DC to AC Power Inverters
OWNERS MANUAL for Model:
12Z8NV 24Z8NV 48Z8NV
OWNERS MANUAL
FOR AIRPAX DIMENSIONS
INVERTERS
Model 12Z8NV Model 24Z8NV Model 48Z8NV
Table of Contents
Page
1. General . . . . . . . . . . . . . . 2
2. Description . . . . . . . . . . . 2
3. Installation . . . . . . . . . . . 3
4. Start Up/Operation. . . . . . 4
5. Troubleshooting. . . . . . . . 4
6. Installation Figure . . . . . . 5
7. Warranty . . . . . . . . . . . . 6
1. GENERAL
1.01 Dimensions inverters have been designed
and manufactured for many user applications and long life. They utilize patented construction methods and high technology electronic parts and circuitry.
1.02
voltages, to avoid risk of harm or fire the unit must be properly installed. There are no user serviceable parts inside, do not remove the cover.
CAUTION:
a zero clearance enclosure.
CAUTION:
correct polarity is not observed when installing the DC input cables.
CAUTION:
external AC power source is applied to the inverter’s AC output or its hardwire output.
CAUTION:
and a capacitor that may produce a spark. Do not mount in a confined battery or gas compartment.
CAUTION:
batteries is dangerous. Batteries generate explo-
CAUTION:
The inverter should not be installed in
Damage to the inverter will occur if
Damage to the inverter will occur if an
The inverter contains a circuit breaker
Working in the vicinity of lead-acid
Inverters produce hazardous
sive gases during operation. There is a risk of acid exposure. There is also a risk of high current discharge from shorting the battery that can cause fire and explosion.
CAUTION:
fuse are turned
2. DESCRIPTION
2.01 The inverter converts 12VDC, 24VDC or
48VDC depending on inverter model to a 120VAC, 60 HZ, having a pure sine wave form signal output.
2.02 The inverter has a controlled frequency
at 60 HZ
2.03
against output short circuit, output overload and high temperature conditions.
2.04 The inverter is designed to operate any 120 VAC, 60 HZ, single phase appliance, equipment or tool within its power ratings.
2.05 The inverter has a ventless cover to protect the inside electronics from the elements and is designed to be used on scissor lift applica­tions.
2.06 The inverter is GFCI protected but does not have standard GFCI outlets. The 120VAC, 60Hz output is supplied by a female receptacle cord attached to the unit.
2.07 The inverter does not have a "On"/"Off" switch. The unit must be controlled by a remote switch, a violet wire is attached to the unit for this purpose.
Inverter Input Output___
Model (VDC) (ADC) (VAC) (Watts) 12Z8NV 12.6 Up to 80 120 800 24Z8NV 25.2 Up to 40 120 800 48Z8NV 50.4 Up to 20 120 800
Be sure the inverter's circuit breaker or
"OFF" during installation.
+ 0.6Hz.
The inverter has internal protection
Inverter Ratings