CES Emergency Power Supply Operating Instructions Manual

Emergency Power Supply for
the OMEGA ACTIVE-System
Operating Instructions

Preface

Notes highlighted with this symbol contain additional information on the efficient use.
These Operating Instructions will help you using the Emergency Power Supply
as intended, safely, and advantageously.
Any person who
operates or disposes of
the Emergency Power Supply must have read and understood the entire contents of these Operating Instructions and other required user manuals, operating and assembly instructions.
Depending on the configuration of your locking system, you may require other user manuals, operating or fitting instructions for an overall understanding of the system. These Operating Instructions should always be kept within your reach.

Notes on the layout

In these Operating Instructions, a number of elements are highlighted with defined layout features so you can identify at a glance whether a passage contains
standard text,
a list, or
individual steps in a sequence of actions.
OMEGA ACTIVE Emergency power supply 2

Contents

Contents
Preface............................................................................ 2
Notes on the layout .......................................................... 2
For your safety ................................................................. 4
Basic safety instructions ......................................... 4
Notes on the handling of batteries .................................. 6
Explanation of the safety notes ...................................... 7
Intended use ............................................................... 7
Description ...................................................................... 8
Scope of delivery .............................................................. 9
Operation ...................................................................... 10
Inserting the batteries ................................................. 10
Performing the emergency opening ............................... 11
Updating the firmware ................................................ 15
Service and maintenance ................................................ 19
Trouble shooting ............................................................ 19
Disposal ........................................................................ 21
Technical data ................................................................ 22
Glossary ........................................................................ 23
Notes on the manufacturer's warranty .............................. 24
OMEGA ACTIVE Emergency power supply 3

For your safety

For your safety

Basic safety instructions

Observe all warnings and notes in these Operating Instructions when you
assemble, program, and use
components of the system.
To prevent danger to life and limb, the following safety instructions must be observed:

Danger to life

Make sure that the effects of your programming do not
expose any persons to any risk of injury or other hazards.
Satisfy yourself that your programming translates into the
desired function.
Make sure that all system components work perfectly.

Danger of explosion

Live parts of the system components may cause an
explosion. Do not use any components of the system in potentially explosive atmospheres.
The batteries of the Emergency Power Supply may get
overheated if charged and may explode. Never charge the batteries.

Danger of suffocation

Never allow children to play with packaging material and/or
plastic bags. Keep plastic film and other packaging material out of reach of children.
OMEGA ACTIVE Emergency power supply 4
For your safety

Danger of poisoning

Always keep the system components out of reach of children. There is a risk that children swallow small parts such as batteries or screws.

Danger of property damage

To prevent property damage, the following safety instructions should be observed:
Always have repairs performed by properly qualified
personnel.
Only use accessories and spare parts recommended by
CEStronics.
Do not drop the Emergency Power Supply on the floor, on
hard surfaces or on hard objects.
Protect the electronic parts of your system components
against water and other liquids.
The Emergency Power Supply contains highly sensitive
electronic parts that may be damaged or destroyed through static charges. Do not disassemble the Emergency Power Supply in rooms with built up static charge.

Danger through environmental conditions

Do not use the Emergency Power Supply in corrosive
atmospheres (chlorine, ammonia, lime water).
Only use the Emergency Power Supply in rooms in which the
humidity does not exceed 95%.
Do not use the Emergency Power Supply in rooms with a
high level of dust formation.
Do not use the Emergency Power Supply near sources of
heat.
OMEGA ACTIVE Emergency power supply 5
For your safety

Notes on the handling of batteries

Keep batteries out of reach of children. If a battery was
swallowed, consult a physician without delay.
Always insert new batteries. Never insert old and new
batteries at the same time.
Never mix the battery types. Always replace batteries by
batteries of the same or an equivalent type.
Before inserting the batteries, check that the terminals in the
device and at the batteries are clean. Clean them if necessary.
Observe the correct polarity (+/-) when inserting the
batteries.
Never attempt to recharge non-rechargeable batteries.
There is a risk of explosion!
Never short-circuit the batteries. Always store batteries at a cool, dry place. Direct heat may
damage the batteries. Do not expose any battery-powered devices to strong sources of heat.
Never throw any batteries into a fire. If you do not use your devices for a longer period, take out
the batteries.
Always remove leaked batteries immediately from the device.
Clean the terminals before inserting new batteries. There is a danger of acid burns through battery acid!
Remove flat batteries from the device.
OMEGA ACTIVE Emergency power supply 6
For your safety
ATTENTION
ATTENTION notes warn against possible property or environmental damage.

