irpax Dimensions, Inc.
4467 White Bear Parkway (651) 653-7000
St. Paul, MN 55110-7626 Fax (651) 653-7600
OWNERS MANUAL JANUARY 2007
ISO 9001:2000 Certified Company
121718B
Airpax Dimensions, Inc.
DC to AC Power Inverters
OWNERS MANUAL for Model:
12Z8NV
24Z8NV
48Z8NV
Form 121718
OWNERS MANUAL
FOR AIRPAX DIMENSIONS
INVERTERS
Model 12Z8NV
Model 24Z8NV
Model 48Z8NV
Table of Contents
Page
1. General . . . . . . . . . . . . . . 2
2. Description . . . . . . . . . . . 2
3. Installation . . . . . . . . . . . 3
4. Start Up/Operation. . . . . . 4
5. Troubleshooting. . . . . . . . 4
6. Installation Figure . . . . . . 5
7. Warranty . . . . . . . . . . . . 6
1. GENERAL
1.01 Dimensions inverters have been designed
and manufactured for many user applications and
long life. They utilize patented construction
methods and high technology electronic parts
and circuitry.
1.02
voltages, to avoid risk of harm or fire the unit
must be properly installed. There are no user
serviceable parts inside, do not remove the cover.
CAUTION:
a zero clearance enclosure.
CAUTION:
correct polarity is not observed when installing
the DC input cables.
CAUTION:
external AC power source is applied to the inverter’s
AC output or its hardwire output.
CAUTION:
and a capacitor that may produce a spark. Do not
mount in a confined battery or gas compartment.
CAUTION:
batteries is dangerous. Batteries generate explo-
CAUTION:
The inverter should not be installed in
Damage to the inverter will occur if
Damage to the inverter will occur if an
The inverter contains a circuit breaker
Working in the vicinity of lead-acid
Inverters produce hazardous
sive gases during operation. There is a risk of acid
exposure. There is also a risk of high current
discharge from shorting the battery that can cause
fire and explosion.
CAUTION:
fuse are turned
2. DESCRIPTION
2.01 The inverter converts 12VDC, 24VDC or
48VDC depending on inverter model to a 120VAC,
60 HZ, having a pure sine wave form signal output.
2.02 The inverter has a controlled frequency
at 60 HZ
2.03
against output short circuit, output overload and
high temperature conditions.
2.04 The inverter is designed to operate
any 120 VAC, 60 HZ, single phase appliance,
equipment or tool within its power ratings.
2.05 The inverter has a ventless cover to
protect the inside electronics from the elements
and is designed to be used on scissor lift applicaÂtions.
2.06 The inverter is GFCI protected but does
not have standard GFCI outlets. The 120VAC, 60Hz
output is supplied by a female receptacle cord
attached to the unit.
2.07 The inverter does not have a "On"/"Off"
switch. The unit must be controlled by a remote
switch, a violet wire is attached to the unit for this
purpose.
Inverter Input Output___
Model (VDC) (ADC) (VAC) (Watts)
12Z8NV 12.6 Up to 80 120 800
24Z8NV 25.2 Up to 40 120 800
48Z8NV 50.4 Up to 20 120 800
Be sure the inverter's circuit breaker or
"OFF" during installation.
+ 0.6Hz.
The inverter has internal protection
Inverter Ratings
Page 2