Century IM998 User Manual

Page 1
INVERTER ARC 120
RETURN TO MAIN MENU
IM998
August, 2009
For use with machines having Code Numbers:
Safety Depends on You
Century® arc welding and cutting equipment is designed and built with safety in mind. However, your overall safety can be increased by proper installation ... and thought­ful operatio n on your part. DO
NO T IN STAL L, OPERATE O R REPAIR THIS EQ U IPMENT WITHOUT READING THIS MANUAL AND THE SAFETY PRECAUTIONS C O N TA I N E D THROUGHOUT. And, most
importantly, think before you act and be careful.
11565
OPERATOR’S MANUAL
Copyright © Lincoln Global Inc.
Century Equipment
2345 Murphy Blvd. Gainesville, GA30504 TEL: 866-236-0044
Page 2
i
SAFETY
WARNING
CALIFORNIA PROPOSITION 65 WARNINGS
Diesel engine exhaust and some of its constituents are known to the State of California to cause can­cer, birth defects, and other reproductive harm.
The Above For Diesel Engines
ARC WELDING CAN BE HAZARDOUS. PROTECT YOURSELF AND OTHERS FROM POSSIBLE SERIOUS INJURY OR DEATH. KEEP CHILDREN AWAY. PACEMAKER WEARERS SHOULD CONSULT WITH THEIR DOCTOR BEFORE OPERATING.
Read and understand the following safety highlights. For additional safety information, it is strongly recommended that you purchase a copy of “Safety in Welding & Cutting - ANSI Standard Z49.1” from the American Welding Society, P.O. Box 351040, Miami, Florida 33135 or CSA Standard W117.2-1974. A Free copy of “Arc Welding Safety” booklet E205 is available from the Lincoln Electric Company, 22801 St. Clair Avenue, Cleveland, Ohio 44117-1199.
BE SURE THAT ALL INSTALLATION, OPERATION, MAINTENANCE AND REPAIR PROCEDURES ARE PERFORMED ONLY BY QUALIFIED INDIVIDUALS.
The engine exhaust from this product contains chemicals known to the State of California to cause cancer, birth defects, or other reproductive harm.
The Above For Gasoline Engines
i
FOR ENGINE powered equipment.
1.a. Turn the engine off before troubleshooting and maintenance work unless the maintenance work requires it to be running.
____________________________________________________
1.b.Operate engines in open, well-ventilated areas or vent the engine exhaust fumes outdoors.
____________________________________________________
1.c. Do not add the fuel near an open flame welding arc or when the engine is running. Stop the engine and allow it to cool before refueling to prevent spilled fuel from vaporiz­ing on contact with hot engine parts and igniting. Do not spill fuel when filling tank. If fuel is spilled, wipe it up and do not start engine until fumes have been eliminated.
____________________________________________________
1.d. Keep all equipment safety guards, covers and devices in position and in good repair.Keep hands, hair, clothing and tools away from V-belts, gears, fans and all other moving parts when starting, operating or repairing equipment.
____________________________________________________
1.e. In some cases it may be necessary to remove safety
guards to perform required maintenance. Remove guards only when necessary and replace them when the maintenance requiring their removal is complete. Always use the greatest care when working near moving parts.
___________________________________________________
1.f. Do not put your hands near the engine fan. Do not attempt to override the governor or idler by pushing on the throttle control rods while the engine is running.
1.h. To avoid scalding, do not remove the radiator pressure cap when the engine is hot.
ELECTRIC AND MAGNETIC FIELDS may be dangerous
2.a. Electric current flowing through any conductor causes localized Electric and Magnetic Fields (EMF). Welding current creates EMF fields around welding cables and welding machines
2.b. EMF fields may interfere with some pacemakers, and welders having a pacemaker should consult their physician before welding.
2.c. Exposure to EMF fields in welding may have other health effects which are now not known.
2.d. All welders should use the following procedures in order to minimize exposure to EMF fields from the welding circuit:
2.d.1.
Route the electrode and work cables together - Secure them with tape when possible.
2.d.2. Never coil the electrode lead around your body.
2.d.3. Do not place your body between the electrode and
work cables. If the electrode cable is on your right side, the work cable should also be on your right side.
___________________________________________________
1.g. To prevent accidentally starting gasoline engines while turning the engine or welding generator during maintenance work, disconnect the spark plug wires, distributor cap or magneto wire as appropriate.
2.d.4. Connect the work cable to the workpiece as close as possible to the area being welded.
2.d.5. Do not work next to welding power source.
Mar ‘95
Page 3
ii
SAFETY
ii
ELECT RIC SHOCK can kill.
3.a. The electrode and work (or ground) circuits are electrically “hot” when the welder is on. Do not touch these “hot” parts with your bare skin o r we t cloth ing. Wea r dry, hole-free
gloves to insulate hands.
3.b. Insulate yourself from work and ground using dry insulation. Make certain the insulation is large enough to cover your full area of physical contact with work and ground.
In addition to the normal safety precautions, if welding mu s t be pe rfor m e d un d er electr i c a l ly haza r d o us con ditions (in damp locatio ns or while wearing wet clothing; on metal structures such as floors, gratings or scaffolds; when in cramped positions such as sitting, kneeling or lying, if there is a high risk of unavoidable or accidental contact with the workpiece or ground) use the following equipment:
• Semiautomatic DC Constant Voltage (Wire) Welder.
• DC Manual (Stick) Welder.
• AC Welder with Reduced Voltage Control.
3.c. In semiautomatic or automatic wire welding, the electrode, electrode ree l, weldi ng hea d, noz zle or semia utom at ic welding gun are also electrically “hot”.
3.d. Always be sure the work cable makes a good electrical connection with the metal being welded. The connection should be as close as possible to the area being welded.
3.e. Ground the work or metal to be welded to a good electrical (earth) ground.
3.f.
Maintain the electrode holder, work clamp, welding cable and welding machine in good, safe operating condition. Replace damaged insulation.
3.g. Never dip the electrode in water for cooling.
3.h. Never si mul tan eous ly touc h elec tric ally “h ot” par ts of electrode holders connected to two welders because voltage between the two can be the total of the open circuit voltage of both welders.
3.i. When working above floor level, use a safety belt to protect yourself from a fall should you get a shock.
3.j. Also see Items 6.c. and 8.
ARC RAYS can burn.
