CFM CX3000 User Manual

CX3000
Complete Air Purification System
Whole House Unit
[Duct Mounted]
User’s Guide
Read and save these
Instructions
Buffalo, NY, U.S.A.
TABLE OF CONTENTS
IMPORTANT SAFETY INSTRUCTIONS . . . . . . . . . . . . . . . . . . . . . .3
SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
OPERATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
CYCLE TIMES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
COST OF OPERATION . . . . . . . . . . . . . . . . . . . . . . . .5
SERVICE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
CHANGING THE FILTER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ..6
CHANGING THE UV LAMPS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
RESETTING THE SERVICE LIGHTS . . . . . . . . . . . . . . . . . . . . . . . . .8
REPLACEMENT FILTERS AND ULTRAVIOLET LAMPS . . . . . . . . . . . . . . . . . .8
INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
TYPICAL VERTICAL AND HORIZONTAL INSTALLATION . . . . . . . . . . . . . .10
LIMITED LIFETIME WARRANTY . . . . . . . . . . . . . . . . . . . . . . . . . . . .11
PERFORMANCE DATA AND APPROVALS. . . . . . . . . . . . . . . . . . . . . . . .12
WIRING DIAGRAM . . . . . . . . . . . . . . . . . .. . . . . . . . . . .13
PARTS LIST . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
CX3000 EXPLODED VIEW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Before installing the CX3000 purifier, inspect for any signs of damage. During handling and installation, take care to protect the catalytic hon- eycomb side of the product from physical damage, as the aluminum-tita- nium core is very soft and can be easily damaged.
Warning - Always unplug the power cord from the CX3000 air purifier when changing the filter or ultraviolet lamps. Never look into a burning ultravi- olet lamp without proper eye protection as severe damage to the eyes can result. This product is rated for standard ambient air temperatures during heating and air-conditioning functions and not rated for elevated air tem- peratures in excess of 125 degrees fahrenheit.
Do not attempt to clean the catalytic honeycomb core with cleaning solutions. The catalyst is radiated with short wave ultraviolet light during periods of non-air flow and is self-cleaning.
Do not install insulation within 76MM or 3 inches of Luminaries.
Access for service is required when mounting above ceilings or behind walls.
Do not install in a position where the interior module can fall from an elevated position and cause injury to people or equipment below.
Manufacturer: Continental Fan Manufacturing Inc. Model: CX3000 Voltage: 1/120V/60 Dimensions: 21" W x 25" H x 10.25" D Amps: 0.38 Watts: 44.8 Caution: Risk of fire - replace only with SP20T10 / 20 watt
Fuse: Replace only with AGC-l fuse Max Face Velocity: 625 fpm Max Air Flow: 2170 cfm UV Range: 254 NM (germicidal) Weight: 42 LBS Application: 3000 Sq. Feet Catalyst: Titanium Dioxide Particle Filter: Electrostatic Needled MERV -11 Service: UV LAMPS - 1 year
32
IMPORTANT SAFETY INSTRUCTIONS
Before installing the CX3000 purifier, inspect for any signs of damage. During handling and installation, take care to protect the catalytic hon- eycomb side of the product from physical damage, as the aluminum-tita­nium core is very soft and can be easily damaged.
Warning - Always unplug the power cord from the CX3000 air purifier when changing the filter or ultraviolet lamps. Never look into a burning ultravi­olet lamp without proper eye protection as severe damage to the eyes can result. This product is rated for standard ambient air temperatures during heating and air-conditioning functions and not rated for elevated air tem­peratures in excess of 125 degrees fahrenheit.
Do not attempt to clean the catalytic honeycomb core with cleaning solutions. The catalyst is radiated with short wave ultraviolet light during periods of non-air flow and is self-cleaning.
Do not install insulation within 76MM or 3 inches of Luminaries.
Access for service is required when mounting above ceilings or behind walls.
Do not install in a position where the interior module can fall from an elevated position and cause injury to people or equipment below.
