CEN-TECH 69096 operating instructions manual

7 FUNCTION DIGITAL MULTIMETER
OPERATING INSTRUCTIONS
Visit our Web site at http://www.harborfreight.com
Copyright© 2011 by Harbor Freight Tools®. All rights reserved.
reproduced in any shape or form without the express written consent of
Harbor Freight Tools.
For technical questions and replacement parts, please call 1-800-444-3353
69096
REV 12a
SKU 69096 For replacement parts, please call 1-800-444-3353. Page 2
Specications
Frequency 45-450 Hz
DC Amps Ranges: 200µA/2000µA/20mA/200mA, 10A
Accuracy (@200µA-200mA) 1.2%±2D; (@10A) 3%±2D
DC Voltage Ranges: 200mV/2000mV/20/200/1000V
Accuracy (@200mV) 0.5%±1D;
(@2000mV-200V) 1.0%±1D; (@1000V) 1.0%±2D
AC Voltage Ranges: 200/750V
Accuracy (45-450 Hz) 1.2%±10D
Resistance Ranges: 200/2000/20K/200K/2000K Ohm
Accuracy (@200-200K Ohm) 0.8%±2D;
(@2000K Ohm) 1.0%±2D;
Sampling Rate 2.5 times/Second
Overload Protection Fast-Acting 500mA/250V Fuse
Operating Temperature Range: 32° - 104° F
Display
1
/2″ high 3-1/2-digit LCD
Battery One 9 V (included)
Weight .45 lb.
Features
29-1/2″ Test Leads, Transistor (NPN and PNP) Testing Function,
Battery Testing Function, and Automatic Polarity and Zero Adjust
Save This Manual
You will need the manual for the safety warnings and precautions, and operating and maintenance procedures. Keep your invoice with this manual. Write the invoice number on the inside of the front cover. Keep the manual and invoice in a safe and dry place for future reference.
Safety Warnings and Precautions
WARNING: When using tool, basic safety precautions should always
be followed to reduce the risk of personal injury and damage to equipment.
Warnings continued on page 3.
SKU 69096 For replacement parts, please call 1-800-444-3353. Page 3
Read all instructions before using this tester!
1. Avoid working alone. If an accident happens, an assistant can bring help.
2. Keep work area clean. Cluttered areas invite injuries.
3. Avoid electrical shock. Use extreme caution when using this tool near uninsulated conductors or bus bars. Prevent body contact with grounded surfaces such as pipes, radiators, ranges, and cabinet enclosures when testing voltages.
4. Avoid damaging meter. Use only as specied in this manual.
5. Observe work area conditions. Do not test voltages in damp or wet locations. Don’t expose to rain. Keep work area well lit.
6. Keep children away. Children must never be allowed in the work area. Do not let them handle machines, tools, or extension cords.
7. Store idle equipment. When not in use, tools must be stored in a dry location to inhibit rust. Always lock up tools and keep out of reach of children.
8. Dress properly. Do not wear loose clothing or jewelry as they can be caught in moving parts. Protective, electrically nonconductive clothes and nonskid footwear are recommended when working. Wear restrictive hair covering to contain long hair.
9. Use eye protection. Always wear ANSI approved impact safety goggles.
10. Do not overreach. Keep proper footing and balance at all times. Do not reach over or across electrical cables or frames.
11. Maintain tools with care. Ensure multimeter has a fresh battery. Inspect test leads periodically and, if damaged, have them repaired by an authorized technician.
12. Stay alert. Watch what you are doing, use common sense. Do not operate any tool when you are tired.
13. Check for damaged parts. Before using any tool, any part that appears damaged should be carefully checked to determine that it will operate properly and perform its intended function. Check for any broken parts and any other condition that may affect proper operation. Any part that is damaged should be properly repaired or replaced
by a qualied technician. Do not use the tool if any switch does not