4.a. Use a shield with the proper filter and cover plates to protect your eyes from sparks and the rays of the arc when welding or observing open arc welding. Headshield and filter lens should conform to ANSI Z87. I standards.
4.b. Use suitable clothing made from durable flame-resistant material to protect your skin and that of your helpers from the arc rays.
4.c. Protect other nearby personnel with suitable, non-flammable screening and/or warn them not to watch the arc nor expose themselves to the arc rays or to hot spatter or metal.
FUMES AND GASES can be dangerous.
5.a. Welding may produce fu mes and gase s hazardous to health. Avoid breathing these fumes and gas es. Wh en we lding, ke ep your head out of the fume. Use enough ventilation and/or exhaust at the arc to keep
fumes and gases away from the breathing zone. When
we l d i ng with e l e c t rode s w h i ch re q u i re spe c i a l ve n t ilatio n such as stainl e s s or hard fa cing (see in s tru c tion s on con t aine r or MS D S) or on le a d or cadmium plated steel and o ther m et als or coat in gs which produce highly toxic fumes, keep exposure as low as possible and within applicable OSHA PEL and ACGIH TLV limits using local exhaust or mechanical ven­tilation. In confined spaces or in some circumstances, outdoors, a respirator may be required. Additional pre­cautions are also required when welding on galvanized steel.
5. b. The operation of welding fume control equipment is affected by various factors including proper use and positioning of the equipment, maintenance of the equipment and the specific welding procedure and application involved. Worker expo­sure level should be checked upon installation and periodi­cally thereafter to be certain it is within applicable OSHA PEL and ACGIH TLV limits.
5.c.
Do not weld in locations near chlorinated hydrocarbon coming from degreasing, cleaning or spraying operations. The heat and rays of the arc can react with solvent vapors form phosgene, a highly toxic gas, and other irritating prod­ucts.
5.d. Shielding gases used for arc welding can displace air and
ca use inj ury or d eat h. Always us e en oug h ve nti lat ion , especially in confined areas, to insure breathing air is safe.
vapors
to
5.e. Read and understand the manufacturer’s instructions for this equipment and the consumables to be used, including the ma t e r i a l sa fet y da t a she e t (MSDS ) and f ollow your employer’s safety practices. MSDS forms are available from yo u r we l d ing d i s t r i buto r or fro m th e ma n u factu r e r.
5.f. Also see item 1.b.
Jan ‘09
Page 4
iii
SAFETY
iii
WELDING and CUTTING SPARKS can cause fire or explosion.
6.a.
Remove fire hazards from the welding area. If this is not possible, cover them to prevent
Re m e m ber th a t w elding sp a r k s and ho t materials from welding can easily go through small cracks an d o p enin g s to adja c ent are as. Avo i d weld i ng near hydraulic lines. Have a fire extinguisher readily available.
6.b. Where compressed gases are to be used at the job site, special precautions should be used to prevent hazardous situations. Refer to “Safety in Welding and Cutting” (ANSI Standard Z49.1) and the operat in g in formati on for th e equipment being used.
6.c. When not welding, make cer tain no part of the electrode circuit is touching the work or ground. Accidental contact can cause overheating and create a fire hazard.
6.d. Do not heat, cut or weld tanks, drums or containers until the proper steps have been taken to insure that such procedures will not cause flammable or toxic vapors from substances inside. They can cause an explosion even been “cleaned”. For information, purchase “Recommended Safe Practices for the Co n t a iners an d Pi p i n g That Have He l d H a z a rdous Substances”, AWS F4.1 from the American Welding Society
(see address above).
6.e. Vent hollow castings or containers before heating, cutting or welding. They may explode.
Sparks and spatter are thrown from the welding arc. Wear oil
6.f. free protective garments such as leather gloves, heavy shirt, cuffless trousers, high shoes and a cap over your hair. Wear ear plugs when welding out of position or in confined places. Always wear safet y glasses with side shields when in a welding area.
6.g. Connect the work cable to the work as close to the welding area as practical. Work cables connected to the building framework or other locations away from the welding area incre ase th e possib il ity of t he welding current pa ss ing through lifting chains, crane cables or other alternate circuits. This can create fire hazards or overheat lifting chains or cables until they fail.
6.h. Also see item 1.c.
the weld ing spa rks from starting a fire.
though
they have
Preparation
for Welding and Cutting of
CYLINDER may explode if damaged.
7.a. Us e o n l y c ompre s s e d gas cyli n d e rs containing the correct shielding gas for the pr o c e ss us e d and p r o perly o p e r a ting re g u l ators de signed fo r th e gas and
pressure used. All hoses, fittings, etc. should be suitable for the application and maintained in good condition.
7.b. Always keep cyl ind ers in an u pright position sec ure ly chained to an undercarriage or fixed support.
7.c. Cylinders should be located:
• Away from areas where they may be struck or subjected to
physical damage.
• A safe distance from arc welding or cutting operations and
any other source of heat, sparks, or flame.
7.d. Never allow the electrode, electrode holder or any other electrically “hot” parts to touch a cylinder.
7.e. Keep your head and face away from the cylinder valve outlet when opening the cylinder valve.
7.f. Valve protection caps should always be in place and hand tight except when the cylinder is in use or connected for use.
7.g. Rea d and follow the i nstr u cti o ns on c o mpr ess e d ga s cylinders, associated equipment, and CGA publication P-l, “Precautions for Safe Handling of Compressed Gases in Cylinders,” available from the Compressed Gas Association 1235 Jefferson Davis Highway, Arlington, VA 22202.
FOR ELECTRICALLY powered equipment.
8.a. Turn off input power using the disconnect switch at the fuse box before working on the equipment.
8.b. Insta ll equipment in accordance w it h the U.S. N at ional Ele ctri cal Code, all l ocal co des and the manufacturer ’s recommendations.
8.c. Ground the equipment in accordance with the U.S. National Electrical Code and the manufacturer’s recommendations.
6.I. Read and follow NFPA 51B “ Standard for Fire Prevention During Welding, Cutting and Other Hot Work”, available from NFPA, 1 Batter ymarch Park, PO box 9101, Quincy, Ma 022690-9101.
6.j. Do not use a welding power source for pipe thawing.
Refer to http://www.lincolnelectric.com/safety for additional safety information.
