Central Pneumatic Air Compressor 99901 User Manual

Page 1
PORTABLE COMPRESSED
CO2 REGULATOR
99901
OPERATING INSTRUCTIONS
Distributed exclusively by Harbor Freight Tools®.
3491 Mission Oaks Blvd., Camarillo, CA 93011
Visit our website at: http://www.harborfreight.com
Read this material before using this product.
Failure to do so can result in serious injury. SAVE THIS MANUAL.
Copyright© 2008 by Harbor Freight Tools®. All rights reserved. No portion of this manual or any artwork contained herein may be reproduced in any shape or form without the express written consent of Harbor Freight Tools. Diagrams within this manual may not be drawn proportionally. Due to continuing improvements, actual product may differ slightly from the product described herein. Tools required for assembly and service may not be included.
For technical questions or replacement parts, please call 1-800-444-3353.
Page 2
SAVE THIS MANUAL
Keep this manual for the safety warn­ings and precautions, assembly, operating, inspection, maintenance and cleaning pro­cedures. Write the product’s serial number in the back of the manual (or month and year of purchase if product has no num­ber). Keep this manual and the receipt in a safe and dry place for future reference.
NOTICE is used to
address practices
not related to personal injury.
CAUTION, without
the safety alert symbol, is used to address practices not related to personal injury.
Safety Alert Symbol and Signal
Words
In this manual, on the labeling, and all other information provid­ed with this product:
This is the safety alert
symbol. It is used to alert you to potential personal injury hazards. Obey all safety messages that follow this symbol to avoid possible injury or death.
DANGER indicates
a hazardous situation which, if not avoided, will result in death or serious injury.
IMPORTANT SAFETY
INSTRUCTIONS
INSTRUCTIONS PERTAINING
TO A RISK OF FIRE,
ELECTRIC SHOCK, OR
INJURY TO PERSONS
WARNING – When using regulators, basic
precautions should always be fol­lowed, including the following:
General
To reduce the risks of electric a.
shock, re, and injury to persons,
read all the instructions before us­ing the regulator.
Work area
WARNING
indicates a hazardous situation which, if not avoided, could result in death or serious injury.
CAUTION, used
with the safety alert symbol, indicates a hazardous situation which, if not avoided, could result in minor or moderate injury.
SKU 99901 For technical questions, please call 1-800-444-3353. Page 2
Keep the work area clean and well a. lighted. Cluttered benches and dark
areas increase the risks of electric
shock, re, and injury to persons.
Keep bystanders, children, and b. visitors away while operating the regulator. Distractions are able to
result in the loss of control of the regulator.
Page 3
Personal safety
Stay alert. Watch what you are do-a. ing and use common sense when operating the regulator. Do not use the regulator while tired or un-
der the inuence of drugs, alcohol,
or medication. A moment of inatten- tion while operating the regulator in-
creases the risk of injury to persons.
Avoid unintentional starting. Be b. sure the tool switch is off before connecting to the CO2 Regulator.
Do not connect the tool to the CO2 Regulator with the switch on.
c. Always wear eye protec-
tion. Wear ANSI-ap­proved safety goggles.
d. Always wear hearing
protection when using the regulator. Prolonged
exposure to high intensity
noise is able to cause hearing loss.
Do not use the regulator if the f. Regulator Control Knob does not function properly. Any regulator that
cannot be controlled is dangerous and must be repaired.
Disconnect the tool from the COg. Regulator before making any ad­justments, changing accessories, or storing the tool. Such preventive
safety measures reduce the risk of starting the tool unintentionally. Turn off and detach the CO2 supply, safely discharge any residual pressure, and release the throttle and/or turn the switch to its off position before leav­ing the work area.
Store the regulator and gas canis-h.
ter when idle out of reach of chil­dren and other untrained persons.
A regulator is dangerous in the hands of untrained users.
Do not exceed 150 PSI input pres-i. sure.
2
Regulator use and care
Use only with tools specically de-a. signed for use with bottled gasses.
Read tool manual before connec-b. tion and/or use.
Assemble, use and store in a well-c. ventilated area only. Carbon dioxide
gas is invisible and odorless can ac-
cumulate in conned spaces.
