CFM 167219, AXC100A, AXC100B, AXC125A, AXC125B Brochure & Specs

...
AXCAXC In-Line Duct FansIn-Line Duct Fans
AAXXCC IInn--LLiinnee DDuucctt FFaannss
Continental Fan’s AXC in-line centrifugal duct fans are designed for residential, commercial and industrial ventilation applications. The quiet and efficient backward-curved impeller is capable of developing significant pressure, and the in-line configuration simplifies installation, saving time and money!
Rigid duct tends to echo fan noise. To reduce sound levels, use flexible insulated duct (consult local codes before selecting duct type).
To minimize condensation, use insulated, flexible duct when venting bathrooms or other warm and moist areas.
DDeessiiggnn FFeeaattuurreess
Quiet, powerful, compact; the most user-friendly fan in the industry
Exclusive mounting brackets included for simple installation
106 cfm - 1400 cfm available, to fit duct sizes from 4”-14”
120V operation (also available in 220V; contact factory for details)
Speed controllable using solid state speed control (optional)
Fans are easily installed in flexible or rigid duct
Fans may be used to supply or exhaust air
Fans may be mounted in any position
Heavy gauge, drawn steel housing with baked epoxy finish inside and out
Suitable for light dust and fumes
Backward-curved fan impeller:
Operates at low sound levelsOvercomes high static pressureWill not stall or overload motor at low airflow
External rotor motor design results in superior motor cooling, durability
Permanently lubricated ball bearing motors for maintenance free operation
Automatic reset thermal overload protection
External junction box contains pre-wired capacitor, to simplify wiring
Fan and motor assembly is precision balanced for quiet and vibration-free operation
UL & CSA approvals
Five year warranty
2
AApppplliiccaattiioonnss
The versatility of the AXC fan is endless. The most common uses are bathroom exhaust, range hood exhaust and duct boosting.
BBaatthhrroooomm EExxhhaauusstt
AXC in-line duct fans are the strongest and quietest bathroom fans available today. These fans allow the exhaust of multiple vents or bathrooms with one fan. They are user friendly, easy to install, and can be located directly over a shower.
RRaannggee HHoooodd EExxhhaauusstt
AXC in-line duct fans can be used as a principle exhaust fan, or as a booster fan to improve the efficiency of an existing residential range hood. These fans can be variable speed controlled by using an independent speed controller, or by tying into an existing range hood controller. The heavy gauge housing, with epoxy coating inside and out, provides a rugged fan with superior corrosion protection.
DDuucctt BBoooossttiinngg
AXC in-line duct fans can solve many air moving problems. They are designed to boost airflow through long or complex duct runs, and provide ideal solutions for areas that are hard to heat or cool.
OOtthheerr aapppplliiccaattiioonnss iinncclluuddee::
• Residential kitchen exhaust
• Conference room exhaust
• Principal exhaust fan
• Cafeteria exhaust
• Computer rooms
• General ventilation
• Hot tub / sauna exhaust
• Health care facilities
• Hair & nail salons
• Warm air transfer
• Humidity and moisture removal
• Powered make-up air
• Spot cooling
• Equipment cooling
• HRV/ERV boosting
SSiimmpplliiffyy iitt wwiitthh aa KKiitt
At Continental Fan, we know that you have specific needs! That is why we offer a variety of kits for different ventilation applications! Not sure which kit is right for your application? Call one of our qualified technical support personnel; we are happy to help!
AAvvaaiillaabbllee AAcccceessssoorriieess
A full range of accessories is available to suit each custom application.
AAXXCC IInn--LLiinnee DDuucctt FFaannss
3
Flexible
Duct
Backdraft Dampers
Supply &
Exhaust Grilles
Mounting
Clamps
Pressure Switchs
Dehumidistats
Roof Caps Wall Caps
Digital Timers
Speed
Controls
* The sound pressure level dBA has been measured in accordance with the
international standard ISO 3744. It is the average free field value taken at a radius of 1 meter from the fan, fully ducted, and located above a reflecting plane.
