CFM CX1000 User Manual

CX1000
Complete Air Purification System
Portable Unit
User’s Guide
Read and save these
Instructions
Continental Fan Manufacturing Inc.
TABLE OF CONTENTS
IMPORTANT SAFETY INSTRUCTIONS . . . . . . . . . . . . . . . . . . . . . . . . . .3
SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
FEATURES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
UNPACKING THE CX1000 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
INSTALLING THE CX1000 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
USING THE CX1000 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
SELECT ROOM SIZE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
SELECT OPERATING MODE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
MONITORING OPERATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
SERVICE PANEL INDICATOR LIGHTS . . . . . . . . . . . . . . . . . . . . . . . . . . .8
UV LAMP INDICATOR LIGHTS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
FILTER INDICATOR LIGHTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
PERFORMING MAINTENANCE . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
REPLACING THE UV LAMP. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
REPLACING THE FILTERS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
LIMITED LIFETIME WARRANTY . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
IMPOR
Always unplug the CX1000 when it is not in operation, while the filters or UV light are being changed, and when cleaning the unit.
After servicing the unit, both the front and top grill assemblies must be reinstalled in exactly the same manner as prior to removal. If either grill is not reinstalled properly, the CX1000 will not function. This is a built- in safety feature.
Before using the CX1000, extend the power cord and inspect for any signs of damage. Do not use the unit if the power cord has been damaged.
Warning - This appliance is designed to be used on a flat and level sur­face, and may not work properly on an uneven surface. To reduce the risk of electric shock and injury, do not place in a window. Always place the CX1000 at least 12 inches (30 centimeters) away from heat sources such as stoves, radiators, or heaters.
Do not move the CX1000 while it is in operation. Always unplug the unit prior to moving it.
Do not immerse the CX1000 in water, as permanent damage will occur.
Read and save these instructions.
TANT
SAFETY INSTRUCTIONS
SPECIFICA
Manufacturer: Continental Fan Manufacturing Inc. Model: CX1000 Voltage: 1/120V/60 Dimensions: 21.5" W x 18.0" H x 8.0" D Maximum Amps: 0.95 Maximum Watts: 110 Max Air Flow: 265 cfm UV Range: 254 NM (germicidal) Weight: 23 LBS Application: 1000 sq. feet (auto mode)
2000 sq. feet (super mode) Catalyst: Titanium Dioxide Pre-Filter: 5 micron HEPA Filter: 0.3 micron hospital grade Service: UV LAMP - 1 year
FILTERS - 2 years
TIONS
32
Thank you for purchasing the CX1000 Complete Air Purification System. This unit features unique air purification technologies not found in any other air purifier.
Only CX1000 combines these features:
A quiet, energy efficient, backward-curved motorized impeller that
moves 265 cfm of air.
An advanced electronic control system that monitors air quality, room
occupancy, air flow, and filter and UV lamp replacement time.
A six-stage filtration system with gas adsorption media that removes
toxic gas, organic hydrocarbons, exhaust fumes, formaldehyde, clean­ing chemicals, low-level ozone, unpleasant odors, and paint solvents.
A hospital-grade, three-stage HEPA filter that removes allergens such
as pollen, mold fugal spores, tobacco smoke, insecticide dust, dust mites, and particles as small as 0.3 microns.
A photo-catalytic oxidation chamber that controls the spread of air-
borne disease in the home environment. UV light kills viruses and bac­teria on contact.
Photo-Catalytic Titanium Oxidation, activated by the UV light,
destroys airborne impurities too small to be filtered out. Small amounts of residual activated oxygen and negative ions keep the air clean and fresh, in exactly the same way sunlight and oxygen clean the air we breathe in an outdoor environment.
FEATURES
UNPACKING THE CX1000
Before unpacking the unit, inspect the shipping container for visible dam­age. If you feel that you may have received the unit in a damaged condi­tion, notify the shipper or supplier before opening the container. Remove the unit from the box and inspect it for damage. Handle it carefully. Do not drop it!
