C.E. Niehoff & Co. C321 Installation

Page 1
C. E. Niehoff & Co.
BRUSHLESS ALTERNATORS
C321 Alternator
Installation Instructions
This symbol is used to indicate presence of hazards that can cause
minor property damage.
Install C321 alternator as shown in Figure 1:
Slip bushing located in rear mounting
foot must be securely tightened against alternator mounting bracket on engine. Failure to do so can result in broken mounting feet or broken upper mounting bracket.
0.625 - 18 Locknut
torque to 136 Nm/100 lb.ft.
Hardened washer
12mm/0.50 in. Mounting bolt
Hardened washers
torque to 9 Nm/80 lb. in.
G
G
G
12mm/0.50 Locknut –
torque to 88 Nm/65 lb. ft.
G
1. Units are shipped with shaft collar, hardened washer and locknut. Remove and discard shaft collar. Install pulley and furnished hardened washer . Torque locknut to 136 Nm/ 100 lb. ft.
2. Use hardened washers between aluminum surfaces and bolt heads and nuts. Torque mounting bolts to 88 Nm/65 lb. ft.
3. All cabling, wiring or conduit must be sup­ported within 305 mm/12 in. of termination on alternator.
4. Choose wire gauge for B+ and B– cables capable of handling maximum alternator output with minimum voltage drop.
B– terminal
0.25-20 locknut –
G
B+ terminal
0.3125-18 locknut – torque to
G
9 Nm/80 lb. in.
G
G
12mm/0.50 in.
mounting bolt
(full length)
G
G
Hardened
washer
Alternator
mounting
bracket
on engine
G
Bracket
on engine
G
G
G
Slip bushing must be tightened against bracket — see “CAUTION” above
12mm/0.50 Locknut –
torque to
88 Nm/65 lb. ft.
Hardened washer
Figure 1 - C321 Alternator Installation Details
C. E. Niehoff & Co. • 2021 Lee Street • Evanston, IL 60202 Tech Services Hotline 800-643-4633
II0006APage 1 of 1