SPECIFICATIONS
Manufacturer: Continental Fan Manufacturing Inc. Model: CX3000 Voltage: 1/120V/60 Dimensions: 21" W x 25" H x 10.25" D Amps: 0.38 Watts: 44.8 Caution: Risk of fire - replace only with SP20T10 / 20 watt
UV-C lamps Fuse: Replace only with AGC-l fuse Max Face Velocity: 625 fpm Max Air Flow: 2170 cfm UV Range: 254 NM (germicidal) Weight: 42 LBS Application: 3000 Sq. Feet Catalyst: Titanium Dioxide Particle Filter: Electrostatic Needled MERV -11 Service: UV LAMPS - 1 year
FILTERS - 6 months
OPERATION
The CX3000 installs in the air-inlet side of any heating and air condi­tioning system, up to five tons in size. Operation of the air-handler fan
unit is required for air purification and sterilization to take place.
Note: The ultraviolet lamps are wired to operate continuously. This fea­ture allows the catalyst to burn off surface impurities, while cleaning and reactivating itself during periods of no airflow. The cost of operation is less than .07 cents per day. See operating cost section.
The CX3000 combines three unique technologies to protect people against indoor air pollutants. Photo-Catalytic Titanium Oxidation, com­bined with high efficiency electrostatic MERV-11 particulate filtration, and germicidal ultraviolet lights, quickly reduce and eliminate toxic gas phase chemicals, lung damaging dust and airborne germs from the living environment.
Many new homes have smart programmable thermostats that allow for automatic operation of the air-handler fan unit when there is no demand for heating or air conditioning. It is important that the CX3000 operates at least (25) minutes per hour (24) hours per day to remove toxic mate­rials from the indoor environment.
The length of operation depends on the location of the home or office in relation to point source pollution such as refineries, processing plants, automobile traffic, and areas that produce high levels of pollen. Individuals that are sensitive to mold spores, dust mites and chemicals, or have respiratory problems such as asthma, emphysema, and chronic aller­gies, should extend the run time to at least (40) minutes per hour.
To obtain maximum benefit from the CX3000 air purification system, it is recommended that the air-handler fan be set to run continuously.
Fan unit on 10 minutes per hour Air cycled (1) -------- times per hour Fan unit on 15 minutes per hour Air cycled (1.3) ------ times per hour Fan unit on 20 minutes per hour Air cycled (1.75) ---- times per hour Fan unit on 30 minutes per hour Air cycled (2.62) ---- times per hour
Fan unit on 10 minutes per hour Air cycled (24) ------- times per day Fan unit on 15 minutes per hour Air cycled (31) ------- times per day Fan unit on 20 minutes per hour Air cycled (42) ------- times per day Fan unit on 30 minutes per hour Air cycled (63) ------- times per day
Note: In the event the existing thermostat does not have the capability to operate the air-handler fan unit independently of a demand for heating or air-conditioning, it is highly recommended that an (Air Cycler) be installed.
This device is simply wired in parallel with the existing thermostat wire and can be programmed to turn on the air handler fan unit for any desired interval. A memory tracks the time the fan unit operates every hour and only cycles the fan unit that hour if normal requirements for heating and air conditioning have not cycled the fan unit long enough to meet air purification requirements.
The Air Cycler can be sourced from Shelter Supply, Lakeville, MN (1-800- 762-8399) or (www.Air Cycler.com) on the web.
Electricity cost per kilowatt hour .06 kw hr. .08 kw hr. .10 kw hr
CX3000 (32.25 kw hours) per month = $1.93 $2.58 $3.22
During periods where the fan unit is being operated for the sole purpose of air purification, running a 1/2 horsepower fan unit will add approxi- mately $5.36 per month to the normal operating cost. However, this cost is easily offset in savings on medication, doctors office visits, mechanical maintenance and cleaning of fan units, refrigeration coils, dirty air ducts, and last but not least, less house cleaning.