INSTALLING THE CX1000
CAUTION: THIS PRODUCT IS DESIGNED FOR INDOOR USE ONLY!
Place the CX1000 in a location that will not restrict air flow through either the air inlet or the air outlet. Plug in the electric cord at the nearest electrical wall outlet.
USING THE CX1000
1. Press POWER button to turn on the CX1000. Lights on the control
panel (figure 1) will light and the UV lamp will be on.
figure 1
2. Look into the air outlet at the top of the CX1000 to confirm that
the UV lamp is operating. There is a faint blue glow when the lamp is on. If the lamp appears to be off, refer to UV LAMP INDICATOR LIGHTS (page 8).
When the lamp is on, the product is ready for operation.
54
SELECT
ROOM SIZE
1. Determine the area of the room the CX1000 is to purify.
2. From the table below, identify the respiratory condition the unit is
to serve.
3. Use the Heavy Duty chart if you suffer
severe allergic reactions when exposed to particulate matter (pollen, dust, dust mites, animal dander, etc.) or airborne chemicals (pesticides, herbicides, clean­ing solutions, etc.)
4. Use the Light Duty chart if you occasion-
ally suffer from mild allergies.
5. Select the desired ROOM SIZE by pressing the SELECT button (figure 2).
figure 2
Heavy Duty
People with Severe Respiratory Problems
Super Mode SQ. FT SQ. METERS
Extra Large 650 65
Auto Mode SQ. FT SQ. METERS
Extra Large 550 55
Large 450 45
Medium 400 40
Small 350 35
X Small 300 30
Light Duty
Average home
Super Mode SQ FT SQ. METERS
Extra Large 2000 200
Auto Mode SQ FT SQ. METERS
Extra Large 1700 170
Large 1450 145
Medium 1200 120
Small 1050 100
X Small 900 90
SELECT OPERATING MODE
Select the desired operating MODE by pressing the SELECT button (figure 3).
AUTO MODE -- This is the mode most com-
monly used. In AUTO MODE, the Chemical Sensor (figure 1) controls the blower speed. If the Chemical Sensor detects an unhealthful amount of chemicals present in the air (indi­cated by the red light on the quality scale), the electronic controls will automatically increase blower speed.
SUPER MODE -- SUPER MODE may be select­ed during periods of high air pollution, such as when winds increase airborne dust and pollen, or during heavy room loading (parties or smoking). Blower speed will increase 25 percent above AUTO MODE.
ECONOMY MODE -- ECONOMY MODE saves energy when the room is unoccupied. When the Motion Sensor (figure 1) detects no motion for 30 seconds, blower speed is reduced to save electricity costs. The blower returns to normal speed when motion is again detected.
SLEEP MODE -- SLEEP MODE reduces the sound level by slowing blower speed by 30 percent, while still purifying room air at 70 percent of normal operation.
MONIT
The Chemical Sensor continually monitors air QUALITY, and in AUTO MODE, controls blower speed and air volume.
ORING OPERATION
figure 3
figure 4
Both air QUALITY and air VOLUME are dis­played on the INFORMATION panel. (figure 4).
Air QUALITY is indicated by one of five lights, indicating a range from GOOD to POOR (figure
4).
Air VOLUME is indicated by one of seven lights, representing a range from MAX to MIN (figure 4).
Set the CX1000 to move a volume of air appro­priate for room conditions. Note that measurements are relative to the selected room size. Make sure that the ROOM SIZE panel (figure 2) is always set for the room in which the unit is to operate.
76
8 9
SERVICE PANEL INDICATOR LIGHTS
The SERVICE panel (figure 5) indicates when maintenance is required. Lights on the SERVICE panel indicate if either the UV lamp or the air fil­ters will soon need to be replaced, or if they must be replaced before using the CX1000 again.
UV LAMP INDICATOR LIGHTS
The UV lamp has a useful life of one year (9,000) hours), with a one month grace period.
Green ON light is on - The lamp has been
in service for less than 12 months.