Jan ‘09
Page 5
iv
SAFETY
iv
PRÉCAUTIONS DE SÛRETÉ
Pour votre propre protection lire et observer toutes les instructions et les précautions de sûreté specifiques qui parraissent dans ce manuel aussi bien que les précautions de sûreté générales suiv­antes:
Sûreté Pour Soudage A L’Arc
1. Protegez-vous contre la secousse électrique:
a. Les circuits à l’électrode et à la piéce sont sous tension
quand la machine à souder est en marche. Eviter toujours tout contact entre les parties sous tension et la peau nue ou les vétements mouillés. Porter des gants secs et sans trous pour isoler les mains.
b. Faire trés attention de bien s’isoler de la masse quand on
soude dans des endroits humides, ou sur un plancher metallique ou des grilles metalliques, principalement dans les positions assis ou couché pour lesquelles une grande partie du corps peut être en contact avec la masse.
c. Maintenir le porte-électrode, la pince de masse, le câble
de soudage et la machine à souder en bon et sûr état defonctionnement.
d.Ne jamais plonger le porte-électrode dans l’eau pour le
refroidir.
e. Ne jamais toucher simultanément les parties sous tension
des porte-électrodes connectés à deux machines à souder parce que la tension entre les deux pinces peut être le total de la tension à vide des deux machines.
f. Si on utilise la machine à souder comme une source de
courant pour soudage semi-automatique, ces precautions pour le porte-électrode s’applicuent aussi au pistolet de soudage.
6. Eloigner les matériaux inflammables ou les recouvrir afin de prévenir tout risque d’incendie dû aux étincelles.
7. Quand on ne soude pas, poser la pince à une endroit isolé de la masse. Un court-circuit accidental peut provoquer un échauffement et un risque d’incendie.
8. S’assurer que la masse est connectée le plus prés possible de la zone de travail qu’il est pratique de le faire. Si on place la masse sur la charpente de la construction ou d’autres endroits éloignés de la zone de travail, on augmente le risque de voir passer le courant de soudage par les chaines de lev­age, câbles de grue, ou autres circuits. Cela peut provoquer des risques d’incendie ou d’echauffement des chaines et des câbles jusqu’à ce qu’ils se rompent.
9. Assurer une ventilation suffisante dans la zone de soudage. Ceci est particuliérement important pour le soudage de tôles galvanisées plombées, ou cadmiées ou tout autre métal qui produit des fumeés toxiques.
10. Ne pas souder en présence de vapeurs de chlore provenant d’opérations de dégraissage, nettoyage ou pistolage. La chaleur ou les rayons de l’arc peuvent réagir avec les vapeurs du solvant pour produire du phosgéne (gas fortement toxique) ou autres produits irritants.
11.Pour obtenir de plus amples renseignements sur la sûreté, voir le code “Code for safety in welding and cutting” CSA Standard W 117.2-1974.
2. Dans le cas de travail au dessus du niveau du sol, se protéger contre les chutes dans le cas ou on recoit un choc. Ne jamais enrouler le câble-électrode autour de n’importe quelle partie du corps.
3. Un coup d’arc peut être plus sévère qu’un coup de soliel, donc:
a. Utiliser un bon masque avec un verre filtrant approprié
ainsi qu’un verre blanc afin de se protéger les yeux du ray­onnement de l’arc et des projections quand on soude ou quand on regarde l’arc.
b. Porter des vêtements convenables afin de protéger la
peau de soudeur et des aides contre le rayonnement de l‘arc.
c. Protéger l’autre personnel travaillant à proximité au
soudage à l’aide d’écrans appropriés et non-inflammables.
4. Des gouttes de laitier en fusion sont émises de l’arc de soudage. Se protéger avec des vêtements de protection libres de l’huile, tels que les gants en cuir, chemise épaisse, pan­talons sans revers, et chaussures montantes.
5. Toujours porter des lunettes de sécurité dans la zone de soudage. Utiliser des lunettes avec écrans lateraux dans les zones où l’on pique le laitier.
PRÉCAUTIONS DE SÛRETÉ POUR LES MACHINES À SOUDER À TRANSFORMATEUR ET À REDRESSEUR
1. Relier à la terre le chassis du poste conformement au code de l’électricité et aux recommendations du fabricant. Le dispositif de montage ou la piece à souder doit être branché à une bonne mise à la terre.
2. Autant que possible, I’installation et l’entretien du poste seront effectués par un électricien qualifié.
3. Avant de faires des travaux à l’interieur de poste, la debranch­er à l’interrupteur à la boite de fusibles.
4. Garder tous les couvercles et dispositifs de sûreté à leur place.
Mar. ‘93
Page 6
v
SAFETY
Electromagnetic Compatibility (EMC)
Conformance Products displaying the CE mark are in conformity with European Community Council Directive of 3 May 1989 on the approximation of the laws of the Member States relating to electromagnetic compatibility (89/336/EEC). It was manufactured in conformity with a national standard that implements a harmonized standard: EN 60974-10 Electromagnetic Compatibility (EMC) Product Standard for Arc Welding Equipment. It is for use with other Lincoln Electric equipment. It is designed for industrial and professional use.
Introduction All electrical equipment generates small amounts of electromagnetic emission. Electrical emission may be transmitted through power lines or radiated through space, similar to a radio transmitter. When emissions are received by other equipment, electrical interference may result. Electrical emissions may affect many kinds of electrical equipment; other nearby welding equipment, radio and TV reception, numerical controlled machines, telephone systems, computers, etc. Be aware that interference may result and extra precautions may be required when a welding power source is used in a domestic establishment.
Installation and Use The user is responsible for installing and using the welding equipment according to the manufacturer’s instructions. If electromagnetic disturbances are detected then it shall be the responsibility of the user of the welding equipment to resolve the situation with the technical assistance of the manufacturer. In some cases this remedial action may be as simple as earthing (grounding) the welding circuit, see Note. In other cases it could involve construction of an electromagnetic screen enclosing the power source and the work complete with associated input filters. In all cases electromagnetic disturbances must be reduced to the point where they are no longer troublesome.
v
Note: The welding circuit may or may not be earthed for safety reasons according to national codes.
Changing the earthing arrangements should only be authorized by a person who is compe­tent to access whether the changes will increase the risk of injury, e.g., by allowing parallel welding current return paths which may damage the earth circuits of other equipment.