At present, there is no standard for sone level testing of remote mounted fans. Sound levels can be affected by the type of duct used, size of duct, distance of the fan from the interior grille/diffuser, and other pertinent factors. Sound tests that do not consider these factors are irrelevant.
R
Note: AXC models 100A through 300B are UL and CSA listed products.
Note: AXC models 355A and 355B are CSA listed to both US and Canadian standards.
AXC-0910
Distributed By:
Continental Fan Manufacturing Inc.
203 Eggert Road Buffalo, NY 14215 Tel: 716-842-0670 Toll: 800-779-4021 Fax: 716-842-0611 www.continentalfan.com
Aeroflo Inc.
12–205 Matheson Blvd. East Mississauga, Ontario, Canada L4Z 3E3 Tel: 905-890-6192 Toll: 800-779-4021 Fax: 905-890-6193 www.aeroflo.com
MODEL WATTS AMPS RPM dBA*
CUBIC FEET PER MINUTE
0”SP1/
8”SP
1
/
4”SP
3
/
8”SP
1
/
2”SP
3
/
4”SP
1”SP 11/
4”SP
11/
2”SP
2”SP 3”SP
AXC100A 55 0.57 1750 44 106 99 93 87 80 68 55 39
AXC100B 85 0.69 2400 54 152 146 139 131 124 106 82 66 33
AXC125A 62 0.58 1650 36 159 127 100 82 68 34
AXC125B 85 0.70 2350 53 212 185 162 145 128 79 32
AXC150A 80 0.75 2500 54 247 225 202 178 161 132 92 50
AXC150B 72 0.73 2580 55 309 271 237 202 171 132 107 88 15
AXC200A 72 0.72 2550 56 418 397 366 339 306 233 174 110 56
AXC200B 160 1.52 2700 60 636 618 557 521 494 412 353 271 190 78
AXC250 250 1.94 2650 63 695 659 610 541 500 359 279 197 125 41
AXC300A 190 2.07 2650 68 865 824 765 736 677 553 459 365 283 124
AXC300B 345 2.78 2765 74 1198 1165 1052 981 945 796 615 453 363 178 65
AXC355A 334 2.88 1360 57 1325 1220 1105 985 860 688 550 400 238
AXC355B 830 7.81 2900 77 1400 1375 1360 1335 1285 1220 1135 1075 1000 880 675
MODEL
D
(in.)d(in.)a(in.)B(in.)WT(lbs)
AXC100A 9.5 3.9 1.0 8.3 6.5
AXC100B 9.5 3.9 1.0 8.3 6.5
AXC125A 9.5 4.8 1.0 8.3 6.5
AXC125B 9.5 4.8 1.0 8.3 6.5
AXC150A 9.5 5.8 1.0 8.3 6.5
AXC150B 13.2 5.8 1.0 9.1 11.0
AXC200A 13.2 7.8 1.0 9.1 11.0
AXC200B 13.2 7.8 1.0 9.1 11.0
AXC250 13.2 9.8 1.0 9.1 11.0
AXC300A 15.9 11.8 1.2 11.8 18.0
AXC300B 15.9 11.8 1.2 11.8 20.0
AXC355A 19.0 14.0 1.5 15.7 26.0
AXC355B 19.0 14.0 1.5 15.7 31.0
DDiimmeennssiioonnaall DDaattaaPPeerrffoorrmmaannccee DDaattaa
HHooww ddoo II kknnooww wwhhiicchh ffaann iiss bbeesstt ssuuiitteedd ffoorr mmyy aapppplliiccaattiioonn??
As previously summarized, there are numerous applications where ventilation is required. Whether it is for residential or commercial applications, it is imperative that the proper amount of airflow be calculated.
RReessiiddeennttiiaall One of our qualified technical support personnel would be happy to assist in selecting a fan for your residential ventilating needs. If you would like to inform yourself further, HVI, the Home Ventilating Institute provides ventilating guidelines for consumers.For more information, visit www.hvi.org.
CCoommmmeerrcciiaall For an application that is commercial or very specific in nature, you may want to enlist an HVAC contractor. For a list of contractors near you, consult the yellow pages.
R