C.E. Niehoff & Co. N1385-2 Installation

N1385-2 Alternator
w/ Remote-Mounted Regulator
Installation Instructions
This symbol is used to indicate
presence of hazards that can cause minor property damage.
Install alternator as shown in Figure 1:
Slip bushing located in rear mounting
foot must be securely tightened against alternator mounting bracket on engine. Failure to do so can result in broken mounting feet or broken upper mounting
bracket.
1. Units are shipped with coupling and spacer torqued in position to 163 Nm/120 lb. ft.
2. Use hardened washers between aluminum surfaces and bolt heads and nuts. Torque mounting bolts as shown in Figure 1.
Spacer
3. All cabling, wiring or conduit must be supported within 300 mm/12 in. of termination on alternator.
4. Choose wire gauge for B+ and B– cables capable of handling maximum alternator output with minimum voltage drop.
5. Install regulator in location as specified by customer.
Alternator B+ terminal
T
Washer
T
T
T
Lock washer
1/2-13 UNC 2A Bolt –
torque to 32 Nm/23.5 lb. ft.
T
Customer B+ output
cable terminal
B+ terminal (see inset above)
Regulator harness connection
Coupling
12mm/0.50 in. mounting bolt,
torque to
95 Nm/70 lb. ft.
(2 places)
T
T
T
10 mm/3/8” Mounting bolt,
grade 5 or higher,
torque to 38 Nm/29 lb. ft.
(2 places)
Vehicle harness
connection
B– terminal (either side)
T
Slip bushing must be tightened against bracket — see “CAUTION” above
10 mm x 1.5 Bolt –
torque to 9 Nm/82 lb. in.
Figure 1 — N1385-2 Alternator Installation Details
T
T
T
T
T
C. E. Niehoff & Co. • 2021 Lee Street • Evanston, IL 60202 Tech Services Hotline 800-643-4633
Page 1 of 1