Assessment ofArea Before installing welding equipment the user shall make an assessment of potential electromagnetic prob­lems in the surrounding area. The following shall be taken into account:
a) other supply cables, control cables, signaling and telephone cables; above, below and adjacent to the
welding equipment; b) radio and television transmitters and receivers; c) computer and other control equipment; d) safety critical equipment, e.g., guarding of industrial equipment; e) the health of the people around, e.g., the use of pacemakers and hearing aids; f) equipment used for calibration or measurement g) the immunity of other equipment in the environment. The user shall ensure that other equipment being
used in the environment is compatible. This may require additional protection measures; h) the time of day that welding or other activities are to be carried out.
L10093 3-1-96H
Page 7
vi
SAFETY
Electromagnetic Compatibility (EMC)
The size of the surrounding area to be considered will depend on the structure of the building and other activities that are taking place. The surrounding area may extend beyond the boundaries of the premises.
Methods of Reducing Emissions Mains Supply
Welding equipment should be connected to the mains supply according to the manufacturer’s recommenda­tions. If interference occurs, it may be necessary to take additional precautions such as filtering of the mains supply. Consideration should be given to shielding the supply cable of permanently installed welding equip­ment, in metallic conduit or equivalent. Shielding should be electrically continuous throughout its length. The shielding should be connected to the welding power source so that good electrical contact is maintained between the conduit and the welding power source enclosure.
Maintenance of the Welding Equipment The welding equipment should be routinely maintained according to the manufacturer’s recommendations. All access and service doors and covers should be closed and properly fastened when the welding equip­ment is in operation. The welding equipment should not be modified in any way except for those changes and adjustments covered in the manufacturers instructions. In particular, the spark gaps of arc striking and stabilizing devices should be adjusted and maintained according to the manufacturer’s recommendations.
vi
Welding Cables The welding cables should be kept as short as possible and should be positioned close together, running at or close to floor level.
Equipotential Bonding Bonding of all metallic components in the welding installation and adjacent to it should be considered. However, metallic components bonded to the work piece will increase the risk that the operator could receive a shock by touching these metallic components and the electrode at the same time. The operator should be insulated from all such bonded metallic components.
Earthing of the Workpiece Where the workpiece is not bonded to earth for electrical safety, not connected to earth because of its size and position, e.g., ships hull or building steelwork, a connection bonding the workpiece to earth may reduce emissions in some, but not all instances. Care should be taken to prevent the earthing of the workpiece increasing the risk of injury to users, or damage to other electrical equipment. Where necessary, the connec­tion of the workpiece to earth should be made by a direct connection to the workpiece, but in some countries where direct connection is not permitted, the bonding should be achieved by suitable capacitance, selected according to national regulations.
Screening and Shielding Selective screening and shielding of other cables and equipment in the surrounding area may alleviate prob­lems of interference. Screening of the entire welding installation may be considered for special applications. 1
_________________________
1
Portions of the preceding text are contained in EN 60974-10: “Electromagnetic Compatibility (EMC) prod­uct standard for arc welding equipment.”
L10093 3-1-96H
Page 8
viivii
for selecting one of our QUALITY products. We want you to take
TThhaannkk YYoouu
CUSTOMER ASSISTANCE POLICY
The business of our company is manufacturing and selling high quality welding equipment. Our challenge is to meet the needs of our customers and to exceed their expectations. On occasion, purchasers may ask us for advice or information about their use of our products. We respond to our customers based on the best informa­tion in our possession at that time. We are not in a position to warrant or guarantee such advice, and assume no liability, with respect to such information or advice. We expressly disclaim any warranty of any kind, including any warranty of fitness for any customer’s particular purpose, with respect to such information or advice. As a matter of practical consideration, we also cannot assume any responsibility for updating or correcting any such informa­tion or advice once it has been given, nor does the provision of information or advice create, expand or alter any warranty with respect to the sale of our products.
We are a responsive manufacturer, but the selection and use of specific products sold by us is solely within the control of, and remains the sole responsibility of the customer. Many variables beyond our control affect the results obtained in applying these types of fabrication methods and service requirements.
Subject to Change – This information is accurate to the best of our knowledge at the time of printing.
pride in operating this product ••• as much pride as we have in bringing this product to you!
Please Examine Carton and Equipment For Damage Immediately
When this equipment is shipped, title passes to the purchaser upon receipt by the carrier. Consequently, Claims for material damaged in shipment must be made by the purchaser against the transportation company at the time the shipment is received.
Please record your equipment identification information below for future reference. This information can be found on your machine nameplate.
Product _________________________________________________________________________________ Model Number ___________________________________________________________________________ Code Number or Date Code (if available)______________________________________________________ Serial Number (if available)__________________________________________________________________ Date Purchased___________________________________________________________________________ Where Purchased_________________________________________________________________________ Whenever you request replacement parts or information on this equipment, always supply the information you
have recorded above.
Read this Operators Manual completely before attempting to use this equipment. Save this manual and keep it handy for quick reference. Pay particular attention to the safety instructions we have provided for your protection. The level of seriousness to be applied to each is explained below:
WARNING
This statement appears where the information must be followed exactly to avoid serious personal injury or loss of life.
CAUTION
This statement appears where the information must be followed to avoid minor personal injury or damage to this equipment.
Page 9
viii
TABLE OF CONTENTS
Page
Installation.......................................................................................................................Section A
Technical Specifications .......................................................................................................A-1
Safety Precautions.................................................................................................A-2
Select Suitable Location.......................................................................................................A-2
Stacking................................................................................................................................A-2
Tilting....................................................................................................................................A-2
Input Connections ................................................................................................................A-2
Ground Connection..............................................................................................................A-2
Input Power Connection.......................................................................................................A-2
120V Input............................................................................................................................A-3
Output Connections..............................................................................................................A-3
Stick Welding........................................................................................................................A-3
________________________________________________________________________________
Operation.........................................................................................................................Section B
Safety Instructions................................................................................................................B-1
General Description..............................................................................................................B-1
Welding Capability................................................................................................................B-1
Limitations ............................................................................................................................B-1
Controls and Operational Features,Front and Rear Control Panel......................................B-2
Arc Welding Circuit...............................................................................................................B-3
Electric Arc ...........................................................................................................................B-3
Making the Weld...........................................................................................................B-3, B-4
________________________________________________________________________
viii
Maintenance ....................................................................................................Section D
Safety Precautions ................................................................................................D-1
Routine Maintenance.............................................................................................D-1
________________________________________________________________________
Troubleshooting..............................................................................................Section E
How to Use Troubleshooting Guide.......................................................................E-1
Troubleshooting Guide............................................................................E-2 thru E-3
________________________________________________________________________
Wiring Diagram................................................................................................Section F
________________________________________________________________________
Parts Pages.............................................................................................................P-603
––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––
Page 10
A-1
INSTALLATION
TECHNICAL SPECIFICATION INVERTER ARC™ 120
INPUT - SINGLE PHASE ONLY
Input Voltages 60 Hz.