Yellow SERVICE SOON light is on - The
lamp has been in service for more than 12 months. The lamp should be replaced.
Red SERVICE NOW light is on - The lamp
has been in service for more than 13 months. The lamp may not be effective and must be replaced.
FIL
TER INDICATOR LIGHTS
The filters have a useful life of two years in a typical
residential environ-
ment.
Green ON light is on - The filters have been in service for less than
24 months.
Yellow SERVICE SOON light is on - The filters have been in service
for more than 24 months. The filters should be replaced.
Red SERVICE NOW light is on - The filters have been in service for
more than 25 months. The filters may not be effective and must be replaced.
figure 5
PERFORMING MAINTENANCE
Required Maintenance is:
Replace the UV lamp. (1 year)
Replace the filters. (2 years)
REPLACING THE UV LAMP
When the yellow SERVICE SOON lamp indicator lights, the UV lamp should be replaced within 30 days.
1. Unplug the power cord from the electrical outlet.
2. Using index fingers, squeeze the locking tabs (figure 6) inward
towards the center of the grill on top of the CX1000. Lift the grill and remove.
figure 6
3. Rotate UV lamp one-quarter turn, top-to-rear (figure 7), and remove
lamp.
figure 7afigure 7
4. Insert new UV lamp by rotating one-quarter turn (top-to-front).
5. Replace grill by pressing it into position until it locks. The alu-
minum reflector must be positioned over the lamp nearest the front of the unit. (figure 7a)
6. Reset UV lamp timer by lightly pressing the LAMP RESET button on
the Service Panel with a pin or similar object. The LAMP light will return to green and the time will be reset to zero.
REPLACING THE FILTERS
When the Yellow SERVICE SOON FILTER indicator lights, the filters should be replaced within 30 days.
1. Unplug the CX1000 power cord
from the electrical outlet.
2. Rest the CX1000 on its back (figure
8) to access the bottom of the unit.
3. Press-in locking clips at each end of
the front grill.
4. Lift bottom of grill and slide out
the grill from the top of the unit (figure 9).
5. Pull out the two filters individually
and discard them.
6. Install new HEPA filter in lower slot
with its white layer facing upwards.
7. Install new pre-filter in the remaining slot with its green side facing
upwards.
8. Replace grill. Slide upper end into grill slot and snap the bottom
into place so that it locks.
9. Reset the filter replacement timer by lightly pressing the FILTER
RESET button on the Service Panel
with a pin or similar object. The FILTER light will become green, and time will be reset to zero.
Restore the CX1000 to normal operation as follows:
1. Set the unit in its normal operating position.
2. Plug the power cord into the wall outlet.
figure 8
figure 9
figure 10
LIMITED LIFETIME WARRANTY
Each CX1000 Complete Air Purification System comes with a limited life­time warranty. This warranty provides for repair or replacement of any
defective parts or components for two years from the date of purchase at no charge for labor or materials. This warranty does not cover the expendable UV lamp, which must or the expendable filter cartridge media, which must two years or sooner, depending on environmental conditions. All warranty repair work must be performed either at the factory or by a factory certi­fied service center. Shipping cost to the factory or service center is the responsibility of the owner of the CX1000. To return product for warranty repair, the customer must first contact the factory for a Return Materials Authorization (RMA) number and a ship to address, as it may differ from the manufacturing location. For material repaired under warranty, ship­ping costs to the customer will be prepaid for the first two years only. This warranty is provided to the original purchaser of the CX1000, and may not be transferred, sold or bartered. This product is not warranted against freight damage, failure resulting from misuse, connection to incor­rect voltage, or acts of God such as fires, earthquakes, or floods.
be replaced on an annual basis (1-year),
be replaced every
1110
Continental Fan Manufacturing Inc.
203 Eggert Road
Buffalo, New York 14215
Tel: 800-779-4021 Fax: 716-842-0611
email: cfm@continentalfan.com
web: www.continentalfan.com
L4-CX1000-UG-0505
Loading...