C.E. Niehoff & Co. N1211, N1211-2, N1211-4, N1211-5 Installation

.
N1211, N1211-2, N1211-4, N1211-5 Alternators
C. E. Niehoff & Co
BRUSHLESS ALTERNATORS
Make alternator connections as shown on this page.
with N3106 Regulator (N1211-2)
or N3116 Regulator (N1211-4)
or N3121 Regulator (N1211-5)
Installation Instructions
Positive Terminal on alternator
Washer
Figure 1a - Positive Terminal Connections
Fuselink
Terminal on
Vehicle “B+” lead
Insulator
Washer
Lockwasher
Nut, .3750-16;
1.69 Nm / 15 lb.in.
torque to
Figure 1- Alternator (shown with regulator)
Terminal on
vehicle ground lead
Figure 1b - Ground T erminal Connections
Ground Terminal
on alternator
Washer
Lockwasher
Nut, .3125-18 UNC-2A;
torque to 1.13 Nm / 10 lb.in.
II0046APage 1 of 2
Make regulator connections as shown on this page. See page 1 for alternator connections.
#10-32 UNF-2A Screws -
Torque to 3.4 Nm/30 lb. in.
“ENERGIZE” T erminal
“AC” Terminal
Alternator-to-Regulator
Harness Receptacle
Figure 2 - N31 16 Regulator Wiring Connections
(also for N121 1-4)
0.2500-28 UNF-2A Screw ­Torque to 8.5 Nm/75 lb. in.
Figure 3 - N3121 Regulator Wiring Connections
“ENERGIZE” T erminal
“AC” Terminal
Alternator-to-Regulator
Harness Receptacle
(also for N121 1-5)
0.2500-28 UNF-2A Screw ­Torque to 8.5 Nm/75 lb. in.
If this ignition lead (568) is provided, remove it and install supplied connector cap to lead connector (568A) as shown to prevent exposure to environment
Connector cap
Vehicle harness
C. E. Niehoff & Co. • 2021 Lee Street • Evanston, IL 60202 Tech Services Hotline 800-643-4633
Regulator - “AC” T erminal
Figure 4 - N3106 Regulator Wiring Connections (also for N121 1-2)
Regulator connector
568A
5A
2A
568
Boots
Washer
#10-32 UNF-2A Screws -
Torque to 3.4 Nm/30 lb. in.
Regulator - “ENERGIZE” Terminal
Washer
Locknut, #10-24;
torque to 2.3 Nm / 20 lb.in.
Nut, 0.2500 - 20;
torque to 2.8 Nm / 25 lb.in.
II0046APage 2 of 2