Rated Input Current
A-1
120Vac ± 15%
20 Amps @ Rated Output
RATED OUTPUT
Duty Cycle
20%
Output Amps
70A (Stick)
Output Volts
22.8 Vdc
Input Circuit
120 Vac
OUTPUT
Output Current Range
10-90 Amps
Maximum Open Circuit Voltage
72 Volts Max.
Type of Output
DC
RECOMMENDED INPUT WIRE AND FUSE SIZES FOR MAXIMUM RATED OUTPUT
INPUT VOLTAGE / FREQUENCY (HZ)
120/60
TYPE SJT OR HARD USAGE INPUT
CORD
3 Conductor, 14 AWG
MAXIMUM TIME-DELAY CIRCUIT
BREAKER OR FUSE SIZE (AMPS)
20
PHYSICAL DIMENSIONS
Height Width Length Weight
7.5 in. 5.0 in. 10.9 in. Approx. 14.0 lbs.
190.5 mm 127.0 mm 276.9 mm 6.4 kgs.
TEMPERATURE RANGES
OPERATING TEMPERATURE RANGE
-10°C to +40°C
STORAGE TEMPERATURE RANGE
-25°C to +55°C
INVERTER ARC™ 120
Page 11
A-2
INSTALLATION
A-2
Read entire installation section before starting installation.
SAFETY PRECAUTIONS
WARNING
ELECTRIC SHOCK can kill.
Only qualified personnel should per-
form this installation.
•Disconnect input power by removing plug from receptacle before working inside INVERTER ARC™ 120. Allow machine to sit for 5 minutes mum to allow the power capacitors to discharge before working inside this equipment.
Insulate yourself from the work and ground.
Always wear dry insulating gloves.
• Always connect the INVERTER ARC™ 120 to a power supply grounded according to the National
Electrical Code and local codes.
------------------------------------------------------------
SELECT SUITABLE LOCATION
This machine can operate in harsh environments. However, it is important that simple preventative measures are followed to assure long life and reliable operation:
• This machine must be located where there is free circulation of clean air without restrictions for air movement to and from the air vents. Do not cover the machine with paper, cloth or rags when switched on.
• Dirt and dust that can be drawn into the machine should be kept to a minimum.
• This machine has a protection rating of IP21S. Keep it dry and do not place it on wet ground or in puddles. Do not use in wet or damp locations. Store indoors.
• Locate the machine away from radio controlled machinery. Normal operation may adversely affect the operation of nearby radio controlled machinery, which may result in injury or equipment damage. Read the section on electromagnetic compatibility in this manual.
• Do not operate in areas with an ambient tempera­ture greater than 40°C.
STACKING
The INVERTER ARC™ 120 cannot
be stacked.
mini-
TILTING
Place the machine directly on a secure, level surface. Do not place or operate this machine on a surface with an incline greater than 15° from horizontal. The machine may topple over if this procedure is not fol­lowed.
INPUT CONNECTIONS
GROUND CONNECTION
The frame of the welder must be ground­ed. A ground terminal marked with the symbol is located on the under panel for this purpose. See your local and national electrical codes for proper grounding methods.
WARNING
A grounding conductor is supplied in the input cord, it is important that the supply receptacle ground is connected.
The welding power source supply cable is pro-
vided with a green or yellow/green wire that must ALWAYS be earthed. This green or yellow/green wire must NEVER be used with other voltage conductors.
• Only install plugs that conform with safety regu­lations.
------------------------------------------------------------
INPUT POWER CONNECTION
Check the input voltage, phase, and frequency sup­plied to this machine before turning it on. The allow­able input voltage is indicated in the technical specifi­cation section of this manual and on the rating plate of the machine. Be sure that the machine is grounded.
Make sure the power available at the input connection is adequate for normal operation of the machine. The fuse rating and cable sizes are both indicated in the technical specification section of this manual.
Fuse the input circuit with time delay fuses marked “D” or delay type breakers smaller than recommended may result in “nuisance” shut-offs from welder inrush currents even if not welding at high currents.
(1)
Also called “inverse time” or “thermal/magnetic” circuit breakers.
Th ese cir cui t bre aker s h a ve a d ela y in tri p pin g act i on tha t decreases as the magnitude of the current increases.
The INVERTER ARC™ 120 is recommended for use on an individual branch circuit.
(1)
circuit breakers. Using fuses or circuit
INVERTER ARC™ 120
Page 12
A-3
INSTALLATION
A-3
120V INPUT
The INVERTER ARC™ 120 is provided with a 120V cable, 6.0ft.(1.8m) in length, with a 15Amp 5-15P plug molded onto the cord.
The rated output of the INVERTER ARC™ 120 is available when connected to a 20A branch circuit. When connected to a branch circuit with lower ampac­ity, lower welding current and duty cycle must be used. An output guide is provided below. The values are approximate and must be adjusted downward if the fuse or circuit breaker trips off. Other loads on the circuit and fuse/circuit breaker characteristics will affect the available output. Do not exceed these weld­ing conditions: (See Table A.1)
TABLE A.1
BRANCH CIRCUITS
120V Input
Plug
Rating 15 Amp 15 Amp
Branch
Rating 15 Amp 20 Amp
Output Current
20% Duty
Cycle
55A 70A
10% Duty
Cycle
60A 80A
FIGURE A.1
Electrode Holder
Work Clamp
Work Cable
Factory Installed
Electrical Holder and Cable Assembly Work Cable and Clamp Strap Packet Instruction Manual
OUTPUT CONNECTIONS
A quick disconnect system using Twist-Mate™ cable plugs is used for the welding cable connections.
WARNING
ELECTRIC SHOCK can kill.
• Keep the electrode holder and cable insulation in good condition.
• Do not touch electrically live parts or electrode with skin or wet clothing.
• Insulate yourself from work and ground.
• Turn the input line Switch on the INVERTER ARC™ 120 “off” before connecting or discon­necting output cables or other equipment.
