CertaUPS C60-800, C60-1500, C60-100, C60-2000 User Manual

Important Safety Warnings
This manual contains instructions and warnings that should be followed during the
installation, operating and storage of the UPS system. Please keep this manual for
further reference.
CAUTION! To prevent the risk of fire or electric shock, install in a temperature and humidity
controlled indoor area free of conductive contaminants. (See the specifications for the acceptable temperature and humidity range) CAUTION! To reduce the risk of overheating the UPS, do not cover the UPS' cooling vents and avoid exposing the unit to direct sunlight or installing the unit near heat emitting appliances such as radiators.
CAUTION! Do not plug the UPS input into its own output. CAUTION! Do not allow liquids or any foreign object to enter the UPS. Do not place beverages
or any other liquid-containing vessels on or near the unit. CAUTION! In the event of an emergency, press the OFF button and disconnect the power cord from the AC power supply to completely disable the UPS. CAUTION! The UPS installation must be correctly ground in order to reduce leakage current below 3.5mA. Attention The UPS output is supplied by two sources. When the UPS is disconnected from mains power, hazardous voltage may still be present from the internal battery. The battery should be disconnected when maintenance or service work inside the UPS is necessary. CAUTION! Servicing of batteries should be performed or supervised by qualified personnel only.
CAUTION! When replacing the batteries, use the same number and type of batteries. CAUTION! Dispose of batteries in the correct manner and in line with local laws and
regulations. Never dispose of batteries in a fire. Do not attempt open the battery. Released electrolyte is harmful to the skin and eyes.
CAUTION! Unplug the UPS prior to cleaning and do not use liquid or spray detergent. CAUTION! A battery can present a risk of electric shock and short circuit.
CAUTION! This is a category C2 UPS product. In a residential environment, this product may
cause radio interference, in which case the user many be required to take additional measures.
Designed and Engineered by:
Power Control Ltd
www.certaups.com
Specifications
MODEL
C60-800
C60-1000
C60-1500
C60-2000
CAPACITY
800VA/480W
1000VA/600W
1500VA/900W
2000VA/1200W
INPUT
Input Voltage
220/230/240VAC
Voltage Range
162-290VAC
OUTPUT
Voltage Regulation
+/-10%
Transfer Time
Typical 2-6ms, 10ms max.
Waveform
Simulated Sinewave
BATTERY
Type & Number
12V/9Ah x 1
12V/7Ah x 2
12V/9Ah x 2
12V/9Ah x 2
Charging Time
4-6 hours recover to 90% capacity
PHYSICAL
Dimension (WxDxH) mm
100 x 287 x 142
146 x 350 x 160
146 x 397 x 205
Net Weight (KG)
4.9
8.0
11.1
11.5
C60 Uninterruptible Power Supply
User Manual
Installation & Operation
Initial Set-up
After unpacking the unit, please avoid placing the unit in direct sun light, excessive heat,
excessive humidity or in contact with fluids of any type. Please allow 20cm space around the
unit.
     Connect Mains Power
Plug the UPS into an electrical outlet that does not share a circuit with any other heavy
electrical load. Please allow the UPS to charge at least 6 hours prior to use.
  Connect Equipment
Connect critical equipment to the battery backup outlets, these are supported automatically
when a mains failure occurs. Connect other equipment that needs only surge suppression to
the surge protected outlets. Power is not supplied to these outlets when the unit is switched off.
Therefore, please be sure to switch on the unit.
NOTE: Please DO NOT connect scanners or printers to the battery backup outlets.
 Connect Modem/Phone/Network for Surge Protection
Connect a single modem/phone line into surge-protected “IN” outlet on the back panel of the
UPS unit. Connect from “OUT” outlet to the computer with another phone line cable.
Connect Communication Port
To allow for unattended UPS shutdown/start-up and status monitoring, connect the communication cable one end to the USB port and the other to the communication port of your PC. With the monitoring software installed, you can schedule UPS shutdown/start-up and monitor UPS status through PC.
Software Installation
1) Please download the monitoring and shutdown software from the website
www.certaups.com/downloads to download ViewPower software.
2) When your computer restarts, the monitoring software will appear as an orange plug icon
located in the system tray, near the clock.
Power On/Off UPS
Press power switch on the front panel of the UPS to turn on the UPS. Press switch again to turn
off the UPS.
Front Panel & Back Panel
LCD panel
Power switch
C60-800 C60-1000 C60-1500/2000
Troubleshooting
Problem
Possible Cause
Solutions
Nothing displays on the front panel.
Low battery
Charge the UPS at least 6 hours.
Battery fault
Replace the battery with the same type of battery.
The UPS is not turned on
Press the power switch again to turn on the UPS.
Alarm continuously sounds when the mains is normal.
The UPS is overloaded
Remove some load first. Before reconnecting equipment, please verify that the load matches the UPS capability specified in the specs.
When power fails, the back-up time is very short.
The UPS is overloaded
Remove some critical load.
Battery voltage is too low
Charge the UPS at least 6 hours.
Battery defect. It might be due to high temperature operation environment, or improper operation to battery
Replace the battery with the same type of battery. The mains is normal but UPS is on battery mode.
Power cord is loose
Reconnect the power cord properly.
LCD Panel:
Input voltage Load level indicator, flashing Output voltage indicates overload AC mode indicator Battery capacity indicator, flashing Battery mode indicator indicates low battery
Battery backup outlets Surge protected outlets AC input USB communication port Modem/Phone Line
/Network surge
protection