54
CYCLE TIMES
AIR CYCLES PER HOUR
(Based on 3000 sq. ft.) Fan unit on 10 minutes per hour Air cycled (1) -------- times per hour Fan unit on 15 minutes per hour Air cycled (1.3) ------ times per hour Fan unit on 20 minutes per hour Air cycled (1.75) ---- times per hour Fan unit on 30 minutes per hour Air cycled (2.62) ---- times per hour
AIR CYCLES PER DA
Y
Fan unit on 10 minutes per hour Air cycled (24) ------- times per day Fan unit on 15 minutes per hour Air cycled (31) ------- times per day Fan unit on 20 minutes per hour Air cycled (42) ------- times per day Fan unit on 30 minutes per hour Air cycled (63) ------- times per day
Note: In the event the existing thermostat does not have the capability to operate the air-handler fan unit independently of a demand for heating or air-conditioning, it is highly recommended that an (Air Cycler) be installed.
This device is simply wired in parallel with the existing thermostat wire and can be programmed to turn on the air handler fan unit for any desired interval. A memory tracks the time the fan unit operates every hour and only cycles the fan unit that hour if normal requirements for heating and air conditioning have not cycled the fan unit long enough to meet air purification requirements.
The Air Cycler can be sourced from Shelter Supply, Lakeville, MN (1-800-
762-8399) or (www.Air Cycler.com) on the web.
COST OF OPERATION
Electricity cost per kilowatt hour .06 kw hr. .08 kw hr. .10 kw hr
CX3000 (32.25 kw hours) per month = $1.93 $2.58 $3.22
During periods where the fan unit is being operated for the sole purpose of air purification, running a 1/2 horsepower fan unit will add approxi­mately $5.36 per month to the normal operating cost. However, this cost is easily offset in savings on medication, doctors office visits, mechanical maintenance and cleaning of fan units, refrigeration coils, dirty air ducts, and last but not least, less house cleaning.
1 . Remove filter as in Fig. - 1.
2. Reach inside and rotate UV lamp 1/4 turn in either direction and remove. Fig. - 3
3. Carefully place new lamp back into inner case so that the pins line up with the slot on lamp holders at each end. Fig. - 4
4. Slide the new lamp down into the lamp holders and rotate 1/4 turn.
5. Replace filter and slide module into outer case. Tighten locking knobs finger-tight.
6. IMPORTANT: Make sure AIR FLOW arrow on filter is facing the air-
inlet side of the air handler.
7. Plug in power cord and check sight ports for lamp illumination.
SERVICE
The CX3000 comes with a built-in computerized service panel to automati­cally keep track of service intervals. Indicator lights will tell you when to change filter and ultraviolet lamps (30) days in advance.
MERV-11 Filter . . . . . change every (6) months . . . . . service light turns
from green to yellow after five months, and to red after six months.
UV Lamps . . . . . change every (12) months . . . . . service light turns
from green to yellow after eleven months, and to red after twelve months.
CHANGING THE FILTER
1 . Unplug the power cord from the CX3000. Unscrew the two locking
knobs and pull out the inner module.
2. Loosen Phillips head screws on filter retainer plates and remove plates - Fig - 1
3. Remove old filter and replace with new filter. Make sure airflow arrow on filter is pointing to the inside of module.
4. Replace filter retainer plate and tighten Phillips head screws.
76
CHANGING THE UV LAMPS
1 . Remove filter as in Fig. - 1.
2. Reach inside and rotate UV lamp 1/4 turn in either direction and remove. Fig. - 3
3. Carefully place new lamp back into inner case so that the pins line up with the slot on lamp holders at each end. Fig. - 4
4. Slide the new lamp down into the lamp holders and rotate 1/4 turn.
5. Replace filter and slide module into outer case. Tighten locking knobs finger-tight.
6. IMPORTANT: Make sure AIR FLOW arrow on filter is facing the air-
inlet side of the air handler.
7. Plug in power cord and check sight ports for lamp illumination.
8 9
1. Unscrew the two locking knobs and remove the inside module from the outer case.
2. Take care not to bend or distort the outer metal enclosure.
3. Mount the outer case to the support plenum. Note: Do not use a
screw length that will extend into or penetrate the inside module containing the catalyst or filter.