Explanation of the safety notes

These Operating Instructions include safety notes of the following types:

Intended use

The Emergency Power Supply is intended for the emergency opening of locking cylinders of the OMEGA ACTIVE system.
Any other use is considered to be improper and may result in property damage or even personal injury.
CEStronics GmbH does not accept any liability for any damage resulting from improper use.
OMEGA ACTIVE Emergency power supply 7

Description

Description
The Emergency Power Supply serves for the emergency opening of locking cylinders of the OMEGA ACTIVE system in case of flat batteries. The Emergency Power Supply also allows you to update the firmware of your locking cylinders.
The Emergency Power Supply has its own power supply comprised of four commercial rechargeable or non­rechargeable AA batteries to supply locking cylinders with power. This power supply is sufficient for about thirty emergency opening operations.
For the emergency opening, the outside knob of the locking cylinder is opened slightly and the Emergency Power Supply is connected with the interface. The green LEDs of the locking cylinder will light up green to signal the connection with the Emergency Power Supply.
To open the locking cylinder, you need your authorized locking medium. Hold your locking medium in front of the locking cylinder and rotate the outside knob by at least one notch.
Without an authorized locking medium, the locking cylinder cannot be opened.
With the "OMEGA ACTIVE Firmware-Update" software tool you can transmit firmware updates from the PC into the locking cylinder via the RS 232 interface.
OMEGA ACTIVE Emergency power supply 8

Scope of delivery

1
Emergency Power Supply
2
4 batteries, type AA
Scope of delivery
Before fitting and commissioning, please check the contents
of the package and the scope of delivery.
Check new devices for transport damage and inform your
dealer promptly if any damage is found.
OMEGA ACTIVE Emergency power supply 9

Operation

Operation

Inserting the batteries

The four supplied batteries must be inserted into the
Emergency Power Supply.
For this purpose, remove the cover of the battery
compartment on the rear of the Emergency Power Supply.
Insert the four batteries into the battery compartment. Make sure that you insert them with the correct polarity.
Push the cover again over the battery compartment.
The Emergency Power Supply is now operative.
OMEGA ACTIVE Emergency power supply 10
ATTENTION
After an emergency opening, the locking cylinder is no longer secured. In this case, you can no longer lock the locking cylinder from the outside. You can only lock the locking cylinder after you have inserted a new battery.
Always insert a new battery into the battery compartment
of the locking cylinder after each emergency opening.
ATTENTION
When the module is pulled out of the outside knob, the connection cable attached to the reader may be damaged.
Always pull the module out of the outside knob slowly and
carefully and for no more than ten centimetres.

Performing the emergency opening

Operation
OMEGA ACTIVE Emergency power supply 11
Operation
For an emergency opening of your locking cylinder, proceed as follows:
Release the two opposite screws on the outside knob with
the combination tool (three-square screwdriver).
These screws cannot be completely screwed out but will always be held in the outside knob.
OMEGA ACTIVE Emergency power supply 12
Operation
Pull the reader module out of the outside knob until you feel
the stop (1.).
Connect the Emergency Power Supply with the interface (2.)
at the reader module.
The LEDs in the reader module light up green to signal the connection with the Emergency Power Supply.
Wait a couple of seconds before you continue. Use your authorized locking medium to open the door. Rotate the outside knob of the locking cylinder by at least
one notch.
After you have opened the door, disconnect the connection
between the reader module and the Emergency Power Supply.
Insert a new battery into the locking cylinder. Observe the
notes in the operating instructions of your locking cylinder.
OMEGA ACTIVE Emergency power supply 13
Operation
Push the reader module back into the sleeve of the outside
knob.
To fasten the reader module, hand-tighten the two opposite
screws with the combination tool (three-square screwdriver).
This completes the emergency opening.
OMEGA ACTIVE Emergency power supply 14
Operation
ATTENTION
If you separate the power supply during the update process, the update will not be transmitted and the process must be started anew.
Make sure that the connection between the locking cylinder
and the Emergency Power Supply is not interrupted.
Satisfy yourself that the batteries in the Emergency Power
Supply still have sufficient capacity.
ATTENTION
By a firmware update, all authorizations for the locking cylinder will be deleted.
After the successful firmware update, you must reprogram
all authorizations for the locking cylinder concerned.

