Important Safety Warnings
This manual contains instructions and warnings that should be followed during the
installation, operating and storage of the UPS system. Please keep this manual for
further reference.
CAUTION! To prevent the risk of fire or electric shock, install in a temperature and humidity
controlled indoor area free of conductive contaminants. (See the specifications for the
acceptable temperature and humidity range)
CAUTION! To reduce the risk of overheating the UPS, do not cover the UPS' cooling vents and
avoid exposing the unit to direct sunlight or installing the unit near heat emitting appliances
such as radiators.
CAUTION! Do not plug the UPS input into its own output.
CAUTION! Do not allow liquids or any foreign object to enter the UPS. Do not place beverages
or any other liquid-containing vessels on or near the unit.
CAUTION! In the event of an emergency, press the OFF button and disconnect the power
cord from the AC power supply to completely disable the UPS.
CAUTION! The UPS installation must be correctly ground in order to reduce leakage current
below 3.5mA.
Attention The UPS output is supplied by two sources. When the UPS is disconnected from
mains power, hazardous voltage may still be present from the internal battery. The battery
should be disconnected when maintenance or service work inside the UPS is necessary.
CAUTION! Servicing of batteries should be performed or supervised by qualified personnel
only.
CAUTION! When replacing the batteries, use the same number and type of batteries.
CAUTION! Dispose of batteries in the correct manner and in line with local laws and
regulations. Never dispose of batteries in a fire. Do not attempt open the battery. Released
electrolyte is harmful to the skin and eyes.
CAUTION! Unplug the UPS prior to cleaning and do not use liquid or spray detergent.
CAUTION! A battery can present a risk of electric shock and short circuit.
CAUTION! This is a category C2 UPS product. In a residential environment, this product may
cause radio interference, in which case the user many be required to take additional measures.
Designed and Engineered by:
Power Control Ltd
www.certaups.com
4-6 hours recover to 90% capacity
C60 Uninterruptible Power Supply
User Manual

Initial Set-up
After unpacking the unit, please avoid placing the unit in direct sun light, excessive heat,
excessive humidity or in contact with fluids of any type. Please allow 20cm space around the
unit.
Connect Mains Power
Plug the UPS into an electrical outlet that does not share a circuit with any other heavy
electrical load. Please allow the UPS to charge at least 6 hours prior to use.
Connect Equipment
Connect critical equipment to the battery backup outlets, these are supported automatically
when a mains failure occurs. Connect other equipment that needs only surge suppression to
the surge protected outlets. Power is not supplied to these outlets when the unit is switched off.
Therefore, please be sure to switch on the unit.
NOTE: Please DO NOT connect scanners or printers to the battery backup outlets.
Connect Modem/Phone/Network for Surge Protection
Connect a single modem/phone line into surge-protected “IN” outlet on the back panel of the
UPS unit. Connect from “OUT” outlet to the computer with another phone line cable.
Connect Communication Port
To allow for unattended UPS shutdown/start-up and status monitoring, connect the
communication cable one end to the USB port and the other to the communication port of your
PC. With the monitoring software installed, you can schedule UPS shutdown/start-up and
monitor UPS status through PC.
Software Installation
1) Please download the monitoring and shutdown software from the website
www.certaups.com/downloads to download ViewPower software.
2) When your computer restarts, the monitoring software will appear as an orange plug icon
located in the system tray, near the clock.
Power On/Off UPS
Press power switch on the front panel of the UPS to turn on the UPS. Press switch again to turn
off the UPS.
LCD panel
Power switch
C60-800 C60-1000 C60-1500/2000
Nothing displays on the
front panel.
Charge the UPS at least 6 hours.
Replace the battery with the same
type of battery.
Press the power switch again to turn
on the UPS.
Alarm continuously
sounds when the
mains is normal.
Remove some load first. Before
reconnecting equipment, please
verify that the load matches the UPS
capability specified in the specs.
When power fails, the
back-up time is very
short.
Remove some critical load.
Battery voltage is too low
Charge the UPS at least 6 hours.
Battery defect. It might be due
to high temperature operation
environment, or improper
operation to battery
Replace the battery with the same
type of battery.
The mains is normal but
UPS is on battery mode.
Reconnect the power cord properly.
LCD Panel:
Input voltage Load level indicator, flashing
Output voltage indicates overload
AC mode indicator Battery capacity indicator, flashing
Battery mode indicator indicates low battery
Battery backup outlets
Surge protected outlets
AC input
USB communication port
Modem/Phone Line
/Network surge
protection