4. In some cases, the foot print of the air handler may be larger or smaller than the outer enclosure of the CX3000. A metal adapter plate of 18 ga. sheet metal should be fabricated to make a suitable transition. Fig. - 7
RESETTING THE SERVICE LIGHTS
On the right side of the service panel, there are arrows pointing to two small holes marked RESET. One is marked FILTER, and one is marked LAMP. Insert a pin or similar object into the hole corresponding to the replacement component, and push lightly until the service light returns to the green position. The computer is now reset. Fig. - 5
REPLACEMENT FILTERS AND ULTRAVIOLET LAMPS
Replacement components are available in the form of a yearly replace­ment kit, comprising (2) filters and (1) set of UV lamps. Replacement kits are avail­able from your local HVAC wholesaler.
INSTALLATION
Make sure to install the CX3000 so that the inlet, or return air, enters the side containing the MERV-11 particle filter first. Fig. - 6
SERVICE PANEL
FIG. -5
FIG. -6
5. Tape all seams between the air handler and the outlet side of the
CX3000 so there can be no air bypassing the system.
6. Attach the air handler to the outlet side of the CX3000, and fasten with
#10 x 3/8 self-drilling sheet metal screws. NOTE: Only 1/2 inch of clearance has been provided between the outer and inner case.
7. Slide the inner module into the outer encasement and tighten locking
knobs finger-tight. Make sure the inner module will freely slide in and out of the outside enclosure.
8. Plug in the power cord to any 120vac outlet and check both sight ports
to make sure both lamps are illuminated. Ultraviolet lamps must remain on at all times regardless of thermostat or Air Cycler settings.
9. Check the service panel. The LED lights should flash in sequence for 15
seconds and then return to green. The filter lamp should be flashing green and the UV lamp light should be a steady green.
10. Set the thermostat or the Air Cycler to operate the fan unit for at least
25 minutes every hour. If air quality problems persist after one week, increase the fan unit operating time by (5) minute intervals.
1. Unscrew the two locking knobs and remove the inside module from the outer case.
2. Take care not to bend or distort the outer metal enclosure.
3. Mount the outer case to the support plenum. Note: Do not use a
screw length that will extend into or penetrate the inside module containing the catalyst or filter.
4. In some cases, the foot print of the air handler may be larger or smaller than the outer enclosure of the CX3000. A metal adapter plate of 18 ga. sheet metal should be fabricated to make a suitable transition. Fig. - 7
5. Tape all seams between the air handler and the outlet side of the
CX3000 so there can be no air bypassing the system.
6. Attach the air handler to the outlet side of the CX3000, and fasten with
#10 x 3/8 self-drilling sheet metal screws. NOTE: Only 1/2 inch of clearance has been provided between the outer and inner case.
7. Slide the inner module into the outer encasement and tighten locking
knobs finger-tight. Make sure the inner module will freely slide in and out of the outside enclosure.
8. Plug in the power cord to any 120vac outlet and check both sight ports
to make sure both lamps are illuminated. Ultraviolet lamps must remain on at all times regardless of thermostat or Air Cycler settings.
9. Check the service panel. The LED lights should flash in sequence for 15
seconds and then return to green. The filter lamp should be flashing green and the UV lamp light should be a steady green.
10. Set the thermostat or the Air Cycler to operate the fan unit for at least
25 minutes every hour. If air quality problems persist after one week, increase the fan unit operating time by (5) minute intervals.
CX3000
Each CX3000 Complete Air Purification System comes with a limited life- time warranty, excluding expendable parts such as filters and UV lamps.
This warranty provides for repair or replacement of any defective parts or components for two years from the date of purchase at no charge for labor or materials. This warranty does not cover the expendable UV lamps, which must expendable filter cartridge media, which must months. Continental Fan Manufacturing Inc. is not responsible for the installation of this product. This warranty does not cover faulty installa- tion or damage to personal property resulting from incorrect or faulty installation. This warranty does not cover the cost for removal or reinstal- lation of the CX3000 when service or warranty work is required. All war- ranty repair work must be performed either at the factory or by a factory certified service center. Shipping cost to the factory or service center is the responsibility of the owner of the CX3000. To return product for war- ranty repair, the customer must first contact the factory for a Return Materials Authorization (RMA) number and a ship to address, as it may dif- fer from the manufacturing location. For material repaired under warran- ty, shipping costs to the customer will be prepaid for the first two years only. This warranty is provided to the original purchaser of the CX3000, and may not be transferred, sold or bartered. This product is not war- ranted against freight damage, failure resulting from misuse, connection to incorrect voltage, or acts of God such as fires, earthquakes, or floods.