------------------------------------------------------------
STICK WELDING (MMA)
Connect the electrode cable to the (+) terminal and the work clamp to the (-) terminal. Insert the connector with the key lining up with the keyway and rotate approxi­mately 1/4 turn clockwise. Do not over tighten. (See Figure A.1)
INVERTER ARC™ 120
Page 13
B-1
OPERATION
B-1
Read and understand this entire section before operating your machine.
SAFETY INSTRUCTIONS
WARNING
ELECTRIC SHOCK can kill.
• Do not touch electrically live parts such as output terminals or internal wiring.
• Insulate yourself from the work and ground.
• Always wear dry insulating gloves.
------------------------------------------------------------
FUMES AND GASES can be dangerous.
• Keep your head out of fumes.
• Use ventilation or exhaust to remove fumes from breathing zone.
------------------------------------------------------------
WELDING, CUTTING and GOUGING SPARKS can cause fire or explosion
• Keep flammable material away.
• Do not weld, cut or gouge on contain­ers that have held combustibles.
WELDING CAPABILITY
The INVERTER ARC™ 120 is rated at 70 amps, 22.8 volts, at 20% duty cycle on a ten minute basis. It is capable of higher duty cycles at lower output currents. If the duty cycle is exceeded, a thermal protector will shut off the output until the machine cools. See Table A.1 in the INSTALLATION Section for other rated out- puts.
The INVERTER ARC™ 120 is recommended for the following Electrode Types and Diameters:
Sizes (in.)
Types
Fleetweld 37 (E6013) Fleetweld 35 (E6011) Excalibur 7018 MR (E7018)
X - 15 Amp Branch circuit or greater required.
- 20 Amp Branch circuit or greater required.
1/16
X
-
-
5/64
X
-
-
3/32
X
1/8
-
-
LIMITATIONS
The INVERTER ARC™ 120 is not recommended for pipe thawing.
------------------------------------------------------------
ARC RAYS can burn.
• Wear eye, ear and body protection.
------------------------------------------------------------
Only qualified personnel should operate this equip­ment. Observe all safety information throughout this manual.
------------------------------------------------------------
GENERAL DESCRIPTION
The INVERTER ARC™ 120 is a 90 amp arc welding power source which utilizes single phase input power to produce constant current output. The welding response of this Inverter has been optimized for stick (SMAW) welding.
INVERTER ARC™ 120
Page 14
B-2
1
2
3
4
5
8
6
7
ON
OFF
A
CONTROLS AND OPERATIONAL FEATURES
OPERATION
REAR CONTROL PANEL
(See Figure B.2)
B-2
FRONT CONTROL PANEL
(See Figure B.1)
1. Output Current Knob: Potentiometer used to set the output current used during welding. Set the output according to the type and size of electrode.
2. Power LED: After the Power Switch is turned on the LED will illuminate.
3. Thermal LED: This indicator will turn on when the machine is overheated and the output has been disabled. This normally occurs when the duty cycle of the machine has been exceeded. Leave the machine on to allow the internal components to cool. When the indicator turns off, normal operation is again possible.
4. Positive Quick Disconnect: Positive output con­nector for the welding circuit.
5. Negative Quick Disconnect: Negative output con­nector for the welding circuit.
FIGURE B.1
6. Power Switch: It turns ON / OFF the input power
to the machine.
7. Input cable: This machine is provided with a plugged input cord. Connect it to the mains.
8. Fan
FIGURE B.2
INVERTER ARC™ 120
Page 15
B-3
OPERATION
B-3
ARC-WELDING CIRCUIT
(See Figure B.3)
FIGURE B.3
Current flows through the electrode cable and elec­trode holder to the electrode and across the arc. On the work side of the arc, the current flows through the base metal to the work cable and back to the welding machine. The circuit must be complete for the current to flow.
To weld, the work clamp must be tightly connected to clean base metal. Remove paint, rust, etc. as neces­sary to get a good connection. Connect the work clamp as close as possible to the area you wish to weld. Avoid allowing the welding circuit to pass through hinges, bearings, electronic components or similar devices that can be damaged.
An electric arc is made between the work and the end of a small metal rod, the electrode, which is clamped in a holder and the holder is held by the person doing the welding. A gap is made in the welding circuit (see Figure B.3) by holding the tip of the electrode 1/16­1/8” away from the work or base metal being welded. The electric arc is established in this gap and is held and moved along the joint to be welded, melting the metal as it is moved.
ELECTRIC ARC
(See Figure B.4) Action that takes place in the electric arc.
FIGURE B.4
This figure closely resembles what is actually seen during welding. The “arc stream’’ is seen in the middle of the figure. This is the electric arc created by the electric current flowing through the space between the end of the electrode and the work.
The temperature of this arc is about 6000°F (3315°C), which is more than enough to melt metal. The arc is very bright, as well as hot, and cannot be looked at with the naked eye without risking painful injury. A very dark lens, specifically designed for arc welding, must be used with a hand or face shield whenever viewing the arc. The arc melts the base metal and actually digs into it, much as water through a nozzle on a gar­den hose digs into the earth. The molten metal forms a pool or crater and tends to flow away from the arc. As it moves away from the arc, it cools and solidifies. A slag forms on top of the weld to protect it during cooling.
The function of the covered electrode is much more than simply to carry current to the arc. The electrode is composed of a core rod of metal with an extruded chemical covering. The core rod melts in the arc and tiny droplets of molten metal shoot across the arc into the molten pool. The electrode provides additional filler metal for the joint to fill the groove or gap between the two pieces of the base metal. The cover­ing also melts or burns in the arc. It has several func­tions. It makes the arc steadier, provides a shield of smoke-like gas around the arc to keep oxygen and nitrogen in the air away from the molten metal, and provides a flux for the molten pool. The flux picks up impurities and forms the protective slag.
MAKING A WELD
Insert the bare part of the electrode into the electrode holder jaws and connect the work clamp to the weld­ing piece. Make sure to have good electrical contact.
1. Turn the welder on.
2. Lower your welding helmet to protect your face and eyes.
3. Strike the electrode at the work point on the work­piece as if striking a match. Do not hit the electrode on the workpiece, which will damage the stick elec­trode and make striking an arc difficult. Scratch the electrode slowly over the metal and you will see sparks. While scratching, lift the electrode 1/8" (3.2mm) and the arc will establish.