Updating the firmware

To transmit new firmware updates, you require a PC (option) with a free COM port.
Firmware updates are transmitted to the locking cylinder with the "OMEGA ACTIVE Firmware-Update" software.
OMEGA ACTIVE Emergency power supply 15
Operation
To transmit firmware updates with "OMEGA ACTIVE Firmware­Update" into the locking cylinder, proceed as follows:
Connect the Emergency Power Supply with a free COM port of your PC.
Start the "OMEGA ACTIVE Firmware-Update" software on
your PC, by selecting:
- Start > Programs > OMEGA/OMEGA Active Firmware
Update
Wait until the following message appears.
Select the device for which you want to perform the update. Select the COM port. Perform an authorization with your SYSTEM-MASTER. Connect the locking cylinder with the Emergency Power
Supply.
Click on the "Update" button.
OMEGA ACTIVE Emergency power supply 16
Operation
Push the "Software Update" button on your Emergency
Power Supply.
The update starts and the PC monitor shows the progress of the updating process.
After the update has been transmitted successfully, the following message appears:
Separate the connection between the locking cylinder and
the Emergency Power Supply.
Separate the connection between the Emergency Power
Supply and your PC.
OMEGA ACTIVE Emergency power supply 17
Operation
Close the "OMEGA ACTIVE Firmware-Update" software. Push the reader module of the locking cylinder back into the
sleeve of the outside knob.
Hand-tighten the two opposite screws with the combination
tool (three-square screwdriver).
This completes the firmware update.
OMEGA ACTIVE Emergency power supply 18

Service and maintenance

Symptom
Possible cause and remedy
Emergency opening is not possible.
The batteries of your Emergency Power Supply are flat.
Check the batteries of your Emergency
Power Supply.
Your locking medium is not authorized for the locking cylinder concerned.
Use the authorized locking medium for
the locking cylinder concerned.
The connection between the Emergency Power Supply and the locking cylinder is faulty.
Make sure that the connection has
been properly established.
Firmware update is not possible.
The "OMEGA ACTIVE Firmware-Update" software is not configured correctly.
Ensure proper functioning of the
software.
Service and maintenance
Have the Emergency Power Supply serviced and its perfect
functioning verified every six months by CEStronics or a CEStronics partner.
Replace the batteries in line with a defined maintenance
schedule for the Emergency Power Supply.
Make sure you have replacement batteries ready in good
time.

Trouble shooting

OMEGA ACTIVE Emergency power supply 19
Trouble shooting
Symptom
Possible cause and remedy
Firmware update is not possible.
The SYSTEM-MASTER is not authorized for the locking cylinder concerned.
Use the SYSTEM-MASTER authorized
for the locking cylinder concerned.
The batteries of the Emergency Power Supply are flat.
Check the batteries of the Emergency
Power Supply.
Your COM port does not work properly.
Verify the functioning of your COM
port.
If the trouble still cannot be eliminated, please contact your CEStronics partner.
OMEGA ACTIVE Emergency power supply 20

Disposal

Neither the Emergency Power Supply nor any of its components may be discarded with the normal household waste. Ask your local authorities about recycling and/or proper disposal in line with environmental regulations.
Our packaging is made of environmentally friendly, reusable materials.
These are external packaging and inserts made of cardboard, inserts and protective film made of polypropylene (PE).
Please dispose of the packaging in an environmentally responsible manner through separate waste streams.
Disposal
OMEGA ACTIVE Emergency power supply 21
Dimensions:
Length: approx.130 mm Width: approx. 70 mm Height: approx. 25 mm
Power supply:
4  1.5 V AA type batteries
Ports:
- 1  plug for connection with
the locking cylinder
- 1  RS 232 for connection
with COM port (SUB-D, 9-pole)
Length of connection cable:
Approx. 40 cm

Technical data

Technical data
OMEGA ACTIVE Emergency power supply 22

Glossary

Emergency opening
Opening of a locking cylinder in case of a flat battery. The required power is provided by the Emergency Power Supply.
Firmware
The "operating system" of your locking cylinder. To benefit from further developments in the firmware, an occasional update of the firmware is recommended.
SYSTEM-MASTER
The optional SYSTEM-MASTER is used to define the allocation to a locking system. The SYSTEM-MASTER grants all highest-level authorizations.
Glossary
OMEGA ACTIVE Emergency power supply 23

Notes on the manufacturer's warranty

Notes on the manufacturer's warranty
The manufacturer's warranty does not cover:
damage to outer mechanical parts and damage resulting
from normal wear and tear
damage as a consequence of external events or influence damage as a consequence of improper operation damage as a consequence of excess voltage damage as a consequence of fire, water or smoke batteries.
OMEGA ACTIVE Emergency power supply 24
The information and data contained in this document are subject to change without notice. Without the express written permission by CEStronics, no part of this document may be copied or transmitted for any purpose. © 2008 CEStronics, Velbert
November 2008
BRO 2214-001, V 1.2, 09/2012
CEStronics GmbH Friedrichstr. 243 42551 Velbert, GERMANY Phone: +49 2051-204-0 Fax: +49 2051-204-229 www.ces.eu