW
Airflow
FFiigg.. 22
20 Degree Expansion Per Side (4 in. Per Linear Foot)
Return Air Duct Clean Air Out
Tr ansition
CX3000GS
#10 Screws Not Longer Than 1/2 in.
Tr ansition
100
99 98 97 96 95 94 93 92 91 90 89 88 87 86 85 84 83 82 81 80
Particle Size - Microns
Particle Reduction - First Pass
PARTICULATE FILTRATION
WHOLE HOME
PARTICLE REDUCTION
BACTERIA REDUCTION
Te st Period In Hours
Hours of Operation
1 2 3 4 5 6 7 8 9 10 11 12
CARBON MONOXIDE
REDUCTION
REMOVAL EFFICIENCY
OF TYPICAL ALLERGENS
0 15 30 45 60
0
1
17
30
42
65
Te st Room
15’ L x 15 W x 8’ H
Micro-organism Plate Count
Percent Reduction
100
90
80
70
60
50
40
30
20
10
0
2,300 Sq. Foot
Home
5.0
3.0
1.0
.5
.3
77.8
93.4
94.1
95.1
Start
Finish
Time In Hours
Parts Per Million - CO
1 2 3 4 5 6 7 8
250
225
200
175
150
125
100
75
50
25
0
99.9%
99.7%
99.5%
99.3%
99.1%
98.9%
98.7%
98.5%
98.3%
98.1%
97.9%
97.7%
97.5%
97.3%
97.1%
96.9%
96.7%
96.5%
96.3%
96.1%
IINNSSTTAALLLLAATTIIOONN IINNSSTTRRUUCCTTIIOONNSS
TTYYPPIICCAALL HHOORRIIZZOONNTTAALL SSYYSSTTEEMM
Gas Burners
Transition As Needed
TTYYPPIICCAALL VVEERRTTIICCAALL SSYYSSTTEEMM
Plenum
Airflow
Fan Coil Unit
CX3000GS Ducted Air Purifier
4
Loading...