Use with carbon dioxide gas only.d.
Attach the Hose properly to the e. Regulator and tool before use. A
loose Hose may detach or break dur­ing operation.
WARNING: The brass compo-j. nents of this product contain lead, a chemical known to the State of California to cause birth defects (or other reproductive harm). (California Health & Safety code
25249.5, et seq.)
The warnings and precautions k. discussed in this manual cannot cover all possible conditions and situations that may occur. It must
be understood by the operator that common sense and caution are fac­tors which cannot be built into this product, but must be supplied by the operator.
SKU 99901 For technical questions, please call 1-800-444-3353. Page 3
Page 4
Service
Regulator service must be per-a.
formed only by qualied repair
personnel. Replacement parts are not available for this product. Discard product if it cannot be repaired by technician.
Inspect before every use; do not b. use if parts are loose or damaged.
SAVE THESE
INSTRUCTIONS.
Symbol Denitions
Symbol Property or statement
PSI
CFM
SCFM
NPT
NPS
Pounds per square inch of pressure
Cubic Feet per Minute ow
Cubic Feet per Minute ow at
standard conditions
National pipe thread, tapered
National pipe thread, straight
WARNING marking concerning Risk
of Eye Injury. Wear ANSI-approved
eye protection.
WARNING marking concerning Risk of Hearing Loss. Wear hearing protection.
WARNING marking concerning Risk
of Respiratory Injury. Wear NIOSH-
approved dust mask/respirator.
WARNING marking concerning Risk of Explosion.
SKU 99901 For technical questions, please call 1-800-444-3353. Page 4
Page 5
SPECIFICATIONS
Maximum Input Pressure
CO2 Inlet 1/2” -14 TPI
CO2 Bottle Size
Hose Fittings Female Quick Connectors
150 PSI
Standard 20 Oz. size with 1/2” x 14 TPI Thread
UNPACKING
When unpacking, check to make sure that the item is intact and undamaged. If any parts are missing or broken, please call Harbor Freight Tools at the number shown throughout the manual as soon as possible.
This product may be shipped with a protective plug covering the air inlet/ outlet. Remove this plug before set up.
TO PREVENT
EXPLOSION: Use only clean, dry, bottled, compressed CO2 with this regulator. Do not use oxygen or any other gas.
TO PREVENT
SERIOUS INJURY: Do not adjust any control or component in a way not
specically explained within
this manual. Improper adjustment can result in regulator failure or other serious hazards.
Female Hose Quick Connector
Belt Hook
OPERATION
Read the ENTIRE IMPORTANT
SAFETY INFORMATION section at the beginning of this manual including all text under subheadings therein before set up or use of this product.
TO PREVENT
SERIOUS INJURY AND DEATH: The work, setup, and storage areas must all be well ventilated. CO2 is an invisible odorless gas which can cause serious injury or death if it accumulates.
Regulator Control Knob
Output Gas Pressure Dial
1. Close the Regulator Control Knob completely by turning it counterclock­wise.
REV 09c
SKU 99901 For technical questions, please call 1-800-444-3353. Page 5
Page 6
CO2 Canister Connector
Belt Hook
Regulator Knob
Female Output Connector
Bottom View of Item
2. Insert a standard 20 oz. CO2 bottle (not included) into the opening at the bottom of the regulator. Turn the canister clockwise to screw it into the
Connector. Tighten rmly to prevent
leaks.
Adjust the Regulator Control Knob so 3. that the air output is enough to prop­erly power the tool, but the output will not exceed the tool’s maximum
air pressure at any time. Adjust the
pressure gradually, while checking the air output gauge to set the right pressure range.
Inspect the air connections for leaks. 4. Tighten connections to eliminate leaks.
Connect Hose to tool (not included) 5. by pressing coupler onto inlet.
Connect the Hose to the CO7.
Regu-
2
lator by pressing it onto the outlet.
The pressure supplied to the tool can 8.
be adjusted by turning the Regulator
Control Knob. Turn counterclockwise to reduce pressure. Turn clockwise to increase pressure. The pressure setting is shown on the Output Gas Pressure Dial.
