N7485 Drive End Housing on
CEN P/N N1506-1
Field Replacement Instructions
When replacing the drive end housing on the N1506-1 alternator, follow Figure 1 to remove the
proper through-stud on drive end of shell/stator/fi eld coil assembly.
The new N7485 drive end housing has molded B+ studs and will require the through-stud shown in Figure 1
to be removed to fit the new housing.
Use caution when removing through-stud to prevent damaging stator windings.
CAUTION
Remove this through-stud ONLY
Position center
drain hole facing you
T
T
T
T
Figure 1 — Through-stud Removal
Go to Page 2 and Figure 2 to set new drive end housing in position.
Page 1 of 2
II0107A
Position new drive end housing over remaining 8 through-studs as shown in Figure 2.
Torque values for connections:
Phase lead nuts—30 lb. in. 28 V B+ terminal nut—80 lb. in.
Field coil lead nuts—30 lb. in. 14 V B+ terminal nut—80 lb. in.
Through-stud nuts—45 lb. in. B– terminal bolt—80 lb. in.
Figure 2 — Setting New Drive End Housing in Position
C. E. Niehoff & Co. • 2021 Lee Street • Evanston, IL 60202 Tech Services Hotline 800-643-4633