NOTE: If you stop moving the electrode while scratch-
ing, the electrode will stick.
NOTE: Most beginners try to strike the arc by a fast
jabbing motion down on the plate. Result: They either stick or their motion is so fast that they break the arc immediately.
INVERTER ARC™ 120
Page 16
B-4
OPERATION
B-4
4. Immediately after striking the arc try to maintain a distance from the workpiece that is equivalent to the diameter of the electrode used. Maintain this distance as constantly as possible during the weld. Whenever possible, weld from left to right (if right­handed). Hold the electrode at a slight angle as shown. (See Figure B.5)
FIGURE B.5
5. As the electrode burns off the electrode must be fed to the work to maintain correct arc length. The easi­est way to tell whether the arc has the correct length is by listening to its sound. A nice, short arc has a distinctive, “crackling” sound, very much like eggs frying in a pan. The incorrect, long arc has a hollow, blowing or hissing sound.
7. Once the electrode is burned down move the elec­trode quickly from the weld to extinguish the arc.
8. Turn the machine off and remove the stub by open­ing the jaws of the electrode holder and insert a new electrode.
Note: The welded work piece and electrode stub are
hot after welding. Allow them to cool down before touching or use pliers to move. Always make sure the welder is turned off before set­ting down the Electrode Holder.
6. The important thing to watch while welding is the puddle of molten metal right behind the arc. Do NOT watch the arc itself. It is the appearance of the puddle and the ridge where the molten puddle solidifies that indicate correct welding speed. The ridge should be approximately 3/8" (9.5mm) behind the electrode. (See Figure B.6)
FIGURE B.6
Most beginners tend to weld too fast, resulting in a thin, uneven, “wormy” looking bead. They are not watching the molten metal.
IMPORTANT: For general welding it is not necessary to weave the arc; neither forwards and backwards nor sideways. Weld along at a steady pace. You will find it easier. NOTE: When welding on thin plate, you will find that you will have to increase the welding speed, whereas when welding on heavy plate, it is necessary to go more slowly in order to get good penetration.
INVERTER ARC™ 120
Page 17
D-1
MAINTENANCE
SAFETY PRECAUTIONS
WARNING
ELECTRIC SHOCK can kill.
• Have an electrician install and serv­ice this equipment.
• Turn the input power off at the fuse box, disconnect supply lines and allow machine to sit for five minutes minimum to allow the power capaci­tors to discharge before working inside this equipment.
• Do not touch electrically hot parts.
------------------------------------------------------------
ROUTINE MAINTENANCE
The frequency of the maintenance operations may vary in accordance with the working environment. Any noticeable damage should be reported immedi­ately.
D-1
WARNING
Do not open this machine and do not introduce any­thing into its openings. Power supply must be discon­nected from the machine before each maintenance and service. After each repair, perform proper tests to ensure safety.
CAUTION
Power supply must be disconnected from the machine before each maintenance and service. Always use gloves in compliance with the safety standards.
------------------------------------------------------------
• Check cables and connections integrity. Replace, if necessary.
• Clean the power source inside by means of low ­pressure compressed air.
• Keep the machine clean. Use a soft dry cloth to clean the external case, especially the airflow inlet / outlet louvers.
INVERTER ARC™ 120
Page 18
E-1
TROUBLESHOOTING
HOW TO USE TROUBLESHOOTING GUIDE
WARNING
Service and Repair should only be performed by Factory Trained Personnel. Unauthorized repairs performed on this equipment may result in danger to the technician and machine operator and will invalidate your factory warranty. For your safety and to avoid Electrical Shock, please observe all safety notes and precautions detailed throughout this manual.
__________________________________________________________________________
E-1
This Troubleshooting Guide is provided to help you locate and repair possible machine malfunctions. Simply follow the three-step procedure listed below.
Step 1. LOCATE PROBLEM (SYMPTOM).
Look under the column labeled “PROBLEM (SYMP­TOMS)”. This column describes possible symptoms that the machine may exhibit. Find the listing that best describes the symptom that the machine is exhibiting.
Step 2. POSSIBLE CAUSE.
The second column labeled “POSSIBLE CAUSE” lists the obvious external possibilities that may contribute to the machine symptom.
Step 3. RECOMMENDED COURSE OF ACTION
This column provides a course of action for the Possible Cause, generally it states to contact your local Authorized Field Service Facility.
If you do not understand or are unable to perform the Recommended Course of Action safely, contact your local Authorized Field Service Facility.
CAUTION
If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your
Local Authorized Field Service Facility for technical troubleshooting assistance before you proceed.
INVERTER ARC™ 120
Page 19
E-2
TROUBLESHOOTING
Observe all Safety Guidelines detailed throughout this manual
E-2
PROBLEMS
(SYMPTOMS)
Excessive spatter
Craters
Inclusions
Insufficient penetration
Electrode Sticking
POSSIBLE
CAUSE
WELDING PROBLEMS
1. Improper welding polarity.
2. Long Arc Length.
3. High Current.
1. Fast movement of the electrode away from the work piece.
1. Poor cleanliness.
2. Poor distribution of the welding passes.
1. High travel speed.
2. Welding current is too low.
1. Arc length is too short.
2. Welding current is too low.
RECOMMENDED
COURSE OF ACTION
1. Make sure the electrode holder is plugged into the positive “+” out­put terminal.
2. Move the electrode closer into the weld joint.
3. Turn the output knob down.
1. Maintain a steady consistent arc length
1. Clean work piece with wire brush prior to welding.
2. Consult a welding guide for proper weld bead placement.
1. Travel at a slower speed.
2. Adjust welding output higher.
1. Move the electrode further away from the weld joint.
2. Turn the output knob up.
Porosity
Cracks
1. Humidity in the electrode.
2. Long arc length.
1. Weld current is set too high.
2. Dirty materials.
3. Hydrogen in the weld due to mois­ture.
1. Store welding electrodes in a warm dry place.
2. Move the electrode closer into the weld joint.
1. Turn the output knob down.
2. Clean work piece with wire brush prior to welding.
3. Store welding electrodes in a warm dry place.
CAUTION
If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your
Local Authorized Field Service Facility for technical troubleshooting assistance before you proceed.
INVERTER ARC™ 120
Page 20
E-3
TROUBLESHOOTING
Observe all Safety Guidelines detailed throughout this manual
E-3
PROBLEMS
(SYMPTOMS)
ELECTRICAL FAILURES
Machine fails to come on
(Power LED off)
Thermal overload
(Thermal LED on)
The fan works, but the output current is unstable and can not be controlled by the potentiometer while welding is carried out.