HORIZONT
AL INSTALLATION
1110
Each CX3000 Complete Air Purification System comes with a limited life- time warranty, excluding expendable parts such as filters and UV lamps. This warranty provides for repair or replacement of any defective parts or components for two years from the date of purchase at no charge for labor or materials. This warranty does not cover the expendable UV lamps, which must
be replaced on an annual basis (1-year), or the
expendable filter cartridge media, which must
be replaced every six months. Continental Fan Manufacturing Inc. is not responsible for the installation of this product. This warranty does not cover faulty installa­tion or damage to personal property resulting from incorrect or faulty installation. This warranty does not cover the cost for removal or reinstal­lation of the CX3000 when service or warranty work is required. All war­ranty repair work must be performed either at the factory or by a factory certified service center. Shipping cost to the factory or service center is the responsibility of the owner of the CX3000. To return product for war­ranty repair, the customer must first contact the factory for a Return Materials Authorization (RMA) number and a ship to address, as it may dif­fer from the manufacturing location. For material repaired under warran­ty, shipping costs to the customer will be prepaid for the first two years only. This warranty is provided to the original purchaser of the CX3000, and may not be transferred, sold or bartered. This product is not war­ranted against freight damage, failure resulting from misuse, connection to incorrect voltage, or acts of God such as fires, earthquakes, or floods.
LIMITED LIFETIME WARRANTYTYPICAL VERTICAL AND
PERFORMANCE DATA AND APPROVALS
CX3000
Air flow &
Resistance Data
Air Flow (cfm) Resistance (in w.g.) Air Velocity (fpm)
1250 0.18 360
1500 0.20 432
1750 0.25 504
2000 0.35 576
2250 0.42 648
2500 0.55 720
1312
WIRING DIAGRAM
CX3000
PARTS LIST
CX3000
ITEM PAR
T QTY DESCRIPTION
1 BL002 2 120 V 60 Hz. 420MA Ballast 2 BL007 1 120V 60Hz 12V 1-Amp Transform 3 EL018 1 Electron Terminal Block 4 LB016 1 CFM Embossed Label 5 EL029 1 Duct Display Board 6 MT042 1 Duct Control Cover 7 EL000 1 Fuse Holder 8 EL001 1 Fuse
9 EL028 1 Duct Electrical Receptacle 10 F1016 1 Power Guard PWG-404 Filter 11 MT014 2 Filter Holding Brackets 12 MT039 3 Duct Braces 13 HD072 2 Brass Key Tag 14 HD066 2 Plastic Lock Knob 15 HD065 1 Southco B8-66 Handle 16 FS00 1 1 3/16 T x 3/8 W Foam Tape 17 MT044 1 Duct Filter Enclosure Assembled 18 EL027 4 Lamp Socket 19 LT012 2 20 Watt UV Lamp 20 MT040 2 UV Lamp Reflector 21 EL014 2 #125-5 Starter Holder 22 EL015 2 FS5C Starter 23 HD029 2 Window Plug 24 EL016 1 Micro Switch 25 AL000 2 Aluminum Honeycomb Grid 26 AL002 1 1/2 Face T-Molding 27 CD009 1 Detachable Power Cord 28 HD002 34 10-32 x 3/8 PP. Type F 29 HD067 2 10-32 x 3/4 P.P. Type F 30 HD073 2 8-32 Hex Nut 31 HD074 2 8-32 x 1/2 RR Machine Screw 32 MT013 1 PVC Spring Clip 33 MT043 1 Duct Filter Cabinet Enclosure 34 FS000 1 1/2 Foam Seal Tape
1514
EXPLODED VIEW
CX3000
Continental Fan Manufacturing Inc.
203 Eggert Road
Buffalo, New York 14215
Tel: 800-779-4021 Fax: 716-842-0611