Adjust the Regulator knob to the 9. pressure recommended by the tool manufacturer. Do not exceed the
tool’s maximum air pressure rat­ing.
Note: Residual air pressure should not be
present after the tool is disconnected from the CO2 supply. However, it is a good safety measure to attempt to discharge the tool in a safe fashion after disconnecting to ensure that the tool is disconnected and unpowered.
As the contents of your CO10.
canister
2
are used up, the available pressure will decrease. Available pressure will eventually fall below your regulator setting. The dial will show a lower pressure reading than desired. When pressure is no longer adequate, replace the CO2 Canister. Dispose of used canisters according to solid waste disposal instructions.
To prevent accidents, turn off the tool, 11. detach the CO2 Regulator from tool and canister, and safely discharge any residual air pressure in the tool after use.
The CO6.
Regulator has a built in
2
hook that can be used to hang it from a belt.
REV 09c
SKU 99901 For technical questions, please call 1-800-444-3353. Page 6
Page 7
USER-MAINTENANCE
INSTRUCTIONS
Procedures not specically
explained in this manual must be performed only by a
qualied technician.
Detach tool and CO2 canister, then 1. clean external surfaces of the regula­tor with clean, dry cloth.
Store the regulator indoors out of 2. children’s reach.
Note: Since this regulator is not user-
serviceable, no assembly diagram or parts list are available for this tool.
Troubleshooting
Problem Possible Causes Likely Solutions
Decreased output. Not enough air pressure and/1.
Severe air leakage. (Slight air leakage is normal, especially on older tools.)
or air ow.
Air leaking from loose hose 2. connection.
Mechanism contaminated.3.
CO4.
pressure is low or
2
depleted.
Cross-threaded components. 1.
Incorrectly installed CO2. canister.
Damaged valve or hose. 3.
2
Check for loose connections and make sure 1. that regulator is set at required pressure.
Do not exceed maximum air pressure.
Make sure hose is properly connected and 2. tight.
Have qualied technician clean mechanism. 3.
Replace CO4.
Check for incorrect alignment and uneven 1. gaps. If cross-threaded, disassemble and replace damaged parts before use.
Reinstall if cross threaded. Tighten if 2. loose. Make sure o-ring is in place at top of regulator threaded connection.
Replace or repair damaged hose. Have 3.
qualied technician repair valve.
canister.
2
Follow all safety precautions whenever diagnosing or servicing the
tool. Disconnect air supply before service.
SKU 99901 For technical questions, please call 1-800-444-3353. Page 7
Page 8
LIMITED 1 YEAR WARRANTY
Harbor Freight Tools Co. makes every effort to assure that its products meet high
quality and durability standards, and warrants to the original purchaser that this product is free from defects in materials and workmanship for the period of one year from the date of purchase. This warranty does not apply to damage due directly or indirectly, to misuse, abuse, negligence or accidents, repairs or alterations outside our facilities, nor­mal wear and tear, or to lack of maintenance. We shall in no event be liable for death,
injuries to persons or property, or for incidental, contingent, special or consequential
damages arising from the use of our product. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation of exclu­sion may not apply to you. THIS WARRANTY IS EXPRESSLY IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING THE WARRANTIES OF MER­CHANTABILITY AND FITNESS.
To take advantage of this warranty, the product or part must be returned to us with
transportation charges prepaid. Proof of purchase date and an explanation of the com­plaint must accompany the merchandise. If our inspection veries the defect, we will ei­ther repair or replace the product at our election or we may elect to refund the purchase price if we cannot readily and quickly provide you with a replacement. We will return re­paired products at our expense, but if we determine there is no defect, or that the defect resulted from causes not within the scope of our warranty, then you must bear the cost of returning the product.
This warranty gives you specic legal rights and you may also have other rights
which vary from state to state.
3491 Mission Oaks Blvd. • PO Box 6009 • Camarillo, CA 93011 • (800) 444-3353
Record Product’s Serial Number Here:
Note: If product has no serial number, record month and year of purchase instead.
SKU 99901 For technical questions, please call 1-800-444-3353. Page 8
Loading...