POSSIBLE
CAUSE
1. No Input Voltage.
2. Faulty supply plug or cable.
3. Supply fuse blown or breaker tripped.
1. Unit has been operated beyond its capacity rating.
2. Airflow through machine is restrict­ed or fan has failed.
1. Check the output current poten­tiometer, and replace it if neces­sary.
2. Verify output cables are attached to the welder and tightly connect­ed.
RECOMMENDED
COURSE OF ACTION
If all recommended possible areas of misadjustment have been checked and the problem persists, Contact
your local Authorized Field Service Facility.
CAUTION
If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your
Local Authorized Field Service Facility for technical troubleshooting assistance before you proceed.
INVERTER ARC™ 120
Page 21
F-1
OUTPUT
TERMINALS
MAIN
TRANSFORMER
FAN
FEEDBACK
CIRCUIT
C
O
N
T
R
O
L
M
O
D
U
L
E
GROUND
LEAD
ON / OFF
SWITCH
INPUT
POWER
LED
THERMAL
LED
OUTPUT
POTENTIOMETER
THERMOSTAT
OUTPUT
BOARD
INPUT
BOARD
DRIVE MODULE
RELAY
DC POWER
SUPPLY
GROUND
LEAD
MAIN
BOARD
INVERTER ARC 120 - WIRING DIAGRAM
DIAGRAMS
F-1
WIRING DIAGRAM FOR CODE 11565
NOTE: This diagram is for reference only. It may not be accurate for all machines covered by this manual. The specific diagram for a particular code is pasted inside
the machine on one of the enclosure panels. If the diagram is illegible, write to the Service Department for a replacement. Give the equipment code number.
INVERTER ARC™ 120
Page 22
WARNING
Spanish
AVISO DE
PRECAUCION
Do not touch electrically live parts or
electrode with skin or wet clothing.
Insulate yourself from work and
ground.
No toque las partes o los electrodos
bajo carga con la piel o ropa moja­da.
Aislese del trabajo y de la tierra.
Keep flammable materials away.
Mantenga el material combustible
fuera del área de trabajo.
Wear eye, ear and body protection.
Protéjase los ojos, los oídos y el
cuerpo.
French
ATTENTION
German
WARNUNG
Portuguese
ATENÇÃO
Japanese
Chinese
Korean
Arabic
Ne laissez ni la peau ni des vête-
ments mouillés entrer en contact avec des pièces sous tension.
Isolez-vous du travail et de la terre.
Berühren Sie keine stromführenden
Teile oder Elektroden mit Ihrem Körper oder feuchter Kleidung!
Isolieren Sie sich von den
Elektroden und dem Erdboden!
Não toque partes elétricas e elec-
trodos com a pele ou roupa molha­da.
Isole-se da peça e terra.
Gardez à l’écart de tout matériel
inflammable.
Entfernen Sie brennbarres Material!
Mantenha inflamáveis bem guarda-
dos.
Protégez vos yeux, vos oreilles et
votre corps.
Tragen Sie Augen-, Ohren- und Kör-
perschutz!
Use proteção para a vista, ouvido e
corpo.
READ AND UNDERSTAND THE MANUFACTURER’S INSTRUCTION FOR THIS EQUIPMENT AND THE CONSUMABLES TO BE USED AND FOLLOW YOUR EMPLOYER’S SAFETY PRACTICES.
SE RECOMIENDA LEER Y ENTENDER LAS INSTRUCCIONES DEL FABRICANTE PARA EL USO DE ESTE EQUIPO Y LOS CONSUMIBLES QUE VA A UTILIZAR, SIGA LAS MEDIDAS DE SEGURIDAD DE SU SUPERVISOR.
LISEZ ET COMPRENEZ LES INSTRUCTIONS DU FABRICANT EN CE QUI REGARDE CET EQUIPMENT ET LES PRODUITS A ETRE EMPLOYES ET SUIVEZ LES PROCEDURES DE SECURITE DE VOTRE EMPLOYEUR.
LESEN SIE UND BEFOLGEN SIE DIE BETRIEBSANLEITUNG DER ANLAGE UND DEN ELEKTRODENEINSATZ DES HER­STELLERS. DIE UNFALLVERHÜTUNGSVORSCHRIFTEN DES ARBEITGEBERS SIND EBENFALLS ZU BEACHTEN.
Page 23
Keep your head out of fumes.
Use ventilation or exhaust to
remove fumes from breathing zone.
Turn power off before servicing.
Do not operate with panel open or
guards off.
WARNING
Los humos fuera de la zona de res-
piración.
Mantenga la cabeza fuera de los
humos. Utilice ventilación o aspiración para gases.
Gardez la tête à l’écart des fumées.
Utilisez un ventilateur ou un aspira-
teur pour ôter les fumées des zones de travail.
Vermeiden Sie das Einatmen von
Schweibrauch!
Sorgen Sie für gute Be- und
Entlüftung des Arbeitsplatzes!
Mantenha seu rosto da fumaça.
Use ventilação e exhaustão para
remover fumo da zona respiratória.
Desconectar el cable de ali-
mentación de poder de la máquina antes de iniciar cualquier servicio.
Débranchez le courant avant l’entre-
tien.
Strom vor Wartungsarbeiten
abschalten! (Netzstrom völlig öff­nen; Maschine anhalten!)
Não opere com as tampas removidas.
Desligue a corrente antes de fazer
serviço.
Não toque as partes elétricas nuas.
No operar con panel abierto o
guardas quitadas.
N’opérez pas avec les panneaux
ouverts ou avec les dispositifs de protection enlevés.
Anlage nie ohne Schutzgehäuse
oder Innenschutzverkleidung in Betrieb setzen!
Mantenha-se afastado das partes
moventes.
Não opere com os paineis abertos
ou guardas removidas.
Spanish
AVISO DE
PRECAUCION
French
ATTENTION
German
WARNUNG
Portuguese
ATENÇÃO
Japanese
Chinese
Korean
Arabic
LEIA E COMPREENDA AS INSTRUÇÕES DO FABRICANTE PARA ESTE EQUIPAMENTO E AS PARTES DE USO, E SIGA AS PRÁTICAS DE SEGURANÇA DO EMPREGADOR.