Important Safety Warnings
This manual contains instructions and warnings that should be followed during the
installation, operating and storage of the UPS system. Please keep this manual for
further reference.
CAUTION! To prevent the risk of fire or electric shock, install in a temperature and humidity
controlled indoor area free of conductive contaminants. (See the specifications for the
acceptable temperature and humidity range)
CAUTION! To reduce the risk of overheating the UPS, do not cover the UPS' cooling vents and
avoid exposing the unit to direct sunlight or installing the unit near heat emitting appliances
such as radiators.
CAUTION! Do not plug the UPS input into its own output.
CAUTION! Do not allow liquids or any foreign object to enter the UPS. Do not place beverages
or any other liquid-containing vessels on or near the unit.
CAUTION! In the event of an emergency, press the OFF button and disconnect the power
cord from the AC power supply to completely disable the UPS.
CAUTION! The UPS installation must be correctly grounded in order to reduce leakage current
below 3.5mA.
Attention The UPS output is supplied by two sources. When the UPS is disconnected from
mains power, hazardous voltages may still be present from the internal battery. The battery
should be disconnected when maintenance or service work inside the UPS is necessary.
CAUTION! Servicing of batteries should be undertaken or supervised by qualified personnel
only.
CAUTION! When replacing the batteries, use the same number and type of batteries.
CAUTION! Dispose of batteries in the correct manner and in line with local laws and
regulations. Never dispose of batteries in a fire. Do not attempt to open the battery. Released
electrolyte is harmful to the skin and eyes.
CAUTION! Unplug the UPS prior to cleaning and do not use liquid or spray detergent.
CAUTION! A battery can present a risk of electric shock and short circuit.
CAUTION! This is a category C2 UPS product. In a residential environment, this product may
cause radio interference, in which case the user many be required to take additional measures.
Designed and Engineered by:
CertaUPS
www.certaups.com
MODEL C200-1000 C200-1500 C200-2000
CAPACITY 1000VA/700W 1500VA/1050W 2000VA/1400W
INPUT
Input Voltage 110/120VAC or 220/230/240VAC
Voltage Range 81-145VAC / 162-290VAC
OUTPUT
Voltage Regulation +/-10%
Transfer Time Typical 2-6ms, 10ms max.
Waveform Pure Sinewave
BATTERY
Type & Number 12V/7Ah x 2 12V/9Ah x 2 12V/10Ah x 2
Charging Time 4-6 hours recover to 90% capacity
PHYSICAL
Dimension (DxWxH) mm 350 x 146 x 160 397 x 146 x 205
Net Weight (kgs) 8.96 12.18 13.7
C200 Uninterruptible Power Supply
User Manual

Installation & Operation
Initial Set-up
After unpacking the unit, please avoid placing
the unit in direct sun light, excessive heat,
excessive humidity or in contact with fluids
of any type. Please allow 20cm space around
the unit for unrestricted airflow.
Connect Mains Power
Plug the UPS into an electrical outlet that does not share a circuit with any other heavy
electrical loads. Please charge the UPS for at least 6 hours prior to use.
Connect Equipment
Connect critical equipment to the battery backup outlets, these are supported automatically
when a mains failure occurs. Connect equipment that only needs surge suppression to the
surge protected outlets. Power is not supplied to these outlets when the unit is switched off.
Therefore, please be sure to switch the unit on.
NOTE: Please DO NOT connect scanners or printers to the battery backup outlets.
Connect Modem/Phone/Network for Surge Protection
Connect a single modem/phone line into the surge-protected “IN” outlet on the back panel of
the UPS unit. Connect the computer to the "OUT" outlet with another ethernet cable.
Connect Communication Port
To allow for unattended UPS shutdown/start-up and status monitoring, connect the
communication cable between the UPS and a USB port on your PC. With the monitoring
software installed, you can schedule UPS shutdown/start-up and monitor UPS status through
the PC.
Software Installation
1) Please download the monitoring and shutdown software from the website
www.certaups.com/downloads to download ViewPower software.
2) When your computer restarts, the monitoring software will appear as an orange plug icon
located in the system tray, near the clock.
Power On/Off UPS
Press the power switch on the front panel of the UPS to turn on the UPS. Press the switch again
to turn off the UPS.
LCD panel
Power switch
C200-1000 C200-1500/2000
Problem Possible Cause Solutions
Nothing displays on the
front panel.
Low battery. Charge the UPS for at least 6 hours.
Battery fault. Replace the battery with the same ty
battery.
The UPS is not turned on. Press the power switch again to turn on
the UPS.
Alarm continuously
sounds when the
mains is normal.
The UPS is overloaded. Remove some of the protected load first.
Before reconnecting equipment, please
verify that the load matches the UPS
capability specified in the Spec.
When power fails, back-up
time is shorten.
The UPS is overloaded. Remove some of the protected load.
Battery voltage is too low. Charge the UPS at least 6 hours.
Battery defect. It might be due to
high temperature operation
environment, or improper
operation to battery.
Replace the battery with the same type of
battery.
The mains is normal but
UPS is on battery mode.
Power cord is loose. Reconnect the power cord properly.
LCD Panel:
Input voltage
Load level indicator, flashing
Output voltage indicates overload
AC mode indicator
Battery capacity indicator, flashing
Battery mode indicator Indicates low battery
Battery backup receptacles
Surge protected receptacles
AC input
USB communication port
Modem/Phone